RPD , RPT , RPTG : Medical Open Frame Power Supply ; MPQ : Medical Grade Output Power Supply

102 products

MEAN WELL Medical Multi-Output Power Supply (RPD/RPT/MPQ Series)

  • Product Features
  • General Specifications
  • Output Models Overview
  • Product Ordering Code

Product Features

  • Medical Safety Certified: 2 x MOPP (Primary to Secondary) compliant with IEC/EN60601-1 and ANSI/AAMI ES60601-1.
  • Multi-Channel Output: Supports Dual (RPD), Triple (RPT), and Quad (MPQ) output configurations for complex system requirements.
  • High Efficiency & PFC: Features active PFC function (for higher wattage models) and high-efficiency circuit design.
  • Low Leakage: Ultra-low leakage current (<100µA to <160µA), ideal for BF (Body Floating) medical equipment.
  • Flexible Cooling: Supports dual power ratings (natural convection vs. forced air cooling with CFM ratings).
  • Advanced Control: Select models (RPT-160G) include 5V auxiliary standby and PS-ON control signal.
  • Diverse Mounting: Compact bare PCB designs with optional enclosed (-C) covers.
  • Comprehensive Protection: Built-in short circuit, overload, over voltage, and over temperature (on select models) protections.

General Specifications

Item Specification Description
Input Voltage 90 ~ 264VAC / 127 ~ 370VDC (Universal Input)
Frequency 47 ~ 63Hz
Isolation I/P-O/P: 2xMOPP; I/P-FG: 1xMOPP; O/P-FG: 1xMOPP
Withstand Voltage I/P-O/P: 4KVAC; I/P-FG: 2KVAC; O/P-FG: 1.5KVAC
Working Temp. -20°C ~ +70°C (Refer to specific model derating curve)
Safety Standards IEC 60601-1, TUV/EN 60601-1, ANSI/AAMI ES60601-1, EAC, UL62368-1
EMC Emission BS EN/EN55011 (CISPR11) Class B

Output Models Overview

RPD & RPT Series (50W - 160W)

Series Configuration Max Power
RPD-60/65/75 Dual Output (e.g., 5V/12V, 24V) 50W - 75W
RPT-60/65/75 Triple Output (e.g., 5V/12V/-5V) 40W - 75W
RPT-160 Triple Output (w/ PFC/Standby) 98W (Conv.) / 145W (CFM)

MPQ-200 Series (200W Quad Output)

Model CH1 CH2 CH3 CH4
MPQ-200B 5V/15A 12V/7A -5V/2A -12V/2A
MPQ-200D 5V/15A 24V/3A 12V/2A -12V/2A
Note: MPQ-200 series requires 25CFM forced air cooling to achieve rated output currents.

Product Ordering Code

No. Item Description
1 Series RPD (Dual), RPT (Triple), MPQ (Quad)
2 Control Option Blank (Standard); G (w/ 5Vsb & PS-ON for RPT-160)
3 Rated Power 60W, 65W, 75W, 160W, 200W
4 Config Voltage combination identifier (A, B, C, D, F, etc.)
5 Enclosure Blank (Bare PCB); -C (Enclosed w/ cover)
Example: RPTG-160B-C (160W Triple Output, 5Vsb/PS-ON, Enclosed).
  • MPQ-200F

    MEAN WELL MPQ-200 series: Quad-Output Medical AC/DC Power Supply - MPQ-200F

    MEAN WELL MPQ-200F is a PCB-type four-output medical AC/DC power supply. It provides CH1 5 V, CH2 24 V, CH3 15 V, CH4 −15 V. The total continuous output is limited to 140 W with natural convection or 200 W with at least 25 CFM forced airflow, together with every channel limit and applicable derating. Product Datasheet Download MEAN WELL MPQ-200 Datasheet (PDF) The MPQ-200 section is on PDF pages 26, 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Configuration Complete model MPQ-200F Output arrangement 4 outputs sharing the stated COM reference; polarity is shown separately for every channel. Construction PCB assembly for installation inside equipment. Nominal efficiency, typical 81%. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. Combined Load and Peak Limits Total continuous output 140 W maximum with natural convection; 200 W maximum with 25 CFM forced air. Individual channel limits also apply. Peak-current operation The peak-current column requires a 25 CFM fan. Maximum duty cycle is 33% within every 30 seconds, with average output power not exceeding rated power. Channel 1 voltage adjustment −5% to +10% of nominal CH1 voltage via the potentiometer; for 5 V CH1 this calculates to 4.75–5.5 V. The channel maximums are not permission to load every output to its maximum simultaneously. Keep the sum of the absolute channel output powers within the applicable combined power limit and meet all minimum-load requirements. Negative output voltage denotes polarity, not negative delivered power. The peak-current table does not print a separate combined peak-wattage limit or an independent pulse-duration value. The per-channel peak limits must not be added together as an allowable combined peak load. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. CH1 Electrical Ratings Output voltage 5 V. Rated current 15 A. Minimum load 3 A. Convection maximum current 12 A. Current with 25 CFM fan 15 A. Peak current with 25 CFM fan 18 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH2 Electrical Ratings Output voltage 24 V. Rated current 2.7 A. Minimum load 0.3 A. Convection maximum current 2.1 A. Current with 25 CFM fan 2.7 A. Peak current with 25 CFM fan 3.3 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 180 mVp-p. Voltage tolerance ±8.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH3 Electrical Ratings Output voltage 15 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH4 Electrical Ratings Output voltage −15 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. Input and Start-Up Input range 90–264 VAC, 47–63 Hz, or 127–370 VDC. Apply low-input derating. Input current, typical 3.5 A at 115 VAC; 1.6 A at 230 VAC, at 60 Hz and full output load. Cold-start inrush, typical Less than 25 A at 115 VAC; less than 40 A at 230 VAC, limited by internal thermistors. Set-up / rise time 1000 / 20 ms at 230 VAC; 3000 / 20 ms at 115 VAC, full load. Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load. Switching-frequency reference 100 kHz. Power factor, typical >0.95 at 230 VAC and >0.98 at 115 VAC, full load. Protection Short circuit / overload Hiccup protection at 120–160% rated load, with automatic recovery after the fault is removed. Overvoltage protection CH1 only, at 115–135% of its rated voltage. The output shuts down when activated; the page does not specify a recovery method. Overtemperature protection TSW1 senses the power-transistor heat sink. At 95°C the output shuts down; it recovers automatically after temperature falls. This is a heat-sink sensor threshold, not an ambient-temperature rating. Protection thresholds are fault limits, not additional operating ratings. Control, Status and Remote Sense Power Good / Power Fail TTL high indicates power good; low indicates failure. At 90% of rated output voltage, the +5 V TTL signal is asserted after 10–500 ms. It goes low at least 1 ms before output falls below 90% of rated voltage. Remote ON/OFF Across RC+ and RC−: 0–0.8 V turns the output on; 4–10 V turns it off. The catalogue prints the sink-current reference as <4–10 mA; confirm interface drive requirements from the manufacturer application instructions. Remote sense CN4 pin 5 RS+ and pin 2 RS−. Observe the correct output polarity and the manufacturer wiring instructions; these pages do not state a maximum compensation voltage. Power indication The mechanical drawing marks the LED power indicator. The status signal is available at CN4 pin 1 PG with pin 3 GND. Remote control is on pin 4 RC+ and pin 6 RC−; these functions must not be inferred from the connector position alone. No standby output is specified for these four-output models. Derating and Environment Working temperature −20 to +70°C, subject to the cooling curve. Thermal curve Horizontal mounting: natural convection allows 70% of the 200 W family rating through 40°C, falling to 30% at 60°C. With 25 CFM forced air, 100% is available through 50°C, falling to 40% at 70°C. The no-fan curve ends at 60°C. Input-voltage curve, 60 Hz 80% load at 90 VAC; 100% at 115 VAC through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage conditions −40 to +85°C; 10–90% RH. Temperature coefficient ±0.04%/°C on all outputs at full load, over 0–50°C. Vibration 10–500 Hz, 2 G; 10-minute cycles, six cycles / 60 minutes along each X, Y and Z axis. Altitude condition Above 2000 m, reduce allowable ambient temperature by 3.5°C per additional 1000 m for fanless operation, or 5°C per additional 1000 m for fan-cooled operation. No absolute operating-altitude maximum is specified on these MPQ pages. Apply temperature, input-voltage, cooling and channel loading restrictions together. Do not extrapolate beyond the plotted curve or treat a series name as the guaranteed output wattage. Installation and Mechanical Details Dimensions, L × W × H 177.8 × 107.2 × 35.5 mm. Drawing dimensions Millimetres, general tolerance ±1 mm; 4 x Ø3.96 mm on 165.1 × 95.25 mm centres. Underside clearance 3 mm maximum component projection is shown below the board; allow the installation clearance required by the manufacturer. It is not a mounting-screw penetration rating. Mounting references Edge references 6.35 mm and 6.1 mm; the FG position is marked near the AC input. Forced-air installation At least 25 CFM, fan 15 cm from the illustrated board edge, with the shown airflow direction. Use the applicable complete mechanical drawing and installation instructions. The listed mating connector references, external fan and mounting hardware are not stated to be supplied accessories. Maintain the marked protective-ground connection and verify safety and EMC in the final equipment. Connectors and Mating References AC input CN1 JST B3P-VH or equivalent: pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing reference JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Main output CN2 and CN3 Two JST B8P-VH connectors or equivalents, using combined numbering 1–16: pins 1–4 V1; 5–11 COM; 12–13 V2; 14 V3; 15 absent; 16 V4. Use the signed channel voltages listed above. Signal connector CN4 JS-2008-03*2 or equivalent: 1 PG, 2 RS−, 3 GND, 4 RC+, 5 RS+, 6 RC−. Mating housing JS-2007-03*2; terminal JS-2007-T or equivalent. The main input/output connectors use the JST VHR housing family and JST SVH-21T-P1.1 contact reference. Select the complete mating housing for the required circuit count and wire size; loose mating parts and any external fan are not stated as included. Medical Isolation, Leakage and Safety Isolation level Primary–secondary: 2 MOPP. No additional MOPP levels are assigned here. Withstand voltage Input–output 4 kVAC; input–FG 2 kVAC; output–FG 1.5 kVAC. Insulation resistance Greater than 100 MΩ at 500 VDC, for input–output, input–FG and output–FG. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC. Touch current is measured from primary input to DC output. The safety table lists IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; and EAC TP TC004. The cover also carries UL60950-1. Verify the applicable component approval in the final equipment configuration. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. EMC and System Integration Conducted and radiated emissions: BS EN/EN55011 Class B. Harmonic current: BS EN/EN61000-3-2; voltage flicker: BS EN/EN61000-3-3; EAC TP TC020 is listed. The immunity table references EN61000-4-2 ESD: 8 kV air (Level 3) and 4 kV contact (Level 2); EN61000-4-3 RF field: 3 and 10 V/m; EN61000-4-4 EFT: 1 and 2 kV at 5 kHz; EN61000-4-5 surge: 2 kV line–line and 4 kV line–earth; EN61000-4-8 magnetic field: 3 and 10 A/m. EN61000-4-11 voltage dips/interruptions, EN61000-4-6 conducted RF and ENV50204 at 900 MHz are also referenced. Use the applicable manufacturer test report for precise conducted-RF and digital-phone test-level details. EMC tests used the unit on a 360 × 360 mm metal plate, 1 mm thick. This component is intended for installation in final equipment; reconfirm EMC compliance in the completed system. Weight and Reliability Catalogue single-unit reference 0.66 kg = 660 g per unit, from the PACKING entry. Carton reference 24 pieces / 16.8 kg / 1.17 CUFT; carton weight is not the per-unit product weight. MTBF, minimum 1679.6 K hours, Telcordia SR-332 (Bellcore); 213.8 K hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue edition MPQ-200-SPEC 2024-10-30; combined PDF pages 26–28. PACKING is a catalogue single-unit reference, not an independently weighed net or shipping mass. MTBF is a statistical estimate under the stated methods.

    $209.46

  • MPQ-200F

    MEAN WELL MPQ-200 series: Quad-Output Medical AC/DC Power Supply - MPQ-200F

    MEAN WELL MPQ-200F is a PCB-type four-output medical AC/DC power supply. It provides CH1 5 V, CH2 24 V, CH3 15 V, CH4 −15 V. The total continuous output is limited to 140 W with natural convection or 200 W with at least 25 CFM forced airflow, together with every channel limit and applicable derating. Product Datasheet Download MEAN WELL MPQ-200 Datasheet (PDF) The MPQ-200 section is on PDF pages 26, 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Configuration Complete model MPQ-200F Output arrangement 4 outputs sharing the stated COM reference; polarity is shown separately for every channel. Construction PCB assembly for installation inside equipment. Nominal efficiency, typical 81%. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. Combined Load and Peak Limits Total continuous output 140 W maximum with natural convection; 200 W maximum with 25 CFM forced air. Individual channel limits also apply. Peak-current operation The peak-current column requires a 25 CFM fan. Maximum duty cycle is 33% within every 30 seconds, with average output power not exceeding rated power. Channel 1 voltage adjustment −5% to +10% of nominal CH1 voltage via the potentiometer; for 5 V CH1 this calculates to 4.75–5.5 V. The channel maximums are not permission to load every output to its maximum simultaneously. Keep the sum of the absolute channel output powers within the applicable combined power limit and meet all minimum-load requirements. Negative output voltage denotes polarity, not negative delivered power. The peak-current table does not print a separate combined peak-wattage limit or an independent pulse-duration value. The per-channel peak limits must not be added together as an allowable combined peak load. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. CH1 Electrical Ratings Output voltage 5 V. Rated current 15 A. Minimum load 3 A. Convection maximum current 12 A. Current with 25 CFM fan 15 A. Peak current with 25 CFM fan 18 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH2 Electrical Ratings Output voltage 24 V. Rated current 2.7 A. Minimum load 0.3 A. Convection maximum current 2.1 A. Current with 25 CFM fan 2.7 A. Peak current with 25 CFM fan 3.3 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 180 mVp-p. Voltage tolerance ±8.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH3 Electrical Ratings Output voltage 15 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH4 Electrical Ratings Output voltage −15 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. Input and Start-Up Input range 90–264 VAC, 47–63 Hz, or 127–370 VDC. Apply low-input derating. Input current, typical 3.5 A at 115 VAC; 1.6 A at 230 VAC, at 60 Hz and full output load. Cold-start inrush, typical Less than 25 A at 115 VAC; less than 40 A at 230 VAC, limited by internal thermistors. Set-up / rise time 1000 / 20 ms at 230 VAC; 3000 / 20 ms at 115 VAC, full load. Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load. Switching-frequency reference 100 kHz. Power factor, typical >0.95 at 230 VAC and >0.98 at 115 VAC, full load. Protection Short circuit / overload Hiccup protection at 120–160% rated load, with automatic recovery after the fault is removed. Overvoltage protection CH1 only, at 115–135% of its rated voltage. The output shuts down when activated; the page does not specify a recovery method. Overtemperature protection TSW1 senses the power-transistor heat sink. At 95°C the output shuts down; it recovers automatically after temperature falls. This is a heat-sink sensor threshold, not an ambient-temperature rating. Protection thresholds are fault limits, not additional operating ratings. Control, Status and Remote Sense Power Good / Power Fail TTL high indicates power good; low indicates failure. At 90% of rated output voltage, the +5 V TTL signal is asserted after 10–500 ms. It goes low at least 1 ms before output falls below 90% of rated voltage. Remote ON/OFF Across RC+ and RC−: 0–0.8 V turns the output on; 4–10 V turns it off. The catalogue prints the sink-current reference as <4–10 mA; confirm interface drive requirements from the manufacturer application instructions. Remote sense CN4 pin 5 RS+ and pin 2 RS−. Observe the correct output polarity and the manufacturer wiring instructions; these pages do not state a maximum compensation voltage. Power indication The mechanical drawing marks the LED power indicator. The status signal is available at CN4 pin 1 PG with pin 3 GND. Remote control is on pin 4 RC+ and pin 6 RC−; these functions must not be inferred from the connector position alone. No standby output is specified for these four-output models. Derating and Environment Working temperature −20 to +70°C, subject to the cooling curve. Thermal curve Horizontal mounting: natural convection allows 70% of the 200 W family rating through 40°C, falling to 30% at 60°C. With 25 CFM forced air, 100% is available through 50°C, falling to 40% at 70°C. The no-fan curve ends at 60°C. Input-voltage curve, 60 Hz 80% load at 90 VAC; 100% at 115 VAC through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage conditions −40 to +85°C; 10–90% RH. Temperature coefficient ±0.04%/°C on all outputs at full load, over 0–50°C. Vibration 10–500 Hz, 2 G; 10-minute cycles, six cycles / 60 minutes along each X, Y and Z axis. Altitude condition Above 2000 m, reduce allowable ambient temperature by 3.5°C per additional 1000 m for fanless operation, or 5°C per additional 1000 m for fan-cooled operation. No absolute operating-altitude maximum is specified on these MPQ pages. Apply temperature, input-voltage, cooling and channel loading restrictions together. Do not extrapolate beyond the plotted curve or treat a series name as the guaranteed output wattage. Installation and Mechanical Details Dimensions, L × W × H 177.8 × 107.2 × 35.5 mm. Drawing dimensions Millimetres, general tolerance ±1 mm; 4 x Ø3.96 mm on 165.1 × 95.25 mm centres. Underside clearance 3 mm maximum component projection is shown below the board; allow the installation clearance required by the manufacturer. It is not a mounting-screw penetration rating. Mounting references Edge references 6.35 mm and 6.1 mm; the FG position is marked near the AC input. Forced-air installation At least 25 CFM, fan 15 cm from the illustrated board edge, with the shown airflow direction. Use the applicable complete mechanical drawing and installation instructions. The listed mating connector references, external fan and mounting hardware are not stated to be supplied accessories. Maintain the marked protective-ground connection and verify safety and EMC in the final equipment. Connectors and Mating References AC input CN1 JST B3P-VH or equivalent: pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing reference JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Main output CN2 and CN3 Two JST B8P-VH connectors or equivalents, using combined numbering 1–16: pins 1–4 V1; 5–11 COM; 12–13 V2; 14 V3; 15 absent; 16 V4. Use the signed channel voltages listed above. Signal connector CN4 JS-2008-03*2 or equivalent: 1 PG, 2 RS−, 3 GND, 4 RC+, 5 RS+, 6 RC−. Mating housing JS-2007-03*2; terminal JS-2007-T or equivalent. The main input/output connectors use the JST VHR housing family and JST SVH-21T-P1.1 contact reference. Select the complete mating housing for the required circuit count and wire size; loose mating parts and any external fan are not stated as included. Medical Isolation, Leakage and Safety Isolation level Primary–secondary: 2 MOPP. No additional MOPP levels are assigned here. Withstand voltage Input–output 4 kVAC; input–FG 2 kVAC; output–FG 1.5 kVAC. Insulation resistance Greater than 100 MΩ at 500 VDC, for input–output, input–FG and output–FG. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC. Touch current is measured from primary input to DC output. The safety table lists IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; and EAC TP TC004. The cover also carries UL60950-1. Verify the applicable component approval in the final equipment configuration. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. EMC and System Integration Conducted and radiated emissions: BS EN/EN55011 Class B. Harmonic current: BS EN/EN61000-3-2; voltage flicker: BS EN/EN61000-3-3; EAC TP TC020 is listed. The immunity table references EN61000-4-2 ESD: 8 kV air (Level 3) and 4 kV contact (Level 2); EN61000-4-3 RF field: 3 and 10 V/m; EN61000-4-4 EFT: 1 and 2 kV at 5 kHz; EN61000-4-5 surge: 2 kV line–line and 4 kV line–earth; EN61000-4-8 magnetic field: 3 and 10 A/m. EN61000-4-11 voltage dips/interruptions, EN61000-4-6 conducted RF and ENV50204 at 900 MHz are also referenced. Use the applicable manufacturer test report for precise conducted-RF and digital-phone test-level details. EMC tests used the unit on a 360 × 360 mm metal plate, 1 mm thick. This component is intended for installation in final equipment; reconfirm EMC compliance in the completed system. Weight and Reliability Catalogue single-unit reference 0.66 kg = 660 g per unit, from the PACKING entry. Carton reference 24 pieces / 16.8 kg / 1.17 CUFT; carton weight is not the per-unit product weight. MTBF, minimum 1679.6 K hours, Telcordia SR-332 (Bellcore); 213.8 K hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue edition MPQ-200-SPEC 2024-10-30; combined PDF pages 26–28. PACKING is a catalogue single-unit reference, not an independently weighed net or shipping mass. MTBF is a statistical estimate under the stated methods.

    $209.46

  • MPQ-200F

    MEAN WELL MPQ-200 series: Quad-Output Medical AC/DC Power Supply - MPQ-200F

    MEAN WELL MPQ-200F is a PCB-type four-output medical AC/DC power supply. It provides CH1 5 V, CH2 24 V, CH3 15 V, CH4 −15 V. The total continuous output is limited to 140 W with natural convection or 200 W with at least 25 CFM forced airflow, together with every channel limit and applicable derating. Product Datasheet Download MEAN WELL MPQ-200 Datasheet (PDF) The MPQ-200 section is on PDF pages 26, 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Configuration Complete model MPQ-200F Output arrangement 4 outputs sharing the stated COM reference; polarity is shown separately for every channel. Construction PCB assembly for installation inside equipment. Nominal efficiency, typical 81%. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. Combined Load and Peak Limits Total continuous output 140 W maximum with natural convection; 200 W maximum with 25 CFM forced air. Individual channel limits also apply. Peak-current operation The peak-current column requires a 25 CFM fan. Maximum duty cycle is 33% within every 30 seconds, with average output power not exceeding rated power. Channel 1 voltage adjustment −5% to +10% of nominal CH1 voltage via the potentiometer; for 5 V CH1 this calculates to 4.75–5.5 V. The channel maximums are not permission to load every output to its maximum simultaneously. Keep the sum of the absolute channel output powers within the applicable combined power limit and meet all minimum-load requirements. Negative output voltage denotes polarity, not negative delivered power. The peak-current table does not print a separate combined peak-wattage limit or an independent pulse-duration value. The per-channel peak limits must not be added together as an allowable combined peak load. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. CH1 Electrical Ratings Output voltage 5 V. Rated current 15 A. Minimum load 3 A. Convection maximum current 12 A. Current with 25 CFM fan 15 A. Peak current with 25 CFM fan 18 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH2 Electrical Ratings Output voltage 24 V. Rated current 2.7 A. Minimum load 0.3 A. Convection maximum current 2.1 A. Current with 25 CFM fan 2.7 A. Peak current with 25 CFM fan 3.3 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 180 mVp-p. Voltage tolerance ±8.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH3 Electrical Ratings Output voltage 15 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH4 Electrical Ratings Output voltage −15 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. Input and Start-Up Input range 90–264 VAC, 47–63 Hz, or 127–370 VDC. Apply low-input derating. Input current, typical 3.5 A at 115 VAC; 1.6 A at 230 VAC, at 60 Hz and full output load. Cold-start inrush, typical Less than 25 A at 115 VAC; less than 40 A at 230 VAC, limited by internal thermistors. Set-up / rise time 1000 / 20 ms at 230 VAC; 3000 / 20 ms at 115 VAC, full load. Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load. Switching-frequency reference 100 kHz. Power factor, typical >0.95 at 230 VAC and >0.98 at 115 VAC, full load. Protection Short circuit / overload Hiccup protection at 120–160% rated load, with automatic recovery after the fault is removed. Overvoltage protection CH1 only, at 115–135% of its rated voltage. The output shuts down when activated; the page does not specify a recovery method. Overtemperature protection TSW1 senses the power-transistor heat sink. At 95°C the output shuts down; it recovers automatically after temperature falls. This is a heat-sink sensor threshold, not an ambient-temperature rating. Protection thresholds are fault limits, not additional operating ratings. Control, Status and Remote Sense Power Good / Power Fail TTL high indicates power good; low indicates failure. At 90% of rated output voltage, the +5 V TTL signal is asserted after 10–500 ms. It goes low at least 1 ms before output falls below 90% of rated voltage. Remote ON/OFF Across RC+ and RC−: 0–0.8 V turns the output on; 4–10 V turns it off. The catalogue prints the sink-current reference as <4–10 mA; confirm interface drive requirements from the manufacturer application instructions. Remote sense CN4 pin 5 RS+ and pin 2 RS−. Observe the correct output polarity and the manufacturer wiring instructions; these pages do not state a maximum compensation voltage. Power indication The mechanical drawing marks the LED power indicator. The status signal is available at CN4 pin 1 PG with pin 3 GND. Remote control is on pin 4 RC+ and pin 6 RC−; these functions must not be inferred from the connector position alone. No standby output is specified for these four-output models. Derating and Environment Working temperature −20 to +70°C, subject to the cooling curve. Thermal curve Horizontal mounting: natural convection allows 70% of the 200 W family rating through 40°C, falling to 30% at 60°C. With 25 CFM forced air, 100% is available through 50°C, falling to 40% at 70°C. The no-fan curve ends at 60°C. Input-voltage curve, 60 Hz 80% load at 90 VAC; 100% at 115 VAC through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage conditions −40 to +85°C; 10–90% RH. Temperature coefficient ±0.04%/°C on all outputs at full load, over 0–50°C. Vibration 10–500 Hz, 2 G; 10-minute cycles, six cycles / 60 minutes along each X, Y and Z axis. Altitude condition Above 2000 m, reduce allowable ambient temperature by 3.5°C per additional 1000 m for fanless operation, or 5°C per additional 1000 m for fan-cooled operation. No absolute operating-altitude maximum is specified on these MPQ pages. Apply temperature, input-voltage, cooling and channel loading restrictions together. Do not extrapolate beyond the plotted curve or treat a series name as the guaranteed output wattage. Installation and Mechanical Details Dimensions, L × W × H 177.8 × 107.2 × 35.5 mm. Drawing dimensions Millimetres, general tolerance ±1 mm; 4 x Ø3.96 mm on 165.1 × 95.25 mm centres. Underside clearance 3 mm maximum component projection is shown below the board; allow the installation clearance required by the manufacturer. It is not a mounting-screw penetration rating. Mounting references Edge references 6.35 mm and 6.1 mm; the FG position is marked near the AC input. Forced-air installation At least 25 CFM, fan 15 cm from the illustrated board edge, with the shown airflow direction. Use the applicable complete mechanical drawing and installation instructions. The listed mating connector references, external fan and mounting hardware are not stated to be supplied accessories. Maintain the marked protective-ground connection and verify safety and EMC in the final equipment. Connectors and Mating References AC input CN1 JST B3P-VH or equivalent: pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing reference JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Main output CN2 and CN3 Two JST B8P-VH connectors or equivalents, using combined numbering 1–16: pins 1–4 V1; 5–11 COM; 12–13 V2; 14 V3; 15 absent; 16 V4. Use the signed channel voltages listed above. Signal connector CN4 JS-2008-03*2 or equivalent: 1 PG, 2 RS−, 3 GND, 4 RC+, 5 RS+, 6 RC−. Mating housing JS-2007-03*2; terminal JS-2007-T or equivalent. The main input/output connectors use the JST VHR housing family and JST SVH-21T-P1.1 contact reference. Select the complete mating housing for the required circuit count and wire size; loose mating parts and any external fan are not stated as included. Medical Isolation, Leakage and Safety Isolation level Primary–secondary: 2 MOPP. No additional MOPP levels are assigned here. Withstand voltage Input–output 4 kVAC; input–FG 2 kVAC; output–FG 1.5 kVAC. Insulation resistance Greater than 100 MΩ at 500 VDC, for input–output, input–FG and output–FG. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC. Touch current is measured from primary input to DC output. The safety table lists IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; and EAC TP TC004. The cover also carries UL60950-1. Verify the applicable component approval in the final equipment configuration. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. EMC and System Integration Conducted and radiated emissions: BS EN/EN55011 Class B. Harmonic current: BS EN/EN61000-3-2; voltage flicker: BS EN/EN61000-3-3; EAC TP TC020 is listed. The immunity table references EN61000-4-2 ESD: 8 kV air (Level 3) and 4 kV contact (Level 2); EN61000-4-3 RF field: 3 and 10 V/m; EN61000-4-4 EFT: 1 and 2 kV at 5 kHz; EN61000-4-5 surge: 2 kV line–line and 4 kV line–earth; EN61000-4-8 magnetic field: 3 and 10 A/m. EN61000-4-11 voltage dips/interruptions, EN61000-4-6 conducted RF and ENV50204 at 900 MHz are also referenced. Use the applicable manufacturer test report for precise conducted-RF and digital-phone test-level details. EMC tests used the unit on a 360 × 360 mm metal plate, 1 mm thick. This component is intended for installation in final equipment; reconfirm EMC compliance in the completed system. Weight and Reliability Catalogue single-unit reference 0.66 kg = 660 g per unit, from the PACKING entry. Carton reference 24 pieces / 16.8 kg / 1.17 CUFT; carton weight is not the per-unit product weight. MTBF, minimum 1679.6 K hours, Telcordia SR-332 (Bellcore); 213.8 K hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue edition MPQ-200-SPEC 2024-10-30; combined PDF pages 26–28. PACKING is a catalogue single-unit reference, not an independently weighed net or shipping mass. MTBF is a statistical estimate under the stated methods.

    $209.46

  • MPQ-200F

    MEAN WELL MPQ-200 series: Quad-Output Medical AC/DC Power Supply - MPQ-200F

    MEAN WELL MPQ-200F is a PCB-type four-output medical AC/DC power supply. It provides CH1 5 V, CH2 24 V, CH3 15 V, CH4 −15 V. The total continuous output is limited to 140 W with natural convection or 200 W with at least 25 CFM forced airflow, together with every channel limit and applicable derating. Product Datasheet Download MEAN WELL MPQ-200 Datasheet (PDF) The MPQ-200 section is on PDF pages 26, 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Configuration Complete model MPQ-200F Output arrangement 4 outputs sharing the stated COM reference; polarity is shown separately for every channel. Construction PCB assembly for installation inside equipment. Nominal efficiency, typical 81%. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. Combined Load and Peak Limits Total continuous output 140 W maximum with natural convection; 200 W maximum with 25 CFM forced air. Individual channel limits also apply. Peak-current operation The peak-current column requires a 25 CFM fan. Maximum duty cycle is 33% within every 30 seconds, with average output power not exceeding rated power. Channel 1 voltage adjustment −5% to +10% of nominal CH1 voltage via the potentiometer; for 5 V CH1 this calculates to 4.75–5.5 V. The channel maximums are not permission to load every output to its maximum simultaneously. Keep the sum of the absolute channel output powers within the applicable combined power limit and meet all minimum-load requirements. Negative output voltage denotes polarity, not negative delivered power. The peak-current table does not print a separate combined peak-wattage limit or an independent pulse-duration value. The per-channel peak limits must not be added together as an allowable combined peak load. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. CH1 Electrical Ratings Output voltage 5 V. Rated current 15 A. Minimum load 3 A. Convection maximum current 12 A. Current with 25 CFM fan 15 A. Peak current with 25 CFM fan 18 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH2 Electrical Ratings Output voltage 24 V. Rated current 2.7 A. Minimum load 0.3 A. Convection maximum current 2.1 A. Current with 25 CFM fan 2.7 A. Peak current with 25 CFM fan 3.3 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 180 mVp-p. Voltage tolerance ±8.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH3 Electrical Ratings Output voltage 15 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH4 Electrical Ratings Output voltage −15 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. Input and Start-Up Input range 90–264 VAC, 47–63 Hz, or 127–370 VDC. Apply low-input derating. Input current, typical 3.5 A at 115 VAC; 1.6 A at 230 VAC, at 60 Hz and full output load. Cold-start inrush, typical Less than 25 A at 115 VAC; less than 40 A at 230 VAC, limited by internal thermistors. Set-up / rise time 1000 / 20 ms at 230 VAC; 3000 / 20 ms at 115 VAC, full load. Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load. Switching-frequency reference 100 kHz. Power factor, typical >0.95 at 230 VAC and >0.98 at 115 VAC, full load. Protection Short circuit / overload Hiccup protection at 120–160% rated load, with automatic recovery after the fault is removed. Overvoltage protection CH1 only, at 115–135% of its rated voltage. The output shuts down when activated; the page does not specify a recovery method. Overtemperature protection TSW1 senses the power-transistor heat sink. At 95°C the output shuts down; it recovers automatically after temperature falls. This is a heat-sink sensor threshold, not an ambient-temperature rating. Protection thresholds are fault limits, not additional operating ratings. Control, Status and Remote Sense Power Good / Power Fail TTL high indicates power good; low indicates failure. At 90% of rated output voltage, the +5 V TTL signal is asserted after 10–500 ms. It goes low at least 1 ms before output falls below 90% of rated voltage. Remote ON/OFF Across RC+ and RC−: 0–0.8 V turns the output on; 4–10 V turns it off. The catalogue prints the sink-current reference as <4–10 mA; confirm interface drive requirements from the manufacturer application instructions. Remote sense CN4 pin 5 RS+ and pin 2 RS−. Observe the correct output polarity and the manufacturer wiring instructions; these pages do not state a maximum compensation voltage. Power indication The mechanical drawing marks the LED power indicator. The status signal is available at CN4 pin 1 PG with pin 3 GND. Remote control is on pin 4 RC+ and pin 6 RC−; these functions must not be inferred from the connector position alone. No standby output is specified for these four-output models. Derating and Environment Working temperature −20 to +70°C, subject to the cooling curve. Thermal curve Horizontal mounting: natural convection allows 70% of the 200 W family rating through 40°C, falling to 30% at 60°C. With 25 CFM forced air, 100% is available through 50°C, falling to 40% at 70°C. The no-fan curve ends at 60°C. Input-voltage curve, 60 Hz 80% load at 90 VAC; 100% at 115 VAC through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage conditions −40 to +85°C; 10–90% RH. Temperature coefficient ±0.04%/°C on all outputs at full load, over 0–50°C. Vibration 10–500 Hz, 2 G; 10-minute cycles, six cycles / 60 minutes along each X, Y and Z axis. Altitude condition Above 2000 m, reduce allowable ambient temperature by 3.5°C per additional 1000 m for fanless operation, or 5°C per additional 1000 m for fan-cooled operation. No absolute operating-altitude maximum is specified on these MPQ pages. Apply temperature, input-voltage, cooling and channel loading restrictions together. Do not extrapolate beyond the plotted curve or treat a series name as the guaranteed output wattage. Installation and Mechanical Details Dimensions, L × W × H 177.8 × 107.2 × 35.5 mm. Drawing dimensions Millimetres, general tolerance ±1 mm; 4 x Ø3.96 mm on 165.1 × 95.25 mm centres. Underside clearance 3 mm maximum component projection is shown below the board; allow the installation clearance required by the manufacturer. It is not a mounting-screw penetration rating. Mounting references Edge references 6.35 mm and 6.1 mm; the FG position is marked near the AC input. Forced-air installation At least 25 CFM, fan 15 cm from the illustrated board edge, with the shown airflow direction. Use the applicable complete mechanical drawing and installation instructions. The listed mating connector references, external fan and mounting hardware are not stated to be supplied accessories. Maintain the marked protective-ground connection and verify safety and EMC in the final equipment. Connectors and Mating References AC input CN1 JST B3P-VH or equivalent: pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing reference JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Main output CN2 and CN3 Two JST B8P-VH connectors or equivalents, using combined numbering 1–16: pins 1–4 V1; 5–11 COM; 12–13 V2; 14 V3; 15 absent; 16 V4. Use the signed channel voltages listed above. Signal connector CN4 JS-2008-03*2 or equivalent: 1 PG, 2 RS−, 3 GND, 4 RC+, 5 RS+, 6 RC−. Mating housing JS-2007-03*2; terminal JS-2007-T or equivalent. The main input/output connectors use the JST VHR housing family and JST SVH-21T-P1.1 contact reference. Select the complete mating housing for the required circuit count and wire size; loose mating parts and any external fan are not stated as included. Medical Isolation, Leakage and Safety Isolation level Primary–secondary: 2 MOPP. No additional MOPP levels are assigned here. Withstand voltage Input–output 4 kVAC; input–FG 2 kVAC; output–FG 1.5 kVAC. Insulation resistance Greater than 100 MΩ at 500 VDC, for input–output, input–FG and output–FG. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC. Touch current is measured from primary input to DC output. The safety table lists IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; and EAC TP TC004. The cover also carries UL60950-1. Verify the applicable component approval in the final equipment configuration. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. EMC and System Integration Conducted and radiated emissions: BS EN/EN55011 Class B. Harmonic current: BS EN/EN61000-3-2; voltage flicker: BS EN/EN61000-3-3; EAC TP TC020 is listed. The immunity table references EN61000-4-2 ESD: 8 kV air (Level 3) and 4 kV contact (Level 2); EN61000-4-3 RF field: 3 and 10 V/m; EN61000-4-4 EFT: 1 and 2 kV at 5 kHz; EN61000-4-5 surge: 2 kV line–line and 4 kV line–earth; EN61000-4-8 magnetic field: 3 and 10 A/m. EN61000-4-11 voltage dips/interruptions, EN61000-4-6 conducted RF and ENV50204 at 900 MHz are also referenced. Use the applicable manufacturer test report for precise conducted-RF and digital-phone test-level details. EMC tests used the unit on a 360 × 360 mm metal plate, 1 mm thick. This component is intended for installation in final equipment; reconfirm EMC compliance in the completed system. Weight and Reliability Catalogue single-unit reference 0.66 kg = 660 g per unit, from the PACKING entry. Carton reference 24 pieces / 16.8 kg / 1.17 CUFT; carton weight is not the per-unit product weight. MTBF, minimum 1679.6 K hours, Telcordia SR-332 (Bellcore); 213.8 K hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue edition MPQ-200-SPEC 2024-10-30; combined PDF pages 26–28. PACKING is a catalogue single-unit reference, not an independently weighed net or shipping mass. MTBF is a statistical estimate under the stated methods.

    $209.46

  • MPQ-200D

    MEAN WELL MPQ-200 series: Quad-Output Medical AC/DC Power Supply - MPQ-200D

    MEAN WELL MPQ-200D is a PCB-type four-output medical AC/DC power supply. It provides CH1 5 V, CH2 24 V, CH3 12 V, CH4 −12 V. The total continuous output is limited to 140 W with natural convection or 200 W with at least 25 CFM forced airflow, together with every channel limit and applicable derating. Product Datasheet Download MEAN WELL MPQ-200 Datasheet (PDF) The MPQ-200 section is on PDF pages 26, 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Configuration Complete model MPQ-200D Output arrangement 4 outputs sharing the stated COM reference; polarity is shown separately for every channel. Construction PCB assembly for installation inside equipment. Nominal efficiency, typical 79%. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. Combined Load and Peak Limits Total continuous output 140 W maximum with natural convection; 200 W maximum with 25 CFM forced air. Individual channel limits also apply. Peak-current operation The peak-current column requires a 25 CFM fan. Maximum duty cycle is 33% within every 30 seconds, with average output power not exceeding rated power. Channel 1 voltage adjustment −5% to +10% of nominal CH1 voltage via the potentiometer; for 5 V CH1 this calculates to 4.75–5.5 V. The channel maximums are not permission to load every output to its maximum simultaneously. Keep the sum of the absolute channel output powers within the applicable combined power limit and meet all minimum-load requirements. Negative output voltage denotes polarity, not negative delivered power. The peak-current table does not print a separate combined peak-wattage limit or an independent pulse-duration value. The per-channel peak limits must not be added together as an allowable combined peak load. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. CH1 Electrical Ratings Output voltage 5 V. Rated current 15 A. Minimum load 3 A. Convection maximum current 12 A. Current with 25 CFM fan 15 A. Peak current with 25 CFM fan 18 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH2 Electrical Ratings Output voltage 24 V. Rated current 3 A. Minimum load 0.3 A. Convection maximum current 2.3 A. Current with 25 CFM fan 3 A. Peak current with 25 CFM fan 3.6 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 180 mVp-p. Voltage tolerance ±8.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH3 Electrical Ratings Output voltage 12 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH4 Electrical Ratings Output voltage −12 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. Input and Start-Up Input range 90–264 VAC, 47–63 Hz, or 127–370 VDC. Apply low-input derating. Input current, typical 3.5 A at 115 VAC; 1.6 A at 230 VAC, at 60 Hz and full output load. Cold-start inrush, typical Less than 25 A at 115 VAC; less than 40 A at 230 VAC, limited by internal thermistors. Set-up / rise time 1000 / 20 ms at 230 VAC; 3000 / 20 ms at 115 VAC, full load. Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load. Switching-frequency reference 100 kHz. Power factor, typical >0.95 at 230 VAC and >0.98 at 115 VAC, full load. Protection Short circuit / overload Hiccup protection at 120–160% rated load, with automatic recovery after the fault is removed. Overvoltage protection CH1 only, at 115–135% of its rated voltage. The output shuts down when activated; the page does not specify a recovery method. Overtemperature protection TSW1 senses the power-transistor heat sink. At 95°C the output shuts down; it recovers automatically after temperature falls. This is a heat-sink sensor threshold, not an ambient-temperature rating. Protection thresholds are fault limits, not additional operating ratings. Control, Status and Remote Sense Power Good / Power Fail TTL high indicates power good; low indicates failure. At 90% of rated output voltage, the +5 V TTL signal is asserted after 10–500 ms. It goes low at least 1 ms before output falls below 90% of rated voltage. Remote ON/OFF Across RC+ and RC−: 0–0.8 V turns the output on; 4–10 V turns it off. The catalogue prints the sink-current reference as <4–10 mA; confirm interface drive requirements from the manufacturer application instructions. Remote sense CN4 pin 5 RS+ and pin 2 RS−. Observe the correct output polarity and the manufacturer wiring instructions; these pages do not state a maximum compensation voltage. Power indication The mechanical drawing marks the LED power indicator. The status signal is available at CN4 pin 1 PG with pin 3 GND. Remote control is on pin 4 RC+ and pin 6 RC−; these functions must not be inferred from the connector position alone. No standby output is specified for these four-output models. Derating and Environment Working temperature −20 to +70°C, subject to the cooling curve. Thermal curve Horizontal mounting: natural convection allows 70% of the 200 W family rating through 40°C, falling to 30% at 60°C. With 25 CFM forced air, 100% is available through 50°C, falling to 40% at 70°C. The no-fan curve ends at 60°C. Input-voltage curve, 60 Hz 80% load at 90 VAC; 100% at 115 VAC through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage conditions −40 to +85°C; 10–90% RH. Temperature coefficient ±0.04%/°C on all outputs at full load, over 0–50°C. Vibration 10–500 Hz, 2 G; 10-minute cycles, six cycles / 60 minutes along each X, Y and Z axis. Altitude condition Above 2000 m, reduce allowable ambient temperature by 3.5°C per additional 1000 m for fanless operation, or 5°C per additional 1000 m for fan-cooled operation. No absolute operating-altitude maximum is specified on these MPQ pages. Apply temperature, input-voltage, cooling and channel loading restrictions together. Do not extrapolate beyond the plotted curve or treat a series name as the guaranteed output wattage. Installation and Mechanical Details Dimensions, L × W × H 177.8 × 107.2 × 35.5 mm. Drawing dimensions Millimetres, general tolerance ±1 mm; 4 x Ø3.96 mm on 165.1 × 95.25 mm centres. Underside clearance 3 mm maximum component projection is shown below the board; allow the installation clearance required by the manufacturer. It is not a mounting-screw penetration rating. Mounting references Edge references 6.35 mm and 6.1 mm; the FG position is marked near the AC input. Forced-air installation At least 25 CFM, fan 15 cm from the illustrated board edge, with the shown airflow direction. Use the applicable complete mechanical drawing and installation instructions. The listed mating connector references, external fan and mounting hardware are not stated to be supplied accessories. Maintain the marked protective-ground connection and verify safety and EMC in the final equipment. Connectors and Mating References AC input CN1 JST B3P-VH or equivalent: pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing reference JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Main output CN2 and CN3 Two JST B8P-VH connectors or equivalents, using combined numbering 1–16: pins 1–4 V1; 5–11 COM; 12–13 V2; 14 V3; 15 absent; 16 V4. Use the signed channel voltages listed above. Signal connector CN4 JS-2008-03*2 or equivalent: 1 PG, 2 RS−, 3 GND, 4 RC+, 5 RS+, 6 RC−. Mating housing JS-2007-03*2; terminal JS-2007-T or equivalent. The main input/output connectors use the JST VHR housing family and JST SVH-21T-P1.1 contact reference. Select the complete mating housing for the required circuit count and wire size; loose mating parts and any external fan are not stated as included. Medical Isolation, Leakage and Safety Isolation level Primary–secondary: 2 MOPP. No additional MOPP levels are assigned here. Withstand voltage Input–output 4 kVAC; input–FG 2 kVAC; output–FG 1.5 kVAC. Insulation resistance Greater than 100 MΩ at 500 VDC, for input–output, input–FG and output–FG. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC. Touch current is measured from primary input to DC output. The safety table lists IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; and EAC TP TC004. The cover also carries UL60950-1. Verify the applicable component approval in the final equipment configuration. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. EMC and System Integration Conducted and radiated emissions: BS EN/EN55011 Class B. Harmonic current: BS EN/EN61000-3-2; voltage flicker: BS EN/EN61000-3-3; EAC TP TC020 is listed. The immunity table references EN61000-4-2 ESD: 8 kV air (Level 3) and 4 kV contact (Level 2); EN61000-4-3 RF field: 3 and 10 V/m; EN61000-4-4 EFT: 1 and 2 kV at 5 kHz; EN61000-4-5 surge: 2 kV line–line and 4 kV line–earth; EN61000-4-8 magnetic field: 3 and 10 A/m. EN61000-4-11 voltage dips/interruptions, EN61000-4-6 conducted RF and ENV50204 at 900 MHz are also referenced. Use the applicable manufacturer test report for precise conducted-RF and digital-phone test-level details. EMC tests used the unit on a 360 × 360 mm metal plate, 1 mm thick. This component is intended for installation in final equipment; reconfirm EMC compliance in the completed system. Weight and Reliability Catalogue single-unit reference 0.66 kg = 660 g per unit, from the PACKING entry. Carton reference 24 pieces / 16.8 kg / 1.17 CUFT; carton weight is not the per-unit product weight. MTBF, minimum 1679.6 K hours, Telcordia SR-332 (Bellcore); 213.8 K hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue edition MPQ-200-SPEC 2024-10-30; combined PDF pages 26–28. PACKING is a catalogue single-unit reference, not an independently weighed net or shipping mass. MTBF is a statistical estimate under the stated methods.

    $209.46

  • MPQ-200D

    MEAN WELL MPQ-200 series: Quad-Output Medical AC/DC Power Supply - MPQ-200D

    MEAN WELL MPQ-200D is a PCB-type four-output medical AC/DC power supply. It provides CH1 5 V, CH2 24 V, CH3 12 V, CH4 −12 V. The total continuous output is limited to 140 W with natural convection or 200 W with at least 25 CFM forced airflow, together with every channel limit and applicable derating. Product Datasheet Download MEAN WELL MPQ-200 Datasheet (PDF) The MPQ-200 section is on PDF pages 26, 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Configuration Complete model MPQ-200D Output arrangement 4 outputs sharing the stated COM reference; polarity is shown separately for every channel. Construction PCB assembly for installation inside equipment. Nominal efficiency, typical 79%. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. Combined Load and Peak Limits Total continuous output 140 W maximum with natural convection; 200 W maximum with 25 CFM forced air. Individual channel limits also apply. Peak-current operation The peak-current column requires a 25 CFM fan. Maximum duty cycle is 33% within every 30 seconds, with average output power not exceeding rated power. Channel 1 voltage adjustment −5% to +10% of nominal CH1 voltage via the potentiometer; for 5 V CH1 this calculates to 4.75–5.5 V. The channel maximums are not permission to load every output to its maximum simultaneously. Keep the sum of the absolute channel output powers within the applicable combined power limit and meet all minimum-load requirements. Negative output voltage denotes polarity, not negative delivered power. The peak-current table does not print a separate combined peak-wattage limit or an independent pulse-duration value. The per-channel peak limits must not be added together as an allowable combined peak load. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. CH1 Electrical Ratings Output voltage 5 V. Rated current 15 A. Minimum load 3 A. Convection maximum current 12 A. Current with 25 CFM fan 15 A. Peak current with 25 CFM fan 18 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH2 Electrical Ratings Output voltage 24 V. Rated current 3 A. Minimum load 0.3 A. Convection maximum current 2.3 A. Current with 25 CFM fan 3 A. Peak current with 25 CFM fan 3.6 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 180 mVp-p. Voltage tolerance ±8.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH3 Electrical Ratings Output voltage 12 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH4 Electrical Ratings Output voltage −12 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. Input and Start-Up Input range 90–264 VAC, 47–63 Hz, or 127–370 VDC. Apply low-input derating. Input current, typical 3.5 A at 115 VAC; 1.6 A at 230 VAC, at 60 Hz and full output load. Cold-start inrush, typical Less than 25 A at 115 VAC; less than 40 A at 230 VAC, limited by internal thermistors. Set-up / rise time 1000 / 20 ms at 230 VAC; 3000 / 20 ms at 115 VAC, full load. Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load. Switching-frequency reference 100 kHz. Power factor, typical >0.95 at 230 VAC and >0.98 at 115 VAC, full load. Protection Short circuit / overload Hiccup protection at 120–160% rated load, with automatic recovery after the fault is removed. Overvoltage protection CH1 only, at 115–135% of its rated voltage. The output shuts down when activated; the page does not specify a recovery method. Overtemperature protection TSW1 senses the power-transistor heat sink. At 95°C the output shuts down; it recovers automatically after temperature falls. This is a heat-sink sensor threshold, not an ambient-temperature rating. Protection thresholds are fault limits, not additional operating ratings. Control, Status and Remote Sense Power Good / Power Fail TTL high indicates power good; low indicates failure. At 90% of rated output voltage, the +5 V TTL signal is asserted after 10–500 ms. It goes low at least 1 ms before output falls below 90% of rated voltage. Remote ON/OFF Across RC+ and RC−: 0–0.8 V turns the output on; 4–10 V turns it off. The catalogue prints the sink-current reference as <4–10 mA; confirm interface drive requirements from the manufacturer application instructions. Remote sense CN4 pin 5 RS+ and pin 2 RS−. Observe the correct output polarity and the manufacturer wiring instructions; these pages do not state a maximum compensation voltage. Power indication The mechanical drawing marks the LED power indicator. The status signal is available at CN4 pin 1 PG with pin 3 GND. Remote control is on pin 4 RC+ and pin 6 RC−; these functions must not be inferred from the connector position alone. No standby output is specified for these four-output models. Derating and Environment Working temperature −20 to +70°C, subject to the cooling curve. Thermal curve Horizontal mounting: natural convection allows 70% of the 200 W family rating through 40°C, falling to 30% at 60°C. With 25 CFM forced air, 100% is available through 50°C, falling to 40% at 70°C. The no-fan curve ends at 60°C. Input-voltage curve, 60 Hz 80% load at 90 VAC; 100% at 115 VAC through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage conditions −40 to +85°C; 10–90% RH. Temperature coefficient ±0.04%/°C on all outputs at full load, over 0–50°C. Vibration 10–500 Hz, 2 G; 10-minute cycles, six cycles / 60 minutes along each X, Y and Z axis. Altitude condition Above 2000 m, reduce allowable ambient temperature by 3.5°C per additional 1000 m for fanless operation, or 5°C per additional 1000 m for fan-cooled operation. No absolute operating-altitude maximum is specified on these MPQ pages. Apply temperature, input-voltage, cooling and channel loading restrictions together. Do not extrapolate beyond the plotted curve or treat a series name as the guaranteed output wattage. Installation and Mechanical Details Dimensions, L × W × H 177.8 × 107.2 × 35.5 mm. Drawing dimensions Millimetres, general tolerance ±1 mm; 4 x Ø3.96 mm on 165.1 × 95.25 mm centres. Underside clearance 3 mm maximum component projection is shown below the board; allow the installation clearance required by the manufacturer. It is not a mounting-screw penetration rating. Mounting references Edge references 6.35 mm and 6.1 mm; the FG position is marked near the AC input. Forced-air installation At least 25 CFM, fan 15 cm from the illustrated board edge, with the shown airflow direction. Use the applicable complete mechanical drawing and installation instructions. The listed mating connector references, external fan and mounting hardware are not stated to be supplied accessories. Maintain the marked protective-ground connection and verify safety and EMC in the final equipment. Connectors and Mating References AC input CN1 JST B3P-VH or equivalent: pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing reference JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Main output CN2 and CN3 Two JST B8P-VH connectors or equivalents, using combined numbering 1–16: pins 1–4 V1; 5–11 COM; 12–13 V2; 14 V3; 15 absent; 16 V4. Use the signed channel voltages listed above. Signal connector CN4 JS-2008-03*2 or equivalent: 1 PG, 2 RS−, 3 GND, 4 RC+, 5 RS+, 6 RC−. Mating housing JS-2007-03*2; terminal JS-2007-T or equivalent. The main input/output connectors use the JST VHR housing family and JST SVH-21T-P1.1 contact reference. Select the complete mating housing for the required circuit count and wire size; loose mating parts and any external fan are not stated as included. Medical Isolation, Leakage and Safety Isolation level Primary–secondary: 2 MOPP. No additional MOPP levels are assigned here. Withstand voltage Input–output 4 kVAC; input–FG 2 kVAC; output–FG 1.5 kVAC. Insulation resistance Greater than 100 MΩ at 500 VDC, for input–output, input–FG and output–FG. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC. Touch current is measured from primary input to DC output. The safety table lists IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; and EAC TP TC004. The cover also carries UL60950-1. Verify the applicable component approval in the final equipment configuration. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. EMC and System Integration Conducted and radiated emissions: BS EN/EN55011 Class B. Harmonic current: BS EN/EN61000-3-2; voltage flicker: BS EN/EN61000-3-3; EAC TP TC020 is listed. The immunity table references EN61000-4-2 ESD: 8 kV air (Level 3) and 4 kV contact (Level 2); EN61000-4-3 RF field: 3 and 10 V/m; EN61000-4-4 EFT: 1 and 2 kV at 5 kHz; EN61000-4-5 surge: 2 kV line–line and 4 kV line–earth; EN61000-4-8 magnetic field: 3 and 10 A/m. EN61000-4-11 voltage dips/interruptions, EN61000-4-6 conducted RF and ENV50204 at 900 MHz are also referenced. Use the applicable manufacturer test report for precise conducted-RF and digital-phone test-level details. EMC tests used the unit on a 360 × 360 mm metal plate, 1 mm thick. This component is intended for installation in final equipment; reconfirm EMC compliance in the completed system. Weight and Reliability Catalogue single-unit reference 0.66 kg = 660 g per unit, from the PACKING entry. Carton reference 24 pieces / 16.8 kg / 1.17 CUFT; carton weight is not the per-unit product weight. MTBF, minimum 1679.6 K hours, Telcordia SR-332 (Bellcore); 213.8 K hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue edition MPQ-200-SPEC 2024-10-30; combined PDF pages 26–28. PACKING is a catalogue single-unit reference, not an independently weighed net or shipping mass. MTBF is a statistical estimate under the stated methods.

    $209.46

  • MPQ-200D

    MEAN WELL MPQ-200 series: Quad-Output Medical AC/DC Power Supply - MPQ-200D

    MEAN WELL MPQ-200D is a PCB-type four-output medical AC/DC power supply. It provides CH1 5 V, CH2 24 V, CH3 12 V, CH4 −12 V. The total continuous output is limited to 140 W with natural convection or 200 W with at least 25 CFM forced airflow, together with every channel limit and applicable derating. Product Datasheet Download MEAN WELL MPQ-200 Datasheet (PDF) The MPQ-200 section is on PDF pages 26, 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Configuration Complete model MPQ-200D Output arrangement 4 outputs sharing the stated COM reference; polarity is shown separately for every channel. Construction PCB assembly for installation inside equipment. Nominal efficiency, typical 79%. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. Combined Load and Peak Limits Total continuous output 140 W maximum with natural convection; 200 W maximum with 25 CFM forced air. Individual channel limits also apply. Peak-current operation The peak-current column requires a 25 CFM fan. Maximum duty cycle is 33% within every 30 seconds, with average output power not exceeding rated power. Channel 1 voltage adjustment −5% to +10% of nominal CH1 voltage via the potentiometer; for 5 V CH1 this calculates to 4.75–5.5 V. The channel maximums are not permission to load every output to its maximum simultaneously. Keep the sum of the absolute channel output powers within the applicable combined power limit and meet all minimum-load requirements. Negative output voltage denotes polarity, not negative delivered power. The peak-current table does not print a separate combined peak-wattage limit or an independent pulse-duration value. The per-channel peak limits must not be added together as an allowable combined peak load. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. CH1 Electrical Ratings Output voltage 5 V. Rated current 15 A. Minimum load 3 A. Convection maximum current 12 A. Current with 25 CFM fan 15 A. Peak current with 25 CFM fan 18 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH2 Electrical Ratings Output voltage 24 V. Rated current 3 A. Minimum load 0.3 A. Convection maximum current 2.3 A. Current with 25 CFM fan 3 A. Peak current with 25 CFM fan 3.6 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 180 mVp-p. Voltage tolerance ±8.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH3 Electrical Ratings Output voltage 12 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH4 Electrical Ratings Output voltage −12 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. Input and Start-Up Input range 90–264 VAC, 47–63 Hz, or 127–370 VDC. Apply low-input derating. Input current, typical 3.5 A at 115 VAC; 1.6 A at 230 VAC, at 60 Hz and full output load. Cold-start inrush, typical Less than 25 A at 115 VAC; less than 40 A at 230 VAC, limited by internal thermistors. Set-up / rise time 1000 / 20 ms at 230 VAC; 3000 / 20 ms at 115 VAC, full load. Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load. Switching-frequency reference 100 kHz. Power factor, typical >0.95 at 230 VAC and >0.98 at 115 VAC, full load. Protection Short circuit / overload Hiccup protection at 120–160% rated load, with automatic recovery after the fault is removed. Overvoltage protection CH1 only, at 115–135% of its rated voltage. The output shuts down when activated; the page does not specify a recovery method. Overtemperature protection TSW1 senses the power-transistor heat sink. At 95°C the output shuts down; it recovers automatically after temperature falls. This is a heat-sink sensor threshold, not an ambient-temperature rating. Protection thresholds are fault limits, not additional operating ratings. Control, Status and Remote Sense Power Good / Power Fail TTL high indicates power good; low indicates failure. At 90% of rated output voltage, the +5 V TTL signal is asserted after 10–500 ms. It goes low at least 1 ms before output falls below 90% of rated voltage. Remote ON/OFF Across RC+ and RC−: 0–0.8 V turns the output on; 4–10 V turns it off. The catalogue prints the sink-current reference as <4–10 mA; confirm interface drive requirements from the manufacturer application instructions. Remote sense CN4 pin 5 RS+ and pin 2 RS−. Observe the correct output polarity and the manufacturer wiring instructions; these pages do not state a maximum compensation voltage. Power indication The mechanical drawing marks the LED power indicator. The status signal is available at CN4 pin 1 PG with pin 3 GND. Remote control is on pin 4 RC+ and pin 6 RC−; these functions must not be inferred from the connector position alone. No standby output is specified for these four-output models. Derating and Environment Working temperature −20 to +70°C, subject to the cooling curve. Thermal curve Horizontal mounting: natural convection allows 70% of the 200 W family rating through 40°C, falling to 30% at 60°C. With 25 CFM forced air, 100% is available through 50°C, falling to 40% at 70°C. The no-fan curve ends at 60°C. Input-voltage curve, 60 Hz 80% load at 90 VAC; 100% at 115 VAC through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage conditions −40 to +85°C; 10–90% RH. Temperature coefficient ±0.04%/°C on all outputs at full load, over 0–50°C. Vibration 10–500 Hz, 2 G; 10-minute cycles, six cycles / 60 minutes along each X, Y and Z axis. Altitude condition Above 2000 m, reduce allowable ambient temperature by 3.5°C per additional 1000 m for fanless operation, or 5°C per additional 1000 m for fan-cooled operation. No absolute operating-altitude maximum is specified on these MPQ pages. Apply temperature, input-voltage, cooling and channel loading restrictions together. Do not extrapolate beyond the plotted curve or treat a series name as the guaranteed output wattage. Installation and Mechanical Details Dimensions, L × W × H 177.8 × 107.2 × 35.5 mm. Drawing dimensions Millimetres, general tolerance ±1 mm; 4 x Ø3.96 mm on 165.1 × 95.25 mm centres. Underside clearance 3 mm maximum component projection is shown below the board; allow the installation clearance required by the manufacturer. It is not a mounting-screw penetration rating. Mounting references Edge references 6.35 mm and 6.1 mm; the FG position is marked near the AC input. Forced-air installation At least 25 CFM, fan 15 cm from the illustrated board edge, with the shown airflow direction. Use the applicable complete mechanical drawing and installation instructions. The listed mating connector references, external fan and mounting hardware are not stated to be supplied accessories. Maintain the marked protective-ground connection and verify safety and EMC in the final equipment. Connectors and Mating References AC input CN1 JST B3P-VH or equivalent: pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing reference JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Main output CN2 and CN3 Two JST B8P-VH connectors or equivalents, using combined numbering 1–16: pins 1–4 V1; 5–11 COM; 12–13 V2; 14 V3; 15 absent; 16 V4. Use the signed channel voltages listed above. Signal connector CN4 JS-2008-03*2 or equivalent: 1 PG, 2 RS−, 3 GND, 4 RC+, 5 RS+, 6 RC−. Mating housing JS-2007-03*2; terminal JS-2007-T or equivalent. The main input/output connectors use the JST VHR housing family and JST SVH-21T-P1.1 contact reference. Select the complete mating housing for the required circuit count and wire size; loose mating parts and any external fan are not stated as included. Medical Isolation, Leakage and Safety Isolation level Primary–secondary: 2 MOPP. No additional MOPP levels are assigned here. Withstand voltage Input–output 4 kVAC; input–FG 2 kVAC; output–FG 1.5 kVAC. Insulation resistance Greater than 100 MΩ at 500 VDC, for input–output, input–FG and output–FG. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC. Touch current is measured from primary input to DC output. The safety table lists IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; and EAC TP TC004. The cover also carries UL60950-1. Verify the applicable component approval in the final equipment configuration. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. EMC and System Integration Conducted and radiated emissions: BS EN/EN55011 Class B. Harmonic current: BS EN/EN61000-3-2; voltage flicker: BS EN/EN61000-3-3; EAC TP TC020 is listed. The immunity table references EN61000-4-2 ESD: 8 kV air (Level 3) and 4 kV contact (Level 2); EN61000-4-3 RF field: 3 and 10 V/m; EN61000-4-4 EFT: 1 and 2 kV at 5 kHz; EN61000-4-5 surge: 2 kV line–line and 4 kV line–earth; EN61000-4-8 magnetic field: 3 and 10 A/m. EN61000-4-11 voltage dips/interruptions, EN61000-4-6 conducted RF and ENV50204 at 900 MHz are also referenced. Use the applicable manufacturer test report for precise conducted-RF and digital-phone test-level details. EMC tests used the unit on a 360 × 360 mm metal plate, 1 mm thick. This component is intended for installation in final equipment; reconfirm EMC compliance in the completed system. Weight and Reliability Catalogue single-unit reference 0.66 kg = 660 g per unit, from the PACKING entry. Carton reference 24 pieces / 16.8 kg / 1.17 CUFT; carton weight is not the per-unit product weight. MTBF, minimum 1679.6 K hours, Telcordia SR-332 (Bellcore); 213.8 K hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue edition MPQ-200-SPEC 2024-10-30; combined PDF pages 26–28. PACKING is a catalogue single-unit reference, not an independently weighed net or shipping mass. MTBF is a statistical estimate under the stated methods.

    $209.46

  • MPQ-200D

    MEAN WELL MPQ-200 series: Quad-Output Medical AC/DC Power Supply - MPQ-200D

    MEAN WELL MPQ-200D is a PCB-type four-output medical AC/DC power supply. It provides CH1 5 V, CH2 24 V, CH3 12 V, CH4 −12 V. The total continuous output is limited to 140 W with natural convection or 200 W with at least 25 CFM forced airflow, together with every channel limit and applicable derating. Product Datasheet Download MEAN WELL MPQ-200 Datasheet (PDF) The MPQ-200 section is on PDF pages 26, 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Configuration Complete model MPQ-200D Output arrangement 4 outputs sharing the stated COM reference; polarity is shown separately for every channel. Construction PCB assembly for installation inside equipment. Nominal efficiency, typical 79%. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. Combined Load and Peak Limits Total continuous output 140 W maximum with natural convection; 200 W maximum with 25 CFM forced air. Individual channel limits also apply. Peak-current operation The peak-current column requires a 25 CFM fan. Maximum duty cycle is 33% within every 30 seconds, with average output power not exceeding rated power. Channel 1 voltage adjustment −5% to +10% of nominal CH1 voltage via the potentiometer; for 5 V CH1 this calculates to 4.75–5.5 V. The channel maximums are not permission to load every output to its maximum simultaneously. Keep the sum of the absolute channel output powers within the applicable combined power limit and meet all minimum-load requirements. Negative output voltage denotes polarity, not negative delivered power. The peak-current table does not print a separate combined peak-wattage limit or an independent pulse-duration value. The per-channel peak limits must not be added together as an allowable combined peak load. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. CH1 Electrical Ratings Output voltage 5 V. Rated current 15 A. Minimum load 3 A. Convection maximum current 12 A. Current with 25 CFM fan 15 A. Peak current with 25 CFM fan 18 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH2 Electrical Ratings Output voltage 24 V. Rated current 3 A. Minimum load 0.3 A. Convection maximum current 2.3 A. Current with 25 CFM fan 3 A. Peak current with 25 CFM fan 3.6 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 180 mVp-p. Voltage tolerance ±8.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH3 Electrical Ratings Output voltage 12 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH4 Electrical Ratings Output voltage −12 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. Input and Start-Up Input range 90–264 VAC, 47–63 Hz, or 127–370 VDC. Apply low-input derating. Input current, typical 3.5 A at 115 VAC; 1.6 A at 230 VAC, at 60 Hz and full output load. Cold-start inrush, typical Less than 25 A at 115 VAC; less than 40 A at 230 VAC, limited by internal thermistors. Set-up / rise time 1000 / 20 ms at 230 VAC; 3000 / 20 ms at 115 VAC, full load. Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load. Switching-frequency reference 100 kHz. Power factor, typical >0.95 at 230 VAC and >0.98 at 115 VAC, full load. Protection Short circuit / overload Hiccup protection at 120–160% rated load, with automatic recovery after the fault is removed. Overvoltage protection CH1 only, at 115–135% of its rated voltage. The output shuts down when activated; the page does not specify a recovery method. Overtemperature protection TSW1 senses the power-transistor heat sink. At 95°C the output shuts down; it recovers automatically after temperature falls. This is a heat-sink sensor threshold, not an ambient-temperature rating. Protection thresholds are fault limits, not additional operating ratings. Control, Status and Remote Sense Power Good / Power Fail TTL high indicates power good; low indicates failure. At 90% of rated output voltage, the +5 V TTL signal is asserted after 10–500 ms. It goes low at least 1 ms before output falls below 90% of rated voltage. Remote ON/OFF Across RC+ and RC−: 0–0.8 V turns the output on; 4–10 V turns it off. The catalogue prints the sink-current reference as <4–10 mA; confirm interface drive requirements from the manufacturer application instructions. Remote sense CN4 pin 5 RS+ and pin 2 RS−. Observe the correct output polarity and the manufacturer wiring instructions; these pages do not state a maximum compensation voltage. Power indication The mechanical drawing marks the LED power indicator. The status signal is available at CN4 pin 1 PG with pin 3 GND. Remote control is on pin 4 RC+ and pin 6 RC−; these functions must not be inferred from the connector position alone. No standby output is specified for these four-output models. Derating and Environment Working temperature −20 to +70°C, subject to the cooling curve. Thermal curve Horizontal mounting: natural convection allows 70% of the 200 W family rating through 40°C, falling to 30% at 60°C. With 25 CFM forced air, 100% is available through 50°C, falling to 40% at 70°C. The no-fan curve ends at 60°C. Input-voltage curve, 60 Hz 80% load at 90 VAC; 100% at 115 VAC through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage conditions −40 to +85°C; 10–90% RH. Temperature coefficient ±0.04%/°C on all outputs at full load, over 0–50°C. Vibration 10–500 Hz, 2 G; 10-minute cycles, six cycles / 60 minutes along each X, Y and Z axis. Altitude condition Above 2000 m, reduce allowable ambient temperature by 3.5°C per additional 1000 m for fanless operation, or 5°C per additional 1000 m for fan-cooled operation. No absolute operating-altitude maximum is specified on these MPQ pages. Apply temperature, input-voltage, cooling and channel loading restrictions together. Do not extrapolate beyond the plotted curve or treat a series name as the guaranteed output wattage. Installation and Mechanical Details Dimensions, L × W × H 177.8 × 107.2 × 35.5 mm. Drawing dimensions Millimetres, general tolerance ±1 mm; 4 x Ø3.96 mm on 165.1 × 95.25 mm centres. Underside clearance 3 mm maximum component projection is shown below the board; allow the installation clearance required by the manufacturer. It is not a mounting-screw penetration rating. Mounting references Edge references 6.35 mm and 6.1 mm; the FG position is marked near the AC input. Forced-air installation At least 25 CFM, fan 15 cm from the illustrated board edge, with the shown airflow direction. Use the applicable complete mechanical drawing and installation instructions. The listed mating connector references, external fan and mounting hardware are not stated to be supplied accessories. Maintain the marked protective-ground connection and verify safety and EMC in the final equipment. Connectors and Mating References AC input CN1 JST B3P-VH or equivalent: pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing reference JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Main output CN2 and CN3 Two JST B8P-VH connectors or equivalents, using combined numbering 1–16: pins 1–4 V1; 5–11 COM; 12–13 V2; 14 V3; 15 absent; 16 V4. Use the signed channel voltages listed above. Signal connector CN4 JS-2008-03*2 or equivalent: 1 PG, 2 RS−, 3 GND, 4 RC+, 5 RS+, 6 RC−. Mating housing JS-2007-03*2; terminal JS-2007-T or equivalent. The main input/output connectors use the JST VHR housing family and JST SVH-21T-P1.1 contact reference. Select the complete mating housing for the required circuit count and wire size; loose mating parts and any external fan are not stated as included. Medical Isolation, Leakage and Safety Isolation level Primary–secondary: 2 MOPP. No additional MOPP levels are assigned here. Withstand voltage Input–output 4 kVAC; input–FG 2 kVAC; output–FG 1.5 kVAC. Insulation resistance Greater than 100 MΩ at 500 VDC, for input–output, input–FG and output–FG. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC. Touch current is measured from primary input to DC output. The safety table lists IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; and EAC TP TC004. The cover also carries UL60950-1. Verify the applicable component approval in the final equipment configuration. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. EMC and System Integration Conducted and radiated emissions: BS EN/EN55011 Class B. Harmonic current: BS EN/EN61000-3-2; voltage flicker: BS EN/EN61000-3-3; EAC TP TC020 is listed. The immunity table references EN61000-4-2 ESD: 8 kV air (Level 3) and 4 kV contact (Level 2); EN61000-4-3 RF field: 3 and 10 V/m; EN61000-4-4 EFT: 1 and 2 kV at 5 kHz; EN61000-4-5 surge: 2 kV line–line and 4 kV line–earth; EN61000-4-8 magnetic field: 3 and 10 A/m. EN61000-4-11 voltage dips/interruptions, EN61000-4-6 conducted RF and ENV50204 at 900 MHz are also referenced. Use the applicable manufacturer test report for precise conducted-RF and digital-phone test-level details. EMC tests used the unit on a 360 × 360 mm metal plate, 1 mm thick. This component is intended for installation in final equipment; reconfirm EMC compliance in the completed system. Weight and Reliability Catalogue single-unit reference 0.66 kg = 660 g per unit, from the PACKING entry. Carton reference 24 pieces / 16.8 kg / 1.17 CUFT; carton weight is not the per-unit product weight. MTBF, minimum 1679.6 K hours, Telcordia SR-332 (Bellcore); 213.8 K hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue edition MPQ-200-SPEC 2024-10-30; combined PDF pages 26–28. PACKING is a catalogue single-unit reference, not an independently weighed net or shipping mass. MTBF is a statistical estimate under the stated methods.

    $209.46

  • MPQ-200C

    MEAN WELL MPQ-200 series: Quad-Output Medical AC/DC Power Supply - MPQ-200C

    MEAN WELL MPQ-200C is a PCB-type four-output medical AC/DC power supply. It provides CH1 5 V, CH2 15 V, CH3 −5 V, CH4 −15 V. The total continuous output is limited to 140 W with natural convection or 200 W with at least 25 CFM forced airflow, together with every channel limit and applicable derating. Product Datasheet Download MEAN WELL MPQ-200 Datasheet (PDF) The MPQ-200 section is on PDF pages 26, 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Configuration Complete model MPQ-200C Output arrangement 4 outputs sharing the stated COM reference; polarity is shown separately for every channel. Construction PCB assembly for installation inside equipment. Nominal efficiency, typical 78%. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. Combined Load and Peak Limits Total continuous output 140 W maximum with natural convection; 200 W maximum with 25 CFM forced air. Individual channel limits also apply. Peak-current operation The peak-current column requires a 25 CFM fan. Maximum duty cycle is 33% within every 30 seconds, with average output power not exceeding rated power. Channel 1 voltage adjustment −5% to +10% of nominal CH1 voltage via the potentiometer; for 5 V CH1 this calculates to 4.75–5.5 V. The channel maximums are not permission to load every output to its maximum simultaneously. Keep the sum of the absolute channel output powers within the applicable combined power limit and meet all minimum-load requirements. Negative output voltage denotes polarity, not negative delivered power. The peak-current table does not print a separate combined peak-wattage limit or an independent pulse-duration value. The per-channel peak limits must not be added together as an allowable combined peak load. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. CH1 Electrical Ratings Output voltage 5 V. Rated current 15 A. Minimum load 3 A. Convection maximum current 12 A. Current with 25 CFM fan 15 A. Peak current with 25 CFM fan 18 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH2 Electrical Ratings Output voltage 15 V. Rated current 5 A. Minimum load 0.5 A. Convection maximum current 4 A. Current with 25 CFM fan 5 A. Peak current with 25 CFM fan 6 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 150 mVp-p. Voltage tolerance ±6.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH3 Electrical Ratings Output voltage −5 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH4 Electrical Ratings Output voltage −15 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. Input and Start-Up Input range 90–264 VAC, 47–63 Hz, or 127–370 VDC. Apply low-input derating. Input current, typical 3.5 A at 115 VAC; 1.6 A at 230 VAC, at 60 Hz and full output load. Cold-start inrush, typical Less than 25 A at 115 VAC; less than 40 A at 230 VAC, limited by internal thermistors. Set-up / rise time 1000 / 20 ms at 230 VAC; 3000 / 20 ms at 115 VAC, full load. Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load. Switching-frequency reference 100 kHz. Power factor, typical >0.95 at 230 VAC and >0.98 at 115 VAC, full load. Protection Short circuit / overload Hiccup protection at 120–160% rated load, with automatic recovery after the fault is removed. Overvoltage protection CH1 only, at 115–135% of its rated voltage. The output shuts down when activated; the page does not specify a recovery method. Overtemperature protection TSW1 senses the power-transistor heat sink. At 95°C the output shuts down; it recovers automatically after temperature falls. This is a heat-sink sensor threshold, not an ambient-temperature rating. Protection thresholds are fault limits, not additional operating ratings. Control, Status and Remote Sense Power Good / Power Fail TTL high indicates power good; low indicates failure. At 90% of rated output voltage, the +5 V TTL signal is asserted after 10–500 ms. It goes low at least 1 ms before output falls below 90% of rated voltage. Remote ON/OFF Across RC+ and RC−: 0–0.8 V turns the output on; 4–10 V turns it off. The catalogue prints the sink-current reference as <4–10 mA; confirm interface drive requirements from the manufacturer application instructions. Remote sense CN4 pin 5 RS+ and pin 2 RS−. Observe the correct output polarity and the manufacturer wiring instructions; these pages do not state a maximum compensation voltage. Power indication The mechanical drawing marks the LED power indicator. The status signal is available at CN4 pin 1 PG with pin 3 GND. Remote control is on pin 4 RC+ and pin 6 RC−; these functions must not be inferred from the connector position alone. No standby output is specified for these four-output models. Derating and Environment Working temperature −20 to +70°C, subject to the cooling curve. Thermal curve Horizontal mounting: natural convection allows 70% of the 200 W family rating through 40°C, falling to 30% at 60°C. With 25 CFM forced air, 100% is available through 50°C, falling to 40% at 70°C. The no-fan curve ends at 60°C. Input-voltage curve, 60 Hz 80% load at 90 VAC; 100% at 115 VAC through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage conditions −40 to +85°C; 10–90% RH. Temperature coefficient ±0.04%/°C on all outputs at full load, over 0–50°C. Vibration 10–500 Hz, 2 G; 10-minute cycles, six cycles / 60 minutes along each X, Y and Z axis. Altitude condition Above 2000 m, reduce allowable ambient temperature by 3.5°C per additional 1000 m for fanless operation, or 5°C per additional 1000 m for fan-cooled operation. No absolute operating-altitude maximum is specified on these MPQ pages. Apply temperature, input-voltage, cooling and channel loading restrictions together. Do not extrapolate beyond the plotted curve or treat a series name as the guaranteed output wattage. Installation and Mechanical Details Dimensions, L × W × H 177.8 × 107.2 × 35.5 mm. Drawing dimensions Millimetres, general tolerance ±1 mm; 4 x Ø3.96 mm on 165.1 × 95.25 mm centres. Underside clearance 3 mm maximum component projection is shown below the board; allow the installation clearance required by the manufacturer. It is not a mounting-screw penetration rating. Mounting references Edge references 6.35 mm and 6.1 mm; the FG position is marked near the AC input. Forced-air installation At least 25 CFM, fan 15 cm from the illustrated board edge, with the shown airflow direction. Use the applicable complete mechanical drawing and installation instructions. The listed mating connector references, external fan and mounting hardware are not stated to be supplied accessories. Maintain the marked protective-ground connection and verify safety and EMC in the final equipment. Connectors and Mating References AC input CN1 JST B3P-VH or equivalent: pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing reference JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Main output CN2 and CN3 Two JST B8P-VH connectors or equivalents, using combined numbering 1–16: pins 1–4 V1; 5–11 COM; 12–13 V2; 14 V3; 15 absent; 16 V4. Use the signed channel voltages listed above. Signal connector CN4 JS-2008-03*2 or equivalent: 1 PG, 2 RS−, 3 GND, 4 RC+, 5 RS+, 6 RC−. Mating housing JS-2007-03*2; terminal JS-2007-T or equivalent. The main input/output connectors use the JST VHR housing family and JST SVH-21T-P1.1 contact reference. Select the complete mating housing for the required circuit count and wire size; loose mating parts and any external fan are not stated as included. Medical Isolation, Leakage and Safety Isolation level Primary–secondary: 2 MOPP. No additional MOPP levels are assigned here. Withstand voltage Input–output 4 kVAC; input–FG 2 kVAC; output–FG 1.5 kVAC. Insulation resistance Greater than 100 MΩ at 500 VDC, for input–output, input–FG and output–FG. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC. Touch current is measured from primary input to DC output. The safety table lists IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; and EAC TP TC004. The cover also carries UL60950-1. Verify the applicable component approval in the final equipment configuration. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. EMC and System Integration Conducted and radiated emissions: BS EN/EN55011 Class B. Harmonic current: BS EN/EN61000-3-2; voltage flicker: BS EN/EN61000-3-3; EAC TP TC020 is listed. The immunity table references EN61000-4-2 ESD: 8 kV air (Level 3) and 4 kV contact (Level 2); EN61000-4-3 RF field: 3 and 10 V/m; EN61000-4-4 EFT: 1 and 2 kV at 5 kHz; EN61000-4-5 surge: 2 kV line–line and 4 kV line–earth; EN61000-4-8 magnetic field: 3 and 10 A/m. EN61000-4-11 voltage dips/interruptions, EN61000-4-6 conducted RF and ENV50204 at 900 MHz are also referenced. Use the applicable manufacturer test report for precise conducted-RF and digital-phone test-level details. EMC tests used the unit on a 360 × 360 mm metal plate, 1 mm thick. This component is intended for installation in final equipment; reconfirm EMC compliance in the completed system. Weight and Reliability Catalogue single-unit reference 0.66 kg = 660 g per unit, from the PACKING entry. Carton reference 24 pieces / 16.8 kg / 1.17 CUFT; carton weight is not the per-unit product weight. MTBF, minimum 1679.6 K hours, Telcordia SR-332 (Bellcore); 213.8 K hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue edition MPQ-200-SPEC 2024-10-30; combined PDF pages 26–28. PACKING is a catalogue single-unit reference, not an independently weighed net or shipping mass. MTBF is a statistical estimate under the stated methods.

    $209.46

  • MPQ-200C

    MEAN WELL MPQ-200 series: Quad-Output Medical AC/DC Power Supply - MPQ-200C

    MEAN WELL MPQ-200C is a PCB-type four-output medical AC/DC power supply. It provides CH1 5 V, CH2 15 V, CH3 −5 V, CH4 −15 V. The total continuous output is limited to 140 W with natural convection or 200 W with at least 25 CFM forced airflow, together with every channel limit and applicable derating. Product Datasheet Download MEAN WELL MPQ-200 Datasheet (PDF) The MPQ-200 section is on PDF pages 26, 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Configuration Complete model MPQ-200C Output arrangement 4 outputs sharing the stated COM reference; polarity is shown separately for every channel. Construction PCB assembly for installation inside equipment. Nominal efficiency, typical 78%. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. Combined Load and Peak Limits Total continuous output 140 W maximum with natural convection; 200 W maximum with 25 CFM forced air. Individual channel limits also apply. Peak-current operation The peak-current column requires a 25 CFM fan. Maximum duty cycle is 33% within every 30 seconds, with average output power not exceeding rated power. Channel 1 voltage adjustment −5% to +10% of nominal CH1 voltage via the potentiometer; for 5 V CH1 this calculates to 4.75–5.5 V. The channel maximums are not permission to load every output to its maximum simultaneously. Keep the sum of the absolute channel output powers within the applicable combined power limit and meet all minimum-load requirements. Negative output voltage denotes polarity, not negative delivered power. The peak-current table does not print a separate combined peak-wattage limit or an independent pulse-duration value. The per-channel peak limits must not be added together as an allowable combined peak load. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. CH1 Electrical Ratings Output voltage 5 V. Rated current 15 A. Minimum load 3 A. Convection maximum current 12 A. Current with 25 CFM fan 15 A. Peak current with 25 CFM fan 18 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH2 Electrical Ratings Output voltage 15 V. Rated current 5 A. Minimum load 0.5 A. Convection maximum current 4 A. Current with 25 CFM fan 5 A. Peak current with 25 CFM fan 6 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 150 mVp-p. Voltage tolerance ±6.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH3 Electrical Ratings Output voltage −5 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH4 Electrical Ratings Output voltage −15 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. Input and Start-Up Input range 90–264 VAC, 47–63 Hz, or 127–370 VDC. Apply low-input derating. Input current, typical 3.5 A at 115 VAC; 1.6 A at 230 VAC, at 60 Hz and full output load. Cold-start inrush, typical Less than 25 A at 115 VAC; less than 40 A at 230 VAC, limited by internal thermistors. Set-up / rise time 1000 / 20 ms at 230 VAC; 3000 / 20 ms at 115 VAC, full load. Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load. Switching-frequency reference 100 kHz. Power factor, typical >0.95 at 230 VAC and >0.98 at 115 VAC, full load. Protection Short circuit / overload Hiccup protection at 120–160% rated load, with automatic recovery after the fault is removed. Overvoltage protection CH1 only, at 115–135% of its rated voltage. The output shuts down when activated; the page does not specify a recovery method. Overtemperature protection TSW1 senses the power-transistor heat sink. At 95°C the output shuts down; it recovers automatically after temperature falls. This is a heat-sink sensor threshold, not an ambient-temperature rating. Protection thresholds are fault limits, not additional operating ratings. Control, Status and Remote Sense Power Good / Power Fail TTL high indicates power good; low indicates failure. At 90% of rated output voltage, the +5 V TTL signal is asserted after 10–500 ms. It goes low at least 1 ms before output falls below 90% of rated voltage. Remote ON/OFF Across RC+ and RC−: 0–0.8 V turns the output on; 4–10 V turns it off. The catalogue prints the sink-current reference as <4–10 mA; confirm interface drive requirements from the manufacturer application instructions. Remote sense CN4 pin 5 RS+ and pin 2 RS−. Observe the correct output polarity and the manufacturer wiring instructions; these pages do not state a maximum compensation voltage. Power indication The mechanical drawing marks the LED power indicator. The status signal is available at CN4 pin 1 PG with pin 3 GND. Remote control is on pin 4 RC+ and pin 6 RC−; these functions must not be inferred from the connector position alone. No standby output is specified for these four-output models. Derating and Environment Working temperature −20 to +70°C, subject to the cooling curve. Thermal curve Horizontal mounting: natural convection allows 70% of the 200 W family rating through 40°C, falling to 30% at 60°C. With 25 CFM forced air, 100% is available through 50°C, falling to 40% at 70°C. The no-fan curve ends at 60°C. Input-voltage curve, 60 Hz 80% load at 90 VAC; 100% at 115 VAC through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage conditions −40 to +85°C; 10–90% RH. Temperature coefficient ±0.04%/°C on all outputs at full load, over 0–50°C. Vibration 10–500 Hz, 2 G; 10-minute cycles, six cycles / 60 minutes along each X, Y and Z axis. Altitude condition Above 2000 m, reduce allowable ambient temperature by 3.5°C per additional 1000 m for fanless operation, or 5°C per additional 1000 m for fan-cooled operation. No absolute operating-altitude maximum is specified on these MPQ pages. Apply temperature, input-voltage, cooling and channel loading restrictions together. Do not extrapolate beyond the plotted curve or treat a series name as the guaranteed output wattage. Installation and Mechanical Details Dimensions, L × W × H 177.8 × 107.2 × 35.5 mm. Drawing dimensions Millimetres, general tolerance ±1 mm; 4 x Ø3.96 mm on 165.1 × 95.25 mm centres. Underside clearance 3 mm maximum component projection is shown below the board; allow the installation clearance required by the manufacturer. It is not a mounting-screw penetration rating. Mounting references Edge references 6.35 mm and 6.1 mm; the FG position is marked near the AC input. Forced-air installation At least 25 CFM, fan 15 cm from the illustrated board edge, with the shown airflow direction. Use the applicable complete mechanical drawing and installation instructions. The listed mating connector references, external fan and mounting hardware are not stated to be supplied accessories. Maintain the marked protective-ground connection and verify safety and EMC in the final equipment. Connectors and Mating References AC input CN1 JST B3P-VH or equivalent: pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing reference JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Main output CN2 and CN3 Two JST B8P-VH connectors or equivalents, using combined numbering 1–16: pins 1–4 V1; 5–11 COM; 12–13 V2; 14 V3; 15 absent; 16 V4. Use the signed channel voltages listed above. Signal connector CN4 JS-2008-03*2 or equivalent: 1 PG, 2 RS−, 3 GND, 4 RC+, 5 RS+, 6 RC−. Mating housing JS-2007-03*2; terminal JS-2007-T or equivalent. The main input/output connectors use the JST VHR housing family and JST SVH-21T-P1.1 contact reference. Select the complete mating housing for the required circuit count and wire size; loose mating parts and any external fan are not stated as included. Medical Isolation, Leakage and Safety Isolation level Primary–secondary: 2 MOPP. No additional MOPP levels are assigned here. Withstand voltage Input–output 4 kVAC; input–FG 2 kVAC; output–FG 1.5 kVAC. Insulation resistance Greater than 100 MΩ at 500 VDC, for input–output, input–FG and output–FG. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC. Touch current is measured from primary input to DC output. The safety table lists IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; and EAC TP TC004. The cover also carries UL60950-1. Verify the applicable component approval in the final equipment configuration. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. EMC and System Integration Conducted and radiated emissions: BS EN/EN55011 Class B. Harmonic current: BS EN/EN61000-3-2; voltage flicker: BS EN/EN61000-3-3; EAC TP TC020 is listed. The immunity table references EN61000-4-2 ESD: 8 kV air (Level 3) and 4 kV contact (Level 2); EN61000-4-3 RF field: 3 and 10 V/m; EN61000-4-4 EFT: 1 and 2 kV at 5 kHz; EN61000-4-5 surge: 2 kV line–line and 4 kV line–earth; EN61000-4-8 magnetic field: 3 and 10 A/m. EN61000-4-11 voltage dips/interruptions, EN61000-4-6 conducted RF and ENV50204 at 900 MHz are also referenced. Use the applicable manufacturer test report for precise conducted-RF and digital-phone test-level details. EMC tests used the unit on a 360 × 360 mm metal plate, 1 mm thick. This component is intended for installation in final equipment; reconfirm EMC compliance in the completed system. Weight and Reliability Catalogue single-unit reference 0.66 kg = 660 g per unit, from the PACKING entry. Carton reference 24 pieces / 16.8 kg / 1.17 CUFT; carton weight is not the per-unit product weight. MTBF, minimum 1679.6 K hours, Telcordia SR-332 (Bellcore); 213.8 K hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue edition MPQ-200-SPEC 2024-10-30; combined PDF pages 26–28. PACKING is a catalogue single-unit reference, not an independently weighed net or shipping mass. MTBF is a statistical estimate under the stated methods.

    $209.46

  • MPQ-200C

    MEAN WELL MPQ-200 series: Quad-Output Medical AC/DC Power Supply - MPQ-200C

    MEAN WELL MPQ-200C is a PCB-type four-output medical AC/DC power supply. It provides CH1 5 V, CH2 15 V, CH3 −5 V, CH4 −15 V. The total continuous output is limited to 140 W with natural convection or 200 W with at least 25 CFM forced airflow, together with every channel limit and applicable derating. Product Datasheet Download MEAN WELL MPQ-200 Datasheet (PDF) The MPQ-200 section is on PDF pages 26, 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Configuration Complete model MPQ-200C Output arrangement 4 outputs sharing the stated COM reference; polarity is shown separately for every channel. Construction PCB assembly for installation inside equipment. Nominal efficiency, typical 78%. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. Combined Load and Peak Limits Total continuous output 140 W maximum with natural convection; 200 W maximum with 25 CFM forced air. Individual channel limits also apply. Peak-current operation The peak-current column requires a 25 CFM fan. Maximum duty cycle is 33% within every 30 seconds, with average output power not exceeding rated power. Channel 1 voltage adjustment −5% to +10% of nominal CH1 voltage via the potentiometer; for 5 V CH1 this calculates to 4.75–5.5 V. The channel maximums are not permission to load every output to its maximum simultaneously. Keep the sum of the absolute channel output powers within the applicable combined power limit and meet all minimum-load requirements. Negative output voltage denotes polarity, not negative delivered power. The peak-current table does not print a separate combined peak-wattage limit or an independent pulse-duration value. The per-channel peak limits must not be added together as an allowable combined peak load. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. CH1 Electrical Ratings Output voltage 5 V. Rated current 15 A. Minimum load 3 A. Convection maximum current 12 A. Current with 25 CFM fan 15 A. Peak current with 25 CFM fan 18 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH2 Electrical Ratings Output voltage 15 V. Rated current 5 A. Minimum load 0.5 A. Convection maximum current 4 A. Current with 25 CFM fan 5 A. Peak current with 25 CFM fan 6 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 150 mVp-p. Voltage tolerance ±6.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH3 Electrical Ratings Output voltage −5 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH4 Electrical Ratings Output voltage −15 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. Input and Start-Up Input range 90–264 VAC, 47–63 Hz, or 127–370 VDC. Apply low-input derating. Input current, typical 3.5 A at 115 VAC; 1.6 A at 230 VAC, at 60 Hz and full output load. Cold-start inrush, typical Less than 25 A at 115 VAC; less than 40 A at 230 VAC, limited by internal thermistors. Set-up / rise time 1000 / 20 ms at 230 VAC; 3000 / 20 ms at 115 VAC, full load. Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load. Switching-frequency reference 100 kHz. Power factor, typical >0.95 at 230 VAC and >0.98 at 115 VAC, full load. Protection Short circuit / overload Hiccup protection at 120–160% rated load, with automatic recovery after the fault is removed. Overvoltage protection CH1 only, at 115–135% of its rated voltage. The output shuts down when activated; the page does not specify a recovery method. Overtemperature protection TSW1 senses the power-transistor heat sink. At 95°C the output shuts down; it recovers automatically after temperature falls. This is a heat-sink sensor threshold, not an ambient-temperature rating. Protection thresholds are fault limits, not additional operating ratings. Control, Status and Remote Sense Power Good / Power Fail TTL high indicates power good; low indicates failure. At 90% of rated output voltage, the +5 V TTL signal is asserted after 10–500 ms. It goes low at least 1 ms before output falls below 90% of rated voltage. Remote ON/OFF Across RC+ and RC−: 0–0.8 V turns the output on; 4–10 V turns it off. The catalogue prints the sink-current reference as <4–10 mA; confirm interface drive requirements from the manufacturer application instructions. Remote sense CN4 pin 5 RS+ and pin 2 RS−. Observe the correct output polarity and the manufacturer wiring instructions; these pages do not state a maximum compensation voltage. Power indication The mechanical drawing marks the LED power indicator. The status signal is available at CN4 pin 1 PG with pin 3 GND. Remote control is on pin 4 RC+ and pin 6 RC−; these functions must not be inferred from the connector position alone. No standby output is specified for these four-output models. Derating and Environment Working temperature −20 to +70°C, subject to the cooling curve. Thermal curve Horizontal mounting: natural convection allows 70% of the 200 W family rating through 40°C, falling to 30% at 60°C. With 25 CFM forced air, 100% is available through 50°C, falling to 40% at 70°C. The no-fan curve ends at 60°C. Input-voltage curve, 60 Hz 80% load at 90 VAC; 100% at 115 VAC through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage conditions −40 to +85°C; 10–90% RH. Temperature coefficient ±0.04%/°C on all outputs at full load, over 0–50°C. Vibration 10–500 Hz, 2 G; 10-minute cycles, six cycles / 60 minutes along each X, Y and Z axis. Altitude condition Above 2000 m, reduce allowable ambient temperature by 3.5°C per additional 1000 m for fanless operation, or 5°C per additional 1000 m for fan-cooled operation. No absolute operating-altitude maximum is specified on these MPQ pages. Apply temperature, input-voltage, cooling and channel loading restrictions together. Do not extrapolate beyond the plotted curve or treat a series name as the guaranteed output wattage. Installation and Mechanical Details Dimensions, L × W × H 177.8 × 107.2 × 35.5 mm. Drawing dimensions Millimetres, general tolerance ±1 mm; 4 x Ø3.96 mm on 165.1 × 95.25 mm centres. Underside clearance 3 mm maximum component projection is shown below the board; allow the installation clearance required by the manufacturer. It is not a mounting-screw penetration rating. Mounting references Edge references 6.35 mm and 6.1 mm; the FG position is marked near the AC input. Forced-air installation At least 25 CFM, fan 15 cm from the illustrated board edge, with the shown airflow direction. Use the applicable complete mechanical drawing and installation instructions. The listed mating connector references, external fan and mounting hardware are not stated to be supplied accessories. Maintain the marked protective-ground connection and verify safety and EMC in the final equipment. Connectors and Mating References AC input CN1 JST B3P-VH or equivalent: pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing reference JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Main output CN2 and CN3 Two JST B8P-VH connectors or equivalents, using combined numbering 1–16: pins 1–4 V1; 5–11 COM; 12–13 V2; 14 V3; 15 absent; 16 V4. Use the signed channel voltages listed above. Signal connector CN4 JS-2008-03*2 or equivalent: 1 PG, 2 RS−, 3 GND, 4 RC+, 5 RS+, 6 RC−. Mating housing JS-2007-03*2; terminal JS-2007-T or equivalent. The main input/output connectors use the JST VHR housing family and JST SVH-21T-P1.1 contact reference. Select the complete mating housing for the required circuit count and wire size; loose mating parts and any external fan are not stated as included. Medical Isolation, Leakage and Safety Isolation level Primary–secondary: 2 MOPP. No additional MOPP levels are assigned here. Withstand voltage Input–output 4 kVAC; input–FG 2 kVAC; output–FG 1.5 kVAC. Insulation resistance Greater than 100 MΩ at 500 VDC, for input–output, input–FG and output–FG. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC. Touch current is measured from primary input to DC output. The safety table lists IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; and EAC TP TC004. The cover also carries UL60950-1. Verify the applicable component approval in the final equipment configuration. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. EMC and System Integration Conducted and radiated emissions: BS EN/EN55011 Class B. Harmonic current: BS EN/EN61000-3-2; voltage flicker: BS EN/EN61000-3-3; EAC TP TC020 is listed. The immunity table references EN61000-4-2 ESD: 8 kV air (Level 3) and 4 kV contact (Level 2); EN61000-4-3 RF field: 3 and 10 V/m; EN61000-4-4 EFT: 1 and 2 kV at 5 kHz; EN61000-4-5 surge: 2 kV line–line and 4 kV line–earth; EN61000-4-8 magnetic field: 3 and 10 A/m. EN61000-4-11 voltage dips/interruptions, EN61000-4-6 conducted RF and ENV50204 at 900 MHz are also referenced. Use the applicable manufacturer test report for precise conducted-RF and digital-phone test-level details. EMC tests used the unit on a 360 × 360 mm metal plate, 1 mm thick. This component is intended for installation in final equipment; reconfirm EMC compliance in the completed system. Weight and Reliability Catalogue single-unit reference 0.66 kg = 660 g per unit, from the PACKING entry. Carton reference 24 pieces / 16.8 kg / 1.17 CUFT; carton weight is not the per-unit product weight. MTBF, minimum 1679.6 K hours, Telcordia SR-332 (Bellcore); 213.8 K hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue edition MPQ-200-SPEC 2024-10-30; combined PDF pages 26–28. PACKING is a catalogue single-unit reference, not an independently weighed net or shipping mass. MTBF is a statistical estimate under the stated methods.

    $209.46

  • MPQ-200C

    MEAN WELL MPQ-200 series: Quad-Output Medical AC/DC Power Supply - MPQ-200C

    MEAN WELL MPQ-200C is a PCB-type four-output medical AC/DC power supply. It provides CH1 5 V, CH2 15 V, CH3 −5 V, CH4 −15 V. The total continuous output is limited to 140 W with natural convection or 200 W with at least 25 CFM forced airflow, together with every channel limit and applicable derating. Product Datasheet Download MEAN WELL MPQ-200 Datasheet (PDF) The MPQ-200 section is on PDF pages 26, 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Configuration Complete model MPQ-200C Output arrangement 4 outputs sharing the stated COM reference; polarity is shown separately for every channel. Construction PCB assembly for installation inside equipment. Nominal efficiency, typical 78%. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. Combined Load and Peak Limits Total continuous output 140 W maximum with natural convection; 200 W maximum with 25 CFM forced air. Individual channel limits also apply. Peak-current operation The peak-current column requires a 25 CFM fan. Maximum duty cycle is 33% within every 30 seconds, with average output power not exceeding rated power. Channel 1 voltage adjustment −5% to +10% of nominal CH1 voltage via the potentiometer; for 5 V CH1 this calculates to 4.75–5.5 V. The channel maximums are not permission to load every output to its maximum simultaneously. Keep the sum of the absolute channel output powers within the applicable combined power limit and meet all minimum-load requirements. Negative output voltage denotes polarity, not negative delivered power. The peak-current table does not print a separate combined peak-wattage limit or an independent pulse-duration value. The per-channel peak limits must not be added together as an allowable combined peak load. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. CH1 Electrical Ratings Output voltage 5 V. Rated current 15 A. Minimum load 3 A. Convection maximum current 12 A. Current with 25 CFM fan 15 A. Peak current with 25 CFM fan 18 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH2 Electrical Ratings Output voltage 15 V. Rated current 5 A. Minimum load 0.5 A. Convection maximum current 4 A. Current with 25 CFM fan 5 A. Peak current with 25 CFM fan 6 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 150 mVp-p. Voltage tolerance ±6.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH3 Electrical Ratings Output voltage −5 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH4 Electrical Ratings Output voltage −15 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. Input and Start-Up Input range 90–264 VAC, 47–63 Hz, or 127–370 VDC. Apply low-input derating. Input current, typical 3.5 A at 115 VAC; 1.6 A at 230 VAC, at 60 Hz and full output load. Cold-start inrush, typical Less than 25 A at 115 VAC; less than 40 A at 230 VAC, limited by internal thermistors. Set-up / rise time 1000 / 20 ms at 230 VAC; 3000 / 20 ms at 115 VAC, full load. Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load. Switching-frequency reference 100 kHz. Power factor, typical >0.95 at 230 VAC and >0.98 at 115 VAC, full load. Protection Short circuit / overload Hiccup protection at 120–160% rated load, with automatic recovery after the fault is removed. Overvoltage protection CH1 only, at 115–135% of its rated voltage. The output shuts down when activated; the page does not specify a recovery method. Overtemperature protection TSW1 senses the power-transistor heat sink. At 95°C the output shuts down; it recovers automatically after temperature falls. This is a heat-sink sensor threshold, not an ambient-temperature rating. Protection thresholds are fault limits, not additional operating ratings. Control, Status and Remote Sense Power Good / Power Fail TTL high indicates power good; low indicates failure. At 90% of rated output voltage, the +5 V TTL signal is asserted after 10–500 ms. It goes low at least 1 ms before output falls below 90% of rated voltage. Remote ON/OFF Across RC+ and RC−: 0–0.8 V turns the output on; 4–10 V turns it off. The catalogue prints the sink-current reference as <4–10 mA; confirm interface drive requirements from the manufacturer application instructions. Remote sense CN4 pin 5 RS+ and pin 2 RS−. Observe the correct output polarity and the manufacturer wiring instructions; these pages do not state a maximum compensation voltage. Power indication The mechanical drawing marks the LED power indicator. The status signal is available at CN4 pin 1 PG with pin 3 GND. Remote control is on pin 4 RC+ and pin 6 RC−; these functions must not be inferred from the connector position alone. No standby output is specified for these four-output models. Derating and Environment Working temperature −20 to +70°C, subject to the cooling curve. Thermal curve Horizontal mounting: natural convection allows 70% of the 200 W family rating through 40°C, falling to 30% at 60°C. With 25 CFM forced air, 100% is available through 50°C, falling to 40% at 70°C. The no-fan curve ends at 60°C. Input-voltage curve, 60 Hz 80% load at 90 VAC; 100% at 115 VAC through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage conditions −40 to +85°C; 10–90% RH. Temperature coefficient ±0.04%/°C on all outputs at full load, over 0–50°C. Vibration 10–500 Hz, 2 G; 10-minute cycles, six cycles / 60 minutes along each X, Y and Z axis. Altitude condition Above 2000 m, reduce allowable ambient temperature by 3.5°C per additional 1000 m for fanless operation, or 5°C per additional 1000 m for fan-cooled operation. No absolute operating-altitude maximum is specified on these MPQ pages. Apply temperature, input-voltage, cooling and channel loading restrictions together. Do not extrapolate beyond the plotted curve or treat a series name as the guaranteed output wattage. Installation and Mechanical Details Dimensions, L × W × H 177.8 × 107.2 × 35.5 mm. Drawing dimensions Millimetres, general tolerance ±1 mm; 4 x Ø3.96 mm on 165.1 × 95.25 mm centres. Underside clearance 3 mm maximum component projection is shown below the board; allow the installation clearance required by the manufacturer. It is not a mounting-screw penetration rating. Mounting references Edge references 6.35 mm and 6.1 mm; the FG position is marked near the AC input. Forced-air installation At least 25 CFM, fan 15 cm from the illustrated board edge, with the shown airflow direction. Use the applicable complete mechanical drawing and installation instructions. The listed mating connector references, external fan and mounting hardware are not stated to be supplied accessories. Maintain the marked protective-ground connection and verify safety and EMC in the final equipment. Connectors and Mating References AC input CN1 JST B3P-VH or equivalent: pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing reference JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Main output CN2 and CN3 Two JST B8P-VH connectors or equivalents, using combined numbering 1–16: pins 1–4 V1; 5–11 COM; 12–13 V2; 14 V3; 15 absent; 16 V4. Use the signed channel voltages listed above. Signal connector CN4 JS-2008-03*2 or equivalent: 1 PG, 2 RS−, 3 GND, 4 RC+, 5 RS+, 6 RC−. Mating housing JS-2007-03*2; terminal JS-2007-T or equivalent. The main input/output connectors use the JST VHR housing family and JST SVH-21T-P1.1 contact reference. Select the complete mating housing for the required circuit count and wire size; loose mating parts and any external fan are not stated as included. Medical Isolation, Leakage and Safety Isolation level Primary–secondary: 2 MOPP. No additional MOPP levels are assigned here. Withstand voltage Input–output 4 kVAC; input–FG 2 kVAC; output–FG 1.5 kVAC. Insulation resistance Greater than 100 MΩ at 500 VDC, for input–output, input–FG and output–FG. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC. Touch current is measured from primary input to DC output. The safety table lists IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; and EAC TP TC004. The cover also carries UL60950-1. Verify the applicable component approval in the final equipment configuration. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. EMC and System Integration Conducted and radiated emissions: BS EN/EN55011 Class B. Harmonic current: BS EN/EN61000-3-2; voltage flicker: BS EN/EN61000-3-3; EAC TP TC020 is listed. The immunity table references EN61000-4-2 ESD: 8 kV air (Level 3) and 4 kV contact (Level 2); EN61000-4-3 RF field: 3 and 10 V/m; EN61000-4-4 EFT: 1 and 2 kV at 5 kHz; EN61000-4-5 surge: 2 kV line–line and 4 kV line–earth; EN61000-4-8 magnetic field: 3 and 10 A/m. EN61000-4-11 voltage dips/interruptions, EN61000-4-6 conducted RF and ENV50204 at 900 MHz are also referenced. Use the applicable manufacturer test report for precise conducted-RF and digital-phone test-level details. EMC tests used the unit on a 360 × 360 mm metal plate, 1 mm thick. This component is intended for installation in final equipment; reconfirm EMC compliance in the completed system. Weight and Reliability Catalogue single-unit reference 0.66 kg = 660 g per unit, from the PACKING entry. Carton reference 24 pieces / 16.8 kg / 1.17 CUFT; carton weight is not the per-unit product weight. MTBF, minimum 1679.6 K hours, Telcordia SR-332 (Bellcore); 213.8 K hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue edition MPQ-200-SPEC 2024-10-30; combined PDF pages 26–28. PACKING is a catalogue single-unit reference, not an independently weighed net or shipping mass. MTBF is a statistical estimate under the stated methods.

    $209.46

  • MPQ-200B

    MEAN WELL MPQ-200 series: Quad-Output Medical AC/DC Power Supply - MPQ-200B

    MEAN WELL MPQ-200B is a PCB-type four-output medical AC/DC power supply. It provides CH1 5 V, CH2 12 V, CH3 −5 V, CH4 −12 V. The total continuous output is limited to 140 W with natural convection or 200 W with at least 25 CFM forced airflow, together with every channel limit and applicable derating. Product Datasheet Download MEAN WELL MPQ-200 Datasheet (PDF) The MPQ-200 section is on PDF pages 26, 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Configuration Complete model MPQ-200B Output arrangement 4 outputs sharing the stated COM reference; polarity is shown separately for every channel. Construction PCB assembly for installation inside equipment. Nominal efficiency, typical 78%. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. Combined Load and Peak Limits Total continuous output 140 W maximum with natural convection; 200 W maximum with 25 CFM forced air. Individual channel limits also apply. Peak-current operation The peak-current column requires a 25 CFM fan. Maximum duty cycle is 33% within every 30 seconds, with average output power not exceeding rated power. Channel 1 voltage adjustment −5% to +10% of nominal CH1 voltage via the potentiometer; for 5 V CH1 this calculates to 4.75–5.5 V. The channel maximums are not permission to load every output to its maximum simultaneously. Keep the sum of the absolute channel output powers within the applicable combined power limit and meet all minimum-load requirements. Negative output voltage denotes polarity, not negative delivered power. The peak-current table does not print a separate combined peak-wattage limit or an independent pulse-duration value. The per-channel peak limits must not be added together as an allowable combined peak load. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. CH1 Electrical Ratings Output voltage 5 V. Rated current 15 A. Minimum load 3 A. Convection maximum current 12 A. Current with 25 CFM fan 15 A. Peak current with 25 CFM fan 18 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH2 Electrical Ratings Output voltage 12 V. Rated current 7 A. Minimum load 0.7 A. Convection maximum current 5.3 A. Current with 25 CFM fan 7 A. Peak current with 25 CFM fan 8.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±8.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH3 Electrical Ratings Output voltage −5 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH4 Electrical Ratings Output voltage −12 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. Input and Start-Up Input range 90–264 VAC, 47–63 Hz, or 127–370 VDC. Apply low-input derating. Input current, typical 3.5 A at 115 VAC; 1.6 A at 230 VAC, at 60 Hz and full output load. Cold-start inrush, typical Less than 25 A at 115 VAC; less than 40 A at 230 VAC, limited by internal thermistors. Set-up / rise time 1000 / 20 ms at 230 VAC; 3000 / 20 ms at 115 VAC, full load. Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load. Switching-frequency reference 100 kHz. Power factor, typical >0.95 at 230 VAC and >0.98 at 115 VAC, full load. Protection Short circuit / overload Hiccup protection at 120–160% rated load, with automatic recovery after the fault is removed. Overvoltage protection CH1 only, at 115–135% of its rated voltage. The output shuts down when activated; the page does not specify a recovery method. Overtemperature protection TSW1 senses the power-transistor heat sink. At 95°C the output shuts down; it recovers automatically after temperature falls. This is a heat-sink sensor threshold, not an ambient-temperature rating. Protection thresholds are fault limits, not additional operating ratings. Control, Status and Remote Sense Power Good / Power Fail TTL high indicates power good; low indicates failure. At 90% of rated output voltage, the +5 V TTL signal is asserted after 10–500 ms. It goes low at least 1 ms before output falls below 90% of rated voltage. Remote ON/OFF Across RC+ and RC−: 0–0.8 V turns the output on; 4–10 V turns it off. The catalogue prints the sink-current reference as <4–10 mA; confirm interface drive requirements from the manufacturer application instructions. Remote sense CN4 pin 5 RS+ and pin 2 RS−. Observe the correct output polarity and the manufacturer wiring instructions; these pages do not state a maximum compensation voltage. Power indication The mechanical drawing marks the LED power indicator. The status signal is available at CN4 pin 1 PG with pin 3 GND. Remote control is on pin 4 RC+ and pin 6 RC−; these functions must not be inferred from the connector position alone. No standby output is specified for these four-output models. Derating and Environment Working temperature −20 to +70°C, subject to the cooling curve. Thermal curve Horizontal mounting: natural convection allows 70% of the 200 W family rating through 40°C, falling to 30% at 60°C. With 25 CFM forced air, 100% is available through 50°C, falling to 40% at 70°C. The no-fan curve ends at 60°C. Input-voltage curve, 60 Hz 80% load at 90 VAC; 100% at 115 VAC through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage conditions −40 to +85°C; 10–90% RH. Temperature coefficient ±0.04%/°C on all outputs at full load, over 0–50°C. Vibration 10–500 Hz, 2 G; 10-minute cycles, six cycles / 60 minutes along each X, Y and Z axis. Altitude condition Above 2000 m, reduce allowable ambient temperature by 3.5°C per additional 1000 m for fanless operation, or 5°C per additional 1000 m for fan-cooled operation. No absolute operating-altitude maximum is specified on these MPQ pages. Apply temperature, input-voltage, cooling and channel loading restrictions together. Do not extrapolate beyond the plotted curve or treat a series name as the guaranteed output wattage. Installation and Mechanical Details Dimensions, L × W × H 177.8 × 107.2 × 35.5 mm. Drawing dimensions Millimetres, general tolerance ±1 mm; 4 x Ø3.96 mm on 165.1 × 95.25 mm centres. Underside clearance 3 mm maximum component projection is shown below the board; allow the installation clearance required by the manufacturer. It is not a mounting-screw penetration rating. Mounting references Edge references 6.35 mm and 6.1 mm; the FG position is marked near the AC input. Forced-air installation At least 25 CFM, fan 15 cm from the illustrated board edge, with the shown airflow direction. Use the applicable complete mechanical drawing and installation instructions. The listed mating connector references, external fan and mounting hardware are not stated to be supplied accessories. Maintain the marked protective-ground connection and verify safety and EMC in the final equipment. Connectors and Mating References AC input CN1 JST B3P-VH or equivalent: pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing reference JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Main output CN2 and CN3 Two JST B8P-VH connectors or equivalents, using combined numbering 1–16: pins 1–4 V1; 5–11 COM; 12–13 V2; 14 V3; 15 absent; 16 V4. Use the signed channel voltages listed above. Signal connector CN4 JS-2008-03*2 or equivalent: 1 PG, 2 RS−, 3 GND, 4 RC+, 5 RS+, 6 RC−. Mating housing JS-2007-03*2; terminal JS-2007-T or equivalent. The main input/output connectors use the JST VHR housing family and JST SVH-21T-P1.1 contact reference. Select the complete mating housing for the required circuit count and wire size; loose mating parts and any external fan are not stated as included. Medical Isolation, Leakage and Safety Isolation level Primary–secondary: 2 MOPP. No additional MOPP levels are assigned here. Withstand voltage Input–output 4 kVAC; input–FG 2 kVAC; output–FG 1.5 kVAC. Insulation resistance Greater than 100 MΩ at 500 VDC, for input–output, input–FG and output–FG. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC. Touch current is measured from primary input to DC output. The safety table lists IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; and EAC TP TC004. The cover also carries UL60950-1. Verify the applicable component approval in the final equipment configuration. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. EMC and System Integration Conducted and radiated emissions: BS EN/EN55011 Class B. Harmonic current: BS EN/EN61000-3-2; voltage flicker: BS EN/EN61000-3-3; EAC TP TC020 is listed. The immunity table references EN61000-4-2 ESD: 8 kV air (Level 3) and 4 kV contact (Level 2); EN61000-4-3 RF field: 3 and 10 V/m; EN61000-4-4 EFT: 1 and 2 kV at 5 kHz; EN61000-4-5 surge: 2 kV line–line and 4 kV line–earth; EN61000-4-8 magnetic field: 3 and 10 A/m. EN61000-4-11 voltage dips/interruptions, EN61000-4-6 conducted RF and ENV50204 at 900 MHz are also referenced. Use the applicable manufacturer test report for precise conducted-RF and digital-phone test-level details. EMC tests used the unit on a 360 × 360 mm metal plate, 1 mm thick. This component is intended for installation in final equipment; reconfirm EMC compliance in the completed system. Weight and Reliability Catalogue single-unit reference 0.66 kg = 660 g per unit, from the PACKING entry. Carton reference 24 pieces / 16.8 kg / 1.17 CUFT; carton weight is not the per-unit product weight. MTBF, minimum 1679.6 K hours, Telcordia SR-332 (Bellcore); 213.8 K hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue edition MPQ-200-SPEC 2024-10-30; combined PDF pages 26–28. PACKING is a catalogue single-unit reference, not an independently weighed net or shipping mass. MTBF is a statistical estimate under the stated methods.

    $209.46

  • MPQ-200B

    MEAN WELL MPQ-200 series: Quad-Output Medical AC/DC Power Supply - MPQ-200B

    MEAN WELL MPQ-200B is a PCB-type four-output medical AC/DC power supply. It provides CH1 5 V, CH2 12 V, CH3 −5 V, CH4 −12 V. The total continuous output is limited to 140 W with natural convection or 200 W with at least 25 CFM forced airflow, together with every channel limit and applicable derating. Product Datasheet Download MEAN WELL MPQ-200 Datasheet (PDF) The MPQ-200 section is on PDF pages 26, 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Configuration Complete model MPQ-200B Output arrangement 4 outputs sharing the stated COM reference; polarity is shown separately for every channel. Construction PCB assembly for installation inside equipment. Nominal efficiency, typical 78%. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. Combined Load and Peak Limits Total continuous output 140 W maximum with natural convection; 200 W maximum with 25 CFM forced air. Individual channel limits also apply. Peak-current operation The peak-current column requires a 25 CFM fan. Maximum duty cycle is 33% within every 30 seconds, with average output power not exceeding rated power. Channel 1 voltage adjustment −5% to +10% of nominal CH1 voltage via the potentiometer; for 5 V CH1 this calculates to 4.75–5.5 V. The channel maximums are not permission to load every output to its maximum simultaneously. Keep the sum of the absolute channel output powers within the applicable combined power limit and meet all minimum-load requirements. Negative output voltage denotes polarity, not negative delivered power. The peak-current table does not print a separate combined peak-wattage limit or an independent pulse-duration value. The per-channel peak limits must not be added together as an allowable combined peak load. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. CH1 Electrical Ratings Output voltage 5 V. Rated current 15 A. Minimum load 3 A. Convection maximum current 12 A. Current with 25 CFM fan 15 A. Peak current with 25 CFM fan 18 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH2 Electrical Ratings Output voltage 12 V. Rated current 7 A. Minimum load 0.7 A. Convection maximum current 5.3 A. Current with 25 CFM fan 7 A. Peak current with 25 CFM fan 8.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±8.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH3 Electrical Ratings Output voltage −5 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH4 Electrical Ratings Output voltage −12 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. Input and Start-Up Input range 90–264 VAC, 47–63 Hz, or 127–370 VDC. Apply low-input derating. Input current, typical 3.5 A at 115 VAC; 1.6 A at 230 VAC, at 60 Hz and full output load. Cold-start inrush, typical Less than 25 A at 115 VAC; less than 40 A at 230 VAC, limited by internal thermistors. Set-up / rise time 1000 / 20 ms at 230 VAC; 3000 / 20 ms at 115 VAC, full load. Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load. Switching-frequency reference 100 kHz. Power factor, typical >0.95 at 230 VAC and >0.98 at 115 VAC, full load. Protection Short circuit / overload Hiccup protection at 120–160% rated load, with automatic recovery after the fault is removed. Overvoltage protection CH1 only, at 115–135% of its rated voltage. The output shuts down when activated; the page does not specify a recovery method. Overtemperature protection TSW1 senses the power-transistor heat sink. At 95°C the output shuts down; it recovers automatically after temperature falls. This is a heat-sink sensor threshold, not an ambient-temperature rating. Protection thresholds are fault limits, not additional operating ratings. Control, Status and Remote Sense Power Good / Power Fail TTL high indicates power good; low indicates failure. At 90% of rated output voltage, the +5 V TTL signal is asserted after 10–500 ms. It goes low at least 1 ms before output falls below 90% of rated voltage. Remote ON/OFF Across RC+ and RC−: 0–0.8 V turns the output on; 4–10 V turns it off. The catalogue prints the sink-current reference as <4–10 mA; confirm interface drive requirements from the manufacturer application instructions. Remote sense CN4 pin 5 RS+ and pin 2 RS−. Observe the correct output polarity and the manufacturer wiring instructions; these pages do not state a maximum compensation voltage. Power indication The mechanical drawing marks the LED power indicator. The status signal is available at CN4 pin 1 PG with pin 3 GND. Remote control is on pin 4 RC+ and pin 6 RC−; these functions must not be inferred from the connector position alone. No standby output is specified for these four-output models. Derating and Environment Working temperature −20 to +70°C, subject to the cooling curve. Thermal curve Horizontal mounting: natural convection allows 70% of the 200 W family rating through 40°C, falling to 30% at 60°C. With 25 CFM forced air, 100% is available through 50°C, falling to 40% at 70°C. The no-fan curve ends at 60°C. Input-voltage curve, 60 Hz 80% load at 90 VAC; 100% at 115 VAC through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage conditions −40 to +85°C; 10–90% RH. Temperature coefficient ±0.04%/°C on all outputs at full load, over 0–50°C. Vibration 10–500 Hz, 2 G; 10-minute cycles, six cycles / 60 minutes along each X, Y and Z axis. Altitude condition Above 2000 m, reduce allowable ambient temperature by 3.5°C per additional 1000 m for fanless operation, or 5°C per additional 1000 m for fan-cooled operation. No absolute operating-altitude maximum is specified on these MPQ pages. Apply temperature, input-voltage, cooling and channel loading restrictions together. Do not extrapolate beyond the plotted curve or treat a series name as the guaranteed output wattage. Installation and Mechanical Details Dimensions, L × W × H 177.8 × 107.2 × 35.5 mm. Drawing dimensions Millimetres, general tolerance ±1 mm; 4 x Ø3.96 mm on 165.1 × 95.25 mm centres. Underside clearance 3 mm maximum component projection is shown below the board; allow the installation clearance required by the manufacturer. It is not a mounting-screw penetration rating. Mounting references Edge references 6.35 mm and 6.1 mm; the FG position is marked near the AC input. Forced-air installation At least 25 CFM, fan 15 cm from the illustrated board edge, with the shown airflow direction. Use the applicable complete mechanical drawing and installation instructions. The listed mating connector references, external fan and mounting hardware are not stated to be supplied accessories. Maintain the marked protective-ground connection and verify safety and EMC in the final equipment. Connectors and Mating References AC input CN1 JST B3P-VH or equivalent: pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing reference JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Main output CN2 and CN3 Two JST B8P-VH connectors or equivalents, using combined numbering 1–16: pins 1–4 V1; 5–11 COM; 12–13 V2; 14 V3; 15 absent; 16 V4. Use the signed channel voltages listed above. Signal connector CN4 JS-2008-03*2 or equivalent: 1 PG, 2 RS−, 3 GND, 4 RC+, 5 RS+, 6 RC−. Mating housing JS-2007-03*2; terminal JS-2007-T or equivalent. The main input/output connectors use the JST VHR housing family and JST SVH-21T-P1.1 contact reference. Select the complete mating housing for the required circuit count and wire size; loose mating parts and any external fan are not stated as included. Medical Isolation, Leakage and Safety Isolation level Primary–secondary: 2 MOPP. No additional MOPP levels are assigned here. Withstand voltage Input–output 4 kVAC; input–FG 2 kVAC; output–FG 1.5 kVAC. Insulation resistance Greater than 100 MΩ at 500 VDC, for input–output, input–FG and output–FG. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC. Touch current is measured from primary input to DC output. The safety table lists IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; and EAC TP TC004. The cover also carries UL60950-1. Verify the applicable component approval in the final equipment configuration. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. EMC and System Integration Conducted and radiated emissions: BS EN/EN55011 Class B. Harmonic current: BS EN/EN61000-3-2; voltage flicker: BS EN/EN61000-3-3; EAC TP TC020 is listed. The immunity table references EN61000-4-2 ESD: 8 kV air (Level 3) and 4 kV contact (Level 2); EN61000-4-3 RF field: 3 and 10 V/m; EN61000-4-4 EFT: 1 and 2 kV at 5 kHz; EN61000-4-5 surge: 2 kV line–line and 4 kV line–earth; EN61000-4-8 magnetic field: 3 and 10 A/m. EN61000-4-11 voltage dips/interruptions, EN61000-4-6 conducted RF and ENV50204 at 900 MHz are also referenced. Use the applicable manufacturer test report for precise conducted-RF and digital-phone test-level details. EMC tests used the unit on a 360 × 360 mm metal plate, 1 mm thick. This component is intended for installation in final equipment; reconfirm EMC compliance in the completed system. Weight and Reliability Catalogue single-unit reference 0.66 kg = 660 g per unit, from the PACKING entry. Carton reference 24 pieces / 16.8 kg / 1.17 CUFT; carton weight is not the per-unit product weight. MTBF, minimum 1679.6 K hours, Telcordia SR-332 (Bellcore); 213.8 K hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue edition MPQ-200-SPEC 2024-10-30; combined PDF pages 26–28. PACKING is a catalogue single-unit reference, not an independently weighed net or shipping mass. MTBF is a statistical estimate under the stated methods.

    $209.46

  • MPQ-200B

    MEAN WELL MPQ-200 series: Quad-Output Medical AC/DC Power Supply - MPQ-200B

    MEAN WELL MPQ-200B is a PCB-type four-output medical AC/DC power supply. It provides CH1 5 V, CH2 12 V, CH3 −5 V, CH4 −12 V. The total continuous output is limited to 140 W with natural convection or 200 W with at least 25 CFM forced airflow, together with every channel limit and applicable derating. Product Datasheet Download MEAN WELL MPQ-200 Datasheet (PDF) The MPQ-200 section is on PDF pages 26, 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Configuration Complete model MPQ-200B Output arrangement 4 outputs sharing the stated COM reference; polarity is shown separately for every channel. Construction PCB assembly for installation inside equipment. Nominal efficiency, typical 78%. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. Combined Load and Peak Limits Total continuous output 140 W maximum with natural convection; 200 W maximum with 25 CFM forced air. Individual channel limits also apply. Peak-current operation The peak-current column requires a 25 CFM fan. Maximum duty cycle is 33% within every 30 seconds, with average output power not exceeding rated power. Channel 1 voltage adjustment −5% to +10% of nominal CH1 voltage via the potentiometer; for 5 V CH1 this calculates to 4.75–5.5 V. The channel maximums are not permission to load every output to its maximum simultaneously. Keep the sum of the absolute channel output powers within the applicable combined power limit and meet all minimum-load requirements. Negative output voltage denotes polarity, not negative delivered power. The peak-current table does not print a separate combined peak-wattage limit or an independent pulse-duration value. The per-channel peak limits must not be added together as an allowable combined peak load. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. CH1 Electrical Ratings Output voltage 5 V. Rated current 15 A. Minimum load 3 A. Convection maximum current 12 A. Current with 25 CFM fan 15 A. Peak current with 25 CFM fan 18 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH2 Electrical Ratings Output voltage 12 V. Rated current 7 A. Minimum load 0.7 A. Convection maximum current 5.3 A. Current with 25 CFM fan 7 A. Peak current with 25 CFM fan 8.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±8.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH3 Electrical Ratings Output voltage −5 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH4 Electrical Ratings Output voltage −12 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. Input and Start-Up Input range 90–264 VAC, 47–63 Hz, or 127–370 VDC. Apply low-input derating. Input current, typical 3.5 A at 115 VAC; 1.6 A at 230 VAC, at 60 Hz and full output load. Cold-start inrush, typical Less than 25 A at 115 VAC; less than 40 A at 230 VAC, limited by internal thermistors. Set-up / rise time 1000 / 20 ms at 230 VAC; 3000 / 20 ms at 115 VAC, full load. Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load. Switching-frequency reference 100 kHz. Power factor, typical >0.95 at 230 VAC and >0.98 at 115 VAC, full load. Protection Short circuit / overload Hiccup protection at 120–160% rated load, with automatic recovery after the fault is removed. Overvoltage protection CH1 only, at 115–135% of its rated voltage. The output shuts down when activated; the page does not specify a recovery method. Overtemperature protection TSW1 senses the power-transistor heat sink. At 95°C the output shuts down; it recovers automatically after temperature falls. This is a heat-sink sensor threshold, not an ambient-temperature rating. Protection thresholds are fault limits, not additional operating ratings. Control, Status and Remote Sense Power Good / Power Fail TTL high indicates power good; low indicates failure. At 90% of rated output voltage, the +5 V TTL signal is asserted after 10–500 ms. It goes low at least 1 ms before output falls below 90% of rated voltage. Remote ON/OFF Across RC+ and RC−: 0–0.8 V turns the output on; 4–10 V turns it off. The catalogue prints the sink-current reference as <4–10 mA; confirm interface drive requirements from the manufacturer application instructions. Remote sense CN4 pin 5 RS+ and pin 2 RS−. Observe the correct output polarity and the manufacturer wiring instructions; these pages do not state a maximum compensation voltage. Power indication The mechanical drawing marks the LED power indicator. The status signal is available at CN4 pin 1 PG with pin 3 GND. Remote control is on pin 4 RC+ and pin 6 RC−; these functions must not be inferred from the connector position alone. No standby output is specified for these four-output models. Derating and Environment Working temperature −20 to +70°C, subject to the cooling curve. Thermal curve Horizontal mounting: natural convection allows 70% of the 200 W family rating through 40°C, falling to 30% at 60°C. With 25 CFM forced air, 100% is available through 50°C, falling to 40% at 70°C. The no-fan curve ends at 60°C. Input-voltage curve, 60 Hz 80% load at 90 VAC; 100% at 115 VAC through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage conditions −40 to +85°C; 10–90% RH. Temperature coefficient ±0.04%/°C on all outputs at full load, over 0–50°C. Vibration 10–500 Hz, 2 G; 10-minute cycles, six cycles / 60 minutes along each X, Y and Z axis. Altitude condition Above 2000 m, reduce allowable ambient temperature by 3.5°C per additional 1000 m for fanless operation, or 5°C per additional 1000 m for fan-cooled operation. No absolute operating-altitude maximum is specified on these MPQ pages. Apply temperature, input-voltage, cooling and channel loading restrictions together. Do not extrapolate beyond the plotted curve or treat a series name as the guaranteed output wattage. Installation and Mechanical Details Dimensions, L × W × H 177.8 × 107.2 × 35.5 mm. Drawing dimensions Millimetres, general tolerance ±1 mm; 4 x Ø3.96 mm on 165.1 × 95.25 mm centres. Underside clearance 3 mm maximum component projection is shown below the board; allow the installation clearance required by the manufacturer. It is not a mounting-screw penetration rating. Mounting references Edge references 6.35 mm and 6.1 mm; the FG position is marked near the AC input. Forced-air installation At least 25 CFM, fan 15 cm from the illustrated board edge, with the shown airflow direction. Use the applicable complete mechanical drawing and installation instructions. The listed mating connector references, external fan and mounting hardware are not stated to be supplied accessories. Maintain the marked protective-ground connection and verify safety and EMC in the final equipment. Connectors and Mating References AC input CN1 JST B3P-VH or equivalent: pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing reference JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Main output CN2 and CN3 Two JST B8P-VH connectors or equivalents, using combined numbering 1–16: pins 1–4 V1; 5–11 COM; 12–13 V2; 14 V3; 15 absent; 16 V4. Use the signed channel voltages listed above. Signal connector CN4 JS-2008-03*2 or equivalent: 1 PG, 2 RS−, 3 GND, 4 RC+, 5 RS+, 6 RC−. Mating housing JS-2007-03*2; terminal JS-2007-T or equivalent. The main input/output connectors use the JST VHR housing family and JST SVH-21T-P1.1 contact reference. Select the complete mating housing for the required circuit count and wire size; loose mating parts and any external fan are not stated as included. Medical Isolation, Leakage and Safety Isolation level Primary–secondary: 2 MOPP. No additional MOPP levels are assigned here. Withstand voltage Input–output 4 kVAC; input–FG 2 kVAC; output–FG 1.5 kVAC. Insulation resistance Greater than 100 MΩ at 500 VDC, for input–output, input–FG and output–FG. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC. Touch current is measured from primary input to DC output. The safety table lists IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; and EAC TP TC004. The cover also carries UL60950-1. Verify the applicable component approval in the final equipment configuration. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. EMC and System Integration Conducted and radiated emissions: BS EN/EN55011 Class B. Harmonic current: BS EN/EN61000-3-2; voltage flicker: BS EN/EN61000-3-3; EAC TP TC020 is listed. The immunity table references EN61000-4-2 ESD: 8 kV air (Level 3) and 4 kV contact (Level 2); EN61000-4-3 RF field: 3 and 10 V/m; EN61000-4-4 EFT: 1 and 2 kV at 5 kHz; EN61000-4-5 surge: 2 kV line–line and 4 kV line–earth; EN61000-4-8 magnetic field: 3 and 10 A/m. EN61000-4-11 voltage dips/interruptions, EN61000-4-6 conducted RF and ENV50204 at 900 MHz are also referenced. Use the applicable manufacturer test report for precise conducted-RF and digital-phone test-level details. EMC tests used the unit on a 360 × 360 mm metal plate, 1 mm thick. This component is intended for installation in final equipment; reconfirm EMC compliance in the completed system. Weight and Reliability Catalogue single-unit reference 0.66 kg = 660 g per unit, from the PACKING entry. Carton reference 24 pieces / 16.8 kg / 1.17 CUFT; carton weight is not the per-unit product weight. MTBF, minimum 1679.6 K hours, Telcordia SR-332 (Bellcore); 213.8 K hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue edition MPQ-200-SPEC 2024-10-30; combined PDF pages 26–28. PACKING is a catalogue single-unit reference, not an independently weighed net or shipping mass. MTBF is a statistical estimate under the stated methods.

    $209.46

  • MPQ-200B

    MEAN WELL MPQ-200 series: Quad-Output Medical AC/DC Power Supply - MPQ-200B

    MEAN WELL MPQ-200B is a PCB-type four-output medical AC/DC power supply. It provides CH1 5 V, CH2 12 V, CH3 −5 V, CH4 −12 V. The total continuous output is limited to 140 W with natural convection or 200 W with at least 25 CFM forced airflow, together with every channel limit and applicable derating. Product Datasheet Download MEAN WELL MPQ-200 Datasheet (PDF) The MPQ-200 section is on PDF pages 26, 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Configuration Complete model MPQ-200B Output arrangement 4 outputs sharing the stated COM reference; polarity is shown separately for every channel. Construction PCB assembly for installation inside equipment. Nominal efficiency, typical 78%. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. Combined Load and Peak Limits Total continuous output 140 W maximum with natural convection; 200 W maximum with 25 CFM forced air. Individual channel limits also apply. Peak-current operation The peak-current column requires a 25 CFM fan. Maximum duty cycle is 33% within every 30 seconds, with average output power not exceeding rated power. Channel 1 voltage adjustment −5% to +10% of nominal CH1 voltage via the potentiometer; for 5 V CH1 this calculates to 4.75–5.5 V. The channel maximums are not permission to load every output to its maximum simultaneously. Keep the sum of the absolute channel output powers within the applicable combined power limit and meet all minimum-load requirements. Negative output voltage denotes polarity, not negative delivered power. The peak-current table does not print a separate combined peak-wattage limit or an independent pulse-duration value. The per-channel peak limits must not be added together as an allowable combined peak load. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Voltage tolerance includes set-up tolerance, line regulation and load regulation. CH1 Electrical Ratings Output voltage 5 V. Rated current 15 A. Minimum load 3 A. Convection maximum current 12 A. Current with 25 CFM fan 15 A. Peak current with 25 CFM fan 18 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH2 Electrical Ratings Output voltage 12 V. Rated current 7 A. Minimum load 0.7 A. Convection maximum current 5.3 A. Current with 25 CFM fan 7 A. Peak current with 25 CFM fan 8.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±8.0%. Line regulation ±1.0%. Load regulation ±5.0%. CH3 Electrical Ratings Output voltage −5 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. CH4 Electrical Ratings Output voltage −12 V. Rated current 2 A. Minimum load 0 A. Convection maximum current 1 A. Current with 25 CFM fan 2 A. Peak current with 25 CFM fan 2.4 A; subject to the combined peak and average-power conditions. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±5.0%. Line regulation ±0.5%. Load regulation ±1.0%. Input and Start-Up Input range 90–264 VAC, 47–63 Hz, or 127–370 VDC. Apply low-input derating. Input current, typical 3.5 A at 115 VAC; 1.6 A at 230 VAC, at 60 Hz and full output load. Cold-start inrush, typical Less than 25 A at 115 VAC; less than 40 A at 230 VAC, limited by internal thermistors. Set-up / rise time 1000 / 20 ms at 230 VAC; 3000 / 20 ms at 115 VAC, full load. Hold-up time, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load. Switching-frequency reference 100 kHz. Power factor, typical >0.95 at 230 VAC and >0.98 at 115 VAC, full load. Protection Short circuit / overload Hiccup protection at 120–160% rated load, with automatic recovery after the fault is removed. Overvoltage protection CH1 only, at 115–135% of its rated voltage. The output shuts down when activated; the page does not specify a recovery method. Overtemperature protection TSW1 senses the power-transistor heat sink. At 95°C the output shuts down; it recovers automatically after temperature falls. This is a heat-sink sensor threshold, not an ambient-temperature rating. Protection thresholds are fault limits, not additional operating ratings. Control, Status and Remote Sense Power Good / Power Fail TTL high indicates power good; low indicates failure. At 90% of rated output voltage, the +5 V TTL signal is asserted after 10–500 ms. It goes low at least 1 ms before output falls below 90% of rated voltage. Remote ON/OFF Across RC+ and RC−: 0–0.8 V turns the output on; 4–10 V turns it off. The catalogue prints the sink-current reference as <4–10 mA; confirm interface drive requirements from the manufacturer application instructions. Remote sense CN4 pin 5 RS+ and pin 2 RS−. Observe the correct output polarity and the manufacturer wiring instructions; these pages do not state a maximum compensation voltage. Power indication The mechanical drawing marks the LED power indicator. The status signal is available at CN4 pin 1 PG with pin 3 GND. Remote control is on pin 4 RC+ and pin 6 RC−; these functions must not be inferred from the connector position alone. No standby output is specified for these four-output models. Derating and Environment Working temperature −20 to +70°C, subject to the cooling curve. Thermal curve Horizontal mounting: natural convection allows 70% of the 200 W family rating through 40°C, falling to 30% at 60°C. With 25 CFM forced air, 100% is available through 50°C, falling to 40% at 70°C. The no-fan curve ends at 60°C. Input-voltage curve, 60 Hz 80% load at 90 VAC; 100% at 115 VAC through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage conditions −40 to +85°C; 10–90% RH. Temperature coefficient ±0.04%/°C on all outputs at full load, over 0–50°C. Vibration 10–500 Hz, 2 G; 10-minute cycles, six cycles / 60 minutes along each X, Y and Z axis. Altitude condition Above 2000 m, reduce allowable ambient temperature by 3.5°C per additional 1000 m for fanless operation, or 5°C per additional 1000 m for fan-cooled operation. No absolute operating-altitude maximum is specified on these MPQ pages. Apply temperature, input-voltage, cooling and channel loading restrictions together. Do not extrapolate beyond the plotted curve or treat a series name as the guaranteed output wattage. Installation and Mechanical Details Dimensions, L × W × H 177.8 × 107.2 × 35.5 mm. Drawing dimensions Millimetres, general tolerance ±1 mm; 4 x Ø3.96 mm on 165.1 × 95.25 mm centres. Underside clearance 3 mm maximum component projection is shown below the board; allow the installation clearance required by the manufacturer. It is not a mounting-screw penetration rating. Mounting references Edge references 6.35 mm and 6.1 mm; the FG position is marked near the AC input. Forced-air installation At least 25 CFM, fan 15 cm from the illustrated board edge, with the shown airflow direction. Use the applicable complete mechanical drawing and installation instructions. The listed mating connector references, external fan and mounting hardware are not stated to be supplied accessories. Maintain the marked protective-ground connection and verify safety and EMC in the final equipment. Connectors and Mating References AC input CN1 JST B3P-VH or equivalent: pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing reference JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Main output CN2 and CN3 Two JST B8P-VH connectors or equivalents, using combined numbering 1–16: pins 1–4 V1; 5–11 COM; 12–13 V2; 14 V3; 15 absent; 16 V4. Use the signed channel voltages listed above. Signal connector CN4 JS-2008-03*2 or equivalent: 1 PG, 2 RS−, 3 GND, 4 RC+, 5 RS+, 6 RC−. Mating housing JS-2007-03*2; terminal JS-2007-T or equivalent. The main input/output connectors use the JST VHR housing family and JST SVH-21T-P1.1 contact reference. Select the complete mating housing for the required circuit count and wire size; loose mating parts and any external fan are not stated as included. Medical Isolation, Leakage and Safety Isolation level Primary–secondary: 2 MOPP. No additional MOPP levels are assigned here. Withstand voltage Input–output 4 kVAC; input–FG 2 kVAC; output–FG 1.5 kVAC. Insulation resistance Greater than 100 MΩ at 500 VDC, for input–output, input–FG and output–FG. Leakage current Earth leakage <150 µA at 264 VAC; touch current <100 µA at 264 VAC. Touch current is measured from primary input to DC output. The safety table lists IEC60601-1:2005+A1; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; and EAC TP TC004. The cover also carries UL60950-1. Verify the applicable component approval in the final equipment configuration. This medical power supply is a component, not a certification of the finished medical equipment. Suitability for BF applications requires appropriate system consideration, including patient isolation, leakage current, protective grounding and EMC. EMC and System Integration Conducted and radiated emissions: BS EN/EN55011 Class B. Harmonic current: BS EN/EN61000-3-2; voltage flicker: BS EN/EN61000-3-3; EAC TP TC020 is listed. The immunity table references EN61000-4-2 ESD: 8 kV air (Level 3) and 4 kV contact (Level 2); EN61000-4-3 RF field: 3 and 10 V/m; EN61000-4-4 EFT: 1 and 2 kV at 5 kHz; EN61000-4-5 surge: 2 kV line–line and 4 kV line–earth; EN61000-4-8 magnetic field: 3 and 10 A/m. EN61000-4-11 voltage dips/interruptions, EN61000-4-6 conducted RF and ENV50204 at 900 MHz are also referenced. Use the applicable manufacturer test report for precise conducted-RF and digital-phone test-level details. EMC tests used the unit on a 360 × 360 mm metal plate, 1 mm thick. This component is intended for installation in final equipment; reconfirm EMC compliance in the completed system. Weight and Reliability Catalogue single-unit reference 0.66 kg = 660 g per unit, from the PACKING entry. Carton reference 24 pieces / 16.8 kg / 1.17 CUFT; carton weight is not the per-unit product weight. MTBF, minimum 1679.6 K hours, Telcordia SR-332 (Bellcore); 213.8 K hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue edition MPQ-200-SPEC 2024-10-30; combined PDF pages 26–28. PACKING is a catalogue single-unit reference, not an independently weighed net or shipping mass. MTBF is a statistical estimate under the stated methods.

    $209.46

  • RPTG-160D-C

    MEAN WELL RPT-160 series: Enclosed Triple Output Medical AC/DC Power Supply - RPTG-160D-C

    MEAN WELL RPTG-160D-C is an enclosed casing triple-output AC/DC power supply with 5 V / 12 V / 24 V rails. The catalogue combined ratings are 141.5 W with 20.5 CFM airflow and 93.8 W with natural convection, subject to the individual channel limits and standby-power notes below. This G model adds a 5 V standby rail and PS-ON control. Product Datasheet Download MEAN WELL RPT-160 Datasheet (PDF) The RPT-160 section is on PDF pages 19, 20, 21, 22, 23, 24, 25. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPTG-160D-C. Configuration Optional enclosed type. G: green model with standby and PS-ON. Output code D: CH1 / CH2 / CH3 = 5 V / 12 V / 24 V. System grounding Class I with protective ground (FG). Both M1 and M2 safety-ground points must be grounded. Typical applications Oral irrigators, hemodialysis equipment, medical monitors, sleep-apnea devices and pumps. BF application requires appropriate complete-system consideration. Isolation, leakage, protective grounding and final-equipment EMC must be assessed for the actual installation. The optional enclosed version has a different approval status from the PCB version; see the safety section. Combined Output and Test Conditions Combined rated power, 20.5 CFM 141.5 W, as printed in the model table. Combined rated power, convection 93.8 W, as printed in the model table. CH1 adjustment 5–5.5 V using SVR1; no independent CH2/CH3 adjustment range is stated. Efficiency, typical 83%. The rated-power footnotes include 5Vsb at 0.8 A with 20.5 CFM, or 0.6 A with natural convection. Standby is already included in these totals; do not add it again. Keep every channel within its stated minimum and maximum load, and meet the applicable combined-power limit, cooling and derating conditions simultaneously. The series name is not a per-channel wattage rating. Unless stated otherwise, specifications are measured at 230 VAC, rated load and 25°C. Ripple/noise is measured over 20 MHz with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Tolerance includes set-up tolerance, line regulation and load regulation. CH1 Output Nominal voltage 5 V relative to COM. Rated current, 20.5 CFM 10.5 A. Load-current range, 20.5 CFM 0.3–10.5 A. Load-current range, convection 0.3–7.6 A. Minimum load 0.3 A in both stated cooling modes. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal voltage 12 V relative to COM. Rated current, 20.5 CFM 4.8 A. Load-current range, 20.5 CFM 0.2–4.8 A. Load-current range, convection 0.2–2.5 A. Minimum load 0.2 A in both stated cooling modes. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage 24 V relative to COM. Rated current, 20.5 CFM 1.14 A. Load-current range, 20.5 CFM 0.15–1.14 A. Load-current range, convection 0.15–0.95 A. Minimum load 0.15 A in both stated cooling modes. Ripple and noise, maximum 120 mVp-p. Voltage tolerance +7% / -5%. Line regulation ±1.0%. Load regulation -3% / +4%. Input, Timing and Leakage Input 90–264 VAC or 127–370 VDC; apply low-input derating. AC frequency 47–63 Hz. Power-factor correction Built-in active PFC; at full load PF >0.93 at 230 VAC and >0.98 at 115 VAC. AC current, typical 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise 1800 ms / 30 ms at 230 VAC; 3500 ms / 30 ms at 115 VAC, full load. Hold-up, typical 30 ms at 230 VAC; 20 ms at 115 VAC, full load. Earth leakage Less than 160 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Block-diagram frequency 100 kHz. Protection Short circuit / overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage CH1 threshold: 5.7–6.8 V. Output shuts down; re-power on to recover. Overtemperature, TSW1 Output shuts down and automatically recovers after temperature decreases. Overtemperature, TSW2 Output shuts down; re-power on to recover. Protection thresholds are not an overload operating allowance. The two thermal-protection responses are distinct. Status and Standby Control Power Good / Power Fail Catalogue timing: 10 ms < PG < 500 ms; PF >1 ms. The status connector is CN3, pin 1 PG and pin 2 GND. No separate PF connector pin is assigned. Indicator An LED power indicator is marked on the PCB mechanical drawing. 5 V standby 5 V at up to 0.6 A without a fan, or 0.8 A with 20.5 CFM; tolerance ±2%, ripple/noise 50 mVp-p maximum. PS-ON High, 2–5 V: power on. Low, 0–0.5 V: power off. CN901 pin 1 is PS/ON; pins 2 and 4 are GND. The illustrated transistor interface is marked 5 mA maximum. Low-power condition Less than 0.75 W using PS-ON control. This is a G-model controlled-off condition, not an unconditional output-on no-load rating. Derating and Environment Ambient range −20 to +70°C, subject to the cooling-mode curve. Horizontal-mounting temperature curve On the common catalogue percentage scale, the enclosed convection curve is 95% through 40°C and falls to 38% at 60°C; with 20.5 CFM it is 95% through 50°C and falls to 38% at 70°C. Use the enclosed model’s reduced current and combined-power ratings; the graph is not an alternative higher wattage specification. Input-voltage curve, 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude Up to 3000 m. Above 2000 m, reduce allowable ambient temperature by 3.5°C per 1000 m for fanless operation, or 5°C per 1000 m for fan-cooled operation. Combine the temperature, input-voltage, altitude and loading limits. Natural-convection curves end at 60°C; the 70°C endpoint requires the stated forced-air condition. Do not infer a pulse or peak-power allowance. Mechanical Installation and Cooling Size, L × W × H 130 × 86 × 43 mm. Drawing PDF page 24; dimensions in millimetres. Enclosure Optional -C enclosure, Case No.247A. Bottom mounting Four M3 positions on a 120 × 50 mm pattern; 5 mm and 18.3 mm edge references. Side mounting The side drawing marks four M3 L=4 positions and separate 120 mm / 110.5 mm dimensions; follow the complete drawing for their locations. Screw penetration and torque The installation table specifies M3, maximum penetration 2 mm for both listed hole groups, and 4–6 kgf-cm torque. Select screw length for the actual mounting thickness; do not treat the side-view L=4 marking as permission to exceed the installation limit. External airflow placement 20.5 CFM external fan, 5 cm from the enclosure, blowing in the shown direction; fan centre is referenced 65 mm from the output-side edge. Grounding and heat sinks M1 and M2 are safety-ground points and both must be grounded. HS1, HS2 and HS3 must not be shorted. Adjustment and fuse references SVR1 is the adjustment reference; the drawing marks FS1 and FS2, without assigning a replacement fuse ordering code. The shown fan establishes the forced-air test/installation condition; a fan, mounting screws or loose mating connectors are not stated as included. Keep the indicated airflow path and clearances open. No separate mounting-kit ordering code is given. Connections and Mating Components AC input CN1 JST B3P-VH or equivalent: pin 1 AC/L, pin 2 no pin, pin 3 AC/N. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Three-output connector CN2 JST B8P-VH or equivalent: pins 1–4 COM, pins 5–6 CH1, pin 7 CH2, pin 8 CH3. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Power Good connector CN3 JST B2B-XH or equivalent: pin 1 PG, pin 2 GND. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. Standby/control CN901 Catalogue connector reference JST B-XH or equivalent: pin 1 PS/ON, pins 2 and 4 GND, pin 3 5VSB. Mating housing JST XHP or equivalent; terminal reference JST SXH-001T or equivalent. VHR, XHP, B-XH and SXH-001T are the abbreviated references printed in this catalogue. Select the exact position count and complete manufacturer ordering suffix for the required mating part; these pages do not provide every suffix. Do not substitute another series’ pin assignment. Safety, Isolation and EMC Version-specific approval status The enclosed specification states design reference to IEC60601-1, EAC TP TC004 and TUV BS EN/EN60601-1, with CB/TUV pending in this catalogue revision. Do not treat the PCB approval list, including ANSI/AAMI, as an approval for this -C product. Isolation Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11): conducted Class B and radiated Class B in the Class I configuration with FG. Harmonics: BS EN/EN61000-3-2 Class A; voltage flicker: BS EN/EN61000-3-3. Equipment configuration Use Class I with FG; the -C version is not suitable for a Class II system without FG. Immunity: BS EN/EN55035 and BS EN/EN60601-1-2. ESD (-4-2): level 4, 15 kV air / 8 kV contact. RF field (-4-3): level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT (-4-4): level 3, 2 kV. Surge (-4-5): level 3, 2 kV line–FG / 1 kV line–line. Conducted susceptibility (-4-6): level 3, 10 V. Magnetic field (-4-8): level 4, 30 A/m. Dips/interruption (-4-11): 100% dip for 1 period, 30% dip for 25 periods, 100% interruption for 250 periods. The catalogue EMC setup uses a 360 × 360 × 1 mm metal plate. This power supply is an installation component; re-confirm compliance in the finished equipment. Weight, Reliability and Catalogue Single-unit catalogue weight 490 g (0.49 kg), explicitly printed per unit in PACKING; a catalogue packing reference, not a measured net or shipping-parcel weight. Packing 24 pieces / 12.8 kg / 0.77 CUFT. MTBF, minimum estimates 1719.1 thousand hours, Telcordia SR-332 (Bellcore); 175.1 thousand hours, MIL-HDBK-217F at 25°C. Lifetime statement The series feature list states a lifetime greater than 85,000 hours, without test conditions on these pages; it is not a guaranteed service life for every installation. Warranty Three-year manufacturer warranty, subject to applicable terms. Catalogue RPT-160-SPEC, 2024-04-15; combined PDF pages 19–25.

    $178.41

  • RPTG-160D-C

    MEAN WELL RPT-160 series: Enclosed Triple Output Medical AC/DC Power Supply - RPTG-160D-C

    MEAN WELL RPTG-160D-C is an enclosed casing triple-output AC/DC power supply with 5 V / 12 V / 24 V rails. The catalogue combined ratings are 141.5 W with 20.5 CFM airflow and 93.8 W with natural convection, subject to the individual channel limits and standby-power notes below. This G model adds a 5 V standby rail and PS-ON control. Product Datasheet Download MEAN WELL RPT-160 Datasheet (PDF) The RPT-160 section is on PDF pages 19, 20, 21, 22, 23, 24, 25. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPTG-160D-C. Configuration Optional enclosed type. G: green model with standby and PS-ON. Output code D: CH1 / CH2 / CH3 = 5 V / 12 V / 24 V. System grounding Class I with protective ground (FG). Both M1 and M2 safety-ground points must be grounded. Typical applications Oral irrigators, hemodialysis equipment, medical monitors, sleep-apnea devices and pumps. BF application requires appropriate complete-system consideration. Isolation, leakage, protective grounding and final-equipment EMC must be assessed for the actual installation. The optional enclosed version has a different approval status from the PCB version; see the safety section. Combined Output and Test Conditions Combined rated power, 20.5 CFM 141.5 W, as printed in the model table. Combined rated power, convection 93.8 W, as printed in the model table. CH1 adjustment 5–5.5 V using SVR1; no independent CH2/CH3 adjustment range is stated. Efficiency, typical 83%. The rated-power footnotes include 5Vsb at 0.8 A with 20.5 CFM, or 0.6 A with natural convection. Standby is already included in these totals; do not add it again. Keep every channel within its stated minimum and maximum load, and meet the applicable combined-power limit, cooling and derating conditions simultaneously. The series name is not a per-channel wattage rating. Unless stated otherwise, specifications are measured at 230 VAC, rated load and 25°C. Ripple/noise is measured over 20 MHz with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Tolerance includes set-up tolerance, line regulation and load regulation. CH1 Output Nominal voltage 5 V relative to COM. Rated current, 20.5 CFM 10.5 A. Load-current range, 20.5 CFM 0.3–10.5 A. Load-current range, convection 0.3–7.6 A. Minimum load 0.3 A in both stated cooling modes. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal voltage 12 V relative to COM. Rated current, 20.5 CFM 4.8 A. Load-current range, 20.5 CFM 0.2–4.8 A. Load-current range, convection 0.2–2.5 A. Minimum load 0.2 A in both stated cooling modes. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage 24 V relative to COM. Rated current, 20.5 CFM 1.14 A. Load-current range, 20.5 CFM 0.15–1.14 A. Load-current range, convection 0.15–0.95 A. Minimum load 0.15 A in both stated cooling modes. Ripple and noise, maximum 120 mVp-p. Voltage tolerance +7% / -5%. Line regulation ±1.0%. Load regulation -3% / +4%. Input, Timing and Leakage Input 90–264 VAC or 127–370 VDC; apply low-input derating. AC frequency 47–63 Hz. Power-factor correction Built-in active PFC; at full load PF >0.93 at 230 VAC and >0.98 at 115 VAC. AC current, typical 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise 1800 ms / 30 ms at 230 VAC; 3500 ms / 30 ms at 115 VAC, full load. Hold-up, typical 30 ms at 230 VAC; 20 ms at 115 VAC, full load. Earth leakage Less than 160 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Block-diagram frequency 100 kHz. Protection Short circuit / overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage CH1 threshold: 5.7–6.8 V. Output shuts down; re-power on to recover. Overtemperature, TSW1 Output shuts down and automatically recovers after temperature decreases. Overtemperature, TSW2 Output shuts down; re-power on to recover. Protection thresholds are not an overload operating allowance. The two thermal-protection responses are distinct. Status and Standby Control Power Good / Power Fail Catalogue timing: 10 ms < PG < 500 ms; PF >1 ms. The status connector is CN3, pin 1 PG and pin 2 GND. No separate PF connector pin is assigned. Indicator An LED power indicator is marked on the PCB mechanical drawing. 5 V standby 5 V at up to 0.6 A without a fan, or 0.8 A with 20.5 CFM; tolerance ±2%, ripple/noise 50 mVp-p maximum. PS-ON High, 2–5 V: power on. Low, 0–0.5 V: power off. CN901 pin 1 is PS/ON; pins 2 and 4 are GND. The illustrated transistor interface is marked 5 mA maximum. Low-power condition Less than 0.75 W using PS-ON control. This is a G-model controlled-off condition, not an unconditional output-on no-load rating. Derating and Environment Ambient range −20 to +70°C, subject to the cooling-mode curve. Horizontal-mounting temperature curve On the common catalogue percentage scale, the enclosed convection curve is 95% through 40°C and falls to 38% at 60°C; with 20.5 CFM it is 95% through 50°C and falls to 38% at 70°C. Use the enclosed model’s reduced current and combined-power ratings; the graph is not an alternative higher wattage specification. Input-voltage curve, 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude Up to 3000 m. Above 2000 m, reduce allowable ambient temperature by 3.5°C per 1000 m for fanless operation, or 5°C per 1000 m for fan-cooled operation. Combine the temperature, input-voltage, altitude and loading limits. Natural-convection curves end at 60°C; the 70°C endpoint requires the stated forced-air condition. Do not infer a pulse or peak-power allowance. Mechanical Installation and Cooling Size, L × W × H 130 × 86 × 43 mm. Drawing PDF page 24; dimensions in millimetres. Enclosure Optional -C enclosure, Case No.247A. Bottom mounting Four M3 positions on a 120 × 50 mm pattern; 5 mm and 18.3 mm edge references. Side mounting The side drawing marks four M3 L=4 positions and separate 120 mm / 110.5 mm dimensions; follow the complete drawing for their locations. Screw penetration and torque The installation table specifies M3, maximum penetration 2 mm for both listed hole groups, and 4–6 kgf-cm torque. Select screw length for the actual mounting thickness; do not treat the side-view L=4 marking as permission to exceed the installation limit. External airflow placement 20.5 CFM external fan, 5 cm from the enclosure, blowing in the shown direction; fan centre is referenced 65 mm from the output-side edge. Grounding and heat sinks M1 and M2 are safety-ground points and both must be grounded. HS1, HS2 and HS3 must not be shorted. Adjustment and fuse references SVR1 is the adjustment reference; the drawing marks FS1 and FS2, without assigning a replacement fuse ordering code. The shown fan establishes the forced-air test/installation condition; a fan, mounting screws or loose mating connectors are not stated as included. Keep the indicated airflow path and clearances open. No separate mounting-kit ordering code is given. Connections and Mating Components AC input CN1 JST B3P-VH or equivalent: pin 1 AC/L, pin 2 no pin, pin 3 AC/N. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Three-output connector CN2 JST B8P-VH or equivalent: pins 1–4 COM, pins 5–6 CH1, pin 7 CH2, pin 8 CH3. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Power Good connector CN3 JST B2B-XH or equivalent: pin 1 PG, pin 2 GND. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. Standby/control CN901 Catalogue connector reference JST B-XH or equivalent: pin 1 PS/ON, pins 2 and 4 GND, pin 3 5VSB. Mating housing JST XHP or equivalent; terminal reference JST SXH-001T or equivalent. VHR, XHP, B-XH and SXH-001T are the abbreviated references printed in this catalogue. Select the exact position count and complete manufacturer ordering suffix for the required mating part; these pages do not provide every suffix. Do not substitute another series’ pin assignment. Safety, Isolation and EMC Version-specific approval status The enclosed specification states design reference to IEC60601-1, EAC TP TC004 and TUV BS EN/EN60601-1, with CB/TUV pending in this catalogue revision. Do not treat the PCB approval list, including ANSI/AAMI, as an approval for this -C product. Isolation Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11): conducted Class B and radiated Class B in the Class I configuration with FG. Harmonics: BS EN/EN61000-3-2 Class A; voltage flicker: BS EN/EN61000-3-3. Equipment configuration Use Class I with FG; the -C version is not suitable for a Class II system without FG. Immunity: BS EN/EN55035 and BS EN/EN60601-1-2. ESD (-4-2): level 4, 15 kV air / 8 kV contact. RF field (-4-3): level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT (-4-4): level 3, 2 kV. Surge (-4-5): level 3, 2 kV line–FG / 1 kV line–line. Conducted susceptibility (-4-6): level 3, 10 V. Magnetic field (-4-8): level 4, 30 A/m. Dips/interruption (-4-11): 100% dip for 1 period, 30% dip for 25 periods, 100% interruption for 250 periods. The catalogue EMC setup uses a 360 × 360 × 1 mm metal plate. This power supply is an installation component; re-confirm compliance in the finished equipment. Weight, Reliability and Catalogue Single-unit catalogue weight 490 g (0.49 kg), explicitly printed per unit in PACKING; a catalogue packing reference, not a measured net or shipping-parcel weight. Packing 24 pieces / 12.8 kg / 0.77 CUFT. MTBF, minimum estimates 1719.1 thousand hours, Telcordia SR-332 (Bellcore); 175.1 thousand hours, MIL-HDBK-217F at 25°C. Lifetime statement The series feature list states a lifetime greater than 85,000 hours, without test conditions on these pages; it is not a guaranteed service life for every installation. Warranty Three-year manufacturer warranty, subject to applicable terms. Catalogue RPT-160-SPEC, 2024-04-15; combined PDF pages 19–25.

    $178.41

  • RPTG-160D-C

    MEAN WELL RPT-160 series: Enclosed Triple Output Medical AC/DC Power Supply - RPTG-160D-C

    MEAN WELL RPTG-160D-C is an enclosed casing triple-output AC/DC power supply with 5 V / 12 V / 24 V rails. The catalogue combined ratings are 141.5 W with 20.5 CFM airflow and 93.8 W with natural convection, subject to the individual channel limits and standby-power notes below. This G model adds a 5 V standby rail and PS-ON control. Product Datasheet Download MEAN WELL RPT-160 Datasheet (PDF) The RPT-160 section is on PDF pages 19, 20, 21, 22, 23, 24, 25. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPTG-160D-C. Configuration Optional enclosed type. G: green model with standby and PS-ON. Output code D: CH1 / CH2 / CH3 = 5 V / 12 V / 24 V. System grounding Class I with protective ground (FG). Both M1 and M2 safety-ground points must be grounded. Typical applications Oral irrigators, hemodialysis equipment, medical monitors, sleep-apnea devices and pumps. BF application requires appropriate complete-system consideration. Isolation, leakage, protective grounding and final-equipment EMC must be assessed for the actual installation. The optional enclosed version has a different approval status from the PCB version; see the safety section. Combined Output and Test Conditions Combined rated power, 20.5 CFM 141.5 W, as printed in the model table. Combined rated power, convection 93.8 W, as printed in the model table. CH1 adjustment 5–5.5 V using SVR1; no independent CH2/CH3 adjustment range is stated. Efficiency, typical 83%. The rated-power footnotes include 5Vsb at 0.8 A with 20.5 CFM, or 0.6 A with natural convection. Standby is already included in these totals; do not add it again. Keep every channel within its stated minimum and maximum load, and meet the applicable combined-power limit, cooling and derating conditions simultaneously. The series name is not a per-channel wattage rating. Unless stated otherwise, specifications are measured at 230 VAC, rated load and 25°C. Ripple/noise is measured over 20 MHz with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Tolerance includes set-up tolerance, line regulation and load regulation. CH1 Output Nominal voltage 5 V relative to COM. Rated current, 20.5 CFM 10.5 A. Load-current range, 20.5 CFM 0.3–10.5 A. Load-current range, convection 0.3–7.6 A. Minimum load 0.3 A in both stated cooling modes. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal voltage 12 V relative to COM. Rated current, 20.5 CFM 4.8 A. Load-current range, 20.5 CFM 0.2–4.8 A. Load-current range, convection 0.2–2.5 A. Minimum load 0.2 A in both stated cooling modes. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage 24 V relative to COM. Rated current, 20.5 CFM 1.14 A. Load-current range, 20.5 CFM 0.15–1.14 A. Load-current range, convection 0.15–0.95 A. Minimum load 0.15 A in both stated cooling modes. Ripple and noise, maximum 120 mVp-p. Voltage tolerance +7% / -5%. Line regulation ±1.0%. Load regulation -3% / +4%. Input, Timing and Leakage Input 90–264 VAC or 127–370 VDC; apply low-input derating. AC frequency 47–63 Hz. Power-factor correction Built-in active PFC; at full load PF >0.93 at 230 VAC and >0.98 at 115 VAC. AC current, typical 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise 1800 ms / 30 ms at 230 VAC; 3500 ms / 30 ms at 115 VAC, full load. Hold-up, typical 30 ms at 230 VAC; 20 ms at 115 VAC, full load. Earth leakage Less than 160 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Block-diagram frequency 100 kHz. Protection Short circuit / overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage CH1 threshold: 5.7–6.8 V. Output shuts down; re-power on to recover. Overtemperature, TSW1 Output shuts down and automatically recovers after temperature decreases. Overtemperature, TSW2 Output shuts down; re-power on to recover. Protection thresholds are not an overload operating allowance. The two thermal-protection responses are distinct. Status and Standby Control Power Good / Power Fail Catalogue timing: 10 ms < PG < 500 ms; PF >1 ms. The status connector is CN3, pin 1 PG and pin 2 GND. No separate PF connector pin is assigned. Indicator An LED power indicator is marked on the PCB mechanical drawing. 5 V standby 5 V at up to 0.6 A without a fan, or 0.8 A with 20.5 CFM; tolerance ±2%, ripple/noise 50 mVp-p maximum. PS-ON High, 2–5 V: power on. Low, 0–0.5 V: power off. CN901 pin 1 is PS/ON; pins 2 and 4 are GND. The illustrated transistor interface is marked 5 mA maximum. Low-power condition Less than 0.75 W using PS-ON control. This is a G-model controlled-off condition, not an unconditional output-on no-load rating. Derating and Environment Ambient range −20 to +70°C, subject to the cooling-mode curve. Horizontal-mounting temperature curve On the common catalogue percentage scale, the enclosed convection curve is 95% through 40°C and falls to 38% at 60°C; with 20.5 CFM it is 95% through 50°C and falls to 38% at 70°C. Use the enclosed model’s reduced current and combined-power ratings; the graph is not an alternative higher wattage specification. Input-voltage curve, 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude Up to 3000 m. Above 2000 m, reduce allowable ambient temperature by 3.5°C per 1000 m for fanless operation, or 5°C per 1000 m for fan-cooled operation. Combine the temperature, input-voltage, altitude and loading limits. Natural-convection curves end at 60°C; the 70°C endpoint requires the stated forced-air condition. Do not infer a pulse or peak-power allowance. Mechanical Installation and Cooling Size, L × W × H 130 × 86 × 43 mm. Drawing PDF page 24; dimensions in millimetres. Enclosure Optional -C enclosure, Case No.247A. Bottom mounting Four M3 positions on a 120 × 50 mm pattern; 5 mm and 18.3 mm edge references. Side mounting The side drawing marks four M3 L=4 positions and separate 120 mm / 110.5 mm dimensions; follow the complete drawing for their locations. Screw penetration and torque The installation table specifies M3, maximum penetration 2 mm for both listed hole groups, and 4–6 kgf-cm torque. Select screw length for the actual mounting thickness; do not treat the side-view L=4 marking as permission to exceed the installation limit. External airflow placement 20.5 CFM external fan, 5 cm from the enclosure, blowing in the shown direction; fan centre is referenced 65 mm from the output-side edge. Grounding and heat sinks M1 and M2 are safety-ground points and both must be grounded. HS1, HS2 and HS3 must not be shorted. Adjustment and fuse references SVR1 is the adjustment reference; the drawing marks FS1 and FS2, without assigning a replacement fuse ordering code. The shown fan establishes the forced-air test/installation condition; a fan, mounting screws or loose mating connectors are not stated as included. Keep the indicated airflow path and clearances open. No separate mounting-kit ordering code is given. Connections and Mating Components AC input CN1 JST B3P-VH or equivalent: pin 1 AC/L, pin 2 no pin, pin 3 AC/N. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Three-output connector CN2 JST B8P-VH or equivalent: pins 1–4 COM, pins 5–6 CH1, pin 7 CH2, pin 8 CH3. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Power Good connector CN3 JST B2B-XH or equivalent: pin 1 PG, pin 2 GND. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. Standby/control CN901 Catalogue connector reference JST B-XH or equivalent: pin 1 PS/ON, pins 2 and 4 GND, pin 3 5VSB. Mating housing JST XHP or equivalent; terminal reference JST SXH-001T or equivalent. VHR, XHP, B-XH and SXH-001T are the abbreviated references printed in this catalogue. Select the exact position count and complete manufacturer ordering suffix for the required mating part; these pages do not provide every suffix. Do not substitute another series’ pin assignment. Safety, Isolation and EMC Version-specific approval status The enclosed specification states design reference to IEC60601-1, EAC TP TC004 and TUV BS EN/EN60601-1, with CB/TUV pending in this catalogue revision. Do not treat the PCB approval list, including ANSI/AAMI, as an approval for this -C product. Isolation Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11): conducted Class B and radiated Class B in the Class I configuration with FG. Harmonics: BS EN/EN61000-3-2 Class A; voltage flicker: BS EN/EN61000-3-3. Equipment configuration Use Class I with FG; the -C version is not suitable for a Class II system without FG. Immunity: BS EN/EN55035 and BS EN/EN60601-1-2. ESD (-4-2): level 4, 15 kV air / 8 kV contact. RF field (-4-3): level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT (-4-4): level 3, 2 kV. Surge (-4-5): level 3, 2 kV line–FG / 1 kV line–line. Conducted susceptibility (-4-6): level 3, 10 V. Magnetic field (-4-8): level 4, 30 A/m. Dips/interruption (-4-11): 100% dip for 1 period, 30% dip for 25 periods, 100% interruption for 250 periods. The catalogue EMC setup uses a 360 × 360 × 1 mm metal plate. This power supply is an installation component; re-confirm compliance in the finished equipment. Weight, Reliability and Catalogue Single-unit catalogue weight 490 g (0.49 kg), explicitly printed per unit in PACKING; a catalogue packing reference, not a measured net or shipping-parcel weight. Packing 24 pieces / 12.8 kg / 0.77 CUFT. MTBF, minimum estimates 1719.1 thousand hours, Telcordia SR-332 (Bellcore); 175.1 thousand hours, MIL-HDBK-217F at 25°C. Lifetime statement The series feature list states a lifetime greater than 85,000 hours, without test conditions on these pages; it is not a guaranteed service life for every installation. Warranty Three-year manufacturer warranty, subject to applicable terms. Catalogue RPT-160-SPEC, 2024-04-15; combined PDF pages 19–25.

    $178.41

  • RPT-160D-C

    MEAN WELL RPT-160 series: Enclosed Triple Output Medical AC/DC Power Supply - RPT-160D-C

    MEAN WELL RPT-160D-C is an enclosed casing triple-output AC/DC power supply with 5 V / 12 V / 24 V rails. The catalogue combined ratings are 141.5 W with 20.5 CFM airflow and 93.8 W with natural convection, subject to the individual channel limits and standby-power notes below. This is the basic-function model without the G standby option. Product Datasheet Download MEAN WELL RPT-160 Datasheet (PDF) The RPT-160 section is on PDF pages 19, 20, 21, 22, 23, 24, 25. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPT-160D-C. Configuration Optional enclosed type. No G: basic-function model. Output code D: CH1 / CH2 / CH3 = 5 V / 12 V / 24 V. System grounding Class I with protective ground (FG). Both M1 and M2 safety-ground points must be grounded. Typical applications Oral irrigators, hemodialysis equipment, medical monitors, sleep-apnea devices and pumps. BF application requires appropriate complete-system consideration. Isolation, leakage, protective grounding and final-equipment EMC must be assessed for the actual installation. The optional enclosed version has a different approval status from the PCB version; see the safety section. Combined Output and Test Conditions Combined rated power, 20.5 CFM 141.5 W, as printed in the model table. Combined rated power, convection 93.8 W, as printed in the model table. CH1 adjustment 5–5.5 V using SVR1; no independent CH2/CH3 adjustment range is stated. Efficiency, typical 83%. The rated-power footnotes include 5Vsb at 0.8 A with 20.5 CFM, or 0.6 A with natural convection. This basic model has no G standby output; do not treat an unused standby allowance as extra current on the three main channels. Keep every channel within its stated minimum and maximum load, and meet the applicable combined-power limit, cooling and derating conditions simultaneously. The series name is not a per-channel wattage rating. Unless stated otherwise, specifications are measured at 230 VAC, rated load and 25°C. Ripple/noise is measured over 20 MHz with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Tolerance includes set-up tolerance, line regulation and load regulation. CH1 Output Nominal voltage 5 V relative to COM. Rated current, 20.5 CFM 10.5 A. Load-current range, 20.5 CFM 0.3–10.5 A. Load-current range, convection 0.3–7.6 A. Minimum load 0.3 A in both stated cooling modes. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal voltage 12 V relative to COM. Rated current, 20.5 CFM 4.8 A. Load-current range, 20.5 CFM 0.2–4.8 A. Load-current range, convection 0.2–2.5 A. Minimum load 0.2 A in both stated cooling modes. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage 24 V relative to COM. Rated current, 20.5 CFM 1.14 A. Load-current range, 20.5 CFM 0.15–1.14 A. Load-current range, convection 0.15–0.95 A. Minimum load 0.15 A in both stated cooling modes. Ripple and noise, maximum 120 mVp-p. Voltage tolerance +7% / -5%. Line regulation ±1.0%. Load regulation -3% / +4%. Input, Timing and Leakage Input 90–264 VAC or 127–370 VDC; apply low-input derating. AC frequency 47–63 Hz. Power-factor correction Built-in active PFC; at full load PF >0.93 at 230 VAC and >0.98 at 115 VAC. AC current, typical 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise 1800 ms / 30 ms at 230 VAC; 3500 ms / 30 ms at 115 VAC, full load. Hold-up, typical 30 ms at 230 VAC; 20 ms at 115 VAC, full load. Earth leakage Less than 160 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Block-diagram frequency 100 kHz. Protection Short circuit / overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage CH1 threshold: 5.7–6.8 V. Output shuts down; re-power on to recover. Overtemperature, TSW1 Output shuts down and automatically recovers after temperature decreases. Overtemperature, TSW2 Output shuts down; re-power on to recover. Protection thresholds are not an overload operating allowance. The two thermal-protection responses are distinct. Status and Model Functions Power Good / Power Fail Catalogue timing: 10 ms < PG < 500 ms; PF >1 ms. The status connector is CN3, pin 1 PG and pin 2 GND. No separate PF connector pin is assigned. Indicator An LED power indicator is marked on the PCB mechanical drawing. Model-function boundary 5Vsb, PS-ON and the controlled-off consumption claim are specified for G models and are not assigned to this basic RPT model. Derating and Environment Ambient range −20 to +70°C, subject to the cooling-mode curve. Horizontal-mounting temperature curve On the common catalogue percentage scale, the enclosed convection curve is 95% through 40°C and falls to 38% at 60°C; with 20.5 CFM it is 95% through 50°C and falls to 38% at 70°C. Use the enclosed model’s reduced current and combined-power ratings; the graph is not an alternative higher wattage specification. Input-voltage curve, 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude Up to 3000 m. Above 2000 m, reduce allowable ambient temperature by 3.5°C per 1000 m for fanless operation, or 5°C per 1000 m for fan-cooled operation. Combine the temperature, input-voltage, altitude and loading limits. Natural-convection curves end at 60°C; the 70°C endpoint requires the stated forced-air condition. Do not infer a pulse or peak-power allowance. Mechanical Installation and Cooling Size, L × W × H 130 × 86 × 43 mm. Drawing PDF page 24; dimensions in millimetres. Enclosure Optional -C enclosure, Case No.247A. Bottom mounting Four M3 positions on a 120 × 50 mm pattern; 5 mm and 18.3 mm edge references. Side mounting The side drawing marks four M3 L=4 positions and separate 120 mm / 110.5 mm dimensions; follow the complete drawing for their locations. Screw penetration and torque The installation table specifies M3, maximum penetration 2 mm for both listed hole groups, and 4–6 kgf-cm torque. Select screw length for the actual mounting thickness; do not treat the side-view L=4 marking as permission to exceed the installation limit. External airflow placement 20.5 CFM external fan, 5 cm from the enclosure, blowing in the shown direction; fan centre is referenced 65 mm from the output-side edge. Grounding and heat sinks M1 and M2 are safety-ground points and both must be grounded. HS1, HS2 and HS3 must not be shorted. Adjustment and fuse references SVR1 is the adjustment reference; the drawing marks FS1 and FS2, without assigning a replacement fuse ordering code. The shown fan establishes the forced-air test/installation condition; a fan, mounting screws or loose mating connectors are not stated as included. Keep the indicated airflow path and clearances open. No separate mounting-kit ordering code is given. Connections and Mating Components AC input CN1 JST B3P-VH or equivalent: pin 1 AC/L, pin 2 no pin, pin 3 AC/N. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Three-output connector CN2 JST B8P-VH or equivalent: pins 1–4 COM, pins 5–6 CH1, pin 7 CH2, pin 8 CH3. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Power Good connector CN3 JST B2B-XH or equivalent: pin 1 PG, pin 2 GND. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. VHR, XHP are the abbreviated references printed in this catalogue. Select the exact position count and complete manufacturer ordering suffix for the required mating part; these pages do not provide every suffix. Do not substitute another series’ pin assignment. Safety, Isolation and EMC Version-specific approval status The enclosed specification states design reference to IEC60601-1, EAC TP TC004 and TUV BS EN/EN60601-1, with CB/TUV pending in this catalogue revision. Do not treat the PCB approval list, including ANSI/AAMI, as an approval for this -C product. Isolation Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11): conducted Class B and radiated Class B in the Class I configuration with FG. Harmonics: BS EN/EN61000-3-2 Class A; voltage flicker: BS EN/EN61000-3-3. Equipment configuration Use Class I with FG; the -C version is not suitable for a Class II system without FG. Immunity: BS EN/EN55035 and BS EN/EN60601-1-2. ESD (-4-2): level 4, 15 kV air / 8 kV contact. RF field (-4-3): level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT (-4-4): level 3, 2 kV. Surge (-4-5): level 3, 2 kV line–FG / 1 kV line–line. Conducted susceptibility (-4-6): level 3, 10 V. Magnetic field (-4-8): level 4, 30 A/m. Dips/interruption (-4-11): 100% dip for 1 period, 30% dip for 25 periods, 100% interruption for 250 periods. The catalogue EMC setup uses a 360 × 360 × 1 mm metal plate. This power supply is an installation component; re-confirm compliance in the finished equipment. Weight, Reliability and Catalogue Single-unit catalogue weight 490 g (0.49 kg), explicitly printed per unit in PACKING; a catalogue packing reference, not a measured net or shipping-parcel weight. Packing 24 pieces / 12.8 kg / 0.77 CUFT. MTBF, minimum estimates 1719.1 thousand hours, Telcordia SR-332 (Bellcore); 175.1 thousand hours, MIL-HDBK-217F at 25°C. Lifetime statement The series feature list states a lifetime greater than 85,000 hours, without test conditions on these pages; it is not a guaranteed service life for every installation. Warranty Three-year manufacturer warranty, subject to applicable terms. Catalogue RPT-160-SPEC, 2024-04-15; combined PDF pages 19–25.

    $161.16

  • RPT-160D-C

    MEAN WELL RPT-160 series: Enclosed Triple Output Medical AC/DC Power Supply - RPT-160D-C

    MEAN WELL RPT-160D-C is an enclosed casing triple-output AC/DC power supply with 5 V / 12 V / 24 V rails. The catalogue combined ratings are 141.5 W with 20.5 CFM airflow and 93.8 W with natural convection, subject to the individual channel limits and standby-power notes below. This is the basic-function model without the G standby option. Product Datasheet Download MEAN WELL RPT-160 Datasheet (PDF) The RPT-160 section is on PDF pages 19, 20, 21, 22, 23, 24, 25. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPT-160D-C. Configuration Optional enclosed type. No G: basic-function model. Output code D: CH1 / CH2 / CH3 = 5 V / 12 V / 24 V. System grounding Class I with protective ground (FG). Both M1 and M2 safety-ground points must be grounded. Typical applications Oral irrigators, hemodialysis equipment, medical monitors, sleep-apnea devices and pumps. BF application requires appropriate complete-system consideration. Isolation, leakage, protective grounding and final-equipment EMC must be assessed for the actual installation. The optional enclosed version has a different approval status from the PCB version; see the safety section. Combined Output and Test Conditions Combined rated power, 20.5 CFM 141.5 W, as printed in the model table. Combined rated power, convection 93.8 W, as printed in the model table. CH1 adjustment 5–5.5 V using SVR1; no independent CH2/CH3 adjustment range is stated. Efficiency, typical 83%. The rated-power footnotes include 5Vsb at 0.8 A with 20.5 CFM, or 0.6 A with natural convection. This basic model has no G standby output; do not treat an unused standby allowance as extra current on the three main channels. Keep every channel within its stated minimum and maximum load, and meet the applicable combined-power limit, cooling and derating conditions simultaneously. The series name is not a per-channel wattage rating. Unless stated otherwise, specifications are measured at 230 VAC, rated load and 25°C. Ripple/noise is measured over 20 MHz with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Tolerance includes set-up tolerance, line regulation and load regulation. CH1 Output Nominal voltage 5 V relative to COM. Rated current, 20.5 CFM 10.5 A. Load-current range, 20.5 CFM 0.3–10.5 A. Load-current range, convection 0.3–7.6 A. Minimum load 0.3 A in both stated cooling modes. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal voltage 12 V relative to COM. Rated current, 20.5 CFM 4.8 A. Load-current range, 20.5 CFM 0.2–4.8 A. Load-current range, convection 0.2–2.5 A. Minimum load 0.2 A in both stated cooling modes. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage 24 V relative to COM. Rated current, 20.5 CFM 1.14 A. Load-current range, 20.5 CFM 0.15–1.14 A. Load-current range, convection 0.15–0.95 A. Minimum load 0.15 A in both stated cooling modes. Ripple and noise, maximum 120 mVp-p. Voltage tolerance +7% / -5%. Line regulation ±1.0%. Load regulation -3% / +4%. Input, Timing and Leakage Input 90–264 VAC or 127–370 VDC; apply low-input derating. AC frequency 47–63 Hz. Power-factor correction Built-in active PFC; at full load PF >0.93 at 230 VAC and >0.98 at 115 VAC. AC current, typical 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise 1800 ms / 30 ms at 230 VAC; 3500 ms / 30 ms at 115 VAC, full load. Hold-up, typical 30 ms at 230 VAC; 20 ms at 115 VAC, full load. Earth leakage Less than 160 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Block-diagram frequency 100 kHz. Protection Short circuit / overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage CH1 threshold: 5.7–6.8 V. Output shuts down; re-power on to recover. Overtemperature, TSW1 Output shuts down and automatically recovers after temperature decreases. Overtemperature, TSW2 Output shuts down; re-power on to recover. Protection thresholds are not an overload operating allowance. The two thermal-protection responses are distinct. Status and Model Functions Power Good / Power Fail Catalogue timing: 10 ms < PG < 500 ms; PF >1 ms. The status connector is CN3, pin 1 PG and pin 2 GND. No separate PF connector pin is assigned. Indicator An LED power indicator is marked on the PCB mechanical drawing. Model-function boundary 5Vsb, PS-ON and the controlled-off consumption claim are specified for G models and are not assigned to this basic RPT model. Derating and Environment Ambient range −20 to +70°C, subject to the cooling-mode curve. Horizontal-mounting temperature curve On the common catalogue percentage scale, the enclosed convection curve is 95% through 40°C and falls to 38% at 60°C; with 20.5 CFM it is 95% through 50°C and falls to 38% at 70°C. Use the enclosed model’s reduced current and combined-power ratings; the graph is not an alternative higher wattage specification. Input-voltage curve, 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude Up to 3000 m. Above 2000 m, reduce allowable ambient temperature by 3.5°C per 1000 m for fanless operation, or 5°C per 1000 m for fan-cooled operation. Combine the temperature, input-voltage, altitude and loading limits. Natural-convection curves end at 60°C; the 70°C endpoint requires the stated forced-air condition. Do not infer a pulse or peak-power allowance. Mechanical Installation and Cooling Size, L × W × H 130 × 86 × 43 mm. Drawing PDF page 24; dimensions in millimetres. Enclosure Optional -C enclosure, Case No.247A. Bottom mounting Four M3 positions on a 120 × 50 mm pattern; 5 mm and 18.3 mm edge references. Side mounting The side drawing marks four M3 L=4 positions and separate 120 mm / 110.5 mm dimensions; follow the complete drawing for their locations. Screw penetration and torque The installation table specifies M3, maximum penetration 2 mm for both listed hole groups, and 4–6 kgf-cm torque. Select screw length for the actual mounting thickness; do not treat the side-view L=4 marking as permission to exceed the installation limit. External airflow placement 20.5 CFM external fan, 5 cm from the enclosure, blowing in the shown direction; fan centre is referenced 65 mm from the output-side edge. Grounding and heat sinks M1 and M2 are safety-ground points and both must be grounded. HS1, HS2 and HS3 must not be shorted. Adjustment and fuse references SVR1 is the adjustment reference; the drawing marks FS1 and FS2, without assigning a replacement fuse ordering code. The shown fan establishes the forced-air test/installation condition; a fan, mounting screws or loose mating connectors are not stated as included. Keep the indicated airflow path and clearances open. No separate mounting-kit ordering code is given. Connections and Mating Components AC input CN1 JST B3P-VH or equivalent: pin 1 AC/L, pin 2 no pin, pin 3 AC/N. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Three-output connector CN2 JST B8P-VH or equivalent: pins 1–4 COM, pins 5–6 CH1, pin 7 CH2, pin 8 CH3. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Power Good connector CN3 JST B2B-XH or equivalent: pin 1 PG, pin 2 GND. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. VHR, XHP are the abbreviated references printed in this catalogue. Select the exact position count and complete manufacturer ordering suffix for the required mating part; these pages do not provide every suffix. Do not substitute another series’ pin assignment. Safety, Isolation and EMC Version-specific approval status The enclosed specification states design reference to IEC60601-1, EAC TP TC004 and TUV BS EN/EN60601-1, with CB/TUV pending in this catalogue revision. Do not treat the PCB approval list, including ANSI/AAMI, as an approval for this -C product. Isolation Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11): conducted Class B and radiated Class B in the Class I configuration with FG. Harmonics: BS EN/EN61000-3-2 Class A; voltage flicker: BS EN/EN61000-3-3. Equipment configuration Use Class I with FG; the -C version is not suitable for a Class II system without FG. Immunity: BS EN/EN55035 and BS EN/EN60601-1-2. ESD (-4-2): level 4, 15 kV air / 8 kV contact. RF field (-4-3): level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT (-4-4): level 3, 2 kV. Surge (-4-5): level 3, 2 kV line–FG / 1 kV line–line. Conducted susceptibility (-4-6): level 3, 10 V. Magnetic field (-4-8): level 4, 30 A/m. Dips/interruption (-4-11): 100% dip for 1 period, 30% dip for 25 periods, 100% interruption for 250 periods. The catalogue EMC setup uses a 360 × 360 × 1 mm metal plate. This power supply is an installation component; re-confirm compliance in the finished equipment. Weight, Reliability and Catalogue Single-unit catalogue weight 490 g (0.49 kg), explicitly printed per unit in PACKING; a catalogue packing reference, not a measured net or shipping-parcel weight. Packing 24 pieces / 12.8 kg / 0.77 CUFT. MTBF, minimum estimates 1719.1 thousand hours, Telcordia SR-332 (Bellcore); 175.1 thousand hours, MIL-HDBK-217F at 25°C. Lifetime statement The series feature list states a lifetime greater than 85,000 hours, without test conditions on these pages; it is not a guaranteed service life for every installation. Warranty Three-year manufacturer warranty, subject to applicable terms. Catalogue RPT-160-SPEC, 2024-04-15; combined PDF pages 19–25.

    $161.16

  • RPT-160D-C

    MEAN WELL RPT-160 series: Enclosed Triple Output Medical AC/DC Power Supply - RPT-160D-C

    MEAN WELL RPT-160D-C is an enclosed casing triple-output AC/DC power supply with 5 V / 12 V / 24 V rails. The catalogue combined ratings are 141.5 W with 20.5 CFM airflow and 93.8 W with natural convection, subject to the individual channel limits and standby-power notes below. This is the basic-function model without the G standby option. Product Datasheet Download MEAN WELL RPT-160 Datasheet (PDF) The RPT-160 section is on PDF pages 19, 20, 21, 22, 23, 24, 25. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPT-160D-C. Configuration Optional enclosed type. No G: basic-function model. Output code D: CH1 / CH2 / CH3 = 5 V / 12 V / 24 V. System grounding Class I with protective ground (FG). Both M1 and M2 safety-ground points must be grounded. Typical applications Oral irrigators, hemodialysis equipment, medical monitors, sleep-apnea devices and pumps. BF application requires appropriate complete-system consideration. Isolation, leakage, protective grounding and final-equipment EMC must be assessed for the actual installation. The optional enclosed version has a different approval status from the PCB version; see the safety section. Combined Output and Test Conditions Combined rated power, 20.5 CFM 141.5 W, as printed in the model table. Combined rated power, convection 93.8 W, as printed in the model table. CH1 adjustment 5–5.5 V using SVR1; no independent CH2/CH3 adjustment range is stated. Efficiency, typical 83%. The rated-power footnotes include 5Vsb at 0.8 A with 20.5 CFM, or 0.6 A with natural convection. This basic model has no G standby output; do not treat an unused standby allowance as extra current on the three main channels. Keep every channel within its stated minimum and maximum load, and meet the applicable combined-power limit, cooling and derating conditions simultaneously. The series name is not a per-channel wattage rating. Unless stated otherwise, specifications are measured at 230 VAC, rated load and 25°C. Ripple/noise is measured over 20 MHz with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Tolerance includes set-up tolerance, line regulation and load regulation. CH1 Output Nominal voltage 5 V relative to COM. Rated current, 20.5 CFM 10.5 A. Load-current range, 20.5 CFM 0.3–10.5 A. Load-current range, convection 0.3–7.6 A. Minimum load 0.3 A in both stated cooling modes. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±1.5%. CH2 Output Nominal voltage 12 V relative to COM. Rated current, 20.5 CFM 4.8 A. Load-current range, 20.5 CFM 0.2–4.8 A. Load-current range, convection 0.2–2.5 A. Minimum load 0.2 A in both stated cooling modes. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±5.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage 24 V relative to COM. Rated current, 20.5 CFM 1.14 A. Load-current range, 20.5 CFM 0.15–1.14 A. Load-current range, convection 0.15–0.95 A. Minimum load 0.15 A in both stated cooling modes. Ripple and noise, maximum 120 mVp-p. Voltage tolerance +7% / -5%. Line regulation ±1.0%. Load regulation -3% / +4%. Input, Timing and Leakage Input 90–264 VAC or 127–370 VDC; apply low-input derating. AC frequency 47–63 Hz. Power-factor correction Built-in active PFC; at full load PF >0.93 at 230 VAC and >0.98 at 115 VAC. AC current, typical 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise 1800 ms / 30 ms at 230 VAC; 3500 ms / 30 ms at 115 VAC, full load. Hold-up, typical 30 ms at 230 VAC; 20 ms at 115 VAC, full load. Earth leakage Less than 160 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Block-diagram frequency 100 kHz. Protection Short circuit / overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage CH1 threshold: 5.7–6.8 V. Output shuts down; re-power on to recover. Overtemperature, TSW1 Output shuts down and automatically recovers after temperature decreases. Overtemperature, TSW2 Output shuts down; re-power on to recover. Protection thresholds are not an overload operating allowance. The two thermal-protection responses are distinct. Status and Model Functions Power Good / Power Fail Catalogue timing: 10 ms < PG < 500 ms; PF >1 ms. The status connector is CN3, pin 1 PG and pin 2 GND. No separate PF connector pin is assigned. Indicator An LED power indicator is marked on the PCB mechanical drawing. Model-function boundary 5Vsb, PS-ON and the controlled-off consumption claim are specified for G models and are not assigned to this basic RPT model. Derating and Environment Ambient range −20 to +70°C, subject to the cooling-mode curve. Horizontal-mounting temperature curve On the common catalogue percentage scale, the enclosed convection curve is 95% through 40°C and falls to 38% at 60°C; with 20.5 CFM it is 95% through 50°C and falls to 38% at 70°C. Use the enclosed model’s reduced current and combined-power ratings; the graph is not an alternative higher wattage specification. Input-voltage curve, 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude Up to 3000 m. Above 2000 m, reduce allowable ambient temperature by 3.5°C per 1000 m for fanless operation, or 5°C per 1000 m for fan-cooled operation. Combine the temperature, input-voltage, altitude and loading limits. Natural-convection curves end at 60°C; the 70°C endpoint requires the stated forced-air condition. Do not infer a pulse or peak-power allowance. Mechanical Installation and Cooling Size, L × W × H 130 × 86 × 43 mm. Drawing PDF page 24; dimensions in millimetres. Enclosure Optional -C enclosure, Case No.247A. Bottom mounting Four M3 positions on a 120 × 50 mm pattern; 5 mm and 18.3 mm edge references. Side mounting The side drawing marks four M3 L=4 positions and separate 120 mm / 110.5 mm dimensions; follow the complete drawing for their locations. Screw penetration and torque The installation table specifies M3, maximum penetration 2 mm for both listed hole groups, and 4–6 kgf-cm torque. Select screw length for the actual mounting thickness; do not treat the side-view L=4 marking as permission to exceed the installation limit. External airflow placement 20.5 CFM external fan, 5 cm from the enclosure, blowing in the shown direction; fan centre is referenced 65 mm from the output-side edge. Grounding and heat sinks M1 and M2 are safety-ground points and both must be grounded. HS1, HS2 and HS3 must not be shorted. Adjustment and fuse references SVR1 is the adjustment reference; the drawing marks FS1 and FS2, without assigning a replacement fuse ordering code. The shown fan establishes the forced-air test/installation condition; a fan, mounting screws or loose mating connectors are not stated as included. Keep the indicated airflow path and clearances open. No separate mounting-kit ordering code is given. Connections and Mating Components AC input CN1 JST B3P-VH or equivalent: pin 1 AC/L, pin 2 no pin, pin 3 AC/N. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Three-output connector CN2 JST B8P-VH or equivalent: pins 1–4 COM, pins 5–6 CH1, pin 7 CH2, pin 8 CH3. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Power Good connector CN3 JST B2B-XH or equivalent: pin 1 PG, pin 2 GND. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. VHR, XHP are the abbreviated references printed in this catalogue. Select the exact position count and complete manufacturer ordering suffix for the required mating part; these pages do not provide every suffix. Do not substitute another series’ pin assignment. Safety, Isolation and EMC Version-specific approval status The enclosed specification states design reference to IEC60601-1, EAC TP TC004 and TUV BS EN/EN60601-1, with CB/TUV pending in this catalogue revision. Do not treat the PCB approval list, including ANSI/AAMI, as an approval for this -C product. Isolation Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11): conducted Class B and radiated Class B in the Class I configuration with FG. Harmonics: BS EN/EN61000-3-2 Class A; voltage flicker: BS EN/EN61000-3-3. Equipment configuration Use Class I with FG; the -C version is not suitable for a Class II system without FG. Immunity: BS EN/EN55035 and BS EN/EN60601-1-2. ESD (-4-2): level 4, 15 kV air / 8 kV contact. RF field (-4-3): level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT (-4-4): level 3, 2 kV. Surge (-4-5): level 3, 2 kV line–FG / 1 kV line–line. Conducted susceptibility (-4-6): level 3, 10 V. Magnetic field (-4-8): level 4, 30 A/m. Dips/interruption (-4-11): 100% dip for 1 period, 30% dip for 25 periods, 100% interruption for 250 periods. The catalogue EMC setup uses a 360 × 360 × 1 mm metal plate. This power supply is an installation component; re-confirm compliance in the finished equipment. Weight, Reliability and Catalogue Single-unit catalogue weight 490 g (0.49 kg), explicitly printed per unit in PACKING; a catalogue packing reference, not a measured net or shipping-parcel weight. Packing 24 pieces / 12.8 kg / 0.77 CUFT. MTBF, minimum estimates 1719.1 thousand hours, Telcordia SR-332 (Bellcore); 175.1 thousand hours, MIL-HDBK-217F at 25°C. Lifetime statement The series feature list states a lifetime greater than 85,000 hours, without test conditions on these pages; it is not a guaranteed service life for every installation. Warranty Three-year manufacturer warranty, subject to applicable terms. Catalogue RPT-160-SPEC, 2024-04-15; combined PDF pages 19–25.

    $161.16

  • RPTG-160C-C

    MEAN WELL RPT-160 series: Enclosed Triple Output Medical AC/DC Power Supply - RPTG-160C-C

    MEAN WELL RPTG-160C-C is an enclosed casing triple-output AC/DC power supply with 5 V / 15 V / −15 V rails. The catalogue combined ratings are 135.8 W with 20.5 CFM airflow and 94.4 W with natural convection, subject to the individual channel limits and standby-power notes below. This G model adds a 5 V standby rail and PS-ON control. Product Datasheet Download MEAN WELL RPT-160 Datasheet (PDF) The RPT-160 section is on PDF pages 19, 20, 21, 22, 23, 24, 25. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPTG-160C-C. Configuration Optional enclosed type. G: green model with standby and PS-ON. Output code C: CH1 / CH2 / CH3 = 5 V / 15 V / −15 V. System grounding Class I with protective ground (FG). Both M1 and M2 safety-ground points must be grounded. Typical applications Oral irrigators, hemodialysis equipment, medical monitors, sleep-apnea devices and pumps. BF application requires appropriate complete-system consideration. Isolation, leakage, protective grounding and final-equipment EMC must be assessed for the actual installation. The optional enclosed version has a different approval status from the PCB version; see the safety section. Combined Output and Test Conditions Combined rated power, 20.5 CFM 135.8 W, as printed in the model table. Combined rated power, convection 94.4 W, as printed in the model table. CH1 adjustment 5–5.5 V using SVR1; no independent CH2/CH3 adjustment range is stated. Efficiency, typical 83%. The rated-power footnotes include 5Vsb at 0.8 A with 20.5 CFM, or 0.6 A with natural convection. Standby is already included in these totals; do not add it again. Keep every channel within its stated minimum and maximum load, and meet the applicable combined-power limit, cooling and derating conditions simultaneously. The series name is not a per-channel wattage rating. Unless stated otherwise, specifications are measured at 230 VAC, rated load and 25°C. Ripple/noise is measured over 20 MHz with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Tolerance includes set-up tolerance, line regulation and load regulation. CH1 Output Nominal voltage 5 V relative to COM. Rated current, 20.5 CFM 13.3 A. Load-current range, 20.5 CFM 0.6–13.3 A. Load-current range, convection 0.6–8.5 A. Minimum load 0.6 A in both stated cooling modes. Ripple and noise, maximum 60 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±2.0%. CH2 Output Nominal voltage 15 V relative to COM. Rated current, 20.5 CFM 3.4 A. Load-current range, 20.5 CFM 0.1–3.4 A. Load-current range, convection 0.1–2.5 A. Minimum load 0.1 A in both stated cooling modes. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±4.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage −15 V relative to COM. Rated current, 20.5 CFM 0.95 A. Load-current range, 20.5 CFM 0.1–0.95 A. Load-current range, convection 0.1–0.76 A. Minimum load 0.1 A in both stated cooling modes. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±8.0%. Line regulation ±1.0%. Load regulation ±8.0%. Input, Timing and Leakage Input 90–264 VAC or 127–370 VDC; apply low-input derating. AC frequency 47–63 Hz. Power-factor correction Built-in active PFC; at full load PF >0.93 at 230 VAC and >0.98 at 115 VAC. AC current, typical 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise 1800 ms / 30 ms at 230 VAC; 3500 ms / 30 ms at 115 VAC, full load. Hold-up, typical 30 ms at 230 VAC; 20 ms at 115 VAC, full load. Earth leakage Less than 160 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Block-diagram frequency 100 kHz. Protection Short circuit / overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage CH1 threshold: 5.7–6.8 V. Output shuts down; re-power on to recover. Overtemperature, TSW1 Output shuts down and automatically recovers after temperature decreases. Overtemperature, TSW2 Output shuts down; re-power on to recover. Protection thresholds are not an overload operating allowance. The two thermal-protection responses are distinct. Status and Standby Control Power Good / Power Fail Catalogue timing: 10 ms < PG < 500 ms; PF >1 ms. The status connector is CN3, pin 1 PG and pin 2 GND. No separate PF connector pin is assigned. Indicator An LED power indicator is marked on the PCB mechanical drawing. 5 V standby 5 V at up to 0.6 A without a fan, or 0.8 A with 20.5 CFM; tolerance ±2%, ripple/noise 50 mVp-p maximum. PS-ON High, 2–5 V: power on. Low, 0–0.5 V: power off. CN901 pin 1 is PS/ON; pins 2 and 4 are GND. The illustrated transistor interface is marked 5 mA maximum. Low-power condition Less than 0.75 W using PS-ON control. This is a G-model controlled-off condition, not an unconditional output-on no-load rating. Derating and Environment Ambient range −20 to +70°C, subject to the cooling-mode curve. Horizontal-mounting temperature curve On the common catalogue percentage scale, the enclosed convection curve is 95% through 40°C and falls to 38% at 60°C; with 20.5 CFM it is 95% through 50°C and falls to 38% at 70°C. Use the enclosed model’s reduced current and combined-power ratings; the graph is not an alternative higher wattage specification. Input-voltage curve, 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude Up to 3000 m. Above 2000 m, reduce allowable ambient temperature by 3.5°C per 1000 m for fanless operation, or 5°C per 1000 m for fan-cooled operation. Combine the temperature, input-voltage, altitude and loading limits. Natural-convection curves end at 60°C; the 70°C endpoint requires the stated forced-air condition. Do not infer a pulse or peak-power allowance. Mechanical Installation and Cooling Size, L × W × H 130 × 86 × 43 mm. Drawing PDF page 24; dimensions in millimetres. Enclosure Optional -C enclosure, Case No.247A. Bottom mounting Four M3 positions on a 120 × 50 mm pattern; 5 mm and 18.3 mm edge references. Side mounting The side drawing marks four M3 L=4 positions and separate 120 mm / 110.5 mm dimensions; follow the complete drawing for their locations. Screw penetration and torque The installation table specifies M3, maximum penetration 2 mm for both listed hole groups, and 4–6 kgf-cm torque. Select screw length for the actual mounting thickness; do not treat the side-view L=4 marking as permission to exceed the installation limit. External airflow placement 20.5 CFM external fan, 5 cm from the enclosure, blowing in the shown direction; fan centre is referenced 65 mm from the output-side edge. Grounding and heat sinks M1 and M2 are safety-ground points and both must be grounded. HS1, HS2 and HS3 must not be shorted. Adjustment and fuse references SVR1 is the adjustment reference; the drawing marks FS1 and FS2, without assigning a replacement fuse ordering code. The shown fan establishes the forced-air test/installation condition; a fan, mounting screws or loose mating connectors are not stated as included. Keep the indicated airflow path and clearances open. No separate mounting-kit ordering code is given. Connections and Mating Components AC input CN1 JST B3P-VH or equivalent: pin 1 AC/L, pin 2 no pin, pin 3 AC/N. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Three-output connector CN2 JST B8P-VH or equivalent: pins 1–4 COM, pins 5–6 CH1, pin 7 CH2, pin 8 CH3. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Power Good connector CN3 JST B2B-XH or equivalent: pin 1 PG, pin 2 GND. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. Standby/control CN901 Catalogue connector reference JST B-XH or equivalent: pin 1 PS/ON, pins 2 and 4 GND, pin 3 5VSB. Mating housing JST XHP or equivalent; terminal reference JST SXH-001T or equivalent. VHR, XHP, B-XH and SXH-001T are the abbreviated references printed in this catalogue. Select the exact position count and complete manufacturer ordering suffix for the required mating part; these pages do not provide every suffix. Do not substitute another series’ pin assignment. Safety, Isolation and EMC Version-specific approval status The enclosed specification states design reference to IEC60601-1, EAC TP TC004 and TUV BS EN/EN60601-1, with CB/TUV pending in this catalogue revision. Do not treat the PCB approval list, including ANSI/AAMI, as an approval for this -C product. Isolation Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11): conducted Class B and radiated Class B in the Class I configuration with FG. Harmonics: BS EN/EN61000-3-2 Class A; voltage flicker: BS EN/EN61000-3-3. Equipment configuration Use Class I with FG; the -C version is not suitable for a Class II system without FG. Immunity: BS EN/EN55035 and BS EN/EN60601-1-2. ESD (-4-2): level 4, 15 kV air / 8 kV contact. RF field (-4-3): level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT (-4-4): level 3, 2 kV. Surge (-4-5): level 3, 2 kV line–FG / 1 kV line–line. Conducted susceptibility (-4-6): level 3, 10 V. Magnetic field (-4-8): level 4, 30 A/m. Dips/interruption (-4-11): 100% dip for 1 period, 30% dip for 25 periods, 100% interruption for 250 periods. The catalogue EMC setup uses a 360 × 360 × 1 mm metal plate. This power supply is an installation component; re-confirm compliance in the finished equipment. Weight, Reliability and Catalogue Single-unit catalogue weight 490 g (0.49 kg), explicitly printed per unit in PACKING; a catalogue packing reference, not a measured net or shipping-parcel weight. Packing 24 pieces / 12.8 kg / 0.77 CUFT. MTBF, minimum estimates 1719.1 thousand hours, Telcordia SR-332 (Bellcore); 175.1 thousand hours, MIL-HDBK-217F at 25°C. Lifetime statement The series feature list states a lifetime greater than 85,000 hours, without test conditions on these pages; it is not a guaranteed service life for every installation. Warranty Three-year manufacturer warranty, subject to applicable terms. Catalogue RPT-160-SPEC, 2024-04-15; combined PDF pages 19–25.

    $178.41

  • RPTG-160C-C

    MEAN WELL RPT-160 series: Enclosed Triple Output Medical AC/DC Power Supply - RPTG-160C-C

    MEAN WELL RPTG-160C-C is an enclosed casing triple-output AC/DC power supply with 5 V / 15 V / −15 V rails. The catalogue combined ratings are 135.8 W with 20.5 CFM airflow and 94.4 W with natural convection, subject to the individual channel limits and standby-power notes below. This G model adds a 5 V standby rail and PS-ON control. Product Datasheet Download MEAN WELL RPT-160 Datasheet (PDF) The RPT-160 section is on PDF pages 19, 20, 21, 22, 23, 24, 25. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPTG-160C-C. Configuration Optional enclosed type. G: green model with standby and PS-ON. Output code C: CH1 / CH2 / CH3 = 5 V / 15 V / −15 V. System grounding Class I with protective ground (FG). Both M1 and M2 safety-ground points must be grounded. Typical applications Oral irrigators, hemodialysis equipment, medical monitors, sleep-apnea devices and pumps. BF application requires appropriate complete-system consideration. Isolation, leakage, protective grounding and final-equipment EMC must be assessed for the actual installation. The optional enclosed version has a different approval status from the PCB version; see the safety section. Combined Output and Test Conditions Combined rated power, 20.5 CFM 135.8 W, as printed in the model table. Combined rated power, convection 94.4 W, as printed in the model table. CH1 adjustment 5–5.5 V using SVR1; no independent CH2/CH3 adjustment range is stated. Efficiency, typical 83%. The rated-power footnotes include 5Vsb at 0.8 A with 20.5 CFM, or 0.6 A with natural convection. Standby is already included in these totals; do not add it again. Keep every channel within its stated minimum and maximum load, and meet the applicable combined-power limit, cooling and derating conditions simultaneously. The series name is not a per-channel wattage rating. Unless stated otherwise, specifications are measured at 230 VAC, rated load and 25°C. Ripple/noise is measured over 20 MHz with a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Tolerance includes set-up tolerance, line regulation and load regulation. CH1 Output Nominal voltage 5 V relative to COM. Rated current, 20.5 CFM 13.3 A. Load-current range, 20.5 CFM 0.6–13.3 A. Load-current range, convection 0.6–8.5 A. Minimum load 0.6 A in both stated cooling modes. Ripple and noise, maximum 60 mVp-p. Voltage tolerance ±2.0%. Line regulation ±0.5%. Load regulation ±2.0%. CH2 Output Nominal voltage 15 V relative to COM. Rated current, 20.5 CFM 3.4 A. Load-current range, 20.5 CFM 0.1–3.4 A. Load-current range, convection 0.1–2.5 A. Minimum load 0.1 A in both stated cooling modes. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±4.0%. Line regulation ±1.0%. Load regulation ±3.0%. CH3 Output Nominal voltage −15 V relative to COM. Rated current, 20.5 CFM 0.95 A. Load-current range, 20.5 CFM 0.1–0.95 A. Load-current range, convection 0.1–0.76 A. Minimum load 0.1 A in both stated cooling modes. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±8.0%. Line regulation ±1.0%. Load regulation ±8.0%. Input, Timing and Leakage Input 90–264 VAC or 127–370 VDC; apply low-input derating. AC frequency 47–63 Hz. Power-factor correction Built-in active PFC; at full load PF >0.93 at 230 VAC and >0.98 at 115 VAC. AC current, typical 1.8 A at 115 VAC; 0.9 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up / rise 1800 ms / 30 ms at 230 VAC; 3500 ms / 30 ms at 115 VAC, full load. Hold-up, typical 30 ms at 230 VAC; 20 ms at 115 VAC, full load. Earth leakage Less than 160 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Block-diagram frequency 100 kHz. Protection Short circuit / overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage CH1 threshold: 5.7–6.8 V. Output shuts down; re-power on to recover. Overtemperature, TSW1 Output shuts down and automatically recovers after temperature decreases. Overtemperature, TSW2 Output shuts down; re-power on to recover. Protection thresholds are not an overload operating allowance. The two thermal-protection responses are distinct. Status and Standby Control Power Good / Power Fail Catalogue timing: 10 ms < PG < 500 ms; PF >1 ms. The status connector is CN3, pin 1 PG and pin 2 GND. No separate PF connector pin is assigned. Indicator An LED power indicator is marked on the PCB mechanical drawing. 5 V standby 5 V at up to 0.6 A without a fan, or 0.8 A with 20.5 CFM; tolerance ±2%, ripple/noise 50 mVp-p maximum. PS-ON High, 2–5 V: power on. Low, 0–0.5 V: power off. CN901 pin 1 is PS/ON; pins 2 and 4 are GND. The illustrated transistor interface is marked 5 mA maximum. Low-power condition Less than 0.75 W using PS-ON control. This is a G-model controlled-off condition, not an unconditional output-on no-load rating. Derating and Environment Ambient range −20 to +70°C, subject to the cooling-mode curve. Horizontal-mounting temperature curve On the common catalogue percentage scale, the enclosed convection curve is 95% through 40°C and falls to 38% at 60°C; with 20.5 CFM it is 95% through 50°C and falls to 38% at 70°C. Use the enclosed model’s reduced current and combined-power ratings; the graph is not an alternative higher wattage specification. Input-voltage curve, 60 Hz 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude Up to 3000 m. Above 2000 m, reduce allowable ambient temperature by 3.5°C per 1000 m for fanless operation, or 5°C per 1000 m for fan-cooled operation. Combine the temperature, input-voltage, altitude and loading limits. Natural-convection curves end at 60°C; the 70°C endpoint requires the stated forced-air condition. Do not infer a pulse or peak-power allowance. Mechanical Installation and Cooling Size, L × W × H 130 × 86 × 43 mm. Drawing PDF page 24; dimensions in millimetres. Enclosure Optional -C enclosure, Case No.247A. Bottom mounting Four M3 positions on a 120 × 50 mm pattern; 5 mm and 18.3 mm edge references. Side mounting The side drawing marks four M3 L=4 positions and separate 120 mm / 110.5 mm dimensions; follow the complete drawing for their locations. Screw penetration and torque The installation table specifies M3, maximum penetration 2 mm for both listed hole groups, and 4–6 kgf-cm torque. Select screw length for the actual mounting thickness; do not treat the side-view L=4 marking as permission to exceed the installation limit. External airflow placement 20.5 CFM external fan, 5 cm from the enclosure, blowing in the shown direction; fan centre is referenced 65 mm from the output-side edge. Grounding and heat sinks M1 and M2 are safety-ground points and both must be grounded. HS1, HS2 and HS3 must not be shorted. Adjustment and fuse references SVR1 is the adjustment reference; the drawing marks FS1 and FS2, without assigning a replacement fuse ordering code. The shown fan establishes the forced-air test/installation condition; a fan, mounting screws or loose mating connectors are not stated as included. Keep the indicated airflow path and clearances open. No separate mounting-kit ordering code is given. Connections and Mating Components AC input CN1 JST B3P-VH or equivalent: pin 1 AC/L, pin 2 no pin, pin 3 AC/N. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Three-output connector CN2 JST B8P-VH or equivalent: pins 1–4 COM, pins 5–6 CH1, pin 7 CH2, pin 8 CH3. Mating housing JST VHR or equivalent; terminal JST SVH-21T-P1.1 or equivalent. Power Good connector CN3 JST B2B-XH or equivalent: pin 1 PG, pin 2 GND. Mating housing JST XHP or equivalent; terminal JST SXH-001T-P0.6 or equivalent. Standby/control CN901 Catalogue connector reference JST B-XH or equivalent: pin 1 PS/ON, pins 2 and 4 GND, pin 3 5VSB. Mating housing JST XHP or equivalent; terminal reference JST SXH-001T or equivalent. VHR, XHP, B-XH and SXH-001T are the abbreviated references printed in this catalogue. Select the exact position count and complete manufacturer ordering suffix for the required mating part; these pages do not provide every suffix. Do not substitute another series’ pin assignment. Safety, Isolation and EMC Version-specific approval status The enclosed specification states design reference to IEC60601-1, EAC TP TC004 and TUV BS EN/EN60601-1, with CB/TUV pending in this catalogue revision. Do not treat the PCB approval list, including ANSI/AAMI, as an approval for this -C product. Isolation Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance Input–output, input–FG and output–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11): conducted Class B and radiated Class B in the Class I configuration with FG. Harmonics: BS EN/EN61000-3-2 Class A; voltage flicker: BS EN/EN61000-3-3. Equipment configuration Use Class I with FG; the -C version is not suitable for a Class II system without FG. Immunity: BS EN/EN55035 and BS EN/EN60601-1-2. ESD (-4-2): level 4, 15 kV air / 8 kV contact. RF field (-4-3): level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT (-4-4): level 3, 2 kV. Surge (-4-5): level 3, 2 kV line–FG / 1 kV line–line. Conducted susceptibility (-4-6): level 3, 10 V. Magnetic field (-4-8): level 4, 30 A/m. Dips/interruption (-4-11): 100% dip for 1 period, 30% dip for 25 periods, 100% interruption for 250 periods. The catalogue EMC setup uses a 360 × 360 × 1 mm metal plate. This power supply is an installation component; re-confirm compliance in the finished equipment. Weight, Reliability and Catalogue Single-unit catalogue weight 490 g (0.49 kg), explicitly printed per unit in PACKING; a catalogue packing reference, not a measured net or shipping-parcel weight. Packing 24 pieces / 12.8 kg / 0.77 CUFT. MTBF, minimum estimates 1719.1 thousand hours, Telcordia SR-332 (Bellcore); 175.1 thousand hours, MIL-HDBK-217F at 25°C. Lifetime statement The series feature list states a lifetime greater than 85,000 hours, without test conditions on these pages; it is not a guaranteed service life for every installation. Warranty Three-year manufacturer warranty, subject to applicable terms. Catalogue RPT-160-SPEC, 2024-04-15; combined PDF pages 19–25.

    $178.41


You have seen 24 out of 102 products