MEAN WELL RPS Series Reliable Green Medical Power Supply (30W~160W)

  • Product Features
  • General Specifications
  • Output Models Overview
  • Product Ordering Code

Product Features

  • Medical safety approved (2 x MOPP primary to secondary) according to IEC/EN60601-1 and ANSI/AAMI ES60601-1.
  • Suitable for BF (Body Floating) applications with appropriate system considerations.
  • Ultra-low leakage current (ranging from <80µA to <200µA depending on the model), ensuring patient safety.
  • Universal AC input range (80~264VAC or 90~264VAC).
  • Extremely high efficiency (up to 94%) and ultra-low no-load power consumption.
  • Compact PCB design (e.g., 3"x2", 4"x2" footprints).
  • Higher wattage models (120W, 160W) feature built-in active PFC function, fan supply, and support both natural convection and forced air cooling.
  • Comprehensive protection features: Short circuit, Overload, Over voltage, and Over temperature.

General Specifications

Item Specification Description
Input Voltage Range 80 ~ 264VAC / 90 ~ 264VAC (Varies by model)
Input Frequency 47 ~ 63Hz
Isolation Level I/P-O/P: 2xMOPP, I/P-FG: 1xMOPP, O/P-FG: 1xMOPP (or 1.5KVAC)
Withstand Voltage I/P-O/P: 4KVAC, I/P-FG: 2KVAC, O/P-FG: 1.5KVAC
Leakage Current Earth leakage current <150µA; Touch current <80µA ~ <100µA (at 264VAC)
Working Temperature -30°C ~ +70°C (Refer to specific model's derating curve)
Protections Overload (Hiccup mode, auto-recovery), Over Voltage (Shut down, re-power on), Over Temperature (on higher wattage models)
Safety Standards IEC 60601-1, TUV BS EN/EN 60601-1, ANSI/AAMI ES60601-1, EAC TP TC 004
EMC Emission BS EN/EN55011 (CISPR11) Class B, EN61000-3-2 Class A

Output Models Overview

Series Rated Power (Convection / Forced Air) Available Output Voltages (DC) Key Features / Package
RPS-30 30W 3.3V, 5V, 7.5V, 12V, 15V, 24V, 48V 3"x2" PCB, Peak load 10s
RPS-45 45W 3.3V, 5V, 7.5V, 12V, 15V, 24V, 48V 3"x2" PCB, Peak load 10s
RPS-60 60W 3.3V, 5V, 12V, 15V, 24V, 48V 4"x2" PCB, Peak load 10s
RPS-65 65W 3.3V, 5V, 7.5V, 12V, 15V, 24V, 48V 3"x2" PCB, Peak load 10s
RPS-75 75W 3.3V, 5V, 12V, 15V, 24V, 36V, 48V 5"x3" PCB
RPS-120 84W (Convection) / 120W (10CFM) 12V, 15V, 24V, 27V, 48V 4"x2" PCB, Active PFC, 12V Fan supply
RPS-120S 114W-120W (Convection) 12V, 15V, 24V, 27V, 48V 3"x2" High Power Density, Peak 150W (10s)
RPS-160 103W-113W (Conv.) / 155W-161W (20.5CFM) 5V, 12V, 15V, 24V, 48V 5"x3" PCB, Active PFC, 5Vsb, PS-ON signal
Note: Peak load capabilities (e.g., 10 seconds) allow for starting high-surge medical devices. When utilizing forced air (CFM) ratings, an external cooling fan is required.

Product Ordering Code

No. Item Code Description
1 Series Name RPS MEAN WELL Reliable Green Medical Power Supply
2 Rated Power 30 ~ 160 30W, 45W, 60W, 65W, 75W, 120W, 160W
3 Size Indicator Blank Standard Size
S Compact Size (e.g., RPS-120S for 3"x2" footprint)
4 Output Voltage 3.3 ~ 48 3.3V, 5V, 7.5V, 12V, 15V, 24V, 27V, 36V, 48V (See Overview for availability)
5 Special Function Suffix Blank Standard Model
-G Equipped with 5V standby (5Vsb) and PS-ON function (Available on RPS-160)
  • RPSG-160-48

    MEAN WELL RPS-160 series: Open-Frame Medical AC/DC Power Supply - RPSG-160-48

    MEAN WELL RPSG-160-48 is a 5 × 3-inch open-frame medical AC/DC power supply with a 48 V main output. The main-output current is 2.3 A with natural convection and 3.25 A with the specified 20.5 CFM airflow. G version with 5 V standby output and PS-ON control. It is intended for Class I equipment with protective grounding; BF applications require appropriate system consideration. Product Datasheet Download MEAN WELL RPS-160 Datasheet (PDF) The RPS-160 section is on PDF pages 37, 38, 39, 40. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPSG-160-48 Configuration G version with 5 V standby output and PS-ON control. Board format 127 × 76.2 mm (5 × 3 inches); open-frame PCB construction. Intended applications Oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices and pump equipment. Medical component approvals and isolation ratings do not certify the completed device. The equipment design must satisfy the applicable patient-protection, grounding, leakage-current and EMC requirements. Output Ratings and Cooling Conditions Nominal main output 48 V. Convection main-output current 0–2.3 A. Forced-air main-output current 0–3.25 A with at least 20.5 CFM as shown in the installation drawing. Main-output power at nominal voltage 110.4 W with convection and 156 W with 20.5 CFM, calculated from nominal voltage × the respective main-output current limit. Catalogue family combined-power entries 113.4 W with convection; 161 W with 20.5 CFM. The table footnotes include 5 V standby at 0.6 A and 0.8 A respectively. Voltage adjustment 43.2–52.8 V for the main output. Ripple and noise, maximum 150 mVp-p. Voltage tolerance ±2.0%; includes set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.0%. Efficiency, typical 88%. Use each rail’s voltage and current limit together with the cooling-mode total-power limit. The combined-power table is not a main-output-only rating and does not override any individual rail current limit. The standby rail is included in the total-power budget. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Input, Timing and Leakage Input range 90–264 VAC or 127–370 VDC; observe the low-input derating curve. Input frequency 47–63 Hz. AC current, typical 2 A at 115 VAC; 1.1 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up and rise time 1800 ms set-up at 230 VAC; 3500 ms at 115 VAC; 30 ms rise at either input, at full load. Hold-up time, typical 25 ms at 230 VAC; 20 ms at 115 VAC, at full load. Earth leakage current Less than 200 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Power-factor correction Built-in PFC; typical PF >0.93 at 230 VAC and >0.98 at 115 VAC, full load. Switching-frequency reference 70 kHz for the 12–48 V models. Protection Short circuit and overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage threshold 55.2–64.8 V. Overvoltage response Output shuts down; re-power to recover. Overtemperature response TSW1 shuts down the output and automatically recovers after temperature falls. TSW2 shuts down the output and requires re-powering to recover. Protection trip thresholds do not increase the usable output rating. Control and Monitoring Power Good / Power Fail timing 10 ms < PG < 500 ms; PF >1 ms. CN3 pin 1 is labelled PG and pin 2 GND; the pages do not assign a separate PF pin or provide an additional signal-current rating. Remote sense The catalogue limits remote sense to the 5–15 V models; it is not specified for this 48 V output. Status indication An LED is shown on the mechanical drawing. 5 V standby output 5 V at up to 0.6 A with convection or 0.8 A with 20.5 CFM; tolerance ±2%, ripple/noise 50 mVp-p maximum. PS-ON control G model only: high (2–5 V) turns the main output on; low (0–0.5 V) turns it off. The interface sketch marks 5 mA maximum. Standby and control connector CN901 pin 1 PS/ON; pins 2 and 4 GND; pin 3 5VSB. Low-power condition Input consumption below 0.5 W is specified using PS-ON control on the G model; it is not a blanket operating no-load figure for all versions. Temperature, Input Derating and Environment Working temperature −20 to +70°C with the applicable cooling and load restrictions. Horizontal-mounting temperature curve Natural convection: 100% of the convection rating through 40°C, falling to 40% at 60°C. With the specified fan airflow: 100% of the forced-air rating through 50°C, falling to 40% at 70°C. The no-fan curve ends at 60°C; do not extend it to 70°C. Input-voltage curve At 60 Hz, the graph permits 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes each along X, Y and Z. Operating altitude Up to 3,000 m. Above 2,000 m, reduce permitted ambient temperature by 3.5°C per additional 1,000 m for fanless operation, or 5°C per additional 1,000 m with a fan. Combine temperature, input-voltage and airflow restrictions. Do not interpret the maximum ambient temperature as a full-power rating. Installation and Mechanical Details Dimensions, L × W × H 127 × 76.2 × 34.6 mm. Mounting holes Four holes, diameter 3.5 mm; centre spacing 117 × 66.2 mm. Drawing references Edge-to-hole offsets are 5 mm and 5 mm as drawn. General dimensional tolerance ±1 mm; projection below the board 3 mm maximum. Forced-air arrangement At least 20.5 CFM; the drawing shows a fan 5 cm from the board edge, centred at the 63.5 mm longitudinal position, with airflow across the board in the indicated direction. Safety ground and chassis M1 is the safety-ground point. Secure electrical connections between M1, M2 and chassis ground for the specified installation and EMC performance. Heat sinks HS1, HS2 and HS3 must not be shorted together. Follow the complete mechanical drawing and manufacturer installation manual. The catalogue does not specify mounting-screw torque, supplied mounting hardware or a complete fan ordering code. The indicated airflow arrangement is required for the corresponding higher-load rating. Compatible Connectors and Mating Parts AC input CN1 JST B3P-VH or equivalent; pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. DC output CN2 JST B8P-VH or equivalent; pins 1–4 +V, pins 5–8 −V. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Power-Good / sense CN3 JST B4B-XH or equivalent; pin 1 PG, pin 2 GND, pin 3 −S, pin 4 +S. Mating housing is printed as JST XHP; terminal JST SXH-001T-P0.6 or equivalent. Use sense pins only on the 5–15 V models. Standby CN901 The catalogue prints JST B-XH or equivalent, mating housing JST XHP, terminal JST SXH-001T. Pin 1 PS/ON; pins 2 and 4 GND; pin 3 5VSB. The complete printed connector and terminal references above identify the documented interface parts. VHR and XHP are abbreviated housing-family references; B-XH and SXH-001T for CN901 are also incomplete ordering references. Confirm the full housing/contact suffix and circuit count with the connector supplier before ordering. No unprinted suffix or inclusion in the power-supply package is implied. Safety, Isolation and EMC Listed medical approvals IEC60601-1:2005+A1+A2; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Other design reference BS EN/EN60335-1 is listed as a design reference by request, not an unconditional standard configuration approval. Patient-protection isolation Primary to secondary: 2 × MOPP; primary to earth: 1 × MOPP; secondary to earth: 1 × MOPP. System configuration Class I with FG. Suitable for BF applications with appropriate system consideration. Withstand voltage Input to output 4 kVAC; input to FG 2 kVAC; output to FG 1.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11), conducted and radiated Class B for Class I configuration. Harmonic current: BS EN/EN61000-3-2 Class A; flicker: BS EN/EN61000-3-3. Immunity framework BS EN/EN55035 and BS EN/EN60601-1-2. ESD BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF immunity BS EN/EN61000-4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9, 9–28 V/m at 385 MHz–5.78 GHz. EFT / burst and surge BS EN/EN61000-4-4: Level 3, 2 kV. BS EN/EN61000-4-5: Level 4, 4 kV line-to-FG and 2 kV line-to-line. Conducted and magnetic immunity BS EN/EN61000-4-6: Level 3, 10 V. BS EN/EN61000-4-8: Level 4, 30 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: 100% dip for 1 period, 30% dip for 25 periods, and 100% interruption for 250 periods. EMC testing used a 360 × 360 mm metal plate, 1 mm thick. This supply is an equipment component; EMC compliance must be confirmed again in the finished equipment. Weight, Reliability and Catalogue Reference Single-unit catalogue weight 330 g, from the explicit 0.33 kg per-unit PACKING entry. This is a catalogue reference, not a measured net or shipping weight. Packing reference 36 pieces / 12.9 kg / 0.96 CUFT. MTBF estimates 2082.3 thousand hours minimum, Telcordia SR-332 (Bellcore); 234.5 thousand hours minimum, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue revision RPS-160-SPEC 2026-02-28; combined PDF pages 37–40. MTBF is a statistical reliability estimate under the stated methods, not a guaranteed service life.

    $135.04

  • RPSG-160-24

    MEAN WELL RPS-160 series: Open-Frame Medical AC/DC Power Supply - RPSG-160-24

    MEAN WELL RPSG-160-24 is a 5 × 3-inch open-frame medical AC/DC power supply with a 24 V main output. The main-output current is 4.6 A with natural convection and 6.5 A with the specified 20.5 CFM airflow. G version with 5 V standby output and PS-ON control. It is intended for Class I equipment with protective grounding; BF applications require appropriate system consideration. Product Datasheet Download MEAN WELL RPS-160 Datasheet (PDF) The RPS-160 section is on PDF pages 37, 38, 39, 40. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPSG-160-24 Configuration G version with 5 V standby output and PS-ON control. Board format 127 × 76.2 mm (5 × 3 inches); open-frame PCB construction. Intended applications Oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices and pump equipment. Medical component approvals and isolation ratings do not certify the completed device. The equipment design must satisfy the applicable patient-protection, grounding, leakage-current and EMC requirements. Output Ratings and Cooling Conditions Nominal main output 24 V. Convection main-output current 0–4.6 A. Forced-air main-output current 0–6.5 A with at least 20.5 CFM as shown in the installation drawing. Main-output power at nominal voltage 110.4 W with convection and 156 W with 20.5 CFM, calculated from nominal voltage × the respective main-output current limit. Catalogue family combined-power entries 113.4 W with convection; 161 W with 20.5 CFM. The table footnotes include 5 V standby at 0.6 A and 0.8 A respectively. Voltage adjustment 22–27 V for the main output. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±2.0%; includes set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.0%. Efficiency, typical 87%. Use each rail’s voltage and current limit together with the cooling-mode total-power limit. The combined-power table is not a main-output-only rating and does not override any individual rail current limit. The standby rail is included in the total-power budget. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Input, Timing and Leakage Input range 90–264 VAC or 127–370 VDC; observe the low-input derating curve. Input frequency 47–63 Hz. AC current, typical 2 A at 115 VAC; 1.1 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up and rise time 1800 ms set-up at 230 VAC; 3500 ms at 115 VAC; 30 ms rise at either input, at full load. Hold-up time, typical 25 ms at 230 VAC; 20 ms at 115 VAC, at full load. Earth leakage current Less than 200 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Power-factor correction Built-in PFC; typical PF >0.93 at 230 VAC and >0.98 at 115 VAC, full load. Switching-frequency reference 70 kHz for the 12–48 V models. Protection Short circuit and overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage threshold 27.6–32.4 V. Overvoltage response Output shuts down; re-power to recover. Overtemperature response TSW1 shuts down the output and automatically recovers after temperature falls. TSW2 shuts down the output and requires re-powering to recover. Protection trip thresholds do not increase the usable output rating. Control and Monitoring Power Good / Power Fail timing 10 ms < PG < 500 ms; PF >1 ms. CN3 pin 1 is labelled PG and pin 2 GND; the pages do not assign a separate PF pin or provide an additional signal-current rating. Remote sense The catalogue limits remote sense to the 5–15 V models; it is not specified for this 24 V output. Status indication An LED is shown on the mechanical drawing. 5 V standby output 5 V at up to 0.6 A with convection or 0.8 A with 20.5 CFM; tolerance ±2%, ripple/noise 50 mVp-p maximum. PS-ON control G model only: high (2–5 V) turns the main output on; low (0–0.5 V) turns it off. The interface sketch marks 5 mA maximum. Standby and control connector CN901 pin 1 PS/ON; pins 2 and 4 GND; pin 3 5VSB. Low-power condition Input consumption below 0.5 W is specified using PS-ON control on the G model; it is not a blanket operating no-load figure for all versions. Temperature, Input Derating and Environment Working temperature −20 to +70°C with the applicable cooling and load restrictions. Horizontal-mounting temperature curve Natural convection: 100% of the convection rating through 40°C, falling to 40% at 60°C. With the specified fan airflow: 100% of the forced-air rating through 50°C, falling to 40% at 70°C. The no-fan curve ends at 60°C; do not extend it to 70°C. Input-voltage curve At 60 Hz, the graph permits 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes each along X, Y and Z. Operating altitude Up to 3,000 m. Above 2,000 m, reduce permitted ambient temperature by 3.5°C per additional 1,000 m for fanless operation, or 5°C per additional 1,000 m with a fan. Combine temperature, input-voltage and airflow restrictions. Do not interpret the maximum ambient temperature as a full-power rating. Installation and Mechanical Details Dimensions, L × W × H 127 × 76.2 × 34.6 mm. Mounting holes Four holes, diameter 3.5 mm; centre spacing 117 × 66.2 mm. Drawing references Edge-to-hole offsets are 5 mm and 5 mm as drawn. General dimensional tolerance ±1 mm; projection below the board 3 mm maximum. Forced-air arrangement At least 20.5 CFM; the drawing shows a fan 5 cm from the board edge, centred at the 63.5 mm longitudinal position, with airflow across the board in the indicated direction. Safety ground and chassis M1 is the safety-ground point. Secure electrical connections between M1, M2 and chassis ground for the specified installation and EMC performance. Heat sinks HS1, HS2 and HS3 must not be shorted together. Follow the complete mechanical drawing and manufacturer installation manual. The catalogue does not specify mounting-screw torque, supplied mounting hardware or a complete fan ordering code. The indicated airflow arrangement is required for the corresponding higher-load rating. Compatible Connectors and Mating Parts AC input CN1 JST B3P-VH or equivalent; pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. DC output CN2 JST B8P-VH or equivalent; pins 1–4 +V, pins 5–8 −V. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Power-Good / sense CN3 JST B4B-XH or equivalent; pin 1 PG, pin 2 GND, pin 3 −S, pin 4 +S. Mating housing is printed as JST XHP; terminal JST SXH-001T-P0.6 or equivalent. Use sense pins only on the 5–15 V models. Standby CN901 The catalogue prints JST B-XH or equivalent, mating housing JST XHP, terminal JST SXH-001T. Pin 1 PS/ON; pins 2 and 4 GND; pin 3 5VSB. The complete printed connector and terminal references above identify the documented interface parts. VHR and XHP are abbreviated housing-family references; B-XH and SXH-001T for CN901 are also incomplete ordering references. Confirm the full housing/contact suffix and circuit count with the connector supplier before ordering. No unprinted suffix or inclusion in the power-supply package is implied. Safety, Isolation and EMC Listed medical approvals IEC60601-1:2005+A1+A2; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Other design reference BS EN/EN60335-1 is listed as a design reference by request, not an unconditional standard configuration approval. Patient-protection isolation Primary to secondary: 2 × MOPP; primary to earth: 1 × MOPP; secondary to earth: 1 × MOPP. System configuration Class I with FG. Suitable for BF applications with appropriate system consideration. Withstand voltage Input to output 4 kVAC; input to FG 2 kVAC; output to FG 1.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11), conducted and radiated Class B for Class I configuration. Harmonic current: BS EN/EN61000-3-2 Class A; flicker: BS EN/EN61000-3-3. Immunity framework BS EN/EN55035 and BS EN/EN60601-1-2. ESD BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF immunity BS EN/EN61000-4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9, 9–28 V/m at 385 MHz–5.78 GHz. EFT / burst and surge BS EN/EN61000-4-4: Level 3, 2 kV. BS EN/EN61000-4-5: Level 4, 4 kV line-to-FG and 2 kV line-to-line. Conducted and magnetic immunity BS EN/EN61000-4-6: Level 3, 10 V. BS EN/EN61000-4-8: Level 4, 30 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: 100% dip for 1 period, 30% dip for 25 periods, and 100% interruption for 250 periods. EMC testing used a 360 × 360 mm metal plate, 1 mm thick. This supply is an equipment component; EMC compliance must be confirmed again in the finished equipment. Weight, Reliability and Catalogue Reference Single-unit catalogue weight 330 g, from the explicit 0.33 kg per-unit PACKING entry. This is a catalogue reference, not a measured net or shipping weight. Packing reference 36 pieces / 12.9 kg / 0.96 CUFT. MTBF estimates 2082.3 thousand hours minimum, Telcordia SR-332 (Bellcore); 234.5 thousand hours minimum, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue revision RPS-160-SPEC 2026-02-28; combined PDF pages 37–40. MTBF is a statistical reliability estimate under the stated methods, not a guaranteed service life.

    $135.04

  • RPSG-160-15

    MEAN WELL RPS-160 series: Open-Frame Medical AC/DC Power Supply - RPSG-160-15

    MEAN WELL RPSG-160-15 is a 5 × 3-inch open-frame medical AC/DC power supply with a 15 V main output. The main-output current is 7.3 A with natural convection and 10.3 A with the specified 20.5 CFM airflow. G version with 5 V standby output and PS-ON control. It is intended for Class I equipment with protective grounding; BF applications require appropriate system consideration. Product Datasheet Download MEAN WELL RPS-160 Datasheet (PDF) The RPS-160 section is on PDF pages 37, 38, 39, 40. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPSG-160-15 Configuration G version with 5 V standby output and PS-ON control. Board format 127 × 76.2 mm (5 × 3 inches); open-frame PCB construction. Intended applications Oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices and pump equipment. Medical component approvals and isolation ratings do not certify the completed device. The equipment design must satisfy the applicable patient-protection, grounding, leakage-current and EMC requirements. Output Ratings and Cooling Conditions Nominal main output 15 V. Convection main-output current 0–7.3 A. Forced-air main-output current 0–10.3 A with at least 20.5 CFM as shown in the installation drawing. Main-output power at nominal voltage 109.5 W with convection and 154.5 W with 20.5 CFM, calculated from nominal voltage × the respective main-output current limit. Catalogue family combined-power entries 112.5 W with convection; 159.5 W with 20.5 CFM. The table footnotes include 5 V standby at 0.6 A and 0.8 A respectively. Voltage adjustment 13.5–16.5 V for the main output. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±3.0%; includes set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.0%. Efficiency, typical 87%. Use each rail’s voltage and current limit together with the cooling-mode total-power limit. The combined-power table is not a main-output-only rating and does not override any individual rail current limit. The standby rail is included in the total-power budget. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Input, Timing and Leakage Input range 90–264 VAC or 127–370 VDC; observe the low-input derating curve. Input frequency 47–63 Hz. AC current, typical 2 A at 115 VAC; 1.1 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up and rise time 1800 ms set-up at 230 VAC; 3500 ms at 115 VAC; 30 ms rise at either input, at full load. Hold-up time, typical 25 ms at 230 VAC; 20 ms at 115 VAC, at full load. Earth leakage current Less than 200 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Power-factor correction Built-in PFC; typical PF >0.93 at 230 VAC and >0.98 at 115 VAC, full load. Switching-frequency reference 70 kHz for the 12–48 V models. Protection Short circuit and overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage threshold 17.2–20.3 V. Overvoltage response Output shuts down; re-power to recover. Overtemperature response TSW1 shuts down the output and automatically recovers after temperature falls. TSW2 shuts down the output and requires re-powering to recover. Protection trip thresholds do not increase the usable output rating. Control and Monitoring Power Good / Power Fail timing 10 ms < PG < 500 ms; PF >1 ms. CN3 pin 1 is labelled PG and pin 2 GND; the pages do not assign a separate PF pin or provide an additional signal-current rating. Remote sense Available for this 15 V model: CN3 pin 3 −S and pin 4 +S. Status indication An LED is shown on the mechanical drawing. 5 V standby output 5 V at up to 0.6 A with convection or 0.8 A with 20.5 CFM; tolerance ±2%, ripple/noise 50 mVp-p maximum. PS-ON control G model only: high (2–5 V) turns the main output on; low (0–0.5 V) turns it off. The interface sketch marks 5 mA maximum. Standby and control connector CN901 pin 1 PS/ON; pins 2 and 4 GND; pin 3 5VSB. Low-power condition Input consumption below 0.5 W is specified using PS-ON control on the G model; it is not a blanket operating no-load figure for all versions. Temperature, Input Derating and Environment Working temperature −20 to +70°C with the applicable cooling and load restrictions. Horizontal-mounting temperature curve Natural convection: 100% of the convection rating through 40°C, falling to 40% at 60°C. With the specified fan airflow: 100% of the forced-air rating through 50°C, falling to 40% at 70°C. The no-fan curve ends at 60°C; do not extend it to 70°C. Input-voltage curve At 60 Hz, the graph permits 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes each along X, Y and Z. Operating altitude Up to 3,000 m. Above 2,000 m, reduce permitted ambient temperature by 3.5°C per additional 1,000 m for fanless operation, or 5°C per additional 1,000 m with a fan. Combine temperature, input-voltage and airflow restrictions. Do not interpret the maximum ambient temperature as a full-power rating. Installation and Mechanical Details Dimensions, L × W × H 127 × 76.2 × 34.6 mm. Mounting holes Four holes, diameter 3.5 mm; centre spacing 117 × 66.2 mm. Drawing references Edge-to-hole offsets are 5 mm and 5 mm as drawn. General dimensional tolerance ±1 mm; projection below the board 3 mm maximum. Forced-air arrangement At least 20.5 CFM; the drawing shows a fan 5 cm from the board edge, centred at the 63.5 mm longitudinal position, with airflow across the board in the indicated direction. Safety ground and chassis M1 is the safety-ground point. Secure electrical connections between M1, M2 and chassis ground for the specified installation and EMC performance. Heat sinks HS1, HS2 and HS3 must not be shorted together. Follow the complete mechanical drawing and manufacturer installation manual. The catalogue does not specify mounting-screw torque, supplied mounting hardware or a complete fan ordering code. The indicated airflow arrangement is required for the corresponding higher-load rating. Compatible Connectors and Mating Parts AC input CN1 JST B3P-VH or equivalent; pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. DC output CN2 JST B8P-VH or equivalent; pins 1–4 +V, pins 5–8 −V. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Power-Good / sense CN3 JST B4B-XH or equivalent; pin 1 PG, pin 2 GND, pin 3 −S, pin 4 +S. Mating housing is printed as JST XHP; terminal JST SXH-001T-P0.6 or equivalent. Sense is applicable to this model. Standby CN901 The catalogue prints JST B-XH or equivalent, mating housing JST XHP, terminal JST SXH-001T. Pin 1 PS/ON; pins 2 and 4 GND; pin 3 5VSB. The complete printed connector and terminal references above identify the documented interface parts. VHR and XHP are abbreviated housing-family references; B-XH and SXH-001T for CN901 are also incomplete ordering references. Confirm the full housing/contact suffix and circuit count with the connector supplier before ordering. No unprinted suffix or inclusion in the power-supply package is implied. Safety, Isolation and EMC Listed medical approvals IEC60601-1:2005+A1+A2; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Other design reference BS EN/EN60335-1 is listed as a design reference by request, not an unconditional standard configuration approval. Patient-protection isolation Primary to secondary: 2 × MOPP; primary to earth: 1 × MOPP; secondary to earth: 1 × MOPP. System configuration Class I with FG. Suitable for BF applications with appropriate system consideration. Withstand voltage Input to output 4 kVAC; input to FG 2 kVAC; output to FG 1.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11), conducted and radiated Class B for Class I configuration. Harmonic current: BS EN/EN61000-3-2 Class A; flicker: BS EN/EN61000-3-3. Immunity framework BS EN/EN55035 and BS EN/EN60601-1-2. ESD BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF immunity BS EN/EN61000-4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9, 9–28 V/m at 385 MHz–5.78 GHz. EFT / burst and surge BS EN/EN61000-4-4: Level 3, 2 kV. BS EN/EN61000-4-5: Level 4, 4 kV line-to-FG and 2 kV line-to-line. Conducted and magnetic immunity BS EN/EN61000-4-6: Level 3, 10 V. BS EN/EN61000-4-8: Level 4, 30 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: 100% dip for 1 period, 30% dip for 25 periods, and 100% interruption for 250 periods. EMC testing used a 360 × 360 mm metal plate, 1 mm thick. This supply is an equipment component; EMC compliance must be confirmed again in the finished equipment. Weight, Reliability and Catalogue Reference Single-unit catalogue weight 330 g, from the explicit 0.33 kg per-unit PACKING entry. This is a catalogue reference, not a measured net or shipping weight. Packing reference 36 pieces / 12.9 kg / 0.96 CUFT. MTBF estimates 2082.3 thousand hours minimum, Telcordia SR-332 (Bellcore); 234.5 thousand hours minimum, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue revision RPS-160-SPEC 2026-02-28; combined PDF pages 37–40. MTBF is a statistical reliability estimate under the stated methods, not a guaranteed service life.

    $135.04

  • RPSG-160-12

    MEAN WELL RPS-160 series: Open-Frame Medical AC/DC Power Supply - RPSG-160-12

    MEAN WELL RPSG-160-12 is a 5 × 3-inch open-frame medical AC/DC power supply with a 12 V main output. The main-output current is 9.1 A with natural convection and 12.9 A with the specified 20.5 CFM airflow. G version with 5 V standby output and PS-ON control. It is intended for Class I equipment with protective grounding; BF applications require appropriate system consideration. Product Datasheet Download MEAN WELL RPS-160 Datasheet (PDF) The RPS-160 section is on PDF pages 37, 38, 39, 40. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPSG-160-12 Configuration G version with 5 V standby output and PS-ON control. Board format 127 × 76.2 mm (5 × 3 inches); open-frame PCB construction. Intended applications Oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices and pump equipment. Medical component approvals and isolation ratings do not certify the completed device. The equipment design must satisfy the applicable patient-protection, grounding, leakage-current and EMC requirements. Output Ratings and Cooling Conditions Nominal main output 12 V. Convection main-output current 0–9.1 A. Forced-air main-output current 0–12.9 A with at least 20.5 CFM as shown in the installation drawing. Main-output power at nominal voltage 109.2 W with convection and 154.8 W with 20.5 CFM, calculated from nominal voltage × the respective main-output current limit. Catalogue family combined-power entries 112.2 W with convection; 159.8 W with 20.5 CFM. The table footnotes include 5 V standby at 0.6 A and 0.8 A respectively. Voltage adjustment 10.8–13.2 V for the main output. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±3.0%; includes set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.0%. Efficiency, typical 87%. Use each rail’s voltage and current limit together with the cooling-mode total-power limit. The combined-power table is not a main-output-only rating and does not override any individual rail current limit. The standby rail is included in the total-power budget. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Input, Timing and Leakage Input range 90–264 VAC or 127–370 VDC; observe the low-input derating curve. Input frequency 47–63 Hz. AC current, typical 2 A at 115 VAC; 1.1 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up and rise time 1800 ms set-up at 230 VAC; 3500 ms at 115 VAC; 30 ms rise at either input, at full load. Hold-up time, typical 25 ms at 230 VAC; 20 ms at 115 VAC, at full load. Earth leakage current Less than 200 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Power-factor correction Built-in PFC; typical PF >0.93 at 230 VAC and >0.98 at 115 VAC, full load. Switching-frequency reference 70 kHz for the 12–48 V models. Protection Short circuit and overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage threshold 13.8–16.2 V. Overvoltage response Output shuts down; re-power to recover. Overtemperature response TSW1 shuts down the output and automatically recovers after temperature falls. TSW2 shuts down the output and requires re-powering to recover. Protection trip thresholds do not increase the usable output rating. Control and Monitoring Power Good / Power Fail timing 10 ms < PG < 500 ms; PF >1 ms. CN3 pin 1 is labelled PG and pin 2 GND; the pages do not assign a separate PF pin or provide an additional signal-current rating. Remote sense Available for this 12 V model: CN3 pin 3 −S and pin 4 +S. Status indication An LED is shown on the mechanical drawing. 5 V standby output 5 V at up to 0.6 A with convection or 0.8 A with 20.5 CFM; tolerance ±2%, ripple/noise 50 mVp-p maximum. PS-ON control G model only: high (2–5 V) turns the main output on; low (0–0.5 V) turns it off. The interface sketch marks 5 mA maximum. Standby and control connector CN901 pin 1 PS/ON; pins 2 and 4 GND; pin 3 5VSB. Low-power condition Input consumption below 0.5 W is specified using PS-ON control on the G model; it is not a blanket operating no-load figure for all versions. Temperature, Input Derating and Environment Working temperature −20 to +70°C with the applicable cooling and load restrictions. Horizontal-mounting temperature curve Natural convection: 100% of the convection rating through 40°C, falling to 40% at 60°C. With the specified fan airflow: 100% of the forced-air rating through 50°C, falling to 40% at 70°C. The no-fan curve ends at 60°C; do not extend it to 70°C. Input-voltage curve At 60 Hz, the graph permits 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes each along X, Y and Z. Operating altitude Up to 3,000 m. Above 2,000 m, reduce permitted ambient temperature by 3.5°C per additional 1,000 m for fanless operation, or 5°C per additional 1,000 m with a fan. Combine temperature, input-voltage and airflow restrictions. Do not interpret the maximum ambient temperature as a full-power rating. Installation and Mechanical Details Dimensions, L × W × H 127 × 76.2 × 34.6 mm. Mounting holes Four holes, diameter 3.5 mm; centre spacing 117 × 66.2 mm. Drawing references Edge-to-hole offsets are 5 mm and 5 mm as drawn. General dimensional tolerance ±1 mm; projection below the board 3 mm maximum. Forced-air arrangement At least 20.5 CFM; the drawing shows a fan 5 cm from the board edge, centred at the 63.5 mm longitudinal position, with airflow across the board in the indicated direction. Safety ground and chassis M1 is the safety-ground point. Secure electrical connections between M1, M2 and chassis ground for the specified installation and EMC performance. Heat sinks HS1, HS2 and HS3 must not be shorted together. Follow the complete mechanical drawing and manufacturer installation manual. The catalogue does not specify mounting-screw torque, supplied mounting hardware or a complete fan ordering code. The indicated airflow arrangement is required for the corresponding higher-load rating. Compatible Connectors and Mating Parts AC input CN1 JST B3P-VH or equivalent; pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. DC output CN2 JST B8P-VH or equivalent; pins 1–4 +V, pins 5–8 −V. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Power-Good / sense CN3 JST B4B-XH or equivalent; pin 1 PG, pin 2 GND, pin 3 −S, pin 4 +S. Mating housing is printed as JST XHP; terminal JST SXH-001T-P0.6 or equivalent. Sense is applicable to this model. Standby CN901 The catalogue prints JST B-XH or equivalent, mating housing JST XHP, terminal JST SXH-001T. Pin 1 PS/ON; pins 2 and 4 GND; pin 3 5VSB. The complete printed connector and terminal references above identify the documented interface parts. VHR and XHP are abbreviated housing-family references; B-XH and SXH-001T for CN901 are also incomplete ordering references. Confirm the full housing/contact suffix and circuit count with the connector supplier before ordering. No unprinted suffix or inclusion in the power-supply package is implied. Safety, Isolation and EMC Listed medical approvals IEC60601-1:2005+A1+A2; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Other design reference BS EN/EN60335-1 is listed as a design reference by request, not an unconditional standard configuration approval. Patient-protection isolation Primary to secondary: 2 × MOPP; primary to earth: 1 × MOPP; secondary to earth: 1 × MOPP. System configuration Class I with FG. Suitable for BF applications with appropriate system consideration. Withstand voltage Input to output 4 kVAC; input to FG 2 kVAC; output to FG 1.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11), conducted and radiated Class B for Class I configuration. Harmonic current: BS EN/EN61000-3-2 Class A; flicker: BS EN/EN61000-3-3. Immunity framework BS EN/EN55035 and BS EN/EN60601-1-2. ESD BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF immunity BS EN/EN61000-4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9, 9–28 V/m at 385 MHz–5.78 GHz. EFT / burst and surge BS EN/EN61000-4-4: Level 3, 2 kV. BS EN/EN61000-4-5: Level 4, 4 kV line-to-FG and 2 kV line-to-line. Conducted and magnetic immunity BS EN/EN61000-4-6: Level 3, 10 V. BS EN/EN61000-4-8: Level 4, 30 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: 100% dip for 1 period, 30% dip for 25 periods, and 100% interruption for 250 periods. EMC testing used a 360 × 360 mm metal plate, 1 mm thick. This supply is an equipment component; EMC compliance must be confirmed again in the finished equipment. Weight, Reliability and Catalogue Reference Single-unit catalogue weight 330 g, from the explicit 0.33 kg per-unit PACKING entry. This is a catalogue reference, not a measured net or shipping weight. Packing reference 36 pieces / 12.9 kg / 0.96 CUFT. MTBF estimates 2082.3 thousand hours minimum, Telcordia SR-332 (Bellcore); 234.5 thousand hours minimum, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue revision RPS-160-SPEC 2026-02-28; combined PDF pages 37–40. MTBF is a statistical reliability estimate under the stated methods, not a guaranteed service life.

    $135.04

  • RPSG-160-5

    MEAN WELL RPS-160 series: Open-Frame Medical AC/DC Power Supply - RPSG-160-5

    MEAN WELL RPSG-160-5 is a 5 × 3-inch open-frame medical AC/DC power supply with a 5 V main output. The main-output current is 20 A with natural convection and 30 A with the specified 20.5 CFM airflow. G version with 5 V standby output and PS-ON control. It is intended for Class I equipment with protective grounding; BF applications require appropriate system consideration. Product Datasheet Download MEAN WELL RPS-160 Datasheet (PDF) The RPS-160 section is on PDF pages 37, 38, 39, 40. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPSG-160-5 Configuration G version with 5 V standby output and PS-ON control. Board format 127 × 76.2 mm (5 × 3 inches); open-frame PCB construction. Intended applications Oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices and pump equipment. Medical component approvals and isolation ratings do not certify the completed device. The equipment design must satisfy the applicable patient-protection, grounding, leakage-current and EMC requirements. Output Ratings and Cooling Conditions Nominal main output 5 V. Convection main-output current 0–20 A. Forced-air main-output current 0–30 A with at least 20.5 CFM as shown in the installation drawing. Main-output power at nominal voltage 100 W with convection and 150 W with 20.5 CFM, calculated from nominal voltage × the respective main-output current limit. Catalogue family combined-power entries 103 W with convection; 155 W with 20.5 CFM. The table footnotes include 5 V standby at 0.6 A and 0.8 A respectively. Voltage adjustment 4.5–5.5 V for the main output. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±4.0%; includes set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.0%. Efficiency, typical 86%. Use each rail’s voltage and current limit together with the cooling-mode total-power limit. The combined-power table is not a main-output-only rating and does not override any individual rail current limit. The standby rail is included in the total-power budget. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Input, Timing and Leakage Input range 90–264 VAC or 127–370 VDC; observe the low-input derating curve. Input frequency 47–63 Hz. AC current, typical 2 A at 115 VAC; 1.1 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up and rise time 1800 ms set-up at 230 VAC; 3500 ms at 115 VAC; 30 ms rise at either input, at full load. Hold-up time, typical 25 ms at 230 VAC; 20 ms at 115 VAC, at full load. Earth leakage current Less than 200 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Power-factor correction Built-in PFC; typical PF >0.93 at 230 VAC and >0.98 at 115 VAC, full load. Switching-frequency reference 100 kHz for the 5 V model. Protection Short circuit and overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage threshold 5.7–6.8 V. Overvoltage response Output shuts down; re-power to recover. Overtemperature response TSW1 shuts down the output and automatically recovers after temperature falls. TSW2 shuts down the output and requires re-powering to recover. Protection trip thresholds do not increase the usable output rating. Control and Monitoring Power Good / Power Fail timing 10 ms < PG < 500 ms; PF >1 ms. CN3 pin 1 is labelled PG and pin 2 GND; the pages do not assign a separate PF pin or provide an additional signal-current rating. Remote sense Available for this 5 V model: CN3 pin 3 −S and pin 4 +S. Status indication An LED is shown on the mechanical drawing. 5 V standby output 5 V at up to 0.6 A with convection or 0.8 A with 20.5 CFM; tolerance ±2%, ripple/noise 50 mVp-p maximum. PS-ON control G model only: high (2–5 V) turns the main output on; low (0–0.5 V) turns it off. The interface sketch marks 5 mA maximum. Standby and control connector CN901 pin 1 PS/ON; pins 2 and 4 GND; pin 3 5VSB. Low-power condition Input consumption below 0.5 W is specified using PS-ON control on the G model; it is not a blanket operating no-load figure for all versions. Temperature, Input Derating and Environment Working temperature −20 to +70°C with the applicable cooling and load restrictions. Horizontal-mounting temperature curve Natural convection: 100% of the convection rating through 40°C, falling to 40% at 60°C. With the specified fan airflow: 100% of the forced-air rating through 50°C, falling to 40% at 70°C. The no-fan curve ends at 60°C; do not extend it to 70°C. Input-voltage curve At 60 Hz, the graph permits 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes each along X, Y and Z. Operating altitude Up to 3,000 m. Above 2,000 m, reduce permitted ambient temperature by 3.5°C per additional 1,000 m for fanless operation, or 5°C per additional 1,000 m with a fan. Combine temperature, input-voltage and airflow restrictions. Do not interpret the maximum ambient temperature as a full-power rating. Installation and Mechanical Details Dimensions, L × W × H 127 × 76.2 × 34.6 mm. Mounting holes Four holes, diameter 3.5 mm; centre spacing 117 × 66.2 mm. Drawing references Edge-to-hole offsets are 5 mm and 5 mm as drawn. General dimensional tolerance ±1 mm; projection below the board 3 mm maximum. Forced-air arrangement At least 20.5 CFM; the drawing shows a fan 5 cm from the board edge, centred at the 63.5 mm longitudinal position, with airflow across the board in the indicated direction. Safety ground and chassis M1 is the safety-ground point. Secure electrical connections between M1, M2 and chassis ground for the specified installation and EMC performance. Heat sinks HS1, HS2 and HS3 must not be shorted together. Follow the complete mechanical drawing and manufacturer installation manual. The catalogue does not specify mounting-screw torque, supplied mounting hardware or a complete fan ordering code. The indicated airflow arrangement is required for the corresponding higher-load rating. Compatible Connectors and Mating Parts AC input CN1 JST B3P-VH or equivalent; pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. DC output CN2 JST B8P-VH or equivalent; pins 1–4 +V, pins 5–8 −V. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Power-Good / sense CN3 JST B4B-XH or equivalent; pin 1 PG, pin 2 GND, pin 3 −S, pin 4 +S. Mating housing is printed as JST XHP; terminal JST SXH-001T-P0.6 or equivalent. Sense is applicable to this model. Standby CN901 The catalogue prints JST B-XH or equivalent, mating housing JST XHP, terminal JST SXH-001T. Pin 1 PS/ON; pins 2 and 4 GND; pin 3 5VSB. The complete printed connector and terminal references above identify the documented interface parts. VHR and XHP are abbreviated housing-family references; B-XH and SXH-001T for CN901 are also incomplete ordering references. Confirm the full housing/contact suffix and circuit count with the connector supplier before ordering. No unprinted suffix or inclusion in the power-supply package is implied. Safety, Isolation and EMC Listed medical approvals IEC60601-1:2005+A1+A2; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Other design reference BS EN/EN60335-1 is listed as a design reference by request, not an unconditional standard configuration approval. Patient-protection isolation Primary to secondary: 2 × MOPP; primary to earth: 1 × MOPP; secondary to earth: 1 × MOPP. System configuration Class I with FG. Suitable for BF applications with appropriate system consideration. Withstand voltage Input to output 4 kVAC; input to FG 2 kVAC; output to FG 1.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11), conducted and radiated Class B for Class I configuration. Harmonic current: BS EN/EN61000-3-2 Class A; flicker: BS EN/EN61000-3-3. Immunity framework BS EN/EN55035 and BS EN/EN60601-1-2. ESD BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF immunity BS EN/EN61000-4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9, 9–28 V/m at 385 MHz–5.78 GHz. EFT / burst and surge BS EN/EN61000-4-4: Level 3, 2 kV. BS EN/EN61000-4-5: Level 4, 4 kV line-to-FG and 2 kV line-to-line. Conducted and magnetic immunity BS EN/EN61000-4-6: Level 3, 10 V. BS EN/EN61000-4-8: Level 4, 30 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: 100% dip for 1 period, 30% dip for 25 periods, and 100% interruption for 250 periods. EMC testing used a 360 × 360 mm metal plate, 1 mm thick. This supply is an equipment component; EMC compliance must be confirmed again in the finished equipment. Weight, Reliability and Catalogue Reference Single-unit catalogue weight 330 g, from the explicit 0.33 kg per-unit PACKING entry. This is a catalogue reference, not a measured net or shipping weight. Packing reference 36 pieces / 12.9 kg / 0.96 CUFT. MTBF estimates 2082.3 thousand hours minimum, Telcordia SR-332 (Bellcore); 234.5 thousand hours minimum, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue revision RPS-160-SPEC 2026-02-28; combined PDF pages 37–40. MTBF is a statistical reliability estimate under the stated methods, not a guaranteed service life.

    $135.04

  • RPS-160-48

    MEAN WELL RPS-160 series: Open-Frame Medical AC/DC Power Supply - RPS-160-48

    MEAN WELL RPS-160-48 is a 5 × 3-inch open-frame medical AC/DC power supply with a 48 V main output. The main-output current is 2.3 A with natural convection and 3.25 A with the specified 20.5 CFM airflow. Blank type code: no 5 V standby output. It is intended for Class I equipment with protective grounding; BF applications require appropriate system consideration. Product Datasheet Download MEAN WELL RPS-160 Datasheet (PDF) The RPS-160 section is on PDF pages 37, 38, 39, 40. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPS-160-48 Configuration Blank type code: no 5 V standby output. Board format 127 × 76.2 mm (5 × 3 inches); open-frame PCB construction. Intended applications Oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices and pump equipment. Medical component approvals and isolation ratings do not certify the completed device. The equipment design must satisfy the applicable patient-protection, grounding, leakage-current and EMC requirements. Output Ratings and Cooling Conditions Nominal main output 48 V. Convection main-output current 0–2.3 A. Forced-air main-output current 0–3.25 A with at least 20.5 CFM as shown in the installation drawing. Main-output power at nominal voltage 110.4 W with convection and 156 W with 20.5 CFM, calculated from nominal voltage × the respective main-output current limit. Catalogue family combined-power entries 113.4 W with convection; 161 W with 20.5 CFM. The table footnotes include 5 V standby at 0.6 A and 0.8 A respectively. Voltage adjustment 43.2–52.8 V for the main output. Ripple and noise, maximum 150 mVp-p. Voltage tolerance ±2.0%; includes set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.0%. Efficiency, typical 88%. Use each rail’s voltage and current limit together with the cooling-mode total-power limit. The combined-power table is not a main-output-only rating and does not override any individual rail current limit. This blank-code model has no standby rail; do not allocate the family table’s standby allowance to the main output. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Input, Timing and Leakage Input range 90–264 VAC or 127–370 VDC; observe the low-input derating curve. Input frequency 47–63 Hz. AC current, typical 2 A at 115 VAC; 1.1 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up and rise time 1800 ms set-up at 230 VAC; 3500 ms at 115 VAC; 30 ms rise at either input, at full load. Hold-up time, typical 25 ms at 230 VAC; 20 ms at 115 VAC, at full load. Earth leakage current Less than 200 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Power-factor correction Built-in PFC; typical PF >0.93 at 230 VAC and >0.98 at 115 VAC, full load. Switching-frequency reference 70 kHz for the 12–48 V models. Protection Short circuit and overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage threshold 55.2–64.8 V. Overvoltage response Output shuts down; re-power to recover. Overtemperature response TSW1 shuts down the output and automatically recovers after temperature falls. TSW2 shuts down the output and requires re-powering to recover. Protection trip thresholds do not increase the usable output rating. Control and Monitoring Power Good / Power Fail timing 10 ms < PG < 500 ms; PF >1 ms. CN3 pin 1 is labelled PG and pin 2 GND; the pages do not assign a separate PF pin or provide an additional signal-current rating. Remote sense The catalogue limits remote sense to the 5–15 V models; it is not specified for this 48 V output. Status indication An LED is shown on the mechanical drawing. Temperature, Input Derating and Environment Working temperature −20 to +70°C with the applicable cooling and load restrictions. Horizontal-mounting temperature curve Natural convection: 100% of the convection rating through 40°C, falling to 40% at 60°C. With the specified fan airflow: 100% of the forced-air rating through 50°C, falling to 40% at 70°C. The no-fan curve ends at 60°C; do not extend it to 70°C. Input-voltage curve At 60 Hz, the graph permits 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes each along X, Y and Z. Operating altitude Up to 3,000 m. Above 2,000 m, reduce permitted ambient temperature by 3.5°C per additional 1,000 m for fanless operation, or 5°C per additional 1,000 m with a fan. Combine temperature, input-voltage and airflow restrictions. Do not interpret the maximum ambient temperature as a full-power rating. Installation and Mechanical Details Dimensions, L × W × H 127 × 76.2 × 34.6 mm. Mounting holes Four holes, diameter 3.5 mm; centre spacing 117 × 66.2 mm. Drawing references Edge-to-hole offsets are 5 mm and 5 mm as drawn. General dimensional tolerance ±1 mm; projection below the board 3 mm maximum. Forced-air arrangement At least 20.5 CFM; the drawing shows a fan 5 cm from the board edge, centred at the 63.5 mm longitudinal position, with airflow across the board in the indicated direction. Safety ground and chassis M1 is the safety-ground point. Secure electrical connections between M1, M2 and chassis ground for the specified installation and EMC performance. Heat sinks HS1, HS2 and HS3 must not be shorted together. Follow the complete mechanical drawing and manufacturer installation manual. The catalogue does not specify mounting-screw torque, supplied mounting hardware or a complete fan ordering code. The indicated airflow arrangement is required for the corresponding higher-load rating. Compatible Connectors and Mating Parts AC input CN1 JST B3P-VH or equivalent; pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. DC output CN2 JST B8P-VH or equivalent; pins 1–4 +V, pins 5–8 −V. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Power-Good / sense CN3 JST B4B-XH or equivalent; pin 1 PG, pin 2 GND, pin 3 −S, pin 4 +S. Mating housing is printed as JST XHP; terminal JST SXH-001T-P0.6 or equivalent. Use sense pins only on the 5–15 V models. The complete printed connector and terminal references above identify the documented interface parts. VHR and XHP are abbreviated housing-family references; Confirm the full housing/contact suffix and circuit count with the connector supplier before ordering. No unprinted suffix or inclusion in the power-supply package is implied. Safety, Isolation and EMC Listed medical approvals IEC60601-1:2005+A1+A2; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Other design reference BS EN/EN60335-1 is listed as a design reference by request, not an unconditional standard configuration approval. Patient-protection isolation Primary to secondary: 2 × MOPP; primary to earth: 1 × MOPP; secondary to earth: 1 × MOPP. System configuration Class I with FG. Suitable for BF applications with appropriate system consideration. Withstand voltage Input to output 4 kVAC; input to FG 2 kVAC; output to FG 1.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11), conducted and radiated Class B for Class I configuration. Harmonic current: BS EN/EN61000-3-2 Class A; flicker: BS EN/EN61000-3-3. Immunity framework BS EN/EN55035 and BS EN/EN60601-1-2. ESD BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF immunity BS EN/EN61000-4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9, 9–28 V/m at 385 MHz–5.78 GHz. EFT / burst and surge BS EN/EN61000-4-4: Level 3, 2 kV. BS EN/EN61000-4-5: Level 4, 4 kV line-to-FG and 2 kV line-to-line. Conducted and magnetic immunity BS EN/EN61000-4-6: Level 3, 10 V. BS EN/EN61000-4-8: Level 4, 30 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: 100% dip for 1 period, 30% dip for 25 periods, and 100% interruption for 250 periods. EMC testing used a 360 × 360 mm metal plate, 1 mm thick. This supply is an equipment component; EMC compliance must be confirmed again in the finished equipment. Weight, Reliability and Catalogue Reference Single-unit catalogue weight 330 g, from the explicit 0.33 kg per-unit PACKING entry. This is a catalogue reference, not a measured net or shipping weight. Packing reference 36 pieces / 12.9 kg / 0.96 CUFT. MTBF estimates 2082.3 thousand hours minimum, Telcordia SR-332 (Bellcore); 234.5 thousand hours minimum, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue revision RPS-160-SPEC 2026-02-28; combined PDF pages 37–40. MTBF is a statistical reliability estimate under the stated methods, not a guaranteed service life.

    $104.98

  • RPS-160-24

    MEAN WELL RPS-160 series: Open-Frame Medical AC/DC Power Supply - RPS-160-24

    MEAN WELL RPS-160-24 is a 5 × 3-inch open-frame medical AC/DC power supply with a 24 V main output. The main-output current is 4.6 A with natural convection and 6.5 A with the specified 20.5 CFM airflow. Blank type code: no 5 V standby output. It is intended for Class I equipment with protective grounding; BF applications require appropriate system consideration. Product Datasheet Download MEAN WELL RPS-160 Datasheet (PDF) The RPS-160 section is on PDF pages 37, 38, 39, 40. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPS-160-24 Configuration Blank type code: no 5 V standby output. Board format 127 × 76.2 mm (5 × 3 inches); open-frame PCB construction. Intended applications Oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices and pump equipment. Medical component approvals and isolation ratings do not certify the completed device. The equipment design must satisfy the applicable patient-protection, grounding, leakage-current and EMC requirements. Output Ratings and Cooling Conditions Nominal main output 24 V. Convection main-output current 0–4.6 A. Forced-air main-output current 0–6.5 A with at least 20.5 CFM as shown in the installation drawing. Main-output power at nominal voltage 110.4 W with convection and 156 W with 20.5 CFM, calculated from nominal voltage × the respective main-output current limit. Catalogue family combined-power entries 113.4 W with convection; 161 W with 20.5 CFM. The table footnotes include 5 V standby at 0.6 A and 0.8 A respectively. Voltage adjustment 22–27 V for the main output. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±2.0%; includes set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.0%. Efficiency, typical 87%. Use each rail’s voltage and current limit together with the cooling-mode total-power limit. The combined-power table is not a main-output-only rating and does not override any individual rail current limit. This blank-code model has no standby rail; do not allocate the family table’s standby allowance to the main output. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Input, Timing and Leakage Input range 90–264 VAC or 127–370 VDC; observe the low-input derating curve. Input frequency 47–63 Hz. AC current, typical 2 A at 115 VAC; 1.1 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up and rise time 1800 ms set-up at 230 VAC; 3500 ms at 115 VAC; 30 ms rise at either input, at full load. Hold-up time, typical 25 ms at 230 VAC; 20 ms at 115 VAC, at full load. Earth leakage current Less than 200 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Power-factor correction Built-in PFC; typical PF >0.93 at 230 VAC and >0.98 at 115 VAC, full load. Switching-frequency reference 70 kHz for the 12–48 V models. Protection Short circuit and overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage threshold 27.6–32.4 V. Overvoltage response Output shuts down; re-power to recover. Overtemperature response TSW1 shuts down the output and automatically recovers after temperature falls. TSW2 shuts down the output and requires re-powering to recover. Protection trip thresholds do not increase the usable output rating. Control and Monitoring Power Good / Power Fail timing 10 ms < PG < 500 ms; PF >1 ms. CN3 pin 1 is labelled PG and pin 2 GND; the pages do not assign a separate PF pin or provide an additional signal-current rating. Remote sense The catalogue limits remote sense to the 5–15 V models; it is not specified for this 24 V output. Status indication An LED is shown on the mechanical drawing. Temperature, Input Derating and Environment Working temperature −20 to +70°C with the applicable cooling and load restrictions. Horizontal-mounting temperature curve Natural convection: 100% of the convection rating through 40°C, falling to 40% at 60°C. With the specified fan airflow: 100% of the forced-air rating through 50°C, falling to 40% at 70°C. The no-fan curve ends at 60°C; do not extend it to 70°C. Input-voltage curve At 60 Hz, the graph permits 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes each along X, Y and Z. Operating altitude Up to 3,000 m. Above 2,000 m, reduce permitted ambient temperature by 3.5°C per additional 1,000 m for fanless operation, or 5°C per additional 1,000 m with a fan. Combine temperature, input-voltage and airflow restrictions. Do not interpret the maximum ambient temperature as a full-power rating. Installation and Mechanical Details Dimensions, L × W × H 127 × 76.2 × 34.6 mm. Mounting holes Four holes, diameter 3.5 mm; centre spacing 117 × 66.2 mm. Drawing references Edge-to-hole offsets are 5 mm and 5 mm as drawn. General dimensional tolerance ±1 mm; projection below the board 3 mm maximum. Forced-air arrangement At least 20.5 CFM; the drawing shows a fan 5 cm from the board edge, centred at the 63.5 mm longitudinal position, with airflow across the board in the indicated direction. Safety ground and chassis M1 is the safety-ground point. Secure electrical connections between M1, M2 and chassis ground for the specified installation and EMC performance. Heat sinks HS1, HS2 and HS3 must not be shorted together. Follow the complete mechanical drawing and manufacturer installation manual. The catalogue does not specify mounting-screw torque, supplied mounting hardware or a complete fan ordering code. The indicated airflow arrangement is required for the corresponding higher-load rating. Compatible Connectors and Mating Parts AC input CN1 JST B3P-VH or equivalent; pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. DC output CN2 JST B8P-VH or equivalent; pins 1–4 +V, pins 5–8 −V. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Power-Good / sense CN3 JST B4B-XH or equivalent; pin 1 PG, pin 2 GND, pin 3 −S, pin 4 +S. Mating housing is printed as JST XHP; terminal JST SXH-001T-P0.6 or equivalent. Use sense pins only on the 5–15 V models. The complete printed connector and terminal references above identify the documented interface parts. VHR and XHP are abbreviated housing-family references; Confirm the full housing/contact suffix and circuit count with the connector supplier before ordering. No unprinted suffix or inclusion in the power-supply package is implied. Safety, Isolation and EMC Listed medical approvals IEC60601-1:2005+A1+A2; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Other design reference BS EN/EN60335-1 is listed as a design reference by request, not an unconditional standard configuration approval. Patient-protection isolation Primary to secondary: 2 × MOPP; primary to earth: 1 × MOPP; secondary to earth: 1 × MOPP. System configuration Class I with FG. Suitable for BF applications with appropriate system consideration. Withstand voltage Input to output 4 kVAC; input to FG 2 kVAC; output to FG 1.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11), conducted and radiated Class B for Class I configuration. Harmonic current: BS EN/EN61000-3-2 Class A; flicker: BS EN/EN61000-3-3. Immunity framework BS EN/EN55035 and BS EN/EN60601-1-2. ESD BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF immunity BS EN/EN61000-4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9, 9–28 V/m at 385 MHz–5.78 GHz. EFT / burst and surge BS EN/EN61000-4-4: Level 3, 2 kV. BS EN/EN61000-4-5: Level 4, 4 kV line-to-FG and 2 kV line-to-line. Conducted and magnetic immunity BS EN/EN61000-4-6: Level 3, 10 V. BS EN/EN61000-4-8: Level 4, 30 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: 100% dip for 1 period, 30% dip for 25 periods, and 100% interruption for 250 periods. EMC testing used a 360 × 360 mm metal plate, 1 mm thick. This supply is an equipment component; EMC compliance must be confirmed again in the finished equipment. Weight, Reliability and Catalogue Reference Single-unit catalogue weight 330 g, from the explicit 0.33 kg per-unit PACKING entry. This is a catalogue reference, not a measured net or shipping weight. Packing reference 36 pieces / 12.9 kg / 0.96 CUFT. MTBF estimates 2082.3 thousand hours minimum, Telcordia SR-332 (Bellcore); 234.5 thousand hours minimum, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue revision RPS-160-SPEC 2026-02-28; combined PDF pages 37–40. MTBF is a statistical reliability estimate under the stated methods, not a guaranteed service life.

    $104.98

  • RPS-160-15

    MEAN WELL RPS-160 series: Open-Frame Medical AC/DC Power Supply - RPS-160-15

    MEAN WELL RPS-160-15 is a 5 × 3-inch open-frame medical AC/DC power supply with a 15 V main output. The main-output current is 7.3 A with natural convection and 10.3 A with the specified 20.5 CFM airflow. Blank type code: no 5 V standby output. It is intended for Class I equipment with protective grounding; BF applications require appropriate system consideration. Product Datasheet Download MEAN WELL RPS-160 Datasheet (PDF) The RPS-160 section is on PDF pages 37, 38, 39, 40. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPS-160-15 Configuration Blank type code: no 5 V standby output. Board format 127 × 76.2 mm (5 × 3 inches); open-frame PCB construction. Intended applications Oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices and pump equipment. Medical component approvals and isolation ratings do not certify the completed device. The equipment design must satisfy the applicable patient-protection, grounding, leakage-current and EMC requirements. Output Ratings and Cooling Conditions Nominal main output 15 V. Convection main-output current 0–7.3 A. Forced-air main-output current 0–10.3 A with at least 20.5 CFM as shown in the installation drawing. Main-output power at nominal voltage 109.5 W with convection and 154.5 W with 20.5 CFM, calculated from nominal voltage × the respective main-output current limit. Catalogue family combined-power entries 112.5 W with convection; 159.5 W with 20.5 CFM. The table footnotes include 5 V standby at 0.6 A and 0.8 A respectively. Voltage adjustment 13.5–16.5 V for the main output. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±3.0%; includes set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.0%. Efficiency, typical 87%. Use each rail’s voltage and current limit together with the cooling-mode total-power limit. The combined-power table is not a main-output-only rating and does not override any individual rail current limit. This blank-code model has no standby rail; do not allocate the family table’s standby allowance to the main output. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Input, Timing and Leakage Input range 90–264 VAC or 127–370 VDC; observe the low-input derating curve. Input frequency 47–63 Hz. AC current, typical 2 A at 115 VAC; 1.1 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up and rise time 1800 ms set-up at 230 VAC; 3500 ms at 115 VAC; 30 ms rise at either input, at full load. Hold-up time, typical 25 ms at 230 VAC; 20 ms at 115 VAC, at full load. Earth leakage current Less than 200 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Power-factor correction Built-in PFC; typical PF >0.93 at 230 VAC and >0.98 at 115 VAC, full load. Switching-frequency reference 70 kHz for the 12–48 V models. Protection Short circuit and overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage threshold 17.2–20.3 V. Overvoltage response Output shuts down; re-power to recover. Overtemperature response TSW1 shuts down the output and automatically recovers after temperature falls. TSW2 shuts down the output and requires re-powering to recover. Protection trip thresholds do not increase the usable output rating. Control and Monitoring Power Good / Power Fail timing 10 ms < PG < 500 ms; PF >1 ms. CN3 pin 1 is labelled PG and pin 2 GND; the pages do not assign a separate PF pin or provide an additional signal-current rating. Remote sense Available for this 15 V model: CN3 pin 3 −S and pin 4 +S. Status indication An LED is shown on the mechanical drawing. Temperature, Input Derating and Environment Working temperature −20 to +70°C with the applicable cooling and load restrictions. Horizontal-mounting temperature curve Natural convection: 100% of the convection rating through 40°C, falling to 40% at 60°C. With the specified fan airflow: 100% of the forced-air rating through 50°C, falling to 40% at 70°C. The no-fan curve ends at 60°C; do not extend it to 70°C. Input-voltage curve At 60 Hz, the graph permits 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes each along X, Y and Z. Operating altitude Up to 3,000 m. Above 2,000 m, reduce permitted ambient temperature by 3.5°C per additional 1,000 m for fanless operation, or 5°C per additional 1,000 m with a fan. Combine temperature, input-voltage and airflow restrictions. Do not interpret the maximum ambient temperature as a full-power rating. Installation and Mechanical Details Dimensions, L × W × H 127 × 76.2 × 34.6 mm. Mounting holes Four holes, diameter 3.5 mm; centre spacing 117 × 66.2 mm. Drawing references Edge-to-hole offsets are 5 mm and 5 mm as drawn. General dimensional tolerance ±1 mm; projection below the board 3 mm maximum. Forced-air arrangement At least 20.5 CFM; the drawing shows a fan 5 cm from the board edge, centred at the 63.5 mm longitudinal position, with airflow across the board in the indicated direction. Safety ground and chassis M1 is the safety-ground point. Secure electrical connections between M1, M2 and chassis ground for the specified installation and EMC performance. Heat sinks HS1, HS2 and HS3 must not be shorted together. Follow the complete mechanical drawing and manufacturer installation manual. The catalogue does not specify mounting-screw torque, supplied mounting hardware or a complete fan ordering code. The indicated airflow arrangement is required for the corresponding higher-load rating. Compatible Connectors and Mating Parts AC input CN1 JST B3P-VH or equivalent; pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. DC output CN2 JST B8P-VH or equivalent; pins 1–4 +V, pins 5–8 −V. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Power-Good / sense CN3 JST B4B-XH or equivalent; pin 1 PG, pin 2 GND, pin 3 −S, pin 4 +S. Mating housing is printed as JST XHP; terminal JST SXH-001T-P0.6 or equivalent. Sense is applicable to this model. The complete printed connector and terminal references above identify the documented interface parts. VHR and XHP are abbreviated housing-family references; Confirm the full housing/contact suffix and circuit count with the connector supplier before ordering. No unprinted suffix or inclusion in the power-supply package is implied. Safety, Isolation and EMC Listed medical approvals IEC60601-1:2005+A1+A2; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Other design reference BS EN/EN60335-1 is listed as a design reference by request, not an unconditional standard configuration approval. Patient-protection isolation Primary to secondary: 2 × MOPP; primary to earth: 1 × MOPP; secondary to earth: 1 × MOPP. System configuration Class I with FG. Suitable for BF applications with appropriate system consideration. Withstand voltage Input to output 4 kVAC; input to FG 2 kVAC; output to FG 1.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11), conducted and radiated Class B for Class I configuration. Harmonic current: BS EN/EN61000-3-2 Class A; flicker: BS EN/EN61000-3-3. Immunity framework BS EN/EN55035 and BS EN/EN60601-1-2. ESD BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF immunity BS EN/EN61000-4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9, 9–28 V/m at 385 MHz–5.78 GHz. EFT / burst and surge BS EN/EN61000-4-4: Level 3, 2 kV. BS EN/EN61000-4-5: Level 4, 4 kV line-to-FG and 2 kV line-to-line. Conducted and magnetic immunity BS EN/EN61000-4-6: Level 3, 10 V. BS EN/EN61000-4-8: Level 4, 30 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: 100% dip for 1 period, 30% dip for 25 periods, and 100% interruption for 250 periods. EMC testing used a 360 × 360 mm metal plate, 1 mm thick. This supply is an equipment component; EMC compliance must be confirmed again in the finished equipment. Weight, Reliability and Catalogue Reference Single-unit catalogue weight 330 g, from the explicit 0.33 kg per-unit PACKING entry. This is a catalogue reference, not a measured net or shipping weight. Packing reference 36 pieces / 12.9 kg / 0.96 CUFT. MTBF estimates 2082.3 thousand hours minimum, Telcordia SR-332 (Bellcore); 234.5 thousand hours minimum, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue revision RPS-160-SPEC 2026-02-28; combined PDF pages 37–40. MTBF is a statistical reliability estimate under the stated methods, not a guaranteed service life.

    $104.98

  • RPS-160-12

    MEAN WELL RPS-160 series: Open-Frame Medical AC/DC Power Supply - RPS-160-12

    MEAN WELL RPS-160-12 is a 5 × 3-inch open-frame medical AC/DC power supply with a 12 V main output. The main-output current is 9.1 A with natural convection and 12.9 A with the specified 20.5 CFM airflow. Blank type code: no 5 V standby output. It is intended for Class I equipment with protective grounding; BF applications require appropriate system consideration. Product Datasheet Download MEAN WELL RPS-160 Datasheet (PDF) The RPS-160 section is on PDF pages 37, 38, 39, 40. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPS-160-12 Configuration Blank type code: no 5 V standby output. Board format 127 × 76.2 mm (5 × 3 inches); open-frame PCB construction. Intended applications Oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices and pump equipment. Medical component approvals and isolation ratings do not certify the completed device. The equipment design must satisfy the applicable patient-protection, grounding, leakage-current and EMC requirements. Output Ratings and Cooling Conditions Nominal main output 12 V. Convection main-output current 0–9.1 A. Forced-air main-output current 0–12.9 A with at least 20.5 CFM as shown in the installation drawing. Main-output power at nominal voltage 109.2 W with convection and 154.8 W with 20.5 CFM, calculated from nominal voltage × the respective main-output current limit. Catalogue family combined-power entries 112.2 W with convection; 159.8 W with 20.5 CFM. The table footnotes include 5 V standby at 0.6 A and 0.8 A respectively. Voltage adjustment 10.8–13.2 V for the main output. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±3.0%; includes set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.0%. Efficiency, typical 87%. Use each rail’s voltage and current limit together with the cooling-mode total-power limit. The combined-power table is not a main-output-only rating and does not override any individual rail current limit. This blank-code model has no standby rail; do not allocate the family table’s standby allowance to the main output. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Input, Timing and Leakage Input range 90–264 VAC or 127–370 VDC; observe the low-input derating curve. Input frequency 47–63 Hz. AC current, typical 2 A at 115 VAC; 1.1 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up and rise time 1800 ms set-up at 230 VAC; 3500 ms at 115 VAC; 30 ms rise at either input, at full load. Hold-up time, typical 25 ms at 230 VAC; 20 ms at 115 VAC, at full load. Earth leakage current Less than 200 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Power-factor correction Built-in PFC; typical PF >0.93 at 230 VAC and >0.98 at 115 VAC, full load. Switching-frequency reference 70 kHz for the 12–48 V models. Protection Short circuit and overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage threshold 13.8–16.2 V. Overvoltage response Output shuts down; re-power to recover. Overtemperature response TSW1 shuts down the output and automatically recovers after temperature falls. TSW2 shuts down the output and requires re-powering to recover. Protection trip thresholds do not increase the usable output rating. Control and Monitoring Power Good / Power Fail timing 10 ms < PG < 500 ms; PF >1 ms. CN3 pin 1 is labelled PG and pin 2 GND; the pages do not assign a separate PF pin or provide an additional signal-current rating. Remote sense Available for this 12 V model: CN3 pin 3 −S and pin 4 +S. Status indication An LED is shown on the mechanical drawing. Temperature, Input Derating and Environment Working temperature −20 to +70°C with the applicable cooling and load restrictions. Horizontal-mounting temperature curve Natural convection: 100% of the convection rating through 40°C, falling to 40% at 60°C. With the specified fan airflow: 100% of the forced-air rating through 50°C, falling to 40% at 70°C. The no-fan curve ends at 60°C; do not extend it to 70°C. Input-voltage curve At 60 Hz, the graph permits 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes each along X, Y and Z. Operating altitude Up to 3,000 m. Above 2,000 m, reduce permitted ambient temperature by 3.5°C per additional 1,000 m for fanless operation, or 5°C per additional 1,000 m with a fan. Combine temperature, input-voltage and airflow restrictions. Do not interpret the maximum ambient temperature as a full-power rating. Installation and Mechanical Details Dimensions, L × W × H 127 × 76.2 × 34.6 mm. Mounting holes Four holes, diameter 3.5 mm; centre spacing 117 × 66.2 mm. Drawing references Edge-to-hole offsets are 5 mm and 5 mm as drawn. General dimensional tolerance ±1 mm; projection below the board 3 mm maximum. Forced-air arrangement At least 20.5 CFM; the drawing shows a fan 5 cm from the board edge, centred at the 63.5 mm longitudinal position, with airflow across the board in the indicated direction. Safety ground and chassis M1 is the safety-ground point. Secure electrical connections between M1, M2 and chassis ground for the specified installation and EMC performance. Heat sinks HS1, HS2 and HS3 must not be shorted together. Follow the complete mechanical drawing and manufacturer installation manual. The catalogue does not specify mounting-screw torque, supplied mounting hardware or a complete fan ordering code. The indicated airflow arrangement is required for the corresponding higher-load rating. Compatible Connectors and Mating Parts AC input CN1 JST B3P-VH or equivalent; pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. DC output CN2 JST B8P-VH or equivalent; pins 1–4 +V, pins 5–8 −V. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Power-Good / sense CN3 JST B4B-XH or equivalent; pin 1 PG, pin 2 GND, pin 3 −S, pin 4 +S. Mating housing is printed as JST XHP; terminal JST SXH-001T-P0.6 or equivalent. Sense is applicable to this model. The complete printed connector and terminal references above identify the documented interface parts. VHR and XHP are abbreviated housing-family references; Confirm the full housing/contact suffix and circuit count with the connector supplier before ordering. No unprinted suffix or inclusion in the power-supply package is implied. Safety, Isolation and EMC Listed medical approvals IEC60601-1:2005+A1+A2; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Other design reference BS EN/EN60335-1 is listed as a design reference by request, not an unconditional standard configuration approval. Patient-protection isolation Primary to secondary: 2 × MOPP; primary to earth: 1 × MOPP; secondary to earth: 1 × MOPP. System configuration Class I with FG. Suitable for BF applications with appropriate system consideration. Withstand voltage Input to output 4 kVAC; input to FG 2 kVAC; output to FG 1.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11), conducted and radiated Class B for Class I configuration. Harmonic current: BS EN/EN61000-3-2 Class A; flicker: BS EN/EN61000-3-3. Immunity framework BS EN/EN55035 and BS EN/EN60601-1-2. ESD BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF immunity BS EN/EN61000-4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9, 9–28 V/m at 385 MHz–5.78 GHz. EFT / burst and surge BS EN/EN61000-4-4: Level 3, 2 kV. BS EN/EN61000-4-5: Level 4, 4 kV line-to-FG and 2 kV line-to-line. Conducted and magnetic immunity BS EN/EN61000-4-6: Level 3, 10 V. BS EN/EN61000-4-8: Level 4, 30 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: 100% dip for 1 period, 30% dip for 25 periods, and 100% interruption for 250 periods. EMC testing used a 360 × 360 mm metal plate, 1 mm thick. This supply is an equipment component; EMC compliance must be confirmed again in the finished equipment. Weight, Reliability and Catalogue Reference Single-unit catalogue weight 330 g, from the explicit 0.33 kg per-unit PACKING entry. This is a catalogue reference, not a measured net or shipping weight. Packing reference 36 pieces / 12.9 kg / 0.96 CUFT. MTBF estimates 2082.3 thousand hours minimum, Telcordia SR-332 (Bellcore); 234.5 thousand hours minimum, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue revision RPS-160-SPEC 2026-02-28; combined PDF pages 37–40. MTBF is a statistical reliability estimate under the stated methods, not a guaranteed service life.

    $104.98

  • RPS-160-5

    MEAN WELL RPS-160 series: Open-Frame Medical AC/DC Power Supply - RPS-160-5

    MEAN WELL RPS-160-5 is a 5 × 3-inch open-frame medical AC/DC power supply with a 5 V main output. The main-output current is 20 A with natural convection and 30 A with the specified 20.5 CFM airflow. Blank type code: no 5 V standby output. It is intended for Class I equipment with protective grounding; BF applications require appropriate system consideration. Product Datasheet Download MEAN WELL RPS-160 Datasheet (PDF) The RPS-160 section is on PDF pages 37, 38, 39, 40. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPS-160-5 Configuration Blank type code: no 5 V standby output. Board format 127 × 76.2 mm (5 × 3 inches); open-frame PCB construction. Intended applications Oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices and pump equipment. Medical component approvals and isolation ratings do not certify the completed device. The equipment design must satisfy the applicable patient-protection, grounding, leakage-current and EMC requirements. Output Ratings and Cooling Conditions Nominal main output 5 V. Convection main-output current 0–20 A. Forced-air main-output current 0–30 A with at least 20.5 CFM as shown in the installation drawing. Main-output power at nominal voltage 100 W with convection and 150 W with 20.5 CFM, calculated from nominal voltage × the respective main-output current limit. Catalogue family combined-power entries 103 W with convection; 155 W with 20.5 CFM. The table footnotes include 5 V standby at 0.6 A and 0.8 A respectively. Voltage adjustment 4.5–5.5 V for the main output. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±4.0%; includes set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.0%. Efficiency, typical 86%. Use each rail’s voltage and current limit together with the cooling-mode total-power limit. The combined-power table is not a main-output-only rating and does not override any individual rail current limit. This blank-code model has no standby rail; do not allocate the family table’s standby allowance to the main output. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Input, Timing and Leakage Input range 90–264 VAC or 127–370 VDC; observe the low-input derating curve. Input frequency 47–63 Hz. AC current, typical 2 A at 115 VAC; 1.1 A at 230 VAC. Cold-start inrush, typical 35 A at 115 VAC; 70 A at 230 VAC. Set-up and rise time 1800 ms set-up at 230 VAC; 3500 ms at 115 VAC; 30 ms rise at either input, at full load. Hold-up time, typical 25 ms at 230 VAC; 20 ms at 115 VAC, at full load. Earth leakage current Less than 200 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. Power-factor correction Built-in PFC; typical PF >0.93 at 230 VAC and >0.98 at 115 VAC, full load. Switching-frequency reference 100 kHz for the 5 V model. Protection Short circuit and overload 105–135% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage threshold 5.7–6.8 V. Overvoltage response Output shuts down; re-power to recover. Overtemperature response TSW1 shuts down the output and automatically recovers after temperature falls. TSW2 shuts down the output and requires re-powering to recover. Protection trip thresholds do not increase the usable output rating. Control and Monitoring Power Good / Power Fail timing 10 ms < PG < 500 ms; PF >1 ms. CN3 pin 1 is labelled PG and pin 2 GND; the pages do not assign a separate PF pin or provide an additional signal-current rating. Remote sense Available for this 5 V model: CN3 pin 3 −S and pin 4 +S. Status indication An LED is shown on the mechanical drawing. Temperature, Input Derating and Environment Working temperature −20 to +70°C with the applicable cooling and load restrictions. Horizontal-mounting temperature curve Natural convection: 100% of the convection rating through 40°C, falling to 40% at 60°C. With the specified fan airflow: 100% of the forced-air rating through 50°C, falling to 40% at 70°C. The no-fan curve ends at 60°C; do not extend it to 70°C. Input-voltage curve At 60 Hz, the graph permits 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes each along X, Y and Z. Operating altitude Up to 3,000 m. Above 2,000 m, reduce permitted ambient temperature by 3.5°C per additional 1,000 m for fanless operation, or 5°C per additional 1,000 m with a fan. Combine temperature, input-voltage and airflow restrictions. Do not interpret the maximum ambient temperature as a full-power rating. Installation and Mechanical Details Dimensions, L × W × H 127 × 76.2 × 34.6 mm. Mounting holes Four holes, diameter 3.5 mm; centre spacing 117 × 66.2 mm. Drawing references Edge-to-hole offsets are 5 mm and 5 mm as drawn. General dimensional tolerance ±1 mm; projection below the board 3 mm maximum. Forced-air arrangement At least 20.5 CFM; the drawing shows a fan 5 cm from the board edge, centred at the 63.5 mm longitudinal position, with airflow across the board in the indicated direction. Safety ground and chassis M1 is the safety-ground point. Secure electrical connections between M1, M2 and chassis ground for the specified installation and EMC performance. Heat sinks HS1, HS2 and HS3 must not be shorted together. Follow the complete mechanical drawing and manufacturer installation manual. The catalogue does not specify mounting-screw torque, supplied mounting hardware or a complete fan ordering code. The indicated airflow arrangement is required for the corresponding higher-load rating. Compatible Connectors and Mating Parts AC input CN1 JST B3P-VH or equivalent; pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. DC output CN2 JST B8P-VH or equivalent; pins 1–4 +V, pins 5–8 −V. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Power-Good / sense CN3 JST B4B-XH or equivalent; pin 1 PG, pin 2 GND, pin 3 −S, pin 4 +S. Mating housing is printed as JST XHP; terminal JST SXH-001T-P0.6 or equivalent. Sense is applicable to this model. The complete printed connector and terminal references above identify the documented interface parts. VHR and XHP are abbreviated housing-family references; Confirm the full housing/contact suffix and circuit count with the connector supplier before ordering. No unprinted suffix or inclusion in the power-supply package is implied. Safety, Isolation and EMC Listed medical approvals IEC60601-1:2005+A1+A2; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Other design reference BS EN/EN60335-1 is listed as a design reference by request, not an unconditional standard configuration approval. Patient-protection isolation Primary to secondary: 2 × MOPP; primary to earth: 1 × MOPP; secondary to earth: 1 × MOPP. System configuration Class I with FG. Suitable for BF applications with appropriate system consideration. Withstand voltage Input to output 4 kVAC; input to FG 2 kVAC; output to FG 1.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11), conducted and radiated Class B for Class I configuration. Harmonic current: BS EN/EN61000-3-2 Class A; flicker: BS EN/EN61000-3-3. Immunity framework BS EN/EN55035 and BS EN/EN60601-1-2. ESD BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF immunity BS EN/EN61000-4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9, 9–28 V/m at 385 MHz–5.78 GHz. EFT / burst and surge BS EN/EN61000-4-4: Level 3, 2 kV. BS EN/EN61000-4-5: Level 4, 4 kV line-to-FG and 2 kV line-to-line. Conducted and magnetic immunity BS EN/EN61000-4-6: Level 3, 10 V. BS EN/EN61000-4-8: Level 4, 30 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: 100% dip for 1 period, 30% dip for 25 periods, and 100% interruption for 250 periods. EMC testing used a 360 × 360 mm metal plate, 1 mm thick. This supply is an equipment component; EMC compliance must be confirmed again in the finished equipment. Weight, Reliability and Catalogue Reference Single-unit catalogue weight 330 g, from the explicit 0.33 kg per-unit PACKING entry. This is a catalogue reference, not a measured net or shipping weight. Packing reference 36 pieces / 12.9 kg / 0.96 CUFT. MTBF estimates 2082.3 thousand hours minimum, Telcordia SR-332 (Bellcore); 234.5 thousand hours minimum, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue revision RPS-160-SPEC 2026-02-28; combined PDF pages 37–40. MTBF is a statistical reliability estimate under the stated methods, not a guaranteed service life.

    $104.98

  • RPS-75-48

    MEAN WELL RPS-75 series: Open-Frame Medical AC/DC Power Supply - RPS-75-48

    MEAN WELL RPS-75-48 is a 5 × 3-inch open-frame medical AC/DC power supply with a 48 V main output. The main-output current is 1.6 A with natural convection and 2.1 A with the specified 23.5 CFM airflow. Standard RPS-75 model with remote sense. It is intended for Class I equipment with protective grounding; BF applications require appropriate system consideration. Product Datasheet Download MEAN WELL RPS-75 Datasheet (PDF) The RPS-75 section is on PDF pages 33, 34, 35, 36. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPS-75-48 Configuration Standard RPS-75 model with remote sense. Board format 127 × 76.2 mm (5 × 3 inches); open-frame PCB construction. Intended applications Oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. Medical component approvals and isolation ratings do not certify the completed device. The equipment design must satisfy the applicable patient-protection, grounding, leakage-current and EMC requirements. Output Ratings and Cooling Conditions Nominal main output 48 V. Convection main-output current 0–1.6 A. Forced-air main-output current 0–2.1 A with at least 23.5 CFM as shown in the installation drawing. Convection rated power 76.8 W. Catalogue peak-load rating 100.8 W with 23.5 CFM forced air; use the temperature and input derating curves. Voltage adjustment 45.6–52.8 V for the main output. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±1.0%; includes set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.0%. Efficiency, typical 86%. The higher catalogue rating is tied to forced-air cooling. No pulse-duration or duty-cycle allowance is specified on these pages; do not substitute an unsupported transient-peak claim for the cooling requirements. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Input, Timing and Leakage Input range 90–264 VAC or 127–370 VDC; observe the low-input derating curve. Input frequency 47–63 Hz. AC current, typical 1.5 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 25 A at 115 VAC; 50 A at 230 VAC. Set-up and rise time 500 ms set-up at 230 VAC; 500 ms at 115 VAC; 30 ms rise at either input, at full load. Hold-up time, typical 90 ms at 230 VAC; 20 ms at 115 VAC, at full load. Earth leakage current Less than 150 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. No-load input power Less than 0.75 W. Switching-frequency reference 65 kHz in the block diagram. Protection Short circuit and overload 140–180% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage threshold 55.2–64.8 V. Overvoltage response Output shuts down; re-power to recover. Protection trip thresholds do not increase the usable output rating. Control and Monitoring Remote sense Available through CN3: pin 1 RS+, pin 2 RS−. The catalogue does not specify a maximum compensation voltage. Status indication LED1 is shown on the mechanical drawing. Temperature, Input Derating and Environment Working temperature −20 to +70°C with the applicable cooling and load restrictions. Horizontal-mounting temperature curve Convection: 100% of the convection rating from −20°C to 50°C, then derate to 50% at 70°C. The 23.5 CFM curve is marked 133% through 60°C, falling to 50% at 70°C; apply the exact model-specific forced-air current and power entries above. Input-voltage curve At 60 Hz, the graph permits 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes each along X, Y and Z. Operating altitude Up to 3,000 m. Above 2,000 m, reduce permitted ambient temperature by 3.5°C per additional 1,000 m for fanless operation, or 5°C per additional 1,000 m with a fan. Combine temperature, input-voltage and airflow restrictions. Do not interpret the maximum ambient temperature as a full-power rating. Installation and Mechanical Details Dimensions, L × W × H 127 × 76.2 × 31 mm. Mounting holes Four holes, diameter 3.8 mm; centre spacing 115.8 × 64.75 mm. Drawing references Edge-to-hole offsets are 5.6 mm and 5.7 mm as drawn. General dimensional tolerance ±1 mm; projection below the board 3 mm maximum. Forced-air arrangement At least 23.5 CFM; the drawing shows a fan 15 cm from the board edge, centred at the 63.5 mm longitudinal position, with airflow across the board in the indicated direction. Safety ground and chassis M1 is the safety-ground point. Secure electrical connections between M1, M2 and chassis ground for the specified installation and EMC performance. Heat sinks HS1, HS2 and HS3 must not be shorted together. On-board fuse marking T2.5/250V is shown on the AC fuse; this is a rating/designation, not a complete replacement ordering code. Follow the complete mechanical drawing and manufacturer installation manual. The catalogue does not specify mounting-screw torque, supplied mounting hardware or a complete fan ordering code. The indicated airflow arrangement is required for the corresponding higher-load rating. Compatible Connectors and Mating Parts AC input CN1 JST B3P-VH or equivalent; pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. DC output CN2 JST B8P-VH or equivalent; pins 1–4 +V, pins 5–8 −V. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Remote-sense CN3 JST B2B-XH or equivalent; pin 1 RS+, pin 2 RS−. Mating housing is printed as JST XHP; terminal JST SXH-001T-P0.6 or equivalent. The complete printed connector and terminal references above identify the documented interface parts. VHR and XHP are abbreviated housing-family references; Confirm the full housing/contact suffix and circuit count with the connector supplier before ordering. No unprinted suffix or inclusion in the power-supply package is implied. Safety, Isolation and EMC Listed medical approvals IEC60601-1:2005+A1+A2; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Other design reference BS EN/EN60335-1 is listed as a design reference by request, not an unconditional standard configuration approval. Patient-protection isolation Primary to secondary: 2 × MOPP; primary to earth: 1 × MOPP. System configuration Class I with FG. Suitable for BF applications with appropriate system consideration. Withstand voltage Input to output 4 kVAC; input to FG 2 kVAC; output to FG 1.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11), conducted and radiated Class B for Class I configuration. Harmonic current: BS EN/EN61000-3-2 Class A; flicker: BS EN/EN61000-3-3. Immunity framework BS EN/EN55035 and BS EN/EN60601-1-2. ESD BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF immunity BS EN/EN61000-4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9, 9–28 V/m at 385 MHz–5.78 GHz. EFT / burst and surge BS EN/EN61000-4-4: Level 3, 2 kV. BS EN/EN61000-4-5: Level 4, 4 kV line-to-FG and 2 kV line-to-line. Conducted and magnetic immunity BS EN/EN61000-4-6: Level 3, 10 V. BS EN/EN61000-4-8: Level 4, 30 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: 100% dip for 1 period, 30% dip for 25 periods, and 100% interruption for 250 periods. EMC testing used a 360 × 360 mm metal plate, 1 mm thick. This supply is an equipment component; EMC compliance must be confirmed again in the finished equipment. Weight, Reliability and Catalogue Reference Single-unit catalogue weight 260 g, from the explicit 0.26 kg per-unit PACKING entry. This is a catalogue reference, not a measured net or shipping weight. Packing reference 63 pieces / 16.3 kg / 1.28 CUFT. MTBF estimates 2837.6 thousand hours minimum, Telcordia SR-332 (Bellcore); 446.8 thousand hours minimum, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue revision RPS-75-SPEC 2024-11-22; combined PDF pages 33–36. Lifetime feature The family feature page states lifetime greater than 80,000 hours; it provides no operating-condition curve here. This is not an unconditional service-life guarantee. MTBF is a statistical reliability estimate under the stated methods, not a guaranteed service life.

  • RPS-75-36

    MEAN WELL RPS-75 series: Open-Frame Medical AC/DC Power Supply - RPS-75-36

    MEAN WELL RPS-75-36 is a 5 × 3-inch open-frame medical AC/DC power supply with a 36 V main output. The main-output current is 2.1 A with natural convection and 2.8 A with the specified 23.5 CFM airflow. Standard RPS-75 model with remote sense. It is intended for Class I equipment with protective grounding; BF applications require appropriate system consideration. Product Datasheet Download MEAN WELL RPS-75 Datasheet (PDF) The RPS-75 section is on PDF pages 33, 34, 35, 36. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPS-75-36 Configuration Standard RPS-75 model with remote sense. Board format 127 × 76.2 mm (5 × 3 inches); open-frame PCB construction. Intended applications Oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. Medical component approvals and isolation ratings do not certify the completed device. The equipment design must satisfy the applicable patient-protection, grounding, leakage-current and EMC requirements. Output Ratings and Cooling Conditions Nominal main output 36 V. Convection main-output current 0–2.1 A. Forced-air main-output current 0–2.8 A with at least 23.5 CFM as shown in the installation drawing. Convection rated power 75.6 W. Catalogue peak-load rating 100.8 W with 23.5 CFM forced air; use the temperature and input derating curves. Voltage adjustment 34.2–39.6 V for the main output. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±1.0%; includes set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.0%. Efficiency, typical 86%. The higher catalogue rating is tied to forced-air cooling. No pulse-duration or duty-cycle allowance is specified on these pages; do not substitute an unsupported transient-peak claim for the cooling requirements. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Input, Timing and Leakage Input range 90–264 VAC or 127–370 VDC; observe the low-input derating curve. Input frequency 47–63 Hz. AC current, typical 1.5 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 25 A at 115 VAC; 50 A at 230 VAC. Set-up and rise time 500 ms set-up at 230 VAC; 500 ms at 115 VAC; 30 ms rise at either input, at full load. Hold-up time, typical 90 ms at 230 VAC; 20 ms at 115 VAC, at full load. Earth leakage current Less than 150 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. No-load input power Less than 0.75 W. Switching-frequency reference 65 kHz in the block diagram. Protection Short circuit and overload 140–180% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage threshold 41.4–48.6 V. Overvoltage response Output shuts down; re-power to recover. Protection trip thresholds do not increase the usable output rating. Control and Monitoring Remote sense Available through CN3: pin 1 RS+, pin 2 RS−. The catalogue does not specify a maximum compensation voltage. Status indication LED1 is shown on the mechanical drawing. Temperature, Input Derating and Environment Working temperature −20 to +70°C with the applicable cooling and load restrictions. Horizontal-mounting temperature curve Convection: 100% of the convection rating from −20°C to 50°C, then derate to 50% at 70°C. The 23.5 CFM curve is marked 133% through 60°C, falling to 50% at 70°C; apply the exact model-specific forced-air current and power entries above. Input-voltage curve At 60 Hz, the graph permits 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes each along X, Y and Z. Operating altitude Up to 3,000 m. Above 2,000 m, reduce permitted ambient temperature by 3.5°C per additional 1,000 m for fanless operation, or 5°C per additional 1,000 m with a fan. Combine temperature, input-voltage and airflow restrictions. Do not interpret the maximum ambient temperature as a full-power rating. Installation and Mechanical Details Dimensions, L × W × H 127 × 76.2 × 31 mm. Mounting holes Four holes, diameter 3.8 mm; centre spacing 115.8 × 64.75 mm. Drawing references Edge-to-hole offsets are 5.6 mm and 5.7 mm as drawn. General dimensional tolerance ±1 mm; projection below the board 3 mm maximum. Forced-air arrangement At least 23.5 CFM; the drawing shows a fan 15 cm from the board edge, centred at the 63.5 mm longitudinal position, with airflow across the board in the indicated direction. Safety ground and chassis M1 is the safety-ground point. Secure electrical connections between M1, M2 and chassis ground for the specified installation and EMC performance. Heat sinks HS1, HS2 and HS3 must not be shorted together. On-board fuse marking T2.5/250V is shown on the AC fuse; this is a rating/designation, not a complete replacement ordering code. Follow the complete mechanical drawing and manufacturer installation manual. The catalogue does not specify mounting-screw torque, supplied mounting hardware or a complete fan ordering code. The indicated airflow arrangement is required for the corresponding higher-load rating. Compatible Connectors and Mating Parts AC input CN1 JST B3P-VH or equivalent; pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. DC output CN2 JST B8P-VH or equivalent; pins 1–4 +V, pins 5–8 −V. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Remote-sense CN3 JST B2B-XH or equivalent; pin 1 RS+, pin 2 RS−. Mating housing is printed as JST XHP; terminal JST SXH-001T-P0.6 or equivalent. The complete printed connector and terminal references above identify the documented interface parts. VHR and XHP are abbreviated housing-family references; Confirm the full housing/contact suffix and circuit count with the connector supplier before ordering. No unprinted suffix or inclusion in the power-supply package is implied. Safety, Isolation and EMC Listed medical approvals IEC60601-1:2005+A1+A2; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Other design reference BS EN/EN60335-1 is listed as a design reference by request, not an unconditional standard configuration approval. Patient-protection isolation Primary to secondary: 2 × MOPP; primary to earth: 1 × MOPP. System configuration Class I with FG. Suitable for BF applications with appropriate system consideration. Withstand voltage Input to output 4 kVAC; input to FG 2 kVAC; output to FG 1.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11), conducted and radiated Class B for Class I configuration. Harmonic current: BS EN/EN61000-3-2 Class A; flicker: BS EN/EN61000-3-3. Immunity framework BS EN/EN55035 and BS EN/EN60601-1-2. ESD BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF immunity BS EN/EN61000-4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9, 9–28 V/m at 385 MHz–5.78 GHz. EFT / burst and surge BS EN/EN61000-4-4: Level 3, 2 kV. BS EN/EN61000-4-5: Level 4, 4 kV line-to-FG and 2 kV line-to-line. Conducted and magnetic immunity BS EN/EN61000-4-6: Level 3, 10 V. BS EN/EN61000-4-8: Level 4, 30 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: 100% dip for 1 period, 30% dip for 25 periods, and 100% interruption for 250 periods. EMC testing used a 360 × 360 mm metal plate, 1 mm thick. This supply is an equipment component; EMC compliance must be confirmed again in the finished equipment. Weight, Reliability and Catalogue Reference Single-unit catalogue weight 260 g, from the explicit 0.26 kg per-unit PACKING entry. This is a catalogue reference, not a measured net or shipping weight. Packing reference 63 pieces / 16.3 kg / 1.28 CUFT. MTBF estimates 2837.6 thousand hours minimum, Telcordia SR-332 (Bellcore); 446.8 thousand hours minimum, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue revision RPS-75-SPEC 2024-11-22; combined PDF pages 33–36. Lifetime feature The family feature page states lifetime greater than 80,000 hours; it provides no operating-condition curve here. This is not an unconditional service-life guarantee. MTBF is a statistical reliability estimate under the stated methods, not a guaranteed service life.

  • RPS-75-24

    MEAN WELL RPS-75 series: Open-Frame Medical AC/DC Power Supply - RPS-75-24

    MEAN WELL RPS-75-24 is a 5 × 3-inch open-frame medical AC/DC power supply with a 24 V main output. The main-output current is 3.2 A with natural convection and 4.2 A with the specified 23.5 CFM airflow. Standard RPS-75 model with remote sense. It is intended for Class I equipment with protective grounding; BF applications require appropriate system consideration. Product Datasheet Download MEAN WELL RPS-75 Datasheet (PDF) The RPS-75 section is on PDF pages 33, 34, 35, 36. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPS-75-24 Configuration Standard RPS-75 model with remote sense. Board format 127 × 76.2 mm (5 × 3 inches); open-frame PCB construction. Intended applications Oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. Medical component approvals and isolation ratings do not certify the completed device. The equipment design must satisfy the applicable patient-protection, grounding, leakage-current and EMC requirements. Output Ratings and Cooling Conditions Nominal main output 24 V. Convection main-output current 0–3.2 A. Forced-air main-output current 0–4.2 A with at least 23.5 CFM as shown in the installation drawing. Convection rated power 76.8 W. Catalogue peak-load rating 100.8 W with 23.5 CFM forced air; use the temperature and input derating curves. Voltage adjustment 22.8–27.6 V for the main output. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±1.0%; includes set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.0%. Efficiency, typical 85%. The higher catalogue rating is tied to forced-air cooling. No pulse-duration or duty-cycle allowance is specified on these pages; do not substitute an unsupported transient-peak claim for the cooling requirements. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Input, Timing and Leakage Input range 90–264 VAC or 127–370 VDC; observe the low-input derating curve. Input frequency 47–63 Hz. AC current, typical 1.5 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 25 A at 115 VAC; 50 A at 230 VAC. Set-up and rise time 500 ms set-up at 230 VAC; 500 ms at 115 VAC; 30 ms rise at either input, at full load. Hold-up time, typical 90 ms at 230 VAC; 20 ms at 115 VAC, at full load. Earth leakage current Less than 150 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. No-load input power Less than 0.75 W. Switching-frequency reference 65 kHz in the block diagram. Protection Short circuit and overload 140–180% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage threshold 27.6–32.4 V. Overvoltage response Output shuts down; re-power to recover. Protection trip thresholds do not increase the usable output rating. Control and Monitoring Remote sense Available through CN3: pin 1 RS+, pin 2 RS−. The catalogue does not specify a maximum compensation voltage. Status indication LED1 is shown on the mechanical drawing. Temperature, Input Derating and Environment Working temperature −20 to +70°C with the applicable cooling and load restrictions. Horizontal-mounting temperature curve Convection: 100% of the convection rating from −20°C to 50°C, then derate to 50% at 70°C. The 23.5 CFM curve is marked 133% through 60°C, falling to 50% at 70°C; apply the exact model-specific forced-air current and power entries above. Input-voltage curve At 60 Hz, the graph permits 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes each along X, Y and Z. Operating altitude Up to 3,000 m. Above 2,000 m, reduce permitted ambient temperature by 3.5°C per additional 1,000 m for fanless operation, or 5°C per additional 1,000 m with a fan. Combine temperature, input-voltage and airflow restrictions. Do not interpret the maximum ambient temperature as a full-power rating. Installation and Mechanical Details Dimensions, L × W × H 127 × 76.2 × 31 mm. Mounting holes Four holes, diameter 3.8 mm; centre spacing 115.8 × 64.75 mm. Drawing references Edge-to-hole offsets are 5.6 mm and 5.7 mm as drawn. General dimensional tolerance ±1 mm; projection below the board 3 mm maximum. Forced-air arrangement At least 23.5 CFM; the drawing shows a fan 15 cm from the board edge, centred at the 63.5 mm longitudinal position, with airflow across the board in the indicated direction. Safety ground and chassis M1 is the safety-ground point. Secure electrical connections between M1, M2 and chassis ground for the specified installation and EMC performance. Heat sinks HS1, HS2 and HS3 must not be shorted together. On-board fuse marking T2.5/250V is shown on the AC fuse; this is a rating/designation, not a complete replacement ordering code. Follow the complete mechanical drawing and manufacturer installation manual. The catalogue does not specify mounting-screw torque, supplied mounting hardware or a complete fan ordering code. The indicated airflow arrangement is required for the corresponding higher-load rating. Compatible Connectors and Mating Parts AC input CN1 JST B3P-VH or equivalent; pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. DC output CN2 JST B8P-VH or equivalent; pins 1–4 +V, pins 5–8 −V. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Remote-sense CN3 JST B2B-XH or equivalent; pin 1 RS+, pin 2 RS−. Mating housing is printed as JST XHP; terminal JST SXH-001T-P0.6 or equivalent. The complete printed connector and terminal references above identify the documented interface parts. VHR and XHP are abbreviated housing-family references; Confirm the full housing/contact suffix and circuit count with the connector supplier before ordering. No unprinted suffix or inclusion in the power-supply package is implied. Safety, Isolation and EMC Listed medical approvals IEC60601-1:2005+A1+A2; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Other design reference BS EN/EN60335-1 is listed as a design reference by request, not an unconditional standard configuration approval. Patient-protection isolation Primary to secondary: 2 × MOPP; primary to earth: 1 × MOPP. System configuration Class I with FG. Suitable for BF applications with appropriate system consideration. Withstand voltage Input to output 4 kVAC; input to FG 2 kVAC; output to FG 1.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11), conducted and radiated Class B for Class I configuration. Harmonic current: BS EN/EN61000-3-2 Class A; flicker: BS EN/EN61000-3-3. Immunity framework BS EN/EN55035 and BS EN/EN60601-1-2. ESD BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF immunity BS EN/EN61000-4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9, 9–28 V/m at 385 MHz–5.78 GHz. EFT / burst and surge BS EN/EN61000-4-4: Level 3, 2 kV. BS EN/EN61000-4-5: Level 4, 4 kV line-to-FG and 2 kV line-to-line. Conducted and magnetic immunity BS EN/EN61000-4-6: Level 3, 10 V. BS EN/EN61000-4-8: Level 4, 30 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: 100% dip for 1 period, 30% dip for 25 periods, and 100% interruption for 250 periods. EMC testing used a 360 × 360 mm metal plate, 1 mm thick. This supply is an equipment component; EMC compliance must be confirmed again in the finished equipment. Weight, Reliability and Catalogue Reference Single-unit catalogue weight 260 g, from the explicit 0.26 kg per-unit PACKING entry. This is a catalogue reference, not a measured net or shipping weight. Packing reference 63 pieces / 16.3 kg / 1.28 CUFT. MTBF estimates 2837.6 thousand hours minimum, Telcordia SR-332 (Bellcore); 446.8 thousand hours minimum, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue revision RPS-75-SPEC 2024-11-22; combined PDF pages 33–36. Lifetime feature The family feature page states lifetime greater than 80,000 hours; it provides no operating-condition curve here. This is not an unconditional service-life guarantee. MTBF is a statistical reliability estimate under the stated methods, not a guaranteed service life.

  • RPS-75-15

    MEAN WELL RPS-75 series: Open-Frame Medical AC/DC Power Supply - RPS-75-15

    MEAN WELL RPS-75-15 is a 5 × 3-inch open-frame medical AC/DC power supply with a 15 V main output. The main-output current is 5 A with natural convection and 6.7 A with the specified 23.5 CFM airflow. Standard RPS-75 model with remote sense. It is intended for Class I equipment with protective grounding; BF applications require appropriate system consideration. Product Datasheet Download MEAN WELL RPS-75 Datasheet (PDF) The RPS-75 section is on PDF pages 33, 34, 35, 36. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPS-75-15 Configuration Standard RPS-75 model with remote sense. Board format 127 × 76.2 mm (5 × 3 inches); open-frame PCB construction. Intended applications Oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. Medical component approvals and isolation ratings do not certify the completed device. The equipment design must satisfy the applicable patient-protection, grounding, leakage-current and EMC requirements. Output Ratings and Cooling Conditions Nominal main output 15 V. Convection main-output current 0–5 A. Forced-air main-output current 0–6.7 A with at least 23.5 CFM as shown in the installation drawing. Convection rated power 75 W. Catalogue peak-load rating 100.5 W with 23.5 CFM forced air; use the temperature and input derating curves. Voltage adjustment 13.5–16.5 V for the main output. Ripple and noise, maximum 60 mVp-p. Voltage tolerance ±1.0%; includes set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.0%. Efficiency, typical 83%. The higher catalogue rating is tied to forced-air cooling. No pulse-duration or duty-cycle allowance is specified on these pages; do not substitute an unsupported transient-peak claim for the cooling requirements. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Input, Timing and Leakage Input range 90–264 VAC or 127–370 VDC; observe the low-input derating curve. Input frequency 47–63 Hz. AC current, typical 1.5 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 25 A at 115 VAC; 50 A at 230 VAC. Set-up and rise time 500 ms set-up at 230 VAC; 500 ms at 115 VAC; 30 ms rise at either input, at full load. Hold-up time, typical 90 ms at 230 VAC; 20 ms at 115 VAC, at full load. Earth leakage current Less than 150 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. No-load input power Less than 0.75 W. Switching-frequency reference 65 kHz in the block diagram. Protection Short circuit and overload 140–180% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage threshold 17.2–20.3 V. Overvoltage response Output shuts down; re-power to recover. Protection trip thresholds do not increase the usable output rating. Control and Monitoring Remote sense Available through CN3: pin 1 RS+, pin 2 RS−. The catalogue does not specify a maximum compensation voltage. Status indication LED1 is shown on the mechanical drawing. Temperature, Input Derating and Environment Working temperature −20 to +70°C with the applicable cooling and load restrictions. Horizontal-mounting temperature curve Convection: 100% of the convection rating from −20°C to 50°C, then derate to 50% at 70°C. The 23.5 CFM curve is marked 133% through 60°C, falling to 50% at 70°C; apply the exact model-specific forced-air current and power entries above. Input-voltage curve At 60 Hz, the graph permits 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes each along X, Y and Z. Operating altitude Up to 3,000 m. Above 2,000 m, reduce permitted ambient temperature by 3.5°C per additional 1,000 m for fanless operation, or 5°C per additional 1,000 m with a fan. Combine temperature, input-voltage and airflow restrictions. Do not interpret the maximum ambient temperature as a full-power rating. Installation and Mechanical Details Dimensions, L × W × H 127 × 76.2 × 31 mm. Mounting holes Four holes, diameter 3.8 mm; centre spacing 115.8 × 64.75 mm. Drawing references Edge-to-hole offsets are 5.6 mm and 5.7 mm as drawn. General dimensional tolerance ±1 mm; projection below the board 3 mm maximum. Forced-air arrangement At least 23.5 CFM; the drawing shows a fan 15 cm from the board edge, centred at the 63.5 mm longitudinal position, with airflow across the board in the indicated direction. Safety ground and chassis M1 is the safety-ground point. Secure electrical connections between M1, M2 and chassis ground for the specified installation and EMC performance. Heat sinks HS1, HS2 and HS3 must not be shorted together. On-board fuse marking T2.5/250V is shown on the AC fuse; this is a rating/designation, not a complete replacement ordering code. Follow the complete mechanical drawing and manufacturer installation manual. The catalogue does not specify mounting-screw torque, supplied mounting hardware or a complete fan ordering code. The indicated airflow arrangement is required for the corresponding higher-load rating. Compatible Connectors and Mating Parts AC input CN1 JST B3P-VH or equivalent; pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. DC output CN2 JST B8P-VH or equivalent; pins 1–4 +V, pins 5–8 −V. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Remote-sense CN3 JST B2B-XH or equivalent; pin 1 RS+, pin 2 RS−. Mating housing is printed as JST XHP; terminal JST SXH-001T-P0.6 or equivalent. The complete printed connector and terminal references above identify the documented interface parts. VHR and XHP are abbreviated housing-family references; Confirm the full housing/contact suffix and circuit count with the connector supplier before ordering. No unprinted suffix or inclusion in the power-supply package is implied. Safety, Isolation and EMC Listed medical approvals IEC60601-1:2005+A1+A2; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Other design reference BS EN/EN60335-1 is listed as a design reference by request, not an unconditional standard configuration approval. Patient-protection isolation Primary to secondary: 2 × MOPP; primary to earth: 1 × MOPP. System configuration Class I with FG. Suitable for BF applications with appropriate system consideration. Withstand voltage Input to output 4 kVAC; input to FG 2 kVAC; output to FG 1.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11), conducted and radiated Class B for Class I configuration. Harmonic current: BS EN/EN61000-3-2 Class A; flicker: BS EN/EN61000-3-3. Immunity framework BS EN/EN55035 and BS EN/EN60601-1-2. ESD BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF immunity BS EN/EN61000-4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9, 9–28 V/m at 385 MHz–5.78 GHz. EFT / burst and surge BS EN/EN61000-4-4: Level 3, 2 kV. BS EN/EN61000-4-5: Level 4, 4 kV line-to-FG and 2 kV line-to-line. Conducted and magnetic immunity BS EN/EN61000-4-6: Level 3, 10 V. BS EN/EN61000-4-8: Level 4, 30 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: 100% dip for 1 period, 30% dip for 25 periods, and 100% interruption for 250 periods. EMC testing used a 360 × 360 mm metal plate, 1 mm thick. This supply is an equipment component; EMC compliance must be confirmed again in the finished equipment. Weight, Reliability and Catalogue Reference Single-unit catalogue weight 260 g, from the explicit 0.26 kg per-unit PACKING entry. This is a catalogue reference, not a measured net or shipping weight. Packing reference 63 pieces / 16.3 kg / 1.28 CUFT. MTBF estimates 2837.6 thousand hours minimum, Telcordia SR-332 (Bellcore); 446.8 thousand hours minimum, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue revision RPS-75-SPEC 2024-11-22; combined PDF pages 33–36. Lifetime feature The family feature page states lifetime greater than 80,000 hours; it provides no operating-condition curve here. This is not an unconditional service-life guarantee. MTBF is a statistical reliability estimate under the stated methods, not a guaranteed service life.

  • RPS-75-12

    MEAN WELL RPS-75 series: Open-Frame Medical AC/DC Power Supply - RPS-75-12

    MEAN WELL RPS-75-12 is a 5 × 3-inch open-frame medical AC/DC power supply with a 12 V main output. The main-output current is 6.3 A with natural convection and 8.3 A with the specified 23.5 CFM airflow. Standard RPS-75 model with remote sense. It is intended for Class I equipment with protective grounding; BF applications require appropriate system consideration. Product Datasheet Download MEAN WELL RPS-75 Datasheet (PDF) The RPS-75 section is on PDF pages 33, 34, 35, 36. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPS-75-12 Configuration Standard RPS-75 model with remote sense. Board format 127 × 76.2 mm (5 × 3 inches); open-frame PCB construction. Intended applications Oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. Medical component approvals and isolation ratings do not certify the completed device. The equipment design must satisfy the applicable patient-protection, grounding, leakage-current and EMC requirements. Output Ratings and Cooling Conditions Nominal main output 12 V. Convection main-output current 0–6.3 A. Forced-air main-output current 0–8.3 A with at least 23.5 CFM as shown in the installation drawing. Convection rated power 75.6 W. Catalogue peak-load rating 99.6 W with 23.5 CFM forced air; use the temperature and input derating curves. Voltage adjustment 11.4–13.2 V for the main output. Ripple and noise, maximum 60 mVp-p. Voltage tolerance ±1.0%; includes set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.0%. Efficiency, typical 82%. The higher catalogue rating is tied to forced-air cooling. No pulse-duration or duty-cycle allowance is specified on these pages; do not substitute an unsupported transient-peak claim for the cooling requirements. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Input, Timing and Leakage Input range 90–264 VAC or 127–370 VDC; observe the low-input derating curve. Input frequency 47–63 Hz. AC current, typical 1.5 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 25 A at 115 VAC; 50 A at 230 VAC. Set-up and rise time 500 ms set-up at 230 VAC; 500 ms at 115 VAC; 30 ms rise at either input, at full load. Hold-up time, typical 90 ms at 230 VAC; 20 ms at 115 VAC, at full load. Earth leakage current Less than 150 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. No-load input power Less than 0.75 W. Switching-frequency reference 65 kHz in the block diagram. Protection Short circuit and overload 140–180% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage threshold 13.8–16.2 V. Overvoltage response Output shuts down; re-power to recover. Protection trip thresholds do not increase the usable output rating. Control and Monitoring Remote sense Available through CN3: pin 1 RS+, pin 2 RS−. The catalogue does not specify a maximum compensation voltage. Status indication LED1 is shown on the mechanical drawing. Temperature, Input Derating and Environment Working temperature −20 to +70°C with the applicable cooling and load restrictions. Horizontal-mounting temperature curve Convection: 100% of the convection rating from −20°C to 50°C, then derate to 50% at 70°C. The 23.5 CFM curve is marked 133% through 60°C, falling to 50% at 70°C; apply the exact model-specific forced-air current and power entries above. Input-voltage curve At 60 Hz, the graph permits 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes each along X, Y and Z. Operating altitude Up to 3,000 m. Above 2,000 m, reduce permitted ambient temperature by 3.5°C per additional 1,000 m for fanless operation, or 5°C per additional 1,000 m with a fan. Combine temperature, input-voltage and airflow restrictions. Do not interpret the maximum ambient temperature as a full-power rating. Installation and Mechanical Details Dimensions, L × W × H 127 × 76.2 × 31 mm. Mounting holes Four holes, diameter 3.8 mm; centre spacing 115.8 × 64.75 mm. Drawing references Edge-to-hole offsets are 5.6 mm and 5.7 mm as drawn. General dimensional tolerance ±1 mm; projection below the board 3 mm maximum. Forced-air arrangement At least 23.5 CFM; the drawing shows a fan 15 cm from the board edge, centred at the 63.5 mm longitudinal position, with airflow across the board in the indicated direction. Safety ground and chassis M1 is the safety-ground point. Secure electrical connections between M1, M2 and chassis ground for the specified installation and EMC performance. Heat sinks HS1, HS2 and HS3 must not be shorted together. On-board fuse marking T2.5/250V is shown on the AC fuse; this is a rating/designation, not a complete replacement ordering code. Follow the complete mechanical drawing and manufacturer installation manual. The catalogue does not specify mounting-screw torque, supplied mounting hardware or a complete fan ordering code. The indicated airflow arrangement is required for the corresponding higher-load rating. Compatible Connectors and Mating Parts AC input CN1 JST B3P-VH or equivalent; pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. DC output CN2 JST B8P-VH or equivalent; pins 1–4 +V, pins 5–8 −V. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Remote-sense CN3 JST B2B-XH or equivalent; pin 1 RS+, pin 2 RS−. Mating housing is printed as JST XHP; terminal JST SXH-001T-P0.6 or equivalent. The complete printed connector and terminal references above identify the documented interface parts. VHR and XHP are abbreviated housing-family references; Confirm the full housing/contact suffix and circuit count with the connector supplier before ordering. No unprinted suffix or inclusion in the power-supply package is implied. Safety, Isolation and EMC Listed medical approvals IEC60601-1:2005+A1+A2; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Other design reference BS EN/EN60335-1 is listed as a design reference by request, not an unconditional standard configuration approval. Patient-protection isolation Primary to secondary: 2 × MOPP; primary to earth: 1 × MOPP. System configuration Class I with FG. Suitable for BF applications with appropriate system consideration. Withstand voltage Input to output 4 kVAC; input to FG 2 kVAC; output to FG 1.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11), conducted and radiated Class B for Class I configuration. Harmonic current: BS EN/EN61000-3-2 Class A; flicker: BS EN/EN61000-3-3. Immunity framework BS EN/EN55035 and BS EN/EN60601-1-2. ESD BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF immunity BS EN/EN61000-4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9, 9–28 V/m at 385 MHz–5.78 GHz. EFT / burst and surge BS EN/EN61000-4-4: Level 3, 2 kV. BS EN/EN61000-4-5: Level 4, 4 kV line-to-FG and 2 kV line-to-line. Conducted and magnetic immunity BS EN/EN61000-4-6: Level 3, 10 V. BS EN/EN61000-4-8: Level 4, 30 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: 100% dip for 1 period, 30% dip for 25 periods, and 100% interruption for 250 periods. EMC testing used a 360 × 360 mm metal plate, 1 mm thick. This supply is an equipment component; EMC compliance must be confirmed again in the finished equipment. Weight, Reliability and Catalogue Reference Single-unit catalogue weight 260 g, from the explicit 0.26 kg per-unit PACKING entry. This is a catalogue reference, not a measured net or shipping weight. Packing reference 63 pieces / 16.3 kg / 1.28 CUFT. MTBF estimates 2837.6 thousand hours minimum, Telcordia SR-332 (Bellcore); 446.8 thousand hours minimum, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue revision RPS-75-SPEC 2024-11-22; combined PDF pages 33–36. Lifetime feature The family feature page states lifetime greater than 80,000 hours; it provides no operating-condition curve here. This is not an unconditional service-life guarantee. MTBF is a statistical reliability estimate under the stated methods, not a guaranteed service life.

  • RPS-75-5

    MEAN WELL RPS-75 series: Open-Frame Medical AC/DC Power Supply - RPS-75-5

    MEAN WELL RPS-75-5 is a 5 × 3-inch open-frame medical AC/DC power supply with a 5 V main output. The main-output current is 14 A with natural convection and 18.7 A with the specified 23.5 CFM airflow. Standard RPS-75 model with remote sense. It is intended for Class I equipment with protective grounding; BF applications require appropriate system consideration. Product Datasheet Download MEAN WELL RPS-75 Datasheet (PDF) The RPS-75 section is on PDF pages 33, 34, 35, 36. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPS-75-5 Configuration Standard RPS-75 model with remote sense. Board format 127 × 76.2 mm (5 × 3 inches); open-frame PCB construction. Intended applications Oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. Medical component approvals and isolation ratings do not certify the completed device. The equipment design must satisfy the applicable patient-protection, grounding, leakage-current and EMC requirements. Output Ratings and Cooling Conditions Nominal main output 5 V. Convection main-output current 0–14 A. Forced-air main-output current 0–18.7 A with at least 23.5 CFM as shown in the installation drawing. Convection rated power 70 W. Catalogue peak-load rating 93.5 W with 23.5 CFM forced air; use the temperature and input derating curves. Voltage adjustment 4.75–5.5 V for the main output. Ripple and noise, maximum 60 mVp-p. Voltage tolerance ±2.0%; includes set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.5%. Efficiency, typical 78%. The higher catalogue rating is tied to forced-air cooling. No pulse-duration or duty-cycle allowance is specified on these pages; do not substitute an unsupported transient-peak claim for the cooling requirements. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Input, Timing and Leakage Input range 90–264 VAC or 127–370 VDC; observe the low-input derating curve. Input frequency 47–63 Hz. AC current, typical 1.5 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 25 A at 115 VAC; 50 A at 230 VAC. Set-up and rise time 500 ms set-up at 230 VAC; 500 ms at 115 VAC; 30 ms rise at either input, at full load. Hold-up time, typical 90 ms at 230 VAC; 20 ms at 115 VAC, at full load. Earth leakage current Less than 150 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. No-load input power Less than 0.75 W. Switching-frequency reference 65 kHz in the block diagram. Protection Short circuit and overload 140–180% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage threshold 5.7–6.8 V. Overvoltage response Output shuts down; re-power to recover. Protection trip thresholds do not increase the usable output rating. Control and Monitoring Remote sense Available through CN3: pin 1 RS+, pin 2 RS−. The catalogue does not specify a maximum compensation voltage. Status indication LED1 is shown on the mechanical drawing. Temperature, Input Derating and Environment Working temperature −20 to +70°C with the applicable cooling and load restrictions. Horizontal-mounting temperature curve Convection: 100% of the convection rating from −20°C to 40°C, then derate to 50% at 70°C. The 23.5 CFM curve is marked 133% through 60°C, falling to 50% at 70°C; apply the exact model-specific forced-air current and power entries above. Input-voltage curve At 60 Hz, the graph permits 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes each along X, Y and Z. Operating altitude Up to 3,000 m. Above 2,000 m, reduce permitted ambient temperature by 3.5°C per additional 1,000 m for fanless operation, or 5°C per additional 1,000 m with a fan. Combine temperature, input-voltage and airflow restrictions. Do not interpret the maximum ambient temperature as a full-power rating. Installation and Mechanical Details Dimensions, L × W × H 127 × 76.2 × 31 mm. Mounting holes Four holes, diameter 3.8 mm; centre spacing 115.8 × 64.75 mm. Drawing references Edge-to-hole offsets are 5.6 mm and 5.7 mm as drawn. General dimensional tolerance ±1 mm; projection below the board 3 mm maximum. Forced-air arrangement At least 23.5 CFM; the drawing shows a fan 15 cm from the board edge, centred at the 63.5 mm longitudinal position, with airflow across the board in the indicated direction. Safety ground and chassis M1 is the safety-ground point. Secure electrical connections between M1, M2 and chassis ground for the specified installation and EMC performance. Heat sinks HS1, HS2 and HS3 must not be shorted together. On-board fuse marking T2.5/250V is shown on the AC fuse; this is a rating/designation, not a complete replacement ordering code. Follow the complete mechanical drawing and manufacturer installation manual. The catalogue does not specify mounting-screw torque, supplied mounting hardware or a complete fan ordering code. The indicated airflow arrangement is required for the corresponding higher-load rating. Compatible Connectors and Mating Parts AC input CN1 JST B3P-VH or equivalent; pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. DC output CN2 JST B8P-VH or equivalent; pins 1–4 +V, pins 5–8 −V. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Remote-sense CN3 JST B2B-XH or equivalent; pin 1 RS+, pin 2 RS−. Mating housing is printed as JST XHP; terminal JST SXH-001T-P0.6 or equivalent. The complete printed connector and terminal references above identify the documented interface parts. VHR and XHP are abbreviated housing-family references; Confirm the full housing/contact suffix and circuit count with the connector supplier before ordering. No unprinted suffix or inclusion in the power-supply package is implied. Safety, Isolation and EMC Listed medical approvals IEC60601-1:2005+A1+A2; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Other design reference BS EN/EN60335-1 is listed as a design reference by request, not an unconditional standard configuration approval. Patient-protection isolation Primary to secondary: 2 × MOPP; primary to earth: 1 × MOPP. System configuration Class I with FG. Suitable for BF applications with appropriate system consideration. Withstand voltage Input to output 4 kVAC; input to FG 2 kVAC; output to FG 1.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11), conducted and radiated Class B for Class I configuration. Harmonic current: BS EN/EN61000-3-2 Class A; flicker: BS EN/EN61000-3-3. Immunity framework BS EN/EN55035 and BS EN/EN60601-1-2. ESD BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF immunity BS EN/EN61000-4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9, 9–28 V/m at 385 MHz–5.78 GHz. EFT / burst and surge BS EN/EN61000-4-4: Level 3, 2 kV. BS EN/EN61000-4-5: Level 4, 4 kV line-to-FG and 2 kV line-to-line. Conducted and magnetic immunity BS EN/EN61000-4-6: Level 3, 10 V. BS EN/EN61000-4-8: Level 4, 30 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: 100% dip for 1 period, 30% dip for 25 periods, and 100% interruption for 250 periods. EMC testing used a 360 × 360 mm metal plate, 1 mm thick. This supply is an equipment component; EMC compliance must be confirmed again in the finished equipment. Weight, Reliability and Catalogue Reference Single-unit catalogue weight 260 g, from the explicit 0.26 kg per-unit PACKING entry. This is a catalogue reference, not a measured net or shipping weight. Packing reference 63 pieces / 16.3 kg / 1.28 CUFT. MTBF estimates 2837.6 thousand hours minimum, Telcordia SR-332 (Bellcore); 446.8 thousand hours minimum, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue revision RPS-75-SPEC 2024-11-22; combined PDF pages 33–36. Lifetime feature The family feature page states lifetime greater than 80,000 hours; it provides no operating-condition curve here. This is not an unconditional service-life guarantee. MTBF is a statistical reliability estimate under the stated methods, not a guaranteed service life.

  • RPS-75-3.3

    MEAN WELL RPS-75 series: Open-Frame Medical AC/DC Power Supply - RPS-75-3.3

    MEAN WELL RPS-75-3.3 is a 5 × 3-inch open-frame medical AC/DC power supply with a 3.3 V main output. The main-output current is 15 A with natural convection and 20 A with the specified 23.5 CFM airflow. Standard RPS-75 model with remote sense. It is intended for Class I equipment with protective grounding; BF applications require appropriate system consideration. Product Datasheet Download MEAN WELL RPS-75 Datasheet (PDF) The RPS-75 section is on PDF pages 33, 34, 35, 36. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPS-75-3.3 Configuration Standard RPS-75 model with remote sense. Board format 127 × 76.2 mm (5 × 3 inches); open-frame PCB construction. Intended applications Oral irrigators, hemodialysis equipment, medical monitors and sleep-apnea devices. Medical component approvals and isolation ratings do not certify the completed device. The equipment design must satisfy the applicable patient-protection, grounding, leakage-current and EMC requirements. Output Ratings and Cooling Conditions Nominal main output 3.3 V. Convection main-output current 0–15 A. Forced-air main-output current 0–20 A with at least 23.5 CFM as shown in the installation drawing. Convection rated power 49.5 W. Catalogue peak-load rating 66 W with 23.5 CFM forced air; use the temperature and input derating curves. Voltage adjustment 2.9–3.6 V for the main output. Ripple and noise, maximum 60 mVp-p. Voltage tolerance ±2.0%; includes set-up tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.5%. Efficiency, typical 73%. The higher catalogue rating is tied to forced-air cooling. No pulse-duration or duty-cycle allowance is specified on these pages; do not substitute an unsupported transient-peak claim for the cooling requirements. Unless otherwise stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Ripple/noise uses 20 MHz bandwidth and a 12-inch twisted pair terminated by parallel 0.1 µF and 47 µF capacitors. Input, Timing and Leakage Input range 90–264 VAC or 127–370 VDC; observe the low-input derating curve. Input frequency 47–63 Hz. AC current, typical 1.5 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 25 A at 115 VAC; 50 A at 230 VAC. Set-up and rise time 500 ms set-up at 230 VAC; 500 ms at 115 VAC; 30 ms rise at either input, at full load. Hold-up time, typical 90 ms at 230 VAC; 20 ms at 115 VAC, at full load. Earth leakage current Less than 150 µA at 264 VAC. Touch current Less than 100 µA at 264 VAC, measured from primary input to DC output. No-load input power Less than 0.75 W. Switching-frequency reference 65 kHz in the block diagram. Protection Short circuit and overload 140–180% of rated output power; hiccup mode automatically recovers after the fault is removed. Overvoltage threshold 3.8–4.5 V. Overvoltage response Output shuts down; re-power to recover. Protection trip thresholds do not increase the usable output rating. Control and Monitoring Remote sense Available through CN3: pin 1 RS+, pin 2 RS−. The catalogue does not specify a maximum compensation voltage. Status indication LED1 is shown on the mechanical drawing. Temperature, Input Derating and Environment Working temperature −20 to +70°C with the applicable cooling and load restrictions. Horizontal-mounting temperature curve Convection: 100% of the convection rating from −20°C to 40°C, then derate to 50% at 70°C. The 23.5 CFM curve is marked 133% through 60°C, falling to 50% at 70°C; apply the exact model-specific forced-air current and power entries above. Input-voltage curve At 60 Hz, the graph permits 80% load at 90 VAC, rising to 100% at 100 VAC and remaining at 100% through 264 VAC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G, 10 minutes per cycle; 60 minutes each along X, Y and Z. Operating altitude Up to 3,000 m. Above 2,000 m, reduce permitted ambient temperature by 3.5°C per additional 1,000 m for fanless operation, or 5°C per additional 1,000 m with a fan. Combine temperature, input-voltage and airflow restrictions. Do not interpret the maximum ambient temperature as a full-power rating. Installation and Mechanical Details Dimensions, L × W × H 127 × 76.2 × 31 mm. Mounting holes Four holes, diameter 3.8 mm; centre spacing 115.8 × 64.75 mm. Drawing references Edge-to-hole offsets are 5.6 mm and 5.7 mm as drawn. General dimensional tolerance ±1 mm; projection below the board 3 mm maximum. Forced-air arrangement At least 23.5 CFM; the drawing shows a fan 15 cm from the board edge, centred at the 63.5 mm longitudinal position, with airflow across the board in the indicated direction. Safety ground and chassis M1 is the safety-ground point. Secure electrical connections between M1, M2 and chassis ground for the specified installation and EMC performance. Heat sinks HS1, HS2 and HS3 must not be shorted together. On-board fuse marking T2.5/250V is shown on the AC fuse; this is a rating/designation, not a complete replacement ordering code. Follow the complete mechanical drawing and manufacturer installation manual. The catalogue does not specify mounting-screw torque, supplied mounting hardware or a complete fan ordering code. The indicated airflow arrangement is required for the corresponding higher-load rating. Compatible Connectors and Mating Parts AC input CN1 JST B3P-VH or equivalent; pin 1 AC/N, pin 2 absent, pin 3 AC/L. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. DC output CN2 JST B8P-VH or equivalent; pins 1–4 +V, pins 5–8 −V. Mating housing is printed as JST VHR; terminal JST SVH-21T-P1.1 or equivalent. Remote-sense CN3 JST B2B-XH or equivalent; pin 1 RS+, pin 2 RS−. Mating housing is printed as JST XHP; terminal JST SXH-001T-P0.6 or equivalent. The complete printed connector and terminal references above identify the documented interface parts. VHR and XHP are abbreviated housing-family references; Confirm the full housing/contact suffix and circuit count with the connector supplier before ordering. No unprinted suffix or inclusion in the power-supply package is implied. Safety, Isolation and EMC Listed medical approvals IEC60601-1:2005+A1+A2; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Other design reference BS EN/EN60335-1 is listed as a design reference by request, not an unconditional standard configuration approval. Patient-protection isolation Primary to secondary: 2 × MOPP; primary to earth: 1 × MOPP. System configuration Class I with FG. Suitable for BF applications with appropriate system consideration. Withstand voltage Input to output 4 kVAC; input to FG 2 kVAC; output to FG 1.5 kVAC. Insulation resistance Input/output, input/FG and output/FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions BS EN/EN55011 (CISPR11), conducted and radiated Class B for Class I configuration. Harmonic current: BS EN/EN61000-3-2 Class A; flicker: BS EN/EN61000-3-3. Immunity framework BS EN/EN55035 and BS EN/EN60601-1-2. ESD BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF immunity BS EN/EN61000-4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9, 9–28 V/m at 385 MHz–5.78 GHz. EFT / burst and surge BS EN/EN61000-4-4: Level 3, 2 kV. BS EN/EN61000-4-5: Level 4, 4 kV line-to-FG and 2 kV line-to-line. Conducted and magnetic immunity BS EN/EN61000-4-6: Level 3, 10 V. BS EN/EN61000-4-8: Level 4, 30 A/m. Voltage dips and interruptions BS EN/EN61000-4-11: 100% dip for 1 period, 30% dip for 25 periods, and 100% interruption for 250 periods. EMC testing used a 360 × 360 mm metal plate, 1 mm thick. This supply is an equipment component; EMC compliance must be confirmed again in the finished equipment. Weight, Reliability and Catalogue Reference Single-unit catalogue weight 260 g, from the explicit 0.26 kg per-unit PACKING entry. This is a catalogue reference, not a measured net or shipping weight. Packing reference 63 pieces / 16.3 kg / 1.28 CUFT. MTBF estimates 2837.6 thousand hours minimum, Telcordia SR-332 (Bellcore); 446.8 thousand hours minimum, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to applicable manufacturer terms. Catalogue revision RPS-75-SPEC 2024-11-22; combined PDF pages 33–36. Lifetime feature The family feature page states lifetime greater than 80,000 hours; it provides no operating-condition curve here. This is not an unconditional service-life guarantee. MTBF is a statistical reliability estimate under the stated methods, not a guaranteed service life.

  • RPS-200-48-C

    MEAN WELL RPS-200 series: Enclosed Medical AC/DC Power Supply - RPS-200-48-C

    MEAN WELL RPS-200-48-C is an enclosed medical AC/DC supply with 48 V output. It delivers 144 W by convection and 201.6 W with 10 CFM forced air. Apply the load, thermal and system-integration conditions below. Product Datasheet Download MEAN WELL RPS-200 Datasheet (PDF) The RPS-200 section is on PDF pages 27, 28, 29, 30, 31, 32. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPS-200-48-C. Series and construction RPS-200 medical AC/DC power supply; enclosed casing, -C option. Voltage code 48 specifies the nominal DC output voltage. System class Use in a Class I system with FG; the -C enclosed type is not suitable for a Class II system without FG. Medical application Primary-to-secondary 2 MOPP. Suitable for BF applications only with appropriate system consideration; final equipment compliance remains an integration requirement. Catalogue applications include oral irrigators, hemodialysis machines, medical monitors, sleep-apnea devices and pumps. Electric beds are also listed for this series. DC Output and Load Conditions Nominal output 48 V. Convection rating 3 A; catalogue-rated 144 W. 10 CFM forced air rating 4.2 A; catalogue-rated 201.6 W. Adjustment range 45.6–50.4 V, using SVR1. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±1.0%; includes setup tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.0%. Efficiency, typical 95%. The higher rating requires 10 CFM forced airflow. The convection rating applies without that forced airflow; do not treat the two ratings as interchangeable. Do not exceed the applicable voltage, current or catalogue-rated power limit. Combine the cooling, input-voltage and ambient-temperature limits. Ripple is measured at 20 MHz with a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Input, Start-Up and Consumption Input range 80–264 VAC or 113–370 VDC; low-input derating applies. Frequency 47–63 Hz. AC input current, typical 2 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 60 A at 230 VAC. No-load consumption Less than 0.5 W. Set-up and rise 700 ms setup and 30 ms rise at both 230 VAC and 115 VAC, full load. Hold-up, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load. Leakage at 264 VAC Earth leakage <180 µA; touch current <40 µA. Touch current is measured from primary input to DC output. Switching-frequency diagram 65 kHz. Power factor Built-in active PFC; PF >0.94 at 230 VAC and >0.98 at 115 VAC, full load. Unless separately stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Protection Short circuit and overload Short-circuit protection is listed. Overload operates at 110–140% of rated output power; hiccup mode recovers automatically after the fault is removed. Overvoltage threshold 52.8–62.4 V. Overvoltage response Output shuts down; re-power on to recover. Overtemperature response Output shuts down. Re-power on to recover. Cooling and Derating Ambient range −30 to +70°C, with derating; horizontal mounting. Convection temperature curve The graph shows 70% load from −30 to 45°C, falling to 40% at 70°C. Use the model-specific convection current and wattage above. Input-voltage curve, 60 Hz 80 VAC: 70%; 115 VAC: 100%, maintained to 264 VAC. The curve is explicitly for 10 CFM operation. 10 CFM temperature curve 100% load from −30 to 50°C, falling to 40% at 70°C. Fan arrangement The mechanical drawing positions an external 10 CFM fan 5 cm from the assembly in the indicated airflow direction; preserve that airflow path. A fan is not claimed as supplied. Use the complete plotted curves for intermediate conditions; the maximum ambient temperature is a derated point. Apply the most restrictive simultaneous limit. Environment Operating humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude 5,000 m. High-altitude derating Above 2,000 m, reduce allowed ambient temperature by 3.5°C per 1,000 m for fanless operation or 5°C per 1,000 m for fan-cooled operation. Dimensions and Installation Dimensions, L × W × H 103.4 × 62 × 40 mm. General drawing tolerance ±1 mm. Mounting geometry Case No. 245A. Side drawing: 2-M3 L=4, spacing 78 mm; bottom: 2-M3 L=2, spacing 55 mm. Side mounting notches are marked 2-R1.75. Follow the complete drawing for positions and permitted engagement. Adjustment Use SVR1 within the stated voltage-adjustment range. Indicator The mechanical drawing identifies an LED power indicator. Follow the manufacturer’s installation manual and the model-specific drawing. No separate mounting-kit ordering code is listed in these assigned pages. Input and Output Connectors AC input CN1 JST B3P-VH or equivalent; pin 1: AC/L, pin 2: No pin, pin 3: AC/N. DC output CN2 JST B6P-VH or equivalent; pins 1, 2, 3 are +V; pins 4, 5, 6 are −V. Input/output mating housing JST VHR or equivalent, exactly the family designation printed in the sheet. Select the matching circuit count; no complete housing suffix is supplied here. Input/output contact JST SVH-21T-P1.1 or equivalent. Connector references identify compatible interfaces, not an included loose cable or accessory kit. Confirm fit and ratings for an equivalent component. Fan Supply and Connector Fan output 12 V at 0.5 A for the cooling fan only. Specified tolerance ±15% at 20% of the main-output rated current under 10 CFM conditions. CN101 JST B2B-PH-K-S or equivalent; pin 1: +12 V, pin 2: DC COM. Mating housing JST PHR-2 or equivalent. Contact JST SPH-002T-P0.5S or equivalent. This output is intended to power the additional external fan for cooling and full-load delivery. Do not use it to drive other devices. Safety and EMC Safety approvals IEC60601-1:2005+A1+A2; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. BS EN/EN60335-1 is a design reference by request, not an unconditional approval. Isolation barriers Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance I/P–O/P, I/P–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions, BS EN/EN55011 (CISPR11) Conducted Class B; radiated Class B with FG in Class I, or Class A without FG in Class II for the PCB type. The enclosed -C type is not suitable for Class II. Harmonics and flicker BS EN/EN61000-3-2 Class A; BS EN/EN61000-3-3 listed. Immunity framework BS EN/EN55035 and BS EN/EN60601-1-2. ESD, IEC/EN61000-4-2 Level 4: 15 kV air and 8 kV contact. RF field, IEC/EN61000-4-3 Level 3: 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT, IEC/EN61000-4-4 Level 3, 2 kV. Surge, IEC/EN61000-4-5 Level 4: 4 kV line–FG; 2 kV line–line. Conducted immunity, IEC/EN61000-4-6 Level 3, 10 V. Magnetic field, IEC/EN61000-4-8 Level 4, 30 A/m. Voltage dips and interruptions, IEC/EN61000-4-11 100% dip for 1 period; 30% dip for 25 periods; 100% interruption for 250 periods. EMC testing uses a 360 × 360 × 1 mm metal plate. This supply is a component for installation in final equipment; the complete equipment must be reconfirmed for EMC and applicable medical-system safety. Weight and Catalogue Reference Single-unit catalogue weight 300 g (0.3 kg), explicitly listed in PACKING; a catalogue reference rather than measured shipment weight. Packing 60 pieces / 19 kg / 1.06 CUFT. Minimum MTBF estimates 2669.7 thousand hours, Telcordia SR-332 (Bellcore); 500.3 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to the applicable manufacturer terms. Catalogue version RPS-200-SPEC 2026-02-28; combined PDF pages 27–32. Lifetime feature The family feature page states lifetime greater than 65,000 hours; it does not state the test conditions there. This is distinct from the MTBF estimates. Family power-density claim The family introduction states up to 21.9 W/in³; this is not an individual configuration measurement. MTBF is a statistical estimate under the listed methods, not a guaranteed service life.

    $125.19

  • RPS-200-27-C

    MEAN WELL RPS-200 series: Enclosed Medical AC/DC Power Supply - RPS-200-27-C

    MEAN WELL RPS-200-27-C is an enclosed medical AC/DC supply with 27 V output. It delivers 143.1 W by convection and 202.5 W with 10 CFM forced air. Apply the load, thermal and system-integration conditions below. Product Datasheet Download MEAN WELL RPS-200 Datasheet (PDF) The RPS-200 section is on PDF pages 27, 28, 29, 30, 31, 32. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPS-200-27-C. Series and construction RPS-200 medical AC/DC power supply; enclosed casing, -C option. Voltage code 27 specifies the nominal DC output voltage. System class Use in a Class I system with FG; the -C enclosed type is not suitable for a Class II system without FG. Medical application Primary-to-secondary 2 MOPP. Suitable for BF applications only with appropriate system consideration; final equipment compliance remains an integration requirement. Catalogue applications include oral irrigators, hemodialysis machines, medical monitors, sleep-apnea devices and pumps. Electric beds are also listed for this series. DC Output and Load Conditions Nominal output 27 V. Convection rating 5.3 A; catalogue-rated 143.1 W. 10 CFM forced air rating 7.5 A; catalogue-rated 202.5 W. Adjustment range 25.6–28.4 V, using SVR1. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±1.0%; includes setup tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.0%. Efficiency, typical 94%. The higher rating requires 10 CFM forced airflow. The convection rating applies without that forced airflow; do not treat the two ratings as interchangeable. Do not exceed the applicable voltage, current or catalogue-rated power limit. Combine the cooling, input-voltage and ambient-temperature limits. Ripple is measured at 20 MHz with a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Input, Start-Up and Consumption Input range 80–264 VAC or 113–370 VDC; low-input derating applies. Frequency 47–63 Hz. AC input current, typical 2 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 60 A at 230 VAC. No-load consumption Less than 0.5 W. Set-up and rise 700 ms setup and 30 ms rise at both 230 VAC and 115 VAC, full load. Hold-up, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load. Leakage at 264 VAC Earth leakage <180 µA; touch current <40 µA. Touch current is measured from primary input to DC output. Switching-frequency diagram 65 kHz. Power factor Built-in active PFC; PF >0.94 at 230 VAC and >0.98 at 115 VAC, full load. Unless separately stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Protection Short circuit and overload Short-circuit protection is listed. Overload operates at 110–140% of rated output power; hiccup mode recovers automatically after the fault is removed. Overvoltage threshold 29.7–35 V. Overvoltage response Output shuts down; re-power on to recover. Overtemperature response Output shuts down. Re-power on to recover. Cooling and Derating Ambient range −30 to +70°C, with derating; horizontal mounting. Convection temperature curve The graph shows 70% load from −30 to 45°C, falling to 40% at 70°C. Use the model-specific convection current and wattage above. Input-voltage curve, 60 Hz 80 VAC: 70%; 115 VAC: 100%, maintained to 264 VAC. The curve is explicitly for 10 CFM operation. 10 CFM temperature curve 100% load from −30 to 50°C, falling to 40% at 70°C. Fan arrangement The mechanical drawing positions an external 10 CFM fan 5 cm from the assembly in the indicated airflow direction; preserve that airflow path. A fan is not claimed as supplied. Use the complete plotted curves for intermediate conditions; the maximum ambient temperature is a derated point. Apply the most restrictive simultaneous limit. Environment Operating humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude 5,000 m. High-altitude derating Above 2,000 m, reduce allowed ambient temperature by 3.5°C per 1,000 m for fanless operation or 5°C per 1,000 m for fan-cooled operation. Dimensions and Installation Dimensions, L × W × H 103.4 × 62 × 40 mm. General drawing tolerance ±1 mm. Mounting geometry Case No. 245A. Side drawing: 2-M3 L=4, spacing 78 mm; bottom: 2-M3 L=2, spacing 55 mm. Side mounting notches are marked 2-R1.75. Follow the complete drawing for positions and permitted engagement. Adjustment Use SVR1 within the stated voltage-adjustment range. Indicator The mechanical drawing identifies an LED power indicator. Follow the manufacturer’s installation manual and the model-specific drawing. No separate mounting-kit ordering code is listed in these assigned pages. Input and Output Connectors AC input CN1 JST B3P-VH or equivalent; pin 1: AC/L, pin 2: No pin, pin 3: AC/N. DC output CN2 JST B6P-VH or equivalent; pins 1, 2, 3 are +V; pins 4, 5, 6 are −V. Input/output mating housing JST VHR or equivalent, exactly the family designation printed in the sheet. Select the matching circuit count; no complete housing suffix is supplied here. Input/output contact JST SVH-21T-P1.1 or equivalent. Connector references identify compatible interfaces, not an included loose cable or accessory kit. Confirm fit and ratings for an equivalent component. Fan Supply and Connector Fan output 12 V at 0.5 A for the cooling fan only. Specified tolerance ±15% at 20% of the main-output rated current under 10 CFM conditions. CN101 JST B2B-PH-K-S or equivalent; pin 1: +12 V, pin 2: DC COM. Mating housing JST PHR-2 or equivalent. Contact JST SPH-002T-P0.5S or equivalent. This output is intended to power the additional external fan for cooling and full-load delivery. Do not use it to drive other devices. Safety and EMC Safety approvals IEC60601-1:2005+A1+A2; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. BS EN/EN60335-1 is a design reference by request, not an unconditional approval. Isolation barriers Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance I/P–O/P, I/P–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions, BS EN/EN55011 (CISPR11) Conducted Class B; radiated Class B with FG in Class I, or Class A without FG in Class II for the PCB type. The enclosed -C type is not suitable for Class II. Harmonics and flicker BS EN/EN61000-3-2 Class A; BS EN/EN61000-3-3 listed. Immunity framework BS EN/EN55035 and BS EN/EN60601-1-2. ESD, IEC/EN61000-4-2 Level 4: 15 kV air and 8 kV contact. RF field, IEC/EN61000-4-3 Level 3: 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT, IEC/EN61000-4-4 Level 3, 2 kV. Surge, IEC/EN61000-4-5 Level 4: 4 kV line–FG; 2 kV line–line. Conducted immunity, IEC/EN61000-4-6 Level 3, 10 V. Magnetic field, IEC/EN61000-4-8 Level 4, 30 A/m. Voltage dips and interruptions, IEC/EN61000-4-11 100% dip for 1 period; 30% dip for 25 periods; 100% interruption for 250 periods. EMC testing uses a 360 × 360 × 1 mm metal plate. This supply is a component for installation in final equipment; the complete equipment must be reconfirmed for EMC and applicable medical-system safety. Weight and Catalogue Reference Single-unit catalogue weight 300 g (0.3 kg), explicitly listed in PACKING; a catalogue reference rather than measured shipment weight. Packing 60 pieces / 19 kg / 1.06 CUFT. Minimum MTBF estimates 2669.7 thousand hours, Telcordia SR-332 (Bellcore); 500.3 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to the applicable manufacturer terms. Catalogue version RPS-200-SPEC 2026-02-28; combined PDF pages 27–32. Lifetime feature The family feature page states lifetime greater than 65,000 hours; it does not state the test conditions there. This is distinct from the MTBF estimates. Family power-density claim The family introduction states up to 21.9 W/in³; this is not an individual configuration measurement. MTBF is a statistical estimate under the listed methods, not a guaranteed service life.

    $125.19

  • RPS-200-24-C

    MEAN WELL RPS-200 series: Enclosed Medical AC/DC Power Supply - RPS-200-24-C

    MEAN WELL RPS-200-24-C is an enclosed medical AC/DC supply with 24 V output. It delivers 141.6 W by convection and 201.6 W with 10 CFM forced air. Apply the load, thermal and system-integration conditions below. Product Datasheet Download MEAN WELL RPS-200 Datasheet (PDF) The RPS-200 section is on PDF pages 27, 28, 29, 30, 31, 32. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPS-200-24-C. Series and construction RPS-200 medical AC/DC power supply; enclosed casing, -C option. Voltage code 24 specifies the nominal DC output voltage. System class Use in a Class I system with FG; the -C enclosed type is not suitable for a Class II system without FG. Medical application Primary-to-secondary 2 MOPP. Suitable for BF applications only with appropriate system consideration; final equipment compliance remains an integration requirement. Catalogue applications include oral irrigators, hemodialysis machines, medical monitors, sleep-apnea devices and pumps. Electric beds are also listed for this series. DC Output and Load Conditions Nominal output 24 V. Convection rating 5.9 A; catalogue-rated 141.6 W. 10 CFM forced air rating 8.4 A; catalogue-rated 201.6 W. Adjustment range 22.8–25.2 V, using SVR1. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±1.0%; includes setup tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.0%. Efficiency, typical 94%. The higher rating requires 10 CFM forced airflow. The convection rating applies without that forced airflow; do not treat the two ratings as interchangeable. Do not exceed the applicable voltage, current or catalogue-rated power limit. Combine the cooling, input-voltage and ambient-temperature limits. Ripple is measured at 20 MHz with a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Input, Start-Up and Consumption Input range 80–264 VAC or 113–370 VDC; low-input derating applies. Frequency 47–63 Hz. AC input current, typical 2 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 60 A at 230 VAC. No-load consumption Less than 0.5 W. Set-up and rise 700 ms setup and 30 ms rise at both 230 VAC and 115 VAC, full load. Hold-up, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load. Leakage at 264 VAC Earth leakage <180 µA; touch current <40 µA. Touch current is measured from primary input to DC output. Switching-frequency diagram 65 kHz. Power factor Built-in active PFC; PF >0.94 at 230 VAC and >0.98 at 115 VAC, full load. Unless separately stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Protection Short circuit and overload Short-circuit protection is listed. Overload operates at 110–140% of rated output power; hiccup mode recovers automatically after the fault is removed. Overvoltage threshold 26.4–31.2 V. Overvoltage response Output shuts down; re-power on to recover. Overtemperature response Output shuts down. Re-power on to recover. Cooling and Derating Ambient range −30 to +70°C, with derating; horizontal mounting. Convection temperature curve The graph shows 70% load from −30 to 45°C, falling to 40% at 70°C. Use the model-specific convection current and wattage above. Input-voltage curve, 60 Hz 80 VAC: 70%; 115 VAC: 100%, maintained to 264 VAC. The curve is explicitly for 10 CFM operation. 10 CFM temperature curve 100% load from −30 to 50°C, falling to 40% at 70°C. Fan arrangement The mechanical drawing positions an external 10 CFM fan 5 cm from the assembly in the indicated airflow direction; preserve that airflow path. A fan is not claimed as supplied. Use the complete plotted curves for intermediate conditions; the maximum ambient temperature is a derated point. Apply the most restrictive simultaneous limit. Environment Operating humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude 5,000 m. High-altitude derating Above 2,000 m, reduce allowed ambient temperature by 3.5°C per 1,000 m for fanless operation or 5°C per 1,000 m for fan-cooled operation. Dimensions and Installation Dimensions, L × W × H 103.4 × 62 × 40 mm. General drawing tolerance ±1 mm. Mounting geometry Case No. 245A. Side drawing: 2-M3 L=4, spacing 78 mm; bottom: 2-M3 L=2, spacing 55 mm. Side mounting notches are marked 2-R1.75. Follow the complete drawing for positions and permitted engagement. Adjustment Use SVR1 within the stated voltage-adjustment range. Indicator The mechanical drawing identifies an LED power indicator. Follow the manufacturer’s installation manual and the model-specific drawing. No separate mounting-kit ordering code is listed in these assigned pages. Input and Output Connectors AC input CN1 JST B3P-VH or equivalent; pin 1: AC/L, pin 2: No pin, pin 3: AC/N. DC output CN2 JST B6P-VH or equivalent; pins 1, 2, 3 are +V; pins 4, 5, 6 are −V. Input/output mating housing JST VHR or equivalent, exactly the family designation printed in the sheet. Select the matching circuit count; no complete housing suffix is supplied here. Input/output contact JST SVH-21T-P1.1 or equivalent. Connector references identify compatible interfaces, not an included loose cable or accessory kit. Confirm fit and ratings for an equivalent component. Fan Supply and Connector Fan output 12 V at 0.5 A for the cooling fan only. Specified tolerance ±15% at 20% of the main-output rated current under 10 CFM conditions. CN101 JST B2B-PH-K-S or equivalent; pin 1: +12 V, pin 2: DC COM. Mating housing JST PHR-2 or equivalent. Contact JST SPH-002T-P0.5S or equivalent. This output is intended to power the additional external fan for cooling and full-load delivery. Do not use it to drive other devices. Safety and EMC Safety approvals IEC60601-1:2005+A1+A2; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. BS EN/EN60335-1 is a design reference by request, not an unconditional approval. Isolation barriers Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance I/P–O/P, I/P–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions, BS EN/EN55011 (CISPR11) Conducted Class B; radiated Class B with FG in Class I, or Class A without FG in Class II for the PCB type. The enclosed -C type is not suitable for Class II. Harmonics and flicker BS EN/EN61000-3-2 Class A; BS EN/EN61000-3-3 listed. Immunity framework BS EN/EN55035 and BS EN/EN60601-1-2. ESD, IEC/EN61000-4-2 Level 4: 15 kV air and 8 kV contact. RF field, IEC/EN61000-4-3 Level 3: 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT, IEC/EN61000-4-4 Level 3, 2 kV. Surge, IEC/EN61000-4-5 Level 4: 4 kV line–FG; 2 kV line–line. Conducted immunity, IEC/EN61000-4-6 Level 3, 10 V. Magnetic field, IEC/EN61000-4-8 Level 4, 30 A/m. Voltage dips and interruptions, IEC/EN61000-4-11 100% dip for 1 period; 30% dip for 25 periods; 100% interruption for 250 periods. EMC testing uses a 360 × 360 × 1 mm metal plate. This supply is a component for installation in final equipment; the complete equipment must be reconfirmed for EMC and applicable medical-system safety. Weight and Catalogue Reference Single-unit catalogue weight 300 g (0.3 kg), explicitly listed in PACKING; a catalogue reference rather than measured shipment weight. Packing 60 pieces / 19 kg / 1.06 CUFT. Minimum MTBF estimates 2669.7 thousand hours, Telcordia SR-332 (Bellcore); 500.3 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to the applicable manufacturer terms. Catalogue version RPS-200-SPEC 2026-02-28; combined PDF pages 27–32. Lifetime feature The family feature page states lifetime greater than 65,000 hours; it does not state the test conditions there. This is distinct from the MTBF estimates. Family power-density claim The family introduction states up to 21.9 W/in³; this is not an individual configuration measurement. MTBF is a statistical estimate under the listed methods, not a guaranteed service life.

    $125.19

  • RPS-200-15-C

    MEAN WELL RPS-200 series: Enclosed Medical AC/DC Power Supply - RPS-200-15-C

    MEAN WELL RPS-200-15-C is an enclosed medical AC/DC supply with 15 V output. It delivers 141 W by convection and 201 W with 10 CFM forced air. Apply the load, thermal and system-integration conditions below. Product Datasheet Download MEAN WELL RPS-200 Datasheet (PDF) The RPS-200 section is on PDF pages 27, 28, 29, 30, 31, 32. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPS-200-15-C. Series and construction RPS-200 medical AC/DC power supply; enclosed casing, -C option. Voltage code 15 specifies the nominal DC output voltage. System class Use in a Class I system with FG; the -C enclosed type is not suitable for a Class II system without FG. Medical application Primary-to-secondary 2 MOPP. Suitable for BF applications only with appropriate system consideration; final equipment compliance remains an integration requirement. Catalogue applications include oral irrigators, hemodialysis machines, medical monitors, sleep-apnea devices and pumps. Electric beds are also listed for this series. DC Output and Load Conditions Nominal output 15 V. Convection rating 9.4 A; catalogue-rated 141 W. 10 CFM forced air rating 13.4 A; catalogue-rated 201 W. Adjustment range 14.3–15.8 V, using SVR1. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±2.0%; includes setup tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.0%. Efficiency, typical 93.5%. The higher rating requires 10 CFM forced airflow. The convection rating applies without that forced airflow; do not treat the two ratings as interchangeable. Do not exceed the applicable voltage, current or catalogue-rated power limit. Combine the cooling, input-voltage and ambient-temperature limits. Ripple is measured at 20 MHz with a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Input, Start-Up and Consumption Input range 80–264 VAC or 113–370 VDC; low-input derating applies. Frequency 47–63 Hz. AC input current, typical 2 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 60 A at 230 VAC. No-load consumption Less than 0.5 W. Set-up and rise 700 ms setup and 30 ms rise at both 230 VAC and 115 VAC, full load. Hold-up, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load. Leakage at 264 VAC Earth leakage <180 µA; touch current <40 µA. Touch current is measured from primary input to DC output. Switching-frequency diagram 65 kHz. Power factor Built-in active PFC; PF >0.94 at 230 VAC and >0.98 at 115 VAC, full load. Unless separately stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Protection Short circuit and overload Short-circuit protection is listed. Overload operates at 110–140% of rated output power; hiccup mode recovers automatically after the fault is removed. Overvoltage threshold 16.5–19.5 V. Overvoltage response Output shuts down; re-power on to recover. Overtemperature response Output shuts down. Re-power on to recover. Cooling and Derating Ambient range −30 to +70°C, with derating; horizontal mounting. Convection temperature curve The graph shows 70% load from −30 to 45°C, falling to 40% at 70°C. Use the model-specific convection current and wattage above. Input-voltage curve, 60 Hz 80 VAC: 70%; 115 VAC: 100%, maintained to 264 VAC. The curve is explicitly for 10 CFM operation. 10 CFM temperature curve 100% load from −30 to 50°C, falling to 40% at 70°C. Fan arrangement The mechanical drawing positions an external 10 CFM fan 5 cm from the assembly in the indicated airflow direction; preserve that airflow path. A fan is not claimed as supplied. Use the complete plotted curves for intermediate conditions; the maximum ambient temperature is a derated point. Apply the most restrictive simultaneous limit. Environment Operating humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude 5,000 m. High-altitude derating Above 2,000 m, reduce allowed ambient temperature by 3.5°C per 1,000 m for fanless operation or 5°C per 1,000 m for fan-cooled operation. Dimensions and Installation Dimensions, L × W × H 103.4 × 62 × 40 mm. General drawing tolerance ±1 mm. Mounting geometry Case No. 245A. Side drawing: 2-M3 L=4, spacing 78 mm; bottom: 2-M3 L=2, spacing 55 mm. Side mounting notches are marked 2-R1.75. Follow the complete drawing for positions and permitted engagement. Adjustment Use SVR1 within the stated voltage-adjustment range. Indicator The mechanical drawing identifies an LED power indicator. Follow the manufacturer’s installation manual and the model-specific drawing. No separate mounting-kit ordering code is listed in these assigned pages. Input and Output Connectors AC input CN1 JST B3P-VH or equivalent; pin 1: AC/L, pin 2: No pin, pin 3: AC/N. DC output CN2 JST B6P-VH or equivalent; pins 1, 2, 3 are +V; pins 4, 5, 6 are −V. Input/output mating housing JST VHR or equivalent, exactly the family designation printed in the sheet. Select the matching circuit count; no complete housing suffix is supplied here. Input/output contact JST SVH-21T-P1.1 or equivalent. Connector references identify compatible interfaces, not an included loose cable or accessory kit. Confirm fit and ratings for an equivalent component. Fan Supply and Connector Fan output 12 V at 0.5 A for the cooling fan only. Specified tolerance ±15% at 20% of the main-output rated current under 10 CFM conditions. CN101 JST B2B-PH-K-S or equivalent; pin 1: +12 V, pin 2: DC COM. Mating housing JST PHR-2 or equivalent. Contact JST SPH-002T-P0.5S or equivalent. This output is intended to power the additional external fan for cooling and full-load delivery. Do not use it to drive other devices. Safety and EMC Safety approvals IEC60601-1:2005+A1+A2; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. BS EN/EN60335-1 is a design reference by request, not an unconditional approval. Isolation barriers Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance I/P–O/P, I/P–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions, BS EN/EN55011 (CISPR11) Conducted Class B; radiated Class B with FG in Class I, or Class A without FG in Class II for the PCB type. The enclosed -C type is not suitable for Class II. Harmonics and flicker BS EN/EN61000-3-2 Class A; BS EN/EN61000-3-3 listed. Immunity framework BS EN/EN55035 and BS EN/EN60601-1-2. ESD, IEC/EN61000-4-2 Level 4: 15 kV air and 8 kV contact. RF field, IEC/EN61000-4-3 Level 3: 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT, IEC/EN61000-4-4 Level 3, 2 kV. Surge, IEC/EN61000-4-5 Level 4: 4 kV line–FG; 2 kV line–line. Conducted immunity, IEC/EN61000-4-6 Level 3, 10 V. Magnetic field, IEC/EN61000-4-8 Level 4, 30 A/m. Voltage dips and interruptions, IEC/EN61000-4-11 100% dip for 1 period; 30% dip for 25 periods; 100% interruption for 250 periods. EMC testing uses a 360 × 360 × 1 mm metal plate. This supply is a component for installation in final equipment; the complete equipment must be reconfirmed for EMC and applicable medical-system safety. Weight and Catalogue Reference Single-unit catalogue weight 300 g (0.3 kg), explicitly listed in PACKING; a catalogue reference rather than measured shipment weight. Packing 60 pieces / 19 kg / 1.06 CUFT. Minimum MTBF estimates 2669.7 thousand hours, Telcordia SR-332 (Bellcore); 500.3 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to the applicable manufacturer terms. Catalogue version RPS-200-SPEC 2026-02-28; combined PDF pages 27–32. Lifetime feature The family feature page states lifetime greater than 65,000 hours; it does not state the test conditions there. This is distinct from the MTBF estimates. Family power-density claim The family introduction states up to 21.9 W/in³; this is not an individual configuration measurement. MTBF is a statistical estimate under the listed methods, not a guaranteed service life.

    $125.19

  • RPS-200-12-C

    MEAN WELL RPS-200 series: Enclosed Medical AC/DC Power Supply - RPS-200-12-C

    MEAN WELL RPS-200-12-C is an enclosed medical AC/DC supply with 12 V output. It delivers 140.4 W by convection and 200.4 W with 10 CFM forced air. Apply the load, thermal and system-integration conditions below. Product Datasheet Download MEAN WELL RPS-200 Datasheet (PDF) The RPS-200 section is on PDF pages 27, 28, 29, 30, 31, 32. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPS-200-12-C. Series and construction RPS-200 medical AC/DC power supply; enclosed casing, -C option. Voltage code 12 specifies the nominal DC output voltage. System class Use in a Class I system with FG; the -C enclosed type is not suitable for a Class II system without FG. Medical application Primary-to-secondary 2 MOPP. Suitable for BF applications only with appropriate system consideration; final equipment compliance remains an integration requirement. Catalogue applications include oral irrigators, hemodialysis machines, medical monitors, sleep-apnea devices and pumps. Electric beds are also listed for this series. DC Output and Load Conditions Nominal output 12 V. Convection rating 11.7 A; catalogue-rated 140.4 W. 10 CFM forced air rating 16.7 A; catalogue-rated 200.4 W. Adjustment range 11.4–12.6 V, using SVR1. Ripple and noise, maximum 100 mVp-p. Voltage tolerance ±2.0%; includes setup tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.0%. Efficiency, typical 93%. The higher rating requires 10 CFM forced airflow. The convection rating applies without that forced airflow; do not treat the two ratings as interchangeable. Do not exceed the applicable voltage, current or catalogue-rated power limit. Combine the cooling, input-voltage and ambient-temperature limits. Ripple is measured at 20 MHz with a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Input, Start-Up and Consumption Input range 80–264 VAC or 113–370 VDC; low-input derating applies. Frequency 47–63 Hz. AC input current, typical 2 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 60 A at 230 VAC. No-load consumption Less than 0.5 W. Set-up and rise 700 ms setup and 30 ms rise at both 230 VAC and 115 VAC, full load. Hold-up, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load. Leakage at 264 VAC Earth leakage <180 µA; touch current <40 µA. Touch current is measured from primary input to DC output. Switching-frequency diagram 65 kHz. Power factor Built-in active PFC; PF >0.94 at 230 VAC and >0.98 at 115 VAC, full load. Unless separately stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Protection Short circuit and overload Short-circuit protection is listed. Overload operates at 110–140% of rated output power; hiccup mode recovers automatically after the fault is removed. Overvoltage threshold 13.2–15.6 V. Overvoltage response Output shuts down; re-power on to recover. Overtemperature response Output shuts down. Re-power on to recover. Cooling and Derating Ambient range −30 to +70°C, with derating; horizontal mounting. Convection temperature curve The graph shows 70% load from −30 to 45°C, falling to 40% at 70°C. Use the model-specific convection current and wattage above. Input-voltage curve, 60 Hz 80 VAC: 70%; 115 VAC: 100%, maintained to 264 VAC. The curve is explicitly for 10 CFM operation. 10 CFM temperature curve 100% load from −30 to 50°C, falling to 40% at 70°C. Fan arrangement The mechanical drawing positions an external 10 CFM fan 5 cm from the assembly in the indicated airflow direction; preserve that airflow path. A fan is not claimed as supplied. Use the complete plotted curves for intermediate conditions; the maximum ambient temperature is a derated point. Apply the most restrictive simultaneous limit. Environment Operating humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude 5,000 m. High-altitude derating Above 2,000 m, reduce allowed ambient temperature by 3.5°C per 1,000 m for fanless operation or 5°C per 1,000 m for fan-cooled operation. Dimensions and Installation Dimensions, L × W × H 103.4 × 62 × 40 mm. General drawing tolerance ±1 mm. Mounting geometry Case No. 245A. Side drawing: 2-M3 L=4, spacing 78 mm; bottom: 2-M3 L=2, spacing 55 mm. Side mounting notches are marked 2-R1.75. Follow the complete drawing for positions and permitted engagement. Adjustment Use SVR1 within the stated voltage-adjustment range. Indicator The mechanical drawing identifies an LED power indicator. Follow the manufacturer’s installation manual and the model-specific drawing. No separate mounting-kit ordering code is listed in these assigned pages. Input and Output Connectors AC input CN1 JST B3P-VH or equivalent; pin 1: AC/L, pin 2: No pin, pin 3: AC/N. DC output CN2 JST B6P-VH or equivalent; pins 1, 2, 3 are +V; pins 4, 5, 6 are −V. Input/output mating housing JST VHR or equivalent, exactly the family designation printed in the sheet. Select the matching circuit count; no complete housing suffix is supplied here. Input/output contact JST SVH-21T-P1.1 or equivalent. Connector references identify compatible interfaces, not an included loose cable or accessory kit. Confirm fit and ratings for an equivalent component. Fan Supply and Connector Fan output 12 V at 0.5 A for the cooling fan only. Specified tolerance ±15% at 20% of the main-output rated current under 10 CFM conditions. CN101 JST B2B-PH-K-S or equivalent; pin 1: +12 V, pin 2: DC COM. Mating housing JST PHR-2 or equivalent. Contact JST SPH-002T-P0.5S or equivalent. This output is intended to power the additional external fan for cooling and full-load delivery. Do not use it to drive other devices. Safety and EMC Safety approvals IEC60601-1:2005+A1+A2; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. BS EN/EN60335-1 is a design reference by request, not an unconditional approval. Isolation barriers Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance I/P–O/P, I/P–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions, BS EN/EN55011 (CISPR11) Conducted Class B; radiated Class B with FG in Class I, or Class A without FG in Class II for the PCB type. The enclosed -C type is not suitable for Class II. Harmonics and flicker BS EN/EN61000-3-2 Class A; BS EN/EN61000-3-3 listed. Immunity framework BS EN/EN55035 and BS EN/EN60601-1-2. ESD, IEC/EN61000-4-2 Level 4: 15 kV air and 8 kV contact. RF field, IEC/EN61000-4-3 Level 3: 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT, IEC/EN61000-4-4 Level 3, 2 kV. Surge, IEC/EN61000-4-5 Level 4: 4 kV line–FG; 2 kV line–line. Conducted immunity, IEC/EN61000-4-6 Level 3, 10 V. Magnetic field, IEC/EN61000-4-8 Level 4, 30 A/m. Voltage dips and interruptions, IEC/EN61000-4-11 100% dip for 1 period; 30% dip for 25 periods; 100% interruption for 250 periods. EMC testing uses a 360 × 360 × 1 mm metal plate. This supply is a component for installation in final equipment; the complete equipment must be reconfirmed for EMC and applicable medical-system safety. Weight and Catalogue Reference Single-unit catalogue weight 300 g (0.3 kg), explicitly listed in PACKING; a catalogue reference rather than measured shipment weight. Packing 60 pieces / 19 kg / 1.06 CUFT. Minimum MTBF estimates 2669.7 thousand hours, Telcordia SR-332 (Bellcore); 500.3 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to the applicable manufacturer terms. Catalogue version RPS-200-SPEC 2026-02-28; combined PDF pages 27–32. Lifetime feature The family feature page states lifetime greater than 65,000 hours; it does not state the test conditions there. This is distinct from the MTBF estimates. Family power-density claim The family introduction states up to 21.9 W/in³; this is not an individual configuration measurement. MTBF is a statistical estimate under the listed methods, not a guaranteed service life.

    $125.19

  • RPS-200-48

    MEAN WELL RPS-200 series: PCB Medical AC/DC Power Supply - RPS-200-48

    MEAN WELL RPS-200-48 is a PCB open-frame medical AC/DC supply with 48 V output. It delivers 144 W by convection and 201.6 W with 10 CFM forced air. Apply the load, thermal and system-integration conditions below. Product Datasheet Download MEAN WELL RPS-200 Datasheet (PDF) The RPS-200 section is on PDF pages 27, 28, 29, 30, 31, 32. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPS-200-48. Series and construction RPS-200 medical AC/DC power supply; PCB open-frame construction. Voltage code 48 specifies the nominal DC output voltage. System class Suitable for Class I systems with FG or Class II systems without FG, subject to the model-specific EMC conditions below. Medical application Primary-to-secondary 2 MOPP. Suitable for BF applications only with appropriate system consideration; final equipment compliance remains an integration requirement. Catalogue applications include oral irrigators, hemodialysis machines, medical monitors, sleep-apnea devices and pumps. Electric beds are also listed for this series. DC Output and Load Conditions Nominal output 48 V. Convection rating 3 A; catalogue-rated 144 W. 10 CFM forced air rating 4.2 A; catalogue-rated 201.6 W. Adjustment range 45.6–50.4 V, using SVR1. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±1.0%; includes setup tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.0%. Efficiency, typical 95%. The higher rating requires 10 CFM forced airflow. The convection rating applies without that forced airflow; do not treat the two ratings as interchangeable. Do not exceed the applicable voltage, current or catalogue-rated power limit. Combine the cooling, input-voltage and ambient-temperature limits. Ripple is measured at 20 MHz with a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Input, Start-Up and Consumption Input range 80–264 VAC or 113–370 VDC; low-input derating applies. Frequency 47–63 Hz. AC input current, typical 2 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 60 A at 230 VAC. No-load consumption Less than 0.5 W. Set-up and rise 700 ms setup and 30 ms rise at both 230 VAC and 115 VAC, full load. Hold-up, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load. Leakage at 264 VAC Earth leakage <180 µA; touch current <40 µA. Touch current is measured from primary input to DC output. Switching-frequency diagram 65 kHz. Power factor Built-in active PFC; PF >0.94 at 230 VAC and >0.98 at 115 VAC, full load. Unless separately stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Protection Short circuit and overload Short-circuit protection is listed. Overload operates at 110–140% of rated output power; hiccup mode recovers automatically after the fault is removed. Overvoltage threshold 52.8–62.4 V. Overvoltage response Output shuts down; re-power on to recover. Overtemperature response Output shuts down. Re-power on to recover. Cooling and Derating Ambient range −30 to +70°C, with derating; horizontal mounting. Convection temperature curve The graph shows 70% load from −30 to 50°C, falling to 40% at 70°C. Use the model-specific convection current and wattage above. Input-voltage curve, 60 Hz 80 VAC: 70%; 115 VAC: 100%, maintained to 264 VAC. The curve is explicitly for 10 CFM operation. 10 CFM temperature curve 100% load from −30 to 50°C, falling to 40% at 70°C. Fan arrangement The mechanical drawing positions an external 10 CFM fan 5 cm from the assembly in the indicated airflow direction; preserve that airflow path. A fan is not claimed as supplied. Use the complete plotted curves for intermediate conditions; the maximum ambient temperature is a derated point. Apply the most restrictive simultaneous limit. Environment Operating humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude 5,000 m. High-altitude derating Above 2,000 m, reduce allowed ambient temperature by 3.5°C per 1,000 m for fanless operation or 5°C per 1,000 m for fan-cooled operation. Dimensions and Installation Dimensions, L × W × H 101.6 × 50.8 × 29 mm. General drawing tolerance ±1 mm. Mounting geometry Four 3.3 mm mounting holes on a 95.25 × 44.45 mm pattern; 3.175 mm edge offsets; underside projection 3 mm maximum. Follow the complete PCB drawing. Adjustment Use SVR1 within the stated voltage-adjustment range. Indicator The mechanical drawing identifies an LED power indicator. Follow the manufacturer’s installation manual and the model-specific drawing. No separate mounting-kit ordering code is listed in these assigned pages. Input and Output Connectors AC input CN1 JST B3P-VH or equivalent; pin 1: AC/L, pin 2: No pin, pin 3: AC/N. DC output CN2 JST B6P-VH or equivalent; pins 1, 2, 3 are +V; pins 4, 5, 6 are −V. Input/output mating housing JST VHR or equivalent, exactly the family designation printed in the sheet. Select the matching circuit count; no complete housing suffix is supplied here. Input/output contact JST SVH-21T-P1.1 or equivalent. Connector references identify compatible interfaces, not an included loose cable or accessory kit. Confirm fit and ratings for an equivalent component. Fan Supply and Connector Fan output 12 V at 0.5 A for the cooling fan only. Specified tolerance ±15% at 20% of the main-output rated current under 10 CFM conditions. CN101 JST B2B-PH-K-S or equivalent; pin 1: +12 V, pin 2: DC COM. Mating housing JST PHR-2 or equivalent. Contact JST SPH-002T-P0.5S or equivalent. This output is intended to power the additional external fan for cooling and full-load delivery. Do not use it to drive other devices. Safety and EMC Safety approvals IEC60601-1:2005+A1+A2; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. BS EN/EN60335-1 is a design reference by request, not an unconditional approval. Isolation barriers Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance I/P–O/P, I/P–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions, BS EN/EN55011 (CISPR11) Conducted Class B; radiated Class B with FG in Class I, or Class A without FG in Class II for the PCB type. The enclosed -C type is not suitable for Class II. Harmonics and flicker BS EN/EN61000-3-2 Class A; BS EN/EN61000-3-3 listed. Immunity framework BS EN/EN55035 and BS EN/EN60601-1-2. ESD, IEC/EN61000-4-2 Level 4: 15 kV air and 8 kV contact. RF field, IEC/EN61000-4-3 Level 3: 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT, IEC/EN61000-4-4 Level 3, 2 kV. Surge, IEC/EN61000-4-5 Level 4: 4 kV line–FG; 2 kV line–line. Conducted immunity, IEC/EN61000-4-6 Level 3, 10 V. Magnetic field, IEC/EN61000-4-8 Level 4, 30 A/m. Voltage dips and interruptions, IEC/EN61000-4-11 100% dip for 1 period; 30% dip for 25 periods; 100% interruption for 250 periods. EMC testing uses a 360 × 360 × 1 mm metal plate. This supply is a component for installation in final equipment; the complete equipment must be reconfirmed for EMC and applicable medical-system safety. Weight and Catalogue Reference Single-unit catalogue weight 190 g (0.19 kg), explicitly listed in PACKING; a catalogue reference rather than measured shipment weight. Packing 72 pieces / 14.7 kg / 0.84 CUFT. Minimum MTBF estimates 2669.7 thousand hours, Telcordia SR-332 (Bellcore); 500.3 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to the applicable manufacturer terms. Catalogue version RPS-200-SPEC 2026-02-28; combined PDF pages 27–32. Lifetime feature The family feature page states lifetime greater than 65,000 hours; it does not state the test conditions there. This is distinct from the MTBF estimates. Family power-density claim The family introduction states up to 21.9 W/in³; this is not an individual configuration measurement. MTBF is a statistical estimate under the listed methods, not a guaranteed service life.

    $111.88

  • RPS-200-27

    MEAN WELL RPS-200 series: PCB Medical AC/DC Power Supply - RPS-200-27

    MEAN WELL RPS-200-27 is a PCB open-frame medical AC/DC supply with 27 V output. It delivers 143.1 W by convection and 202.5 W with 10 CFM forced air. Apply the load, thermal and system-integration conditions below. Product Datasheet Download MEAN WELL RPS-200 Datasheet (PDF) The RPS-200 section is on PDF pages 27, 28, 29, 30, 31, 32. Refer to the complete mechanical drawings and notes when planning installation. Model and Application Complete model RPS-200-27. Series and construction RPS-200 medical AC/DC power supply; PCB open-frame construction. Voltage code 27 specifies the nominal DC output voltage. System class Suitable for Class I systems with FG or Class II systems without FG, subject to the model-specific EMC conditions below. Medical application Primary-to-secondary 2 MOPP. Suitable for BF applications only with appropriate system consideration; final equipment compliance remains an integration requirement. Catalogue applications include oral irrigators, hemodialysis machines, medical monitors, sleep-apnea devices and pumps. Electric beds are also listed for this series. DC Output and Load Conditions Nominal output 27 V. Convection rating 5.3 A; catalogue-rated 143.1 W. 10 CFM forced air rating 7.5 A; catalogue-rated 202.5 W. Adjustment range 25.6–28.4 V, using SVR1. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±1.0%; includes setup tolerance, line regulation and load regulation. Line regulation ±0.5%. Load regulation ±1.0%. Efficiency, typical 94%. The higher rating requires 10 CFM forced airflow. The convection rating applies without that forced airflow; do not treat the two ratings as interchangeable. Do not exceed the applicable voltage, current or catalogue-rated power limit. Combine the cooling, input-voltage and ambient-temperature limits. Ripple is measured at 20 MHz with a 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Input, Start-Up and Consumption Input range 80–264 VAC or 113–370 VDC; low-input derating applies. Frequency 47–63 Hz. AC input current, typical 2 A at 115 VAC; 1 A at 230 VAC. Cold-start inrush, typical 30 A at 115 VAC; 60 A at 230 VAC. No-load consumption Less than 0.5 W. Set-up and rise 700 ms setup and 30 ms rise at both 230 VAC and 115 VAC, full load. Hold-up, typical 16 ms at 230 VAC; 16 ms at 115 VAC, full load. Leakage at 264 VAC Earth leakage <180 µA; touch current <40 µA. Touch current is measured from primary input to DC output. Switching-frequency diagram 65 kHz. Power factor Built-in active PFC; PF >0.94 at 230 VAC and >0.98 at 115 VAC, full load. Unless separately stated, parameters are measured at 230 VAC, rated load and 25°C ambient. Protection Short circuit and overload Short-circuit protection is listed. Overload operates at 110–140% of rated output power; hiccup mode recovers automatically after the fault is removed. Overvoltage threshold 29.7–35 V. Overvoltage response Output shuts down; re-power on to recover. Overtemperature response Output shuts down. Re-power on to recover. Cooling and Derating Ambient range −30 to +70°C, with derating; horizontal mounting. Convection temperature curve The graph shows 70% load from −30 to 50°C, falling to 40% at 70°C. Use the model-specific convection current and wattage above. Input-voltage curve, 60 Hz 80 VAC: 70%; 115 VAC: 100%, maintained to 264 VAC. The curve is explicitly for 10 CFM operation. 10 CFM temperature curve 100% load from −30 to 50°C, falling to 40% at 70°C. Fan arrangement The mechanical drawing positions an external 10 CFM fan 5 cm from the assembly in the indicated airflow direction; preserve that airflow path. A fan is not claimed as supplied. Use the complete plotted curves for intermediate conditions; the maximum ambient temperature is a derated point. Apply the most restrictive simultaneous limit. Environment Operating humidity 20–90% RH, non-condensing. Storage −40 to +85°C; 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes each along X, Y and Z. Operating altitude 5,000 m. High-altitude derating Above 2,000 m, reduce allowed ambient temperature by 3.5°C per 1,000 m for fanless operation or 5°C per 1,000 m for fan-cooled operation. Dimensions and Installation Dimensions, L × W × H 101.6 × 50.8 × 29 mm. General drawing tolerance ±1 mm. Mounting geometry Four 3.3 mm mounting holes on a 95.25 × 44.45 mm pattern; 3.175 mm edge offsets; underside projection 3 mm maximum. Follow the complete PCB drawing. Adjustment Use SVR1 within the stated voltage-adjustment range. Indicator The mechanical drawing identifies an LED power indicator. Follow the manufacturer’s installation manual and the model-specific drawing. No separate mounting-kit ordering code is listed in these assigned pages. Input and Output Connectors AC input CN1 JST B3P-VH or equivalent; pin 1: AC/L, pin 2: No pin, pin 3: AC/N. DC output CN2 JST B6P-VH or equivalent; pins 1, 2, 3 are +V; pins 4, 5, 6 are −V. Input/output mating housing JST VHR or equivalent, exactly the family designation printed in the sheet. Select the matching circuit count; no complete housing suffix is supplied here. Input/output contact JST SVH-21T-P1.1 or equivalent. Connector references identify compatible interfaces, not an included loose cable or accessory kit. Confirm fit and ratings for an equivalent component. Fan Supply and Connector Fan output 12 V at 0.5 A for the cooling fan only. Specified tolerance ±15% at 20% of the main-output rated current under 10 CFM conditions. CN101 JST B2B-PH-K-S or equivalent; pin 1: +12 V, pin 2: DC COM. Mating housing JST PHR-2 or equivalent. Contact JST SPH-002T-P0.5S or equivalent. This output is intended to power the additional external fan for cooling and full-load delivery. Do not use it to drive other devices. Safety and EMC Safety approvals IEC60601-1:2005+A1+A2; TUV BS EN/EN60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. BS EN/EN60335-1 is a design reference by request, not an unconditional approval. Isolation barriers Primary–secondary: 2 MOPP; primary–earth: 1 MOPP; secondary–earth: 1 MOPP. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance I/P–O/P, I/P–FG: 100 MΩ at 500 VDC, 25°C and 70% RH. Emissions, BS EN/EN55011 (CISPR11) Conducted Class B; radiated Class B with FG in Class I, or Class A without FG in Class II for the PCB type. The enclosed -C type is not suitable for Class II. Harmonics and flicker BS EN/EN61000-3-2 Class A; BS EN/EN61000-3-3 listed. Immunity framework BS EN/EN55035 and BS EN/EN60601-1-2. ESD, IEC/EN61000-4-2 Level 4: 15 kV air and 8 kV contact. RF field, IEC/EN61000-4-3 Level 3: 10 V/m at 80 MHz–2.7 GHz; Table 9 proximity fields 9–28 V/m at 385 MHz–5.78 GHz. EFT, IEC/EN61000-4-4 Level 3, 2 kV. Surge, IEC/EN61000-4-5 Level 4: 4 kV line–FG; 2 kV line–line. Conducted immunity, IEC/EN61000-4-6 Level 3, 10 V. Magnetic field, IEC/EN61000-4-8 Level 4, 30 A/m. Voltage dips and interruptions, IEC/EN61000-4-11 100% dip for 1 period; 30% dip for 25 periods; 100% interruption for 250 periods. EMC testing uses a 360 × 360 × 1 mm metal plate. This supply is a component for installation in final equipment; the complete equipment must be reconfirmed for EMC and applicable medical-system safety. Weight and Catalogue Reference Single-unit catalogue weight 190 g (0.19 kg), explicitly listed in PACKING; a catalogue reference rather than measured shipment weight. Packing 72 pieces / 14.7 kg / 0.84 CUFT. Minimum MTBF estimates 2669.7 thousand hours, Telcordia SR-332 (Bellcore); 500.3 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer warranty 3 years, subject to the applicable manufacturer terms. Catalogue version RPS-200-SPEC 2026-02-28; combined PDF pages 27–32. Lifetime feature The family feature page states lifetime greater than 65,000 hours; it does not state the test conditions there. This is distinct from the MTBF estimates. Family power-density claim The family introduction states up to 21.9 W/in³; this is not an individual configuration measurement. MTBF is a statistical estimate under the listed methods, not a guaranteed service life.

    $111.88


You have seen 24 out of 69 products

Footer image

© 2026 MEAN WELL, ,

  • US (USD $) US (USD $)
  • Ach Direct Debit
  • AliPay
  • Amazon
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • USDC
  • Visa