MPM Series: Green Medical Enclosed Power Supply ,PCB Mount Green Power Module

60 products

MEAN WELL MPM Series Medical Grade Power Modules

Complete Portfolio: 5W to 90W | 2xMOPP Isolation | PCB Mount & Enclosed Types | Ultra-Low Leakage

  • Portfolio Overview
  • Ultra-Compact (5W~20W)
  • High Density (30W~90W)
  • Medical Safety & Protections
  • Form Factors (PCB & ST)

Miniature Green Power for Medical Devices

The MEAN WELL MPM Series represents a state-of-the-art family of high-density, miniature medical power supplies. Offering both PCB-mounted modules for direct board integration and enclosed screw-terminal (-ST) models for chassis wiring, this series is engineered specifically for BF (Body Floating) patient contact medical equipment.

Core Medical Advantages

  • Exceptional Medical Safety: Achieves the highest 2xMOPP (Means of Patient Protection) primary-to-secondary isolation level, ensuring maximum patient safety.
  • Ultra-Low Leakage Current: Designed with an incredibly low touch current (strictly <80μA or <100μA depending on wattage), making it highly suitable for sensitive BF-type medical instruments.
  • "Green" Energy Savings: Features an ultra-low no-load power consumption (as low as <0.075W) to meet the most stringent global energy efficiency regulations.
  • Class II Isolation: Double-insulated design requires no ground wire (No FG), significantly simplifying device design and increasing safety in portable medical equipment.

MPM-05 to MPM-20 Specifications

The lower wattage tier is astonishingly compact. These units act as onboard power "bricks," making them the perfect solution for portable medical devices, handheld testing equipment, and dental clinical tools.

Model Series Max Power DC Voltages Available Efficiency (Max) Leakage Current
MPM-05 5.5W 3.3V, 5V, 12V, 15V, 24V 82% < 80μA
MPM-10 10.2W 3.3V, 5V, 12V, 15V, 24V 84% < 80μA
MPM-15 16.6W 3.3V, 5V, 12V, 15V, 24V 87% < 80μA
MPM-20 23.8W 3.3V, 5V, 12V, 15V, 24V 87% < 80μA
Energy Profile: All models in this tier boast an incredible no-load power consumption of <0.075W and accept a universal AC input of 80 ~ 264VAC.

MPM-30 to MPM-90 Specifications

For more robust medical equipment such as mobile clinical workstations, dialysis machines, and bedside medical monitors, the higher wattage MPM series delivers increased power density in a similarly rugged, fully potted enclosure.

Model Series Max Power DC Voltages Available Efficiency (Max) No-Load Power
MPM-30 31.2W 3.3V, 5V, 12V, 15V, 24V, 48V 91% < 0.075W
MPM-45 50.4W 5V, 12V, 15V, 24V, 48V 92.5% < 0.1W
MPM-65 71.6W 5V, 12V, 15V, 24V, 48V 93% < 0.1W
MPM-90 99W 12V, 15V, 24V, 48V 93% < 0.1W
Leakage Specification: The MPM-30 maintains the strict <80μA leakage, while the larger 45W, 65W, and 90W models operate at an impressive <100μA.

Stringent Protections & EMC Compliance

Global Medical Certifications

  • Standards: Approved to IEC/EN60601-1 and ANSI/AAMI ES60601-1 medical safety standards (3rd Edition).
  • EMC Integrity: Meets EMI Class B (EN55011) standards directly without requiring any additional external noise-filtering components. This protects nearby sensitive diagnostic equipment from electromagnetic interference.

Hardware Defenses & Durability

  • Fully Encapsulated: The modules are entirely potted with medical-grade silicone. This ensures superior heat dissipation, resistance to harsh vibration (up to 5G), and protects internal components from clinical dust and moisture.
  • Protections: Built-in, automatic-recovery safeguards against Short Circuit, Overload, Over Voltage, and Over Temperature.
  • Extreme Environments: Boasts an incredibly wide operating temperature range from -40°C to +85°C (derating applies at highest temperatures).

Two Versatile Installation Formats

The MPM series is uniquely designed to offer engineers maximum flexibility depending on the mechanical layout of their medical device.

1. PCB Mount Type (Standard)

Designed with standard soldering pins on the bottom, intended for direct through-hole mounting onto printed circuit boards.

  • MPM-05 & MPM-10: 45.7 * 25.4 * 21.5 mm
  • MPM-15 & MPM-20: 52.4 * 27.2 * 24 mm
  • MPM-30: 69.5 * 39 * 24 mm
  • MPM-45 & MPM-65 & MPM-90: 87 * 52 * 29.5 mm

2. Screw Terminal Type (Suffix "-ST")

By adding "-ST" to the model number (available for MPM-30 through MPM-90), the unit comes pre-installed in a slightly larger plastic housing equipped with screw terminals. This is ideal for panel mounting, wire harnesses, and enclosed chassis applications.

  • MPM-30-ST: 91 * 39.5 * 28.5 mm
  • MPM-45-ST & MPM-65-ST & MPM-90-ST: 109 * 52 * 33.5 mm
  • MPM-90-48ST

    MEAN WELL MPM-90 series: screw-terminal medical AC/DC power module - MPM-90-48ST

    MEAN WELL MPM-90-48ST is a screw-terminal medical AC/DC power module delivering 48 V DC at 1.88 A (90.2 W) by convection, with a conditional 2.07 A / 99.2 W peak rating for up to 10 seconds. It accepts 80–264 V AC or 113–370 V DC and provides Class II insulation with 2 × MOPP; BF application suitability depends on the completed system. Product Datasheet Download MEAN WELL MPM-90 Datasheet (PDF) The MPM-90 section is on PDF pages 29, 30, 31, 32. Refer to the complete mechanical drawings and notes when planning installation. Model and mounting Complete model MPM-90-48ST Product type Isolated AC/DC medical power module, single 48 V DC output Mounting configuration ST suffix: screw-terminal mounting version. Model code MPM identifies the series; 90 identifies the family; 48 identifies nominal output voltage. Use the actual continuous and peak ratings below. Output and peak load Nominal DC output 48 V Continuous convection rating 1.88 A; 90.2 W Peak rating 2.07 A; 99.2 W, for up to 10 seconds under the duty and average-power limits. Ripple and noise, maximum 240 mV peak-to-peak Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±0.5% Minimum load No minimum load required. Peak operation is limited to a maximum 33% duty cycle within every 30-second interval, and average output power must not exceed the continuous rated power. The peak duration, duty cycle, average power and thermal/input derating conditions all apply together. Ripple and noise are measured with a 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Unless separately stated, catalogue parameters use 230 V AC input, rated load and 25°C ambient. Input, efficiency and timing Input range 80–264 V AC or 113–370 V DC; output derating applies at low input. AC frequency 47–63 Hz Typical efficiency 93% at the catalogue reference conditions. Typical AC current 1.9 A at 115 V AC; 1.1 A at 230 V AC. Typical cold-start inrush 30 A at 115 V AC; 65 A at 230 V AC. Set-up / rise time 1000 ms / 30 ms at 230 V AC or 115 V AC, full load. Typical hold-up time 30 ms at 230 V AC; 10 ms at 115 V AC, full load. No-load input power Less than 0.1 W. The 60 Hz input-voltage curve on PDF page 31 permits 80% load at 80 V AC, rising to 100% at 100 V AC and remaining at 100% through 264 V AC. Apply this together with the ambient-temperature curve. The block diagram identifies a 70 kHz switching frequency. Protection Short circuit / overload Overload threshold: 115–160% of rated output power. Hiccup protection recovers automatically after the fault is removed. Overvoltage 50.4–64.8 V; output shuts down. Re-power the unit to recover. Overtemperature Output shuts down; re-power the unit to recover. Temperature, cooling and altitude Working ambient range -30 to +80°C, subject to the applicable load derating curve. Storage temperature -40 to +85°C. Working humidity 20–90% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Maximum operating altitude / overvoltage category 4000 m / OVC II. The horizontal-mounting curve allows 100% load from -30°C to 50°C at 100 V AC, or to 55°C at 230 V AC. Follow the respective sloping curve above those temperatures; both show 50% load at 70°C and 25% at 80°C. Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this convection-cooled module. A generic 5°C/1000 m note for fan-equipped models does not identify a fan in this version. The upper ambient limit is not a full-load rating. Medical isolation and integration Insulation class Class II, double insulation; no functional-ground terminal. Primary-to-secondary protection 2 × MOPP (means of patient protection). Input-to-output withstand voltage 4 kV AC. Input-to-output insulation resistance 100 MΩ at 500 V DC, 25°C and 70% RH. Maximum touch current Less than 100 µA at 264 V AC, measured from primary input to DC output. Suitable for BF (body-floating, patient-contact) applications only with appropriate system consideration. The module is a component, so the completed medical equipment and its applied-part isolation must be assessed as a system. The specification lists IEC 60601-1:2005+A1; TUV BS EN/EN 60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; and EAC TP TC 004 approvals. Design reference to BS EN/EN 60335-1 is by request and is not a blanket approval for every delivered unit. Catalogue application examples include portable medical devices, mobile clinical workstations, medical computer monitors and medical examination instruments. EMC Conducted and radiated emissions BS EN/EN 55011 (CISPR 11), Class B; the family feature states Class B without additional components. Harmonic current BS EN/EN 61000-3-2, Class A. Voltage flicker BS EN/EN 61000-3-3 is listed; no separate class or level is stated. Immunity standards BS EN/EN 55035 and BS EN/EN 60601-1-2. Immunity test entries: BS EN/EN 61000-4-2, ESD Level 4, 15 kV air and 8 kV contact; 61000-4-3, RF Level 3, 10 V/m from 80 MHz to 2.7 GHz, plus Table 9 fields of 9–28 V/m from 385 MHz to 5.78 GHz; 61000-4-4, EFT Level 3, 2 kV; 61000-4-5, surge Level 3, 1 kV line-to-line; 61000-4-6, conducted Level 3, 10 V; and 61000-4-8, magnetic field Level 4, 30 A/m. The BS EN/EN 61000-4-11 entries are greater than 95% dip for 0.5 periods, 30% dip for 25 periods, and greater than 95% interruption for 250 periods. These component test entries do not replace final-equipment EMC verification. Dimensions, terminals and installation Overall dimensions, L × W × H 109 × 52 × 33.5 mm Catalogue case / general tolerance IRM60 / ±1 mm unless otherwise marked. Connection method Screw terminals marked AC/N, AC/L, −Vo and +Vo. Vibration 10–500 Hz, 5 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. The top-view drawing on PDF page 32 labels the input terminals AC/N then AC/L from left to right. The output bank is −Vo, −Vo, +Vo, +Vo from left to right. Input terminal pitch is 7.5 mm and output pitch is 5 mm. Four 3.5 mm diameter mounting holes form the dimensioned 33 × 98 mm pattern. Overall height is 33.5 mm; the separate 6.7 mm side-view dimension is a drawing reference, not an additional overall height. Use the model-specific installation drawing and the manufacturer installation instructions referenced in the PDF. The catalogue does not specify a separate mating-connector, bracket or wiring-kit order code for this version; it also does not give terminal torque or wire-gauge values. Select installation hardware for the actual mounting and electrical conditions. Reference mass and reliability Catalogue packing reference per unit 219 g, from the explicit unit value in the PACKING entry on PDF page 30. This is not a measured net weight or shipping-package weight. MTBF, catalogue minimum estimates 4548.9 thousand hours, Telcordia SR-332 (Bellcore); 570.5 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer datasheet warranty 3 years.

  • MPM-90-24ST

    MEAN WELL MPM-90 series: screw-terminal medical AC/DC power module - MPM-90-24ST

    MEAN WELL MPM-90-24ST is a screw-terminal medical AC/DC power module delivering 24 V DC at 3.75 A (90 W) by convection, with a conditional 4.13 A / 99 W peak rating for up to 10 seconds. It accepts 80–264 V AC or 113–370 V DC and provides Class II insulation with 2 × MOPP; BF application suitability depends on the completed system. Product Datasheet Download MEAN WELL MPM-90 Datasheet (PDF) The MPM-90 section is on PDF pages 29, 30, 31, 32. Refer to the complete mechanical drawings and notes when planning installation. Model and mounting Complete model MPM-90-24ST Product type Isolated AC/DC medical power module, single 24 V DC output Mounting configuration ST suffix: screw-terminal mounting version. Model code MPM identifies the series; 90 identifies the family; 24 identifies nominal output voltage. Use the actual continuous and peak ratings below. Output and peak load Nominal DC output 24 V Continuous convection rating 3.75 A; 90 W Peak rating 4.13 A; 99 W, for up to 10 seconds under the duty and average-power limits. Ripple and noise, maximum 200 mV peak-to-peak Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±0.5% Minimum load No minimum load required. Peak operation is limited to a maximum 33% duty cycle within every 30-second interval, and average output power must not exceed the continuous rated power. The peak duration, duty cycle, average power and thermal/input derating conditions all apply together. Ripple and noise are measured with a 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Unless separately stated, catalogue parameters use 230 V AC input, rated load and 25°C ambient. Input, efficiency and timing Input range 80–264 V AC or 113–370 V DC; output derating applies at low input. AC frequency 47–63 Hz Typical efficiency 93% at the catalogue reference conditions. Typical AC current 1.9 A at 115 V AC; 1.1 A at 230 V AC. Typical cold-start inrush 30 A at 115 V AC; 65 A at 230 V AC. Set-up / rise time 1000 ms / 30 ms at 230 V AC or 115 V AC, full load. Typical hold-up time 30 ms at 230 V AC; 10 ms at 115 V AC, full load. No-load input power Less than 0.1 W. The 60 Hz input-voltage curve on PDF page 31 permits 80% load at 80 V AC, rising to 100% at 100 V AC and remaining at 100% through 264 V AC. Apply this together with the ambient-temperature curve. The block diagram identifies a 70 kHz switching frequency. Protection Short circuit / overload Overload threshold: 115–160% of rated output power. Hiccup protection recovers automatically after the fault is removed. Overvoltage 25.2–32.4 V; output shuts down. Re-power the unit to recover. Overtemperature Output shuts down; re-power the unit to recover. Temperature, cooling and altitude Working ambient range -30 to +80°C, subject to the applicable load derating curve. Storage temperature -40 to +85°C. Working humidity 20–90% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Maximum operating altitude / overvoltage category 4000 m / OVC II. The horizontal-mounting curve allows 100% load from -30°C to 50°C at 100 V AC, or to 55°C at 230 V AC. Follow the respective sloping curve above those temperatures; both show 50% load at 70°C and 25% at 80°C. Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this convection-cooled module. A generic 5°C/1000 m note for fan-equipped models does not identify a fan in this version. The upper ambient limit is not a full-load rating. Medical isolation and integration Insulation class Class II, double insulation; no functional-ground terminal. Primary-to-secondary protection 2 × MOPP (means of patient protection). Input-to-output withstand voltage 4 kV AC. Input-to-output insulation resistance 100 MΩ at 500 V DC, 25°C and 70% RH. Maximum touch current Less than 100 µA at 264 V AC, measured from primary input to DC output. Suitable for BF (body-floating, patient-contact) applications only with appropriate system consideration. The module is a component, so the completed medical equipment and its applied-part isolation must be assessed as a system. The specification lists IEC 60601-1:2005+A1; TUV BS EN/EN 60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; and EAC TP TC 004 approvals. Design reference to BS EN/EN 60335-1 is by request and is not a blanket approval for every delivered unit. Catalogue application examples include portable medical devices, mobile clinical workstations, medical computer monitors and medical examination instruments. EMC Conducted and radiated emissions BS EN/EN 55011 (CISPR 11), Class B; the family feature states Class B without additional components. Harmonic current BS EN/EN 61000-3-2, Class A. Voltage flicker BS EN/EN 61000-3-3 is listed; no separate class or level is stated. Immunity standards BS EN/EN 55035 and BS EN/EN 60601-1-2. Immunity test entries: BS EN/EN 61000-4-2, ESD Level 4, 15 kV air and 8 kV contact; 61000-4-3, RF Level 3, 10 V/m from 80 MHz to 2.7 GHz, plus Table 9 fields of 9–28 V/m from 385 MHz to 5.78 GHz; 61000-4-4, EFT Level 3, 2 kV; 61000-4-5, surge Level 3, 1 kV line-to-line; 61000-4-6, conducted Level 3, 10 V; and 61000-4-8, magnetic field Level 4, 30 A/m. The BS EN/EN 61000-4-11 entries are greater than 95% dip for 0.5 periods, 30% dip for 25 periods, and greater than 95% interruption for 250 periods. These component test entries do not replace final-equipment EMC verification. Dimensions, terminals and installation Overall dimensions, L × W × H 109 × 52 × 33.5 mm Catalogue case / general tolerance IRM60 / ±1 mm unless otherwise marked. Connection method Screw terminals marked AC/N, AC/L, −Vo and +Vo. Vibration 10–500 Hz, 5 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. The top-view drawing on PDF page 32 labels the input terminals AC/N then AC/L from left to right. The output bank is −Vo, −Vo, +Vo, +Vo from left to right. Input terminal pitch is 7.5 mm and output pitch is 5 mm. Four 3.5 mm diameter mounting holes form the dimensioned 33 × 98 mm pattern. Overall height is 33.5 mm; the separate 6.7 mm side-view dimension is a drawing reference, not an additional overall height. Use the model-specific installation drawing and the manufacturer installation instructions referenced in the PDF. The catalogue does not specify a separate mating-connector, bracket or wiring-kit order code for this version; it also does not give terminal torque or wire-gauge values. Select installation hardware for the actual mounting and electrical conditions. Reference mass and reliability Catalogue packing reference per unit 219 g, from the explicit unit value in the PACKING entry on PDF page 30. This is not a measured net weight or shipping-package weight. MTBF, catalogue minimum estimates 4548.9 thousand hours, Telcordia SR-332 (Bellcore); 570.5 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer datasheet warranty 3 years.

  • MPM-90-15ST

    MEAN WELL MPM-90 series: screw-terminal medical AC/DC power module - MPM-90-15ST

    MEAN WELL MPM-90-15ST is a screw-terminal medical AC/DC power module delivering 15 V DC at 5.67 A (85.05 W) by convection, with a conditional 6.23 A / 93.5 W peak rating for up to 10 seconds. It accepts 80–264 V AC or 113–370 V DC and provides Class II insulation with 2 × MOPP; BF application suitability depends on the completed system. Product Datasheet Download MEAN WELL MPM-90 Datasheet (PDF) The MPM-90 section is on PDF pages 29, 30, 31, 32. Refer to the complete mechanical drawings and notes when planning installation. Model and mounting Complete model MPM-90-15ST Product type Isolated AC/DC medical power module, single 15 V DC output Mounting configuration ST suffix: screw-terminal mounting version. Model code MPM identifies the series; 90 identifies the family; 15 identifies nominal output voltage. Use the actual continuous and peak ratings below. Output and peak load Nominal DC output 15 V Continuous convection rating 5.67 A; 85.05 W Peak rating 6.23 A; 93.5 W, for up to 10 seconds under the duty and average-power limits. Ripple and noise, maximum 150 mV peak-to-peak Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±0.5% Minimum load No minimum load required. Peak operation is limited to a maximum 33% duty cycle within every 30-second interval, and average output power must not exceed the continuous rated power. The peak duration, duty cycle, average power and thermal/input derating conditions all apply together. Ripple and noise are measured with a 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Unless separately stated, catalogue parameters use 230 V AC input, rated load and 25°C ambient. Input, efficiency and timing Input range 80–264 V AC or 113–370 V DC; output derating applies at low input. AC frequency 47–63 Hz Typical efficiency 92.5% at the catalogue reference conditions. Typical AC current 1.9 A at 115 V AC; 1.1 A at 230 V AC. Typical cold-start inrush 30 A at 115 V AC; 65 A at 230 V AC. Set-up / rise time 1000 ms / 30 ms at 230 V AC or 115 V AC, full load. Typical hold-up time 30 ms at 230 V AC; 10 ms at 115 V AC, full load. No-load input power Less than 0.1 W. The 60 Hz input-voltage curve on PDF page 31 permits 80% load at 80 V AC, rising to 100% at 100 V AC and remaining at 100% through 264 V AC. Apply this together with the ambient-temperature curve. The block diagram identifies a 70 kHz switching frequency. Protection Short circuit / overload Overload threshold: 115–160% of rated output power. Hiccup protection recovers automatically after the fault is removed. Overvoltage 15.8–20.3 V; output shuts down. Re-power the unit to recover. Overtemperature Output shuts down; re-power the unit to recover. Temperature, cooling and altitude Working ambient range -30 to +80°C, subject to the applicable load derating curve. Storage temperature -40 to +85°C. Working humidity 20–90% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Maximum operating altitude / overvoltage category 4000 m / OVC II. The horizontal-mounting curve allows 100% load from -30°C to 50°C at 100 V AC, or to 55°C at 230 V AC. Follow the respective sloping curve above those temperatures; both show 50% load at 70°C and 25% at 80°C. Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this convection-cooled module. A generic 5°C/1000 m note for fan-equipped models does not identify a fan in this version. The upper ambient limit is not a full-load rating. Medical isolation and integration Insulation class Class II, double insulation; no functional-ground terminal. Primary-to-secondary protection 2 × MOPP (means of patient protection). Input-to-output withstand voltage 4 kV AC. Input-to-output insulation resistance 100 MΩ at 500 V DC, 25°C and 70% RH. Maximum touch current Less than 100 µA at 264 V AC, measured from primary input to DC output. Suitable for BF (body-floating, patient-contact) applications only with appropriate system consideration. The module is a component, so the completed medical equipment and its applied-part isolation must be assessed as a system. The specification lists IEC 60601-1:2005+A1; TUV BS EN/EN 60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; and EAC TP TC 004 approvals. Design reference to BS EN/EN 60335-1 is by request and is not a blanket approval for every delivered unit. Catalogue application examples include portable medical devices, mobile clinical workstations, medical computer monitors and medical examination instruments. EMC Conducted and radiated emissions BS EN/EN 55011 (CISPR 11), Class B; the family feature states Class B without additional components. Harmonic current BS EN/EN 61000-3-2, Class A. Voltage flicker BS EN/EN 61000-3-3 is listed; no separate class or level is stated. Immunity standards BS EN/EN 55035 and BS EN/EN 60601-1-2. Immunity test entries: BS EN/EN 61000-4-2, ESD Level 4, 15 kV air and 8 kV contact; 61000-4-3, RF Level 3, 10 V/m from 80 MHz to 2.7 GHz, plus Table 9 fields of 9–28 V/m from 385 MHz to 5.78 GHz; 61000-4-4, EFT Level 3, 2 kV; 61000-4-5, surge Level 3, 1 kV line-to-line; 61000-4-6, conducted Level 3, 10 V; and 61000-4-8, magnetic field Level 4, 30 A/m. The BS EN/EN 61000-4-11 entries are greater than 95% dip for 0.5 periods, 30% dip for 25 periods, and greater than 95% interruption for 250 periods. These component test entries do not replace final-equipment EMC verification. Dimensions, terminals and installation Overall dimensions, L × W × H 109 × 52 × 33.5 mm Catalogue case / general tolerance IRM60 / ±1 mm unless otherwise marked. Connection method Screw terminals marked AC/N, AC/L, −Vo and +Vo. Vibration 10–500 Hz, 5 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. The top-view drawing on PDF page 32 labels the input terminals AC/N then AC/L from left to right. The output bank is −Vo, −Vo, +Vo, +Vo from left to right. Input terminal pitch is 7.5 mm and output pitch is 5 mm. Four 3.5 mm diameter mounting holes form the dimensioned 33 × 98 mm pattern. Overall height is 33.5 mm; the separate 6.7 mm side-view dimension is a drawing reference, not an additional overall height. Use the model-specific installation drawing and the manufacturer installation instructions referenced in the PDF. The catalogue does not specify a separate mating-connector, bracket or wiring-kit order code for this version; it also does not give terminal torque or wire-gauge values. Select installation hardware for the actual mounting and electrical conditions. Reference mass and reliability Catalogue packing reference per unit 219 g, from the explicit unit value in the PACKING entry on PDF page 30. This is not a measured net weight or shipping-package weight. MTBF, catalogue minimum estimates 4548.9 thousand hours, Telcordia SR-332 (Bellcore); 570.5 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer datasheet warranty 3 years.

  • MPM-90-12ST

    MEAN WELL MPM-90 series: screw-terminal medical AC/DC power module - MPM-90-12ST

    MEAN WELL MPM-90-12ST is a screw-terminal medical AC/DC power module delivering 12 V DC at 6.7 A (80.4 W) by convection, with a conditional 7.37 A / 88.4 W peak rating for up to 10 seconds. It accepts 80–264 V AC or 113–370 V DC and provides Class II insulation with 2 × MOPP; BF application suitability depends on the completed system. Product Datasheet Download MEAN WELL MPM-90 Datasheet (PDF) The MPM-90 section is on PDF pages 29, 30, 31, 32. Refer to the complete mechanical drawings and notes when planning installation. Model and mounting Complete model MPM-90-12ST Product type Isolated AC/DC medical power module, single 12 V DC output Mounting configuration ST suffix: screw-terminal mounting version. Model code MPM identifies the series; 90 identifies the family; 12 identifies nominal output voltage. Use the actual continuous and peak ratings below. Output and peak load Nominal DC output 12 V Continuous convection rating 6.7 A; 80.4 W Peak rating 7.37 A; 88.4 W, for up to 10 seconds under the duty and average-power limits. Ripple and noise, maximum 120 mV peak-to-peak Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±1.0% Minimum load No minimum load required. Peak operation is limited to a maximum 33% duty cycle within every 30-second interval, and average output power must not exceed the continuous rated power. The peak duration, duty cycle, average power and thermal/input derating conditions all apply together. Ripple and noise are measured with a 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Unless separately stated, catalogue parameters use 230 V AC input, rated load and 25°C ambient. Input, efficiency and timing Input range 80–264 V AC or 113–370 V DC; output derating applies at low input. AC frequency 47–63 Hz Typical efficiency 92% at the catalogue reference conditions. Typical AC current 1.9 A at 115 V AC; 1.1 A at 230 V AC. Typical cold-start inrush 30 A at 115 V AC; 65 A at 230 V AC. Set-up / rise time 1000 ms / 30 ms at 230 V AC or 115 V AC, full load. Typical hold-up time 30 ms at 230 V AC; 10 ms at 115 V AC, full load. No-load input power Less than 0.1 W. The 60 Hz input-voltage curve on PDF page 31 permits 80% load at 80 V AC, rising to 100% at 100 V AC and remaining at 100% through 264 V AC. Apply this together with the ambient-temperature curve. The block diagram identifies a 70 kHz switching frequency. Protection Short circuit / overload Overload threshold: 115–160% of rated output power. Hiccup protection recovers automatically after the fault is removed. Overvoltage 12.6–16.2 V; output shuts down. Re-power the unit to recover. Overtemperature Output shuts down; re-power the unit to recover. Temperature, cooling and altitude Working ambient range -30 to +80°C, subject to the applicable load derating curve. Storage temperature -40 to +85°C. Working humidity 20–90% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Maximum operating altitude / overvoltage category 4000 m / OVC II. The horizontal-mounting curve allows 100% load from -30°C to 50°C at 100 V AC, or to 55°C at 230 V AC. Follow the respective sloping curve above those temperatures; both show 50% load at 70°C and 25% at 80°C. Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this convection-cooled module. A generic 5°C/1000 m note for fan-equipped models does not identify a fan in this version. The upper ambient limit is not a full-load rating. Medical isolation and integration Insulation class Class II, double insulation; no functional-ground terminal. Primary-to-secondary protection 2 × MOPP (means of patient protection). Input-to-output withstand voltage 4 kV AC. Input-to-output insulation resistance 100 MΩ at 500 V DC, 25°C and 70% RH. Maximum touch current Less than 100 µA at 264 V AC, measured from primary input to DC output. Suitable for BF (body-floating, patient-contact) applications only with appropriate system consideration. The module is a component, so the completed medical equipment and its applied-part isolation must be assessed as a system. The specification lists IEC 60601-1:2005+A1; TUV BS EN/EN 60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; and EAC TP TC 004 approvals. Design reference to BS EN/EN 60335-1 is by request and is not a blanket approval for every delivered unit. Catalogue application examples include portable medical devices, mobile clinical workstations, medical computer monitors and medical examination instruments. EMC Conducted and radiated emissions BS EN/EN 55011 (CISPR 11), Class B; the family feature states Class B without additional components. Harmonic current BS EN/EN 61000-3-2, Class A. Voltage flicker BS EN/EN 61000-3-3 is listed; no separate class or level is stated. Immunity standards BS EN/EN 55035 and BS EN/EN 60601-1-2. Immunity test entries: BS EN/EN 61000-4-2, ESD Level 4, 15 kV air and 8 kV contact; 61000-4-3, RF Level 3, 10 V/m from 80 MHz to 2.7 GHz, plus Table 9 fields of 9–28 V/m from 385 MHz to 5.78 GHz; 61000-4-4, EFT Level 3, 2 kV; 61000-4-5, surge Level 3, 1 kV line-to-line; 61000-4-6, conducted Level 3, 10 V; and 61000-4-8, magnetic field Level 4, 30 A/m. The BS EN/EN 61000-4-11 entries are greater than 95% dip for 0.5 periods, 30% dip for 25 periods, and greater than 95% interruption for 250 periods. These component test entries do not replace final-equipment EMC verification. Dimensions, terminals and installation Overall dimensions, L × W × H 109 × 52 × 33.5 mm Catalogue case / general tolerance IRM60 / ±1 mm unless otherwise marked. Connection method Screw terminals marked AC/N, AC/L, −Vo and +Vo. Vibration 10–500 Hz, 5 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. The top-view drawing on PDF page 32 labels the input terminals AC/N then AC/L from left to right. The output bank is −Vo, −Vo, +Vo, +Vo from left to right. Input terminal pitch is 7.5 mm and output pitch is 5 mm. Four 3.5 mm diameter mounting holes form the dimensioned 33 × 98 mm pattern. Overall height is 33.5 mm; the separate 6.7 mm side-view dimension is a drawing reference, not an additional overall height. Use the model-specific installation drawing and the manufacturer installation instructions referenced in the PDF. The catalogue does not specify a separate mating-connector, bracket or wiring-kit order code for this version; it also does not give terminal torque or wire-gauge values. Select installation hardware for the actual mounting and electrical conditions. Reference mass and reliability Catalogue packing reference per unit 219 g, from the explicit unit value in the PACKING entry on PDF page 30. This is not a measured net weight or shipping-package weight. MTBF, catalogue minimum estimates 4548.9 thousand hours, Telcordia SR-332 (Bellcore); 570.5 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer datasheet warranty 3 years.

  • MPM-90-48

    MEAN WELL MPM-90 series: PCB-mount medical AC/DC power module - MPM-90-48

    MEAN WELL MPM-90-48 is a PCB-mount medical AC/DC power module delivering 48 V DC at 1.88 A (90.2 W) by convection, with a conditional 2.07 A / 99.2 W peak rating for up to 10 seconds. It accepts 80–264 V AC or 113–370 V DC and provides Class II insulation with 2 × MOPP; BF application suitability depends on the completed system. Product Datasheet Download MEAN WELL MPM-90 Datasheet (PDF) The MPM-90 section is on PDF pages 29, 30, 31, 32. Refer to the complete mechanical drawings and notes when planning installation. Model and mounting Complete model MPM-90-48 Product type Isolated AC/DC medical power module, single 48 V DC output Mounting configuration No suffix: PCB mounting version. Model code MPM identifies the series; 90 identifies the family; 48 identifies nominal output voltage. Use the actual continuous and peak ratings below. Output and peak load Nominal DC output 48 V Continuous convection rating 1.88 A; 90.2 W Peak rating 2.07 A; 99.2 W, for up to 10 seconds under the duty and average-power limits. Ripple and noise, maximum 240 mV peak-to-peak Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±0.5% Minimum load No minimum load required. Peak operation is limited to a maximum 33% duty cycle within every 30-second interval, and average output power must not exceed the continuous rated power. The peak duration, duty cycle, average power and thermal/input derating conditions all apply together. Ripple and noise are measured with a 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Unless separately stated, catalogue parameters use 230 V AC input, rated load and 25°C ambient. Input, efficiency and timing Input range 80–264 V AC or 113–370 V DC; output derating applies at low input. AC frequency 47–63 Hz Typical efficiency 93% at the catalogue reference conditions. Typical AC current 1.9 A at 115 V AC; 1.1 A at 230 V AC. Typical cold-start inrush 30 A at 115 V AC; 65 A at 230 V AC. Set-up / rise time 1000 ms / 30 ms at 230 V AC or 115 V AC, full load. Typical hold-up time 30 ms at 230 V AC; 10 ms at 115 V AC, full load. No-load input power Less than 0.1 W. The 60 Hz input-voltage curve on PDF page 31 permits 80% load at 80 V AC, rising to 100% at 100 V AC and remaining at 100% through 264 V AC. Apply this together with the ambient-temperature curve. The block diagram identifies a 70 kHz switching frequency. Protection Short circuit / overload Overload threshold: 115–160% of rated output power. Hiccup protection recovers automatically after the fault is removed. Overvoltage 50.4–64.8 V; output shuts down. Re-power the unit to recover. Overtemperature Output shuts down; re-power the unit to recover. Temperature, cooling and altitude Working ambient range -30 to +80°C, subject to the applicable load derating curve. Storage temperature -40 to +85°C. Working humidity 20–90% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Maximum operating altitude / overvoltage category 4000 m / OVC II. The horizontal-mounting curve allows 100% load from -30°C to 50°C at 100 V AC, or to 55°C at 230 V AC. Follow the respective sloping curve above those temperatures; both show 50% load at 70°C and 25% at 80°C. Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this convection-cooled module. A generic 5°C/1000 m note for fan-equipped models does not identify a fan in this version. The upper ambient limit is not a full-load rating. Medical isolation and integration Insulation class Class II, double insulation; no functional-ground terminal. Primary-to-secondary protection 2 × MOPP (means of patient protection). Input-to-output withstand voltage 4 kV AC. Input-to-output insulation resistance 100 MΩ at 500 V DC, 25°C and 70% RH. Maximum touch current Less than 100 µA at 264 V AC, measured from primary input to DC output. Suitable for BF (body-floating, patient-contact) applications only with appropriate system consideration. The module is a component, so the completed medical equipment and its applied-part isolation must be assessed as a system. The specification lists IEC 60601-1:2005+A1; TUV BS EN/EN 60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; and EAC TP TC 004 approvals. Design reference to BS EN/EN 60335-1 is by request and is not a blanket approval for every delivered unit. Catalogue application examples include portable medical devices, mobile clinical workstations, medical computer monitors and medical examination instruments. EMC Conducted and radiated emissions BS EN/EN 55011 (CISPR 11), Class B; the family feature states Class B without additional components. Harmonic current BS EN/EN 61000-3-2, Class A. Voltage flicker BS EN/EN 61000-3-3 is listed; no separate class or level is stated. Immunity standards BS EN/EN 55035 and BS EN/EN 60601-1-2. Immunity test entries: BS EN/EN 61000-4-2, ESD Level 4, 15 kV air and 8 kV contact; 61000-4-3, RF Level 3, 10 V/m from 80 MHz to 2.7 GHz, plus Table 9 fields of 9–28 V/m from 385 MHz to 5.78 GHz; 61000-4-4, EFT Level 3, 2 kV; 61000-4-5, surge Level 3, 1 kV line-to-line; 61000-4-6, conducted Level 3, 10 V; and 61000-4-8, magnetic field Level 4, 30 A/m. The BS EN/EN 61000-4-11 entries are greater than 95% dip for 0.5 periods, 30% dip for 25 periods, and greater than 95% interruption for 250 periods. These component test entries do not replace final-equipment EMC verification. Dimensions, terminals and installation Overall dimensions, L × W × H 87 × 52 × 29.5 mm Catalogue case / general tolerance IRM60 / ±1 mm unless otherwise marked. Connection method PCB pins marked AC/N, AC/L, −Vo and +Vo; bottom-view footprint. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Use the bottom-view PCB footprint on PDF page 32: AC/N and AC/L are the two input pins on the right of that drawing; −Vo and +Vo are the two output pins on the left. AC pins are 1 mm diameter and DC pins are 2 mm diameter, with 3.5 ±1 mm projection. The pin-column spacing is 76 mm, input-pin spacing 6.75 mm and output-pin spacing 5.5 mm. The drawing also gives 5.7, 5 and 40.75 mm coordinate references; use the complete footprint rather than a mirrored top view. PCB soldering limits: wave soldering 265°C for 5 seconds maximum; manual soldering 390°C for 3 seconds maximum. Use the model-specific installation drawing and the manufacturer installation instructions referenced in the PDF. The catalogue does not specify a separate mating-connector, bracket or wiring-kit order code for this version; it also does not give terminal torque or wire-gauge values. Select installation hardware for the actual mounting and electrical conditions. Reference mass and reliability Catalogue packing reference per unit 197 g, from the explicit unit value in the PACKING entry on PDF page 30. This is not a measured net weight or shipping-package weight. MTBF, catalogue minimum estimates 4548.9 thousand hours, Telcordia SR-332 (Bellcore); 570.5 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer datasheet warranty 3 years.

  • MPM-90-24

    MEAN WELL MPM-90 series: PCB-mount medical AC/DC power module - MPM-90-24

    MEAN WELL MPM-90-24 is a PCB-mount medical AC/DC power module delivering 24 V DC at 3.75 A (90 W) by convection, with a conditional 4.13 A / 99 W peak rating for up to 10 seconds. It accepts 80–264 V AC or 113–370 V DC and provides Class II insulation with 2 × MOPP; BF application suitability depends on the completed system. Product Datasheet Download MEAN WELL MPM-90 Datasheet (PDF) The MPM-90 section is on PDF pages 29, 30, 31, 32. Refer to the complete mechanical drawings and notes when planning installation. Model and mounting Complete model MPM-90-24 Product type Isolated AC/DC medical power module, single 24 V DC output Mounting configuration No suffix: PCB mounting version. Model code MPM identifies the series; 90 identifies the family; 24 identifies nominal output voltage. Use the actual continuous and peak ratings below. Output and peak load Nominal DC output 24 V Continuous convection rating 3.75 A; 90 W Peak rating 4.13 A; 99 W, for up to 10 seconds under the duty and average-power limits. Ripple and noise, maximum 200 mV peak-to-peak Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±0.5% Minimum load No minimum load required. Peak operation is limited to a maximum 33% duty cycle within every 30-second interval, and average output power must not exceed the continuous rated power. The peak duration, duty cycle, average power and thermal/input derating conditions all apply together. Ripple and noise are measured with a 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Unless separately stated, catalogue parameters use 230 V AC input, rated load and 25°C ambient. Input, efficiency and timing Input range 80–264 V AC or 113–370 V DC; output derating applies at low input. AC frequency 47–63 Hz Typical efficiency 93% at the catalogue reference conditions. Typical AC current 1.9 A at 115 V AC; 1.1 A at 230 V AC. Typical cold-start inrush 30 A at 115 V AC; 65 A at 230 V AC. Set-up / rise time 1000 ms / 30 ms at 230 V AC or 115 V AC, full load. Typical hold-up time 30 ms at 230 V AC; 10 ms at 115 V AC, full load. No-load input power Less than 0.1 W. The 60 Hz input-voltage curve on PDF page 31 permits 80% load at 80 V AC, rising to 100% at 100 V AC and remaining at 100% through 264 V AC. Apply this together with the ambient-temperature curve. The block diagram identifies a 70 kHz switching frequency. Protection Short circuit / overload Overload threshold: 115–160% of rated output power. Hiccup protection recovers automatically after the fault is removed. Overvoltage 25.2–32.4 V; output shuts down. Re-power the unit to recover. Overtemperature Output shuts down; re-power the unit to recover. Temperature, cooling and altitude Working ambient range -30 to +80°C, subject to the applicable load derating curve. Storage temperature -40 to +85°C. Working humidity 20–90% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Maximum operating altitude / overvoltage category 4000 m / OVC II. The horizontal-mounting curve allows 100% load from -30°C to 50°C at 100 V AC, or to 55°C at 230 V AC. Follow the respective sloping curve above those temperatures; both show 50% load at 70°C and 25% at 80°C. Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this convection-cooled module. A generic 5°C/1000 m note for fan-equipped models does not identify a fan in this version. The upper ambient limit is not a full-load rating. Medical isolation and integration Insulation class Class II, double insulation; no functional-ground terminal. Primary-to-secondary protection 2 × MOPP (means of patient protection). Input-to-output withstand voltage 4 kV AC. Input-to-output insulation resistance 100 MΩ at 500 V DC, 25°C and 70% RH. Maximum touch current Less than 100 µA at 264 V AC, measured from primary input to DC output. Suitable for BF (body-floating, patient-contact) applications only with appropriate system consideration. The module is a component, so the completed medical equipment and its applied-part isolation must be assessed as a system. The specification lists IEC 60601-1:2005+A1; TUV BS EN/EN 60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; and EAC TP TC 004 approvals. Design reference to BS EN/EN 60335-1 is by request and is not a blanket approval for every delivered unit. Catalogue application examples include portable medical devices, mobile clinical workstations, medical computer monitors and medical examination instruments. EMC Conducted and radiated emissions BS EN/EN 55011 (CISPR 11), Class B; the family feature states Class B without additional components. Harmonic current BS EN/EN 61000-3-2, Class A. Voltage flicker BS EN/EN 61000-3-3 is listed; no separate class or level is stated. Immunity standards BS EN/EN 55035 and BS EN/EN 60601-1-2. Immunity test entries: BS EN/EN 61000-4-2, ESD Level 4, 15 kV air and 8 kV contact; 61000-4-3, RF Level 3, 10 V/m from 80 MHz to 2.7 GHz, plus Table 9 fields of 9–28 V/m from 385 MHz to 5.78 GHz; 61000-4-4, EFT Level 3, 2 kV; 61000-4-5, surge Level 3, 1 kV line-to-line; 61000-4-6, conducted Level 3, 10 V; and 61000-4-8, magnetic field Level 4, 30 A/m. The BS EN/EN 61000-4-11 entries are greater than 95% dip for 0.5 periods, 30% dip for 25 periods, and greater than 95% interruption for 250 periods. These component test entries do not replace final-equipment EMC verification. Dimensions, terminals and installation Overall dimensions, L × W × H 87 × 52 × 29.5 mm Catalogue case / general tolerance IRM60 / ±1 mm unless otherwise marked. Connection method PCB pins marked AC/N, AC/L, −Vo and +Vo; bottom-view footprint. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Use the bottom-view PCB footprint on PDF page 32: AC/N and AC/L are the two input pins on the right of that drawing; −Vo and +Vo are the two output pins on the left. AC pins are 1 mm diameter and DC pins are 2 mm diameter, with 3.5 ±1 mm projection. The pin-column spacing is 76 mm, input-pin spacing 6.75 mm and output-pin spacing 5.5 mm. The drawing also gives 5.7, 5 and 40.75 mm coordinate references; use the complete footprint rather than a mirrored top view. PCB soldering limits: wave soldering 265°C for 5 seconds maximum; manual soldering 390°C for 3 seconds maximum. Use the model-specific installation drawing and the manufacturer installation instructions referenced in the PDF. The catalogue does not specify a separate mating-connector, bracket or wiring-kit order code for this version; it also does not give terminal torque or wire-gauge values. Select installation hardware for the actual mounting and electrical conditions. Reference mass and reliability Catalogue packing reference per unit 197 g, from the explicit unit value in the PACKING entry on PDF page 30. This is not a measured net weight or shipping-package weight. MTBF, catalogue minimum estimates 4548.9 thousand hours, Telcordia SR-332 (Bellcore); 570.5 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer datasheet warranty 3 years.

  • MPM-90-15

    MEAN WELL MPM-90 series: PCB-mount medical AC/DC power module - MPM-90-15

    MEAN WELL MPM-90-15 is a PCB-mount medical AC/DC power module delivering 15 V DC at 5.67 A (85.05 W) by convection, with a conditional 6.23 A / 93.5 W peak rating for up to 10 seconds. It accepts 80–264 V AC or 113–370 V DC and provides Class II insulation with 2 × MOPP; BF application suitability depends on the completed system. Product Datasheet Download MEAN WELL MPM-90 Datasheet (PDF) The MPM-90 section is on PDF pages 29, 30, 31, 32. Refer to the complete mechanical drawings and notes when planning installation. Model and mounting Complete model MPM-90-15 Product type Isolated AC/DC medical power module, single 15 V DC output Mounting configuration No suffix: PCB mounting version. Model code MPM identifies the series; 90 identifies the family; 15 identifies nominal output voltage. Use the actual continuous and peak ratings below. Output and peak load Nominal DC output 15 V Continuous convection rating 5.67 A; 85.05 W Peak rating 6.23 A; 93.5 W, for up to 10 seconds under the duty and average-power limits. Ripple and noise, maximum 150 mV peak-to-peak Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±0.5% Minimum load No minimum load required. Peak operation is limited to a maximum 33% duty cycle within every 30-second interval, and average output power must not exceed the continuous rated power. The peak duration, duty cycle, average power and thermal/input derating conditions all apply together. Ripple and noise are measured with a 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Unless separately stated, catalogue parameters use 230 V AC input, rated load and 25°C ambient. Input, efficiency and timing Input range 80–264 V AC or 113–370 V DC; output derating applies at low input. AC frequency 47–63 Hz Typical efficiency 92.5% at the catalogue reference conditions. Typical AC current 1.9 A at 115 V AC; 1.1 A at 230 V AC. Typical cold-start inrush 30 A at 115 V AC; 65 A at 230 V AC. Set-up / rise time 1000 ms / 30 ms at 230 V AC or 115 V AC, full load. Typical hold-up time 30 ms at 230 V AC; 10 ms at 115 V AC, full load. No-load input power Less than 0.1 W. The 60 Hz input-voltage curve on PDF page 31 permits 80% load at 80 V AC, rising to 100% at 100 V AC and remaining at 100% through 264 V AC. Apply this together with the ambient-temperature curve. The block diagram identifies a 70 kHz switching frequency. Protection Short circuit / overload Overload threshold: 115–160% of rated output power. Hiccup protection recovers automatically after the fault is removed. Overvoltage 15.8–20.3 V; output shuts down. Re-power the unit to recover. Overtemperature Output shuts down; re-power the unit to recover. Temperature, cooling and altitude Working ambient range -30 to +80°C, subject to the applicable load derating curve. Storage temperature -40 to +85°C. Working humidity 20–90% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Maximum operating altitude / overvoltage category 4000 m / OVC II. The horizontal-mounting curve allows 100% load from -30°C to 50°C at 100 V AC, or to 55°C at 230 V AC. Follow the respective sloping curve above those temperatures; both show 50% load at 70°C and 25% at 80°C. Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this convection-cooled module. A generic 5°C/1000 m note for fan-equipped models does not identify a fan in this version. The upper ambient limit is not a full-load rating. Medical isolation and integration Insulation class Class II, double insulation; no functional-ground terminal. Primary-to-secondary protection 2 × MOPP (means of patient protection). Input-to-output withstand voltage 4 kV AC. Input-to-output insulation resistance 100 MΩ at 500 V DC, 25°C and 70% RH. Maximum touch current Less than 100 µA at 264 V AC, measured from primary input to DC output. Suitable for BF (body-floating, patient-contact) applications only with appropriate system consideration. The module is a component, so the completed medical equipment and its applied-part isolation must be assessed as a system. The specification lists IEC 60601-1:2005+A1; TUV BS EN/EN 60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; and EAC TP TC 004 approvals. Design reference to BS EN/EN 60335-1 is by request and is not a blanket approval for every delivered unit. Catalogue application examples include portable medical devices, mobile clinical workstations, medical computer monitors and medical examination instruments. EMC Conducted and radiated emissions BS EN/EN 55011 (CISPR 11), Class B; the family feature states Class B without additional components. Harmonic current BS EN/EN 61000-3-2, Class A. Voltage flicker BS EN/EN 61000-3-3 is listed; no separate class or level is stated. Immunity standards BS EN/EN 55035 and BS EN/EN 60601-1-2. Immunity test entries: BS EN/EN 61000-4-2, ESD Level 4, 15 kV air and 8 kV contact; 61000-4-3, RF Level 3, 10 V/m from 80 MHz to 2.7 GHz, plus Table 9 fields of 9–28 V/m from 385 MHz to 5.78 GHz; 61000-4-4, EFT Level 3, 2 kV; 61000-4-5, surge Level 3, 1 kV line-to-line; 61000-4-6, conducted Level 3, 10 V; and 61000-4-8, magnetic field Level 4, 30 A/m. The BS EN/EN 61000-4-11 entries are greater than 95% dip for 0.5 periods, 30% dip for 25 periods, and greater than 95% interruption for 250 periods. These component test entries do not replace final-equipment EMC verification. Dimensions, terminals and installation Overall dimensions, L × W × H 87 × 52 × 29.5 mm Catalogue case / general tolerance IRM60 / ±1 mm unless otherwise marked. Connection method PCB pins marked AC/N, AC/L, −Vo and +Vo; bottom-view footprint. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Use the bottom-view PCB footprint on PDF page 32: AC/N and AC/L are the two input pins on the right of that drawing; −Vo and +Vo are the two output pins on the left. AC pins are 1 mm diameter and DC pins are 2 mm diameter, with 3.5 ±1 mm projection. The pin-column spacing is 76 mm, input-pin spacing 6.75 mm and output-pin spacing 5.5 mm. The drawing also gives 5.7, 5 and 40.75 mm coordinate references; use the complete footprint rather than a mirrored top view. PCB soldering limits: wave soldering 265°C for 5 seconds maximum; manual soldering 390°C for 3 seconds maximum. Use the model-specific installation drawing and the manufacturer installation instructions referenced in the PDF. The catalogue does not specify a separate mating-connector, bracket or wiring-kit order code for this version; it also does not give terminal torque or wire-gauge values. Select installation hardware for the actual mounting and electrical conditions. Reference mass and reliability Catalogue packing reference per unit 197 g, from the explicit unit value in the PACKING entry on PDF page 30. This is not a measured net weight or shipping-package weight. MTBF, catalogue minimum estimates 4548.9 thousand hours, Telcordia SR-332 (Bellcore); 570.5 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer datasheet warranty 3 years.

  • MPM-90-12

    MEAN WELL MPM-90 series: PCB-mount medical AC/DC power module - MPM-90-12

    MEAN WELL MPM-90-12 is a PCB-mount medical AC/DC power module delivering 12 V DC at 6.7 A (80.4 W) by convection, with a conditional 7.37 A / 88.4 W peak rating for up to 10 seconds. It accepts 80–264 V AC or 113–370 V DC and provides Class II insulation with 2 × MOPP; BF application suitability depends on the completed system. Product Datasheet Download MEAN WELL MPM-90 Datasheet (PDF) The MPM-90 section is on PDF pages 29, 30, 31, 32. Refer to the complete mechanical drawings and notes when planning installation. Model and mounting Complete model MPM-90-12 Product type Isolated AC/DC medical power module, single 12 V DC output Mounting configuration No suffix: PCB mounting version. Model code MPM identifies the series; 90 identifies the family; 12 identifies nominal output voltage. Use the actual continuous and peak ratings below. Output and peak load Nominal DC output 12 V Continuous convection rating 6.7 A; 80.4 W Peak rating 7.37 A; 88.4 W, for up to 10 seconds under the duty and average-power limits. Ripple and noise, maximum 120 mV peak-to-peak Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±1.0% Minimum load No minimum load required. Peak operation is limited to a maximum 33% duty cycle within every 30-second interval, and average output power must not exceed the continuous rated power. The peak duration, duty cycle, average power and thermal/input derating conditions all apply together. Ripple and noise are measured with a 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Unless separately stated, catalogue parameters use 230 V AC input, rated load and 25°C ambient. Input, efficiency and timing Input range 80–264 V AC or 113–370 V DC; output derating applies at low input. AC frequency 47–63 Hz Typical efficiency 92% at the catalogue reference conditions. Typical AC current 1.9 A at 115 V AC; 1.1 A at 230 V AC. Typical cold-start inrush 30 A at 115 V AC; 65 A at 230 V AC. Set-up / rise time 1000 ms / 30 ms at 230 V AC or 115 V AC, full load. Typical hold-up time 30 ms at 230 V AC; 10 ms at 115 V AC, full load. No-load input power Less than 0.1 W. The 60 Hz input-voltage curve on PDF page 31 permits 80% load at 80 V AC, rising to 100% at 100 V AC and remaining at 100% through 264 V AC. Apply this together with the ambient-temperature curve. The block diagram identifies a 70 kHz switching frequency. Protection Short circuit / overload Overload threshold: 115–160% of rated output power. Hiccup protection recovers automatically after the fault is removed. Overvoltage 12.6–16.2 V; output shuts down. Re-power the unit to recover. Overtemperature Output shuts down; re-power the unit to recover. Temperature, cooling and altitude Working ambient range -30 to +80°C, subject to the applicable load derating curve. Storage temperature -40 to +85°C. Working humidity 20–90% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Maximum operating altitude / overvoltage category 4000 m / OVC II. The horizontal-mounting curve allows 100% load from -30°C to 50°C at 100 V AC, or to 55°C at 230 V AC. Follow the respective sloping curve above those temperatures; both show 50% load at 70°C and 25% at 80°C. Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this convection-cooled module. A generic 5°C/1000 m note for fan-equipped models does not identify a fan in this version. The upper ambient limit is not a full-load rating. Medical isolation and integration Insulation class Class II, double insulation; no functional-ground terminal. Primary-to-secondary protection 2 × MOPP (means of patient protection). Input-to-output withstand voltage 4 kV AC. Input-to-output insulation resistance 100 MΩ at 500 V DC, 25°C and 70% RH. Maximum touch current Less than 100 µA at 264 V AC, measured from primary input to DC output. Suitable for BF (body-floating, patient-contact) applications only with appropriate system consideration. The module is a component, so the completed medical equipment and its applied-part isolation must be assessed as a system. The specification lists IEC 60601-1:2005+A1; TUV BS EN/EN 60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; and EAC TP TC 004 approvals. Design reference to BS EN/EN 60335-1 is by request and is not a blanket approval for every delivered unit. Catalogue application examples include portable medical devices, mobile clinical workstations, medical computer monitors and medical examination instruments. EMC Conducted and radiated emissions BS EN/EN 55011 (CISPR 11), Class B; the family feature states Class B without additional components. Harmonic current BS EN/EN 61000-3-2, Class A. Voltage flicker BS EN/EN 61000-3-3 is listed; no separate class or level is stated. Immunity standards BS EN/EN 55035 and BS EN/EN 60601-1-2. Immunity test entries: BS EN/EN 61000-4-2, ESD Level 4, 15 kV air and 8 kV contact; 61000-4-3, RF Level 3, 10 V/m from 80 MHz to 2.7 GHz, plus Table 9 fields of 9–28 V/m from 385 MHz to 5.78 GHz; 61000-4-4, EFT Level 3, 2 kV; 61000-4-5, surge Level 3, 1 kV line-to-line; 61000-4-6, conducted Level 3, 10 V; and 61000-4-8, magnetic field Level 4, 30 A/m. The BS EN/EN 61000-4-11 entries are greater than 95% dip for 0.5 periods, 30% dip for 25 periods, and greater than 95% interruption for 250 periods. These component test entries do not replace final-equipment EMC verification. Dimensions, terminals and installation Overall dimensions, L × W × H 87 × 52 × 29.5 mm Catalogue case / general tolerance IRM60 / ±1 mm unless otherwise marked. Connection method PCB pins marked AC/N, AC/L, −Vo and +Vo; bottom-view footprint. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Use the bottom-view PCB footprint on PDF page 32: AC/N and AC/L are the two input pins on the right of that drawing; −Vo and +Vo are the two output pins on the left. AC pins are 1 mm diameter and DC pins are 2 mm diameter, with 3.5 ±1 mm projection. The pin-column spacing is 76 mm, input-pin spacing 6.75 mm and output-pin spacing 5.5 mm. The drawing also gives 5.7, 5 and 40.75 mm coordinate references; use the complete footprint rather than a mirrored top view. PCB soldering limits: wave soldering 265°C for 5 seconds maximum; manual soldering 390°C for 3 seconds maximum. Use the model-specific installation drawing and the manufacturer installation instructions referenced in the PDF. The catalogue does not specify a separate mating-connector, bracket or wiring-kit order code for this version; it also does not give terminal torque or wire-gauge values. Select installation hardware for the actual mounting and electrical conditions. Reference mass and reliability Catalogue packing reference per unit 197 g, from the explicit unit value in the PACKING entry on PDF page 30. This is not a measured net weight or shipping-package weight. MTBF, catalogue minimum estimates 4548.9 thousand hours, Telcordia SR-332 (Bellcore); 570.5 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer datasheet warranty 3 years.

  • MPM-65-48ST

    MEAN WELL MPM-65 series: screw-terminal medical AC/DC power module - MPM-65-48ST

    MEAN WELL MPM-65-48ST is a screw-terminal medical AC/DC power module delivering 48 V DC at 1.36 A (65.3 W) by convection, with a conditional 1.49 A / 71.5 W peak rating for up to 10 seconds. It accepts 80–264 V AC or 113–370 V DC and provides Class II insulation with 2 × MOPP; BF application suitability depends on the completed system. Product Datasheet Download MEAN WELL MPM-65 Datasheet (PDF) The MPM-65 section is on PDF pages 25, 26, 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and mounting Complete model MPM-65-48ST Product type Isolated AC/DC medical power module, single 48 V DC output Mounting configuration ST suffix: screw-terminal mounting version. Model code MPM identifies the series; 65 identifies the family; 48 identifies nominal output voltage. Use the actual continuous and peak ratings below. Output and peak load Nominal DC output 48 V Continuous convection rating 1.36 A; 65.3 W Peak rating 1.49 A; 71.5 W, for up to 10 seconds under the duty and average-power limits. Ripple and noise, maximum 240 mV peak-to-peak Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±0.5% Minimum load No minimum load required. Peak operation is limited to a maximum 33% duty cycle within every 30-second interval, and average output power must not exceed the continuous rated power. The peak duration, duty cycle, average power and thermal/input derating conditions all apply together. Ripple and noise are measured with a 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Unless separately stated, catalogue parameters use 230 V AC input, rated load and 25°C ambient. Input, efficiency and timing Input range 80–264 V AC or 113–370 V DC; output derating applies at low input. AC frequency 47–63 Hz Typical efficiency 92% at the catalogue reference conditions. Typical AC current 1.5 A at 115 V AC; 1 A at 230 V AC. Typical cold-start inrush 30 A at 115 V AC; 65 A at 230 V AC. Set-up / rise time 1000 ms / 30 ms at 230 V AC or 115 V AC, full load. Typical hold-up time 50 ms at 230 V AC; 12 ms at 115 V AC, full load. No-load input power Less than 0.1 W. The 60 Hz input-voltage curve on PDF page 27 permits 80% load at 80 V AC, rising to 100% at 100 V AC and remaining at 100% through 264 V AC. Apply this together with the ambient-temperature curve. The block diagram identifies a 70 kHz switching frequency. Protection Short circuit / overload Overload threshold: 115–135% of rated output power. Hiccup protection recovers automatically after the fault is removed. Overvoltage 50.4–64.8 V; output shuts down. Re-power the unit to recover. Overtemperature Output shuts down; re-power the unit to recover. Temperature, cooling and altitude Working ambient range -30 to +80°C, subject to the applicable load derating curve. Storage temperature -40 to +85°C. Working humidity 20–90% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Maximum operating altitude / overvoltage category 4000 m / OVC II. For this 48 V version, the horizontal-mounting curve allows 100% load from -30°C to 55°C, then requires derating: 80% at 60°C, 50% at 70°C and 30% at 80°C. Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this convection-cooled module. A generic 5°C/1000 m note for fan-equipped models does not identify a fan in this version. The upper ambient limit is not a full-load rating. Medical isolation and integration Insulation class Class II, double insulation; no functional-ground terminal. Primary-to-secondary protection 2 × MOPP (means of patient protection). Input-to-output withstand voltage 4 kV AC. Input-to-output insulation resistance 100 MΩ at 500 V DC, 25°C and 70% RH. Maximum touch current Less than 100 µA at 264 V AC, measured from primary input to DC output. Suitable for BF (body-floating, patient-contact) applications only with appropriate system consideration. The module is a component, so the completed medical equipment and its applied-part isolation must be assessed as a system. The specification lists IEC 60601-1:2005+A1; TUV BS EN/EN 60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; and EAC TP TC 004 approvals. Design reference to BS EN/EN 60335-1 is by request and is not a blanket approval for every delivered unit. Catalogue application examples include portable medical devices, mobile clinical workstations, medical computer monitors and medical examination instruments. EMC Conducted and radiated emissions BS EN/EN 55011 (CISPR 11), Class B; the family feature states Class B without additional components. Harmonic current BS EN/EN 61000-3-2, Class A. Voltage flicker BS EN/EN 61000-3-3 is listed; no separate class or level is stated. Immunity standards BS EN/EN 55035 and BS EN/EN 60601-1-2. Immunity test entries: BS EN/EN 61000-4-2, ESD Level 4, 15 kV air and 8 kV contact; 61000-4-3, RF Level 3, 10 V/m from 80 MHz to 2.7 GHz, plus Table 9 fields of 9–28 V/m from 385 MHz to 5.78 GHz; 61000-4-4, EFT Level 3, 2 kV; 61000-4-5, surge Level 3, 1 kV line-to-line; 61000-4-6, conducted Level 3, 10 V; and 61000-4-8, magnetic field Level 4, 30 A/m. The BS EN/EN 61000-4-11 entries are greater than 95% dip for 0.5 periods, 30% dip for 25 periods, and greater than 95% interruption for 250 periods. These component test entries do not replace final-equipment EMC verification. Dimensions, terminals and installation Overall dimensions, L × W × H 109 × 52 × 33.5 mm Catalogue case / general tolerance IRM60 / ±1 mm unless otherwise marked. Connection method Screw terminals marked AC/N, AC/L, −Vo and +Vo. Vibration 10–500 Hz, 5 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. The top-view drawing on PDF page 28 labels the input terminals AC/N then AC/L from left to right. The output bank is −Vo, −Vo, +Vo, +Vo from left to right. Input terminal pitch is 7.5 mm and output pitch is 5 mm. Four 3.5 mm diameter mounting holes form the dimensioned 33 × 98 mm pattern. Overall height is 33.5 mm; the separate 6.7 mm side-view dimension is a drawing reference, not an additional overall height. Use the model-specific installation drawing and the manufacturer installation instructions referenced in the PDF. The catalogue does not specify a separate mating-connector, bracket or wiring-kit order code for this version; it also does not give terminal torque or wire-gauge values. Select installation hardware for the actual mounting and electrical conditions. Reference mass and reliability Catalogue packing reference per unit 216 g, from the explicit unit value in the PACKING entry on PDF page 26. This is not a measured net weight or shipping-package weight. MTBF, catalogue minimum estimates 5087.8 thousand hours, Telcordia SR-332 (Bellcore); 563.4 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer datasheet warranty 3 years.

  • MPM-65-24ST

    MEAN WELL MPM-65 series: screw-terminal medical AC/DC power module - MPM-65-24ST

    MEAN WELL MPM-65-24ST is a screw-terminal medical AC/DC power module delivering 24 V DC at 2.71 A (65 W) by convection, with a conditional 2.98 A / 71.5 W peak rating for up to 10 seconds. It accepts 80–264 V AC or 113–370 V DC and provides Class II insulation with 2 × MOPP; BF application suitability depends on the completed system. Product Datasheet Download MEAN WELL MPM-65 Datasheet (PDF) The MPM-65 section is on PDF pages 25, 26, 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and mounting Complete model MPM-65-24ST Product type Isolated AC/DC medical power module, single 24 V DC output Mounting configuration ST suffix: screw-terminal mounting version. Model code MPM identifies the series; 65 identifies the family; 24 identifies nominal output voltage. Use the actual continuous and peak ratings below. Output and peak load Nominal DC output 24 V Continuous convection rating 2.71 A; 65 W Peak rating 2.98 A; 71.5 W, for up to 10 seconds under the duty and average-power limits. Ripple and noise, maximum 200 mV peak-to-peak Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±0.5% Minimum load No minimum load required. Peak operation is limited to a maximum 33% duty cycle within every 30-second interval, and average output power must not exceed the continuous rated power. The peak duration, duty cycle, average power and thermal/input derating conditions all apply together. Ripple and noise are measured with a 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Unless separately stated, catalogue parameters use 230 V AC input, rated load and 25°C ambient. Input, efficiency and timing Input range 80–264 V AC or 113–370 V DC; output derating applies at low input. AC frequency 47–63 Hz Typical efficiency 93% at the catalogue reference conditions. Typical AC current 1.5 A at 115 V AC; 1 A at 230 V AC. Typical cold-start inrush 30 A at 115 V AC; 65 A at 230 V AC. Set-up / rise time 1000 ms / 30 ms at 230 V AC or 115 V AC, full load. Typical hold-up time 50 ms at 230 V AC; 12 ms at 115 V AC, full load. No-load input power Less than 0.1 W. The 60 Hz input-voltage curve on PDF page 27 permits 80% load at 80 V AC, rising to 100% at 100 V AC and remaining at 100% through 264 V AC. Apply this together with the ambient-temperature curve. The block diagram identifies a 70 kHz switching frequency. Protection Short circuit / overload Overload threshold: 115–135% of rated output power. Hiccup protection recovers automatically after the fault is removed. Overvoltage 25.2–32.4 V; output shuts down. Re-power the unit to recover. Overtemperature Output shuts down; re-power the unit to recover. Temperature, cooling and altitude Working ambient range -30 to +80°C, subject to the applicable load derating curve. Storage temperature -40 to +85°C. Working humidity 20–90% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Maximum operating altitude / overvoltage category 4000 m / OVC II. For this 24 V version, the horizontal-mounting curve allows 100% load from -30°C to 55°C, then requires derating: 80% at 60°C, 50% at 70°C and 30% at 80°C. Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this convection-cooled module. A generic 5°C/1000 m note for fan-equipped models does not identify a fan in this version. The upper ambient limit is not a full-load rating. Medical isolation and integration Insulation class Class II, double insulation; no functional-ground terminal. Primary-to-secondary protection 2 × MOPP (means of patient protection). Input-to-output withstand voltage 4 kV AC. Input-to-output insulation resistance 100 MΩ at 500 V DC, 25°C and 70% RH. Maximum touch current Less than 100 µA at 264 V AC, measured from primary input to DC output. Suitable for BF (body-floating, patient-contact) applications only with appropriate system consideration. The module is a component, so the completed medical equipment and its applied-part isolation must be assessed as a system. The specification lists IEC 60601-1:2005+A1; TUV BS EN/EN 60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; and EAC TP TC 004 approvals. Design reference to BS EN/EN 60335-1 is by request and is not a blanket approval for every delivered unit. Catalogue application examples include portable medical devices, mobile clinical workstations, medical computer monitors and medical examination instruments. EMC Conducted and radiated emissions BS EN/EN 55011 (CISPR 11), Class B; the family feature states Class B without additional components. Harmonic current BS EN/EN 61000-3-2, Class A. Voltage flicker BS EN/EN 61000-3-3 is listed; no separate class or level is stated. Immunity standards BS EN/EN 55035 and BS EN/EN 60601-1-2. Immunity test entries: BS EN/EN 61000-4-2, ESD Level 4, 15 kV air and 8 kV contact; 61000-4-3, RF Level 3, 10 V/m from 80 MHz to 2.7 GHz, plus Table 9 fields of 9–28 V/m from 385 MHz to 5.78 GHz; 61000-4-4, EFT Level 3, 2 kV; 61000-4-5, surge Level 3, 1 kV line-to-line; 61000-4-6, conducted Level 3, 10 V; and 61000-4-8, magnetic field Level 4, 30 A/m. The BS EN/EN 61000-4-11 entries are greater than 95% dip for 0.5 periods, 30% dip for 25 periods, and greater than 95% interruption for 250 periods. These component test entries do not replace final-equipment EMC verification. Dimensions, terminals and installation Overall dimensions, L × W × H 109 × 52 × 33.5 mm Catalogue case / general tolerance IRM60 / ±1 mm unless otherwise marked. Connection method Screw terminals marked AC/N, AC/L, −Vo and +Vo. Vibration 10–500 Hz, 5 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. The top-view drawing on PDF page 28 labels the input terminals AC/N then AC/L from left to right. The output bank is −Vo, −Vo, +Vo, +Vo from left to right. Input terminal pitch is 7.5 mm and output pitch is 5 mm. Four 3.5 mm diameter mounting holes form the dimensioned 33 × 98 mm pattern. Overall height is 33.5 mm; the separate 6.7 mm side-view dimension is a drawing reference, not an additional overall height. Use the model-specific installation drawing and the manufacturer installation instructions referenced in the PDF. The catalogue does not specify a separate mating-connector, bracket or wiring-kit order code for this version; it also does not give terminal torque or wire-gauge values. Select installation hardware for the actual mounting and electrical conditions. Reference mass and reliability Catalogue packing reference per unit 216 g, from the explicit unit value in the PACKING entry on PDF page 26. This is not a measured net weight or shipping-package weight. MTBF, catalogue minimum estimates 5087.8 thousand hours, Telcordia SR-332 (Bellcore); 563.4 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer datasheet warranty 3 years.

  • MPM-65-15ST

    MEAN WELL MPM-65 series: screw-terminal medical AC/DC power module - MPM-65-15ST

    MEAN WELL MPM-65-15ST is a screw-terminal medical AC/DC power module delivering 15 V DC at 4.33 A (65 W) by convection, with a conditional 4.77 A / 71.6 W peak rating for up to 10 seconds. It accepts 80–264 V AC or 113–370 V DC and provides Class II insulation with 2 × MOPP; BF application suitability depends on the completed system. Product Datasheet Download MEAN WELL MPM-65 Datasheet (PDF) The MPM-65 section is on PDF pages 25, 26, 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and mounting Complete model MPM-65-15ST Product type Isolated AC/DC medical power module, single 15 V DC output Mounting configuration ST suffix: screw-terminal mounting version. Model code MPM identifies the series; 65 identifies the family; 15 identifies nominal output voltage. Use the actual continuous and peak ratings below. Output and peak load Nominal DC output 15 V Continuous convection rating 4.33 A; 65 W Peak rating 4.77 A; 71.6 W, for up to 10 seconds under the duty and average-power limits. Ripple and noise, maximum 120 mV peak-to-peak Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±0.5% Minimum load No minimum load required. Peak operation is limited to a maximum 33% duty cycle within every 30-second interval, and average output power must not exceed the continuous rated power. The peak duration, duty cycle, average power and thermal/input derating conditions all apply together. Ripple and noise are measured with a 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Unless separately stated, catalogue parameters use 230 V AC input, rated load and 25°C ambient. Input, efficiency and timing Input range 80–264 V AC or 113–370 V DC; output derating applies at low input. AC frequency 47–63 Hz Typical efficiency 92.5% at the catalogue reference conditions. Typical AC current 1.5 A at 115 V AC; 1 A at 230 V AC. Typical cold-start inrush 30 A at 115 V AC; 65 A at 230 V AC. Set-up / rise time 1000 ms / 30 ms at 230 V AC or 115 V AC, full load. Typical hold-up time 50 ms at 230 V AC; 12 ms at 115 V AC, full load. No-load input power Less than 0.1 W. The 60 Hz input-voltage curve on PDF page 27 permits 80% load at 80 V AC, rising to 100% at 100 V AC and remaining at 100% through 264 V AC. Apply this together with the ambient-temperature curve. The block diagram identifies a 70 kHz switching frequency. Protection Short circuit / overload Overload threshold: 115–135% of rated output power. Hiccup protection recovers automatically after the fault is removed. Overvoltage 15.8–20.3 V; output shuts down. Re-power the unit to recover. Overtemperature Output shuts down; re-power the unit to recover. Temperature, cooling and altitude Working ambient range -30 to +80°C, subject to the applicable load derating curve. Storage temperature -40 to +85°C. Working humidity 20–90% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Maximum operating altitude / overvoltage category 4000 m / OVC II. For this 15 V version, the horizontal-mounting curve allows 100% load from -30°C to 50°C, then requires derating: 80% at 60°C, 50% at 70°C and 30% at 80°C. Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this convection-cooled module. A generic 5°C/1000 m note for fan-equipped models does not identify a fan in this version. The upper ambient limit is not a full-load rating. Medical isolation and integration Insulation class Class II, double insulation; no functional-ground terminal. Primary-to-secondary protection 2 × MOPP (means of patient protection). Input-to-output withstand voltage 4 kV AC. Input-to-output insulation resistance 100 MΩ at 500 V DC, 25°C and 70% RH. Maximum touch current Less than 100 µA at 264 V AC, measured from primary input to DC output. Suitable for BF (body-floating, patient-contact) applications only with appropriate system consideration. The module is a component, so the completed medical equipment and its applied-part isolation must be assessed as a system. The specification lists IEC 60601-1:2005+A1; TUV BS EN/EN 60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; and EAC TP TC 004 approvals. Design reference to BS EN/EN 60335-1 is by request and is not a blanket approval for every delivered unit. Catalogue application examples include portable medical devices, mobile clinical workstations, medical computer monitors and medical examination instruments. EMC Conducted and radiated emissions BS EN/EN 55011 (CISPR 11), Class B; the family feature states Class B without additional components. Harmonic current BS EN/EN 61000-3-2, Class A. Voltage flicker BS EN/EN 61000-3-3 is listed; no separate class or level is stated. Immunity standards BS EN/EN 55035 and BS EN/EN 60601-1-2. Immunity test entries: BS EN/EN 61000-4-2, ESD Level 4, 15 kV air and 8 kV contact; 61000-4-3, RF Level 3, 10 V/m from 80 MHz to 2.7 GHz, plus Table 9 fields of 9–28 V/m from 385 MHz to 5.78 GHz; 61000-4-4, EFT Level 3, 2 kV; 61000-4-5, surge Level 3, 1 kV line-to-line; 61000-4-6, conducted Level 3, 10 V; and 61000-4-8, magnetic field Level 4, 30 A/m. The BS EN/EN 61000-4-11 entries are greater than 95% dip for 0.5 periods, 30% dip for 25 periods, and greater than 95% interruption for 250 periods. These component test entries do not replace final-equipment EMC verification. Dimensions, terminals and installation Overall dimensions, L × W × H 109 × 52 × 33.5 mm Catalogue case / general tolerance IRM60 / ±1 mm unless otherwise marked. Connection method Screw terminals marked AC/N, AC/L, −Vo and +Vo. Vibration 10–500 Hz, 5 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. The top-view drawing on PDF page 28 labels the input terminals AC/N then AC/L from left to right. The output bank is −Vo, −Vo, +Vo, +Vo from left to right. Input terminal pitch is 7.5 mm and output pitch is 5 mm. Four 3.5 mm diameter mounting holes form the dimensioned 33 × 98 mm pattern. Overall height is 33.5 mm; the separate 6.7 mm side-view dimension is a drawing reference, not an additional overall height. Use the model-specific installation drawing and the manufacturer installation instructions referenced in the PDF. The catalogue does not specify a separate mating-connector, bracket or wiring-kit order code for this version; it also does not give terminal torque or wire-gauge values. Select installation hardware for the actual mounting and electrical conditions. Reference mass and reliability Catalogue packing reference per unit 216 g, from the explicit unit value in the PACKING entry on PDF page 26. This is not a measured net weight or shipping-package weight. MTBF, catalogue minimum estimates 5087.8 thousand hours, Telcordia SR-332 (Bellcore); 563.4 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer datasheet warranty 3 years.

  • MPM-65-12ST

    MEAN WELL MPM-65 series: screw-terminal medical AC/DC power module - MPM-65-12ST

    MEAN WELL MPM-65-12ST is a screw-terminal medical AC/DC power module delivering 12 V DC at 5.42 A (65 W) by convection, with a conditional 5.96 A / 71.5 W peak rating for up to 10 seconds. It accepts 80–264 V AC or 113–370 V DC and provides Class II insulation with 2 × MOPP; BF application suitability depends on the completed system. Product Datasheet Download MEAN WELL MPM-65 Datasheet (PDF) The MPM-65 section is on PDF pages 25, 26, 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and mounting Complete model MPM-65-12ST Product type Isolated AC/DC medical power module, single 12 V DC output Mounting configuration ST suffix: screw-terminal mounting version. Model code MPM identifies the series; 65 identifies the family; 12 identifies nominal output voltage. Use the actual continuous and peak ratings below. Output and peak load Nominal DC output 12 V Continuous convection rating 5.42 A; 65 W Peak rating 5.96 A; 71.5 W, for up to 10 seconds under the duty and average-power limits. Ripple and noise, maximum 120 mV peak-to-peak Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±1.0% Minimum load No minimum load required. Peak operation is limited to a maximum 33% duty cycle within every 30-second interval, and average output power must not exceed the continuous rated power. The peak duration, duty cycle, average power and thermal/input derating conditions all apply together. Ripple and noise are measured with a 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Unless separately stated, catalogue parameters use 230 V AC input, rated load and 25°C ambient. Input, efficiency and timing Input range 80–264 V AC or 113–370 V DC; output derating applies at low input. AC frequency 47–63 Hz Typical efficiency 92.5% at the catalogue reference conditions. Typical AC current 1.5 A at 115 V AC; 1 A at 230 V AC. Typical cold-start inrush 30 A at 115 V AC; 65 A at 230 V AC. Set-up / rise time 1000 ms / 30 ms at 230 V AC or 115 V AC, full load. Typical hold-up time 50 ms at 230 V AC; 12 ms at 115 V AC, full load. No-load input power Less than 0.1 W. The 60 Hz input-voltage curve on PDF page 27 permits 80% load at 80 V AC, rising to 100% at 100 V AC and remaining at 100% through 264 V AC. Apply this together with the ambient-temperature curve. The block diagram identifies a 70 kHz switching frequency. Protection Short circuit / overload Overload threshold: 115–135% of rated output power. Hiccup protection recovers automatically after the fault is removed. Overvoltage 12.6–16.2 V; output shuts down. Re-power the unit to recover. Overtemperature Output shuts down; re-power the unit to recover. Temperature, cooling and altitude Working ambient range -30 to +80°C, subject to the applicable load derating curve. Storage temperature -40 to +85°C. Working humidity 20–90% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Maximum operating altitude / overvoltage category 4000 m / OVC II. For this 12 V version, the horizontal-mounting curve allows 100% load from -30°C to 50°C, then requires derating: 80% at 60°C, 50% at 70°C and 30% at 80°C. Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this convection-cooled module. A generic 5°C/1000 m note for fan-equipped models does not identify a fan in this version. The upper ambient limit is not a full-load rating. Medical isolation and integration Insulation class Class II, double insulation; no functional-ground terminal. Primary-to-secondary protection 2 × MOPP (means of patient protection). Input-to-output withstand voltage 4 kV AC. Input-to-output insulation resistance 100 MΩ at 500 V DC, 25°C and 70% RH. Maximum touch current Less than 100 µA at 264 V AC, measured from primary input to DC output. Suitable for BF (body-floating, patient-contact) applications only with appropriate system consideration. The module is a component, so the completed medical equipment and its applied-part isolation must be assessed as a system. The specification lists IEC 60601-1:2005+A1; TUV BS EN/EN 60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; and EAC TP TC 004 approvals. Design reference to BS EN/EN 60335-1 is by request and is not a blanket approval for every delivered unit. Catalogue application examples include portable medical devices, mobile clinical workstations, medical computer monitors and medical examination instruments. EMC Conducted and radiated emissions BS EN/EN 55011 (CISPR 11), Class B; the family feature states Class B without additional components. Harmonic current BS EN/EN 61000-3-2, Class A. Voltage flicker BS EN/EN 61000-3-3 is listed; no separate class or level is stated. Immunity standards BS EN/EN 55035 and BS EN/EN 60601-1-2. Immunity test entries: BS EN/EN 61000-4-2, ESD Level 4, 15 kV air and 8 kV contact; 61000-4-3, RF Level 3, 10 V/m from 80 MHz to 2.7 GHz, plus Table 9 fields of 9–28 V/m from 385 MHz to 5.78 GHz; 61000-4-4, EFT Level 3, 2 kV; 61000-4-5, surge Level 3, 1 kV line-to-line; 61000-4-6, conducted Level 3, 10 V; and 61000-4-8, magnetic field Level 4, 30 A/m. The BS EN/EN 61000-4-11 entries are greater than 95% dip for 0.5 periods, 30% dip for 25 periods, and greater than 95% interruption for 250 periods. These component test entries do not replace final-equipment EMC verification. Dimensions, terminals and installation Overall dimensions, L × W × H 109 × 52 × 33.5 mm Catalogue case / general tolerance IRM60 / ±1 mm unless otherwise marked. Connection method Screw terminals marked AC/N, AC/L, −Vo and +Vo. Vibration 10–500 Hz, 5 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. The top-view drawing on PDF page 28 labels the input terminals AC/N then AC/L from left to right. The output bank is −Vo, −Vo, +Vo, +Vo from left to right. Input terminal pitch is 7.5 mm and output pitch is 5 mm. Four 3.5 mm diameter mounting holes form the dimensioned 33 × 98 mm pattern. Overall height is 33.5 mm; the separate 6.7 mm side-view dimension is a drawing reference, not an additional overall height. Use the model-specific installation drawing and the manufacturer installation instructions referenced in the PDF. The catalogue does not specify a separate mating-connector, bracket or wiring-kit order code for this version; it also does not give terminal torque or wire-gauge values. Select installation hardware for the actual mounting and electrical conditions. Reference mass and reliability Catalogue packing reference per unit 216 g, from the explicit unit value in the PACKING entry on PDF page 26. This is not a measured net weight or shipping-package weight. MTBF, catalogue minimum estimates 5087.8 thousand hours, Telcordia SR-332 (Bellcore); 563.4 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer datasheet warranty 3 years.

  • MPM-65-5ST

    MEAN WELL MPM-65 series: screw-terminal medical AC/DC power module - MPM-65-5ST

    MEAN WELL MPM-65-5ST is a screw-terminal medical AC/DC power module delivering 5 V DC at 10 A (50 W) by convection, with a conditional 11 A / 55 W peak rating for up to 10 seconds. It accepts 80–264 V AC or 113–370 V DC and provides Class II insulation with 2 × MOPP; BF application suitability depends on the completed system. Product Datasheet Download MEAN WELL MPM-65 Datasheet (PDF) The MPM-65 section is on PDF pages 25, 26, 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and mounting Complete model MPM-65-5ST Product type Isolated AC/DC medical power module, single 5 V DC output Mounting configuration ST suffix: screw-terminal mounting version. Model code MPM identifies the series; 65 identifies the family; 5 identifies nominal output voltage. Use the actual continuous and peak ratings below. Output and peak load Nominal DC output 5 V Continuous convection rating 10 A; 50 W Peak rating 11 A; 55 W, for up to 10 seconds under the duty and average-power limits. Ripple and noise, maximum 80 mV peak-to-peak Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±1.0% Minimum load No minimum load required. Peak operation is limited to a maximum 33% duty cycle within every 30-second interval, and average output power must not exceed the continuous rated power. The peak duration, duty cycle, average power and thermal/input derating conditions all apply together. Ripple and noise are measured with a 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Unless separately stated, catalogue parameters use 230 V AC input, rated load and 25°C ambient. Input, efficiency and timing Input range 80–264 V AC or 113–370 V DC; output derating applies at low input. AC frequency 47–63 Hz Typical efficiency 86.5% at the catalogue reference conditions. Typical AC current 1.5 A at 115 V AC; 1 A at 230 V AC. Typical cold-start inrush 30 A at 115 V AC; 65 A at 230 V AC. Set-up / rise time 1000 ms / 30 ms at 230 V AC or 115 V AC, full load. Typical hold-up time 50 ms at 230 V AC; 12 ms at 115 V AC, full load. No-load input power Less than 0.1 W. The 60 Hz input-voltage curve on PDF page 27 permits 80% load at 80 V AC, rising to 100% at 100 V AC and remaining at 100% through 264 V AC. Apply this together with the ambient-temperature curve. The block diagram identifies a 70 kHz switching frequency. Protection Short circuit / overload Overload threshold: 115–135% of rated output power. Hiccup protection recovers automatically after the fault is removed. Overvoltage 5.3–7.2 V; output shuts down. Re-power the unit to recover. Overtemperature Output shuts down; re-power the unit to recover. Temperature, cooling and altitude Working ambient range -30 to +80°C, subject to the applicable load derating curve. Storage temperature -40 to +85°C. Working humidity 20–90% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Maximum operating altitude / overvoltage category 4000 m / OVC II. For this 5 V version, the horizontal-mounting curve allows 100% load from -30°C to 50°C, then requires derating: 80% at 60°C, 50% at 70°C and 30% at 80°C. Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this convection-cooled module. A generic 5°C/1000 m note for fan-equipped models does not identify a fan in this version. The upper ambient limit is not a full-load rating. Medical isolation and integration Insulation class Class II, double insulation; no functional-ground terminal. Primary-to-secondary protection 2 × MOPP (means of patient protection). Input-to-output withstand voltage 4 kV AC. Input-to-output insulation resistance 100 MΩ at 500 V DC, 25°C and 70% RH. Maximum touch current Less than 100 µA at 264 V AC, measured from primary input to DC output. Suitable for BF (body-floating, patient-contact) applications only with appropriate system consideration. The module is a component, so the completed medical equipment and its applied-part isolation must be assessed as a system. The specification lists IEC 60601-1:2005+A1; TUV BS EN/EN 60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; and EAC TP TC 004 approvals. Design reference to BS EN/EN 60335-1 is by request and is not a blanket approval for every delivered unit. Catalogue application examples include portable medical devices, mobile clinical workstations, medical computer monitors and medical examination instruments. EMC Conducted and radiated emissions BS EN/EN 55011 (CISPR 11), Class B; the family feature states Class B without additional components. Harmonic current BS EN/EN 61000-3-2, Class A. Voltage flicker BS EN/EN 61000-3-3 is listed; no separate class or level is stated. Immunity standards BS EN/EN 55035 and BS EN/EN 60601-1-2. Immunity test entries: BS EN/EN 61000-4-2, ESD Level 4, 15 kV air and 8 kV contact; 61000-4-3, RF Level 3, 10 V/m from 80 MHz to 2.7 GHz, plus Table 9 fields of 9–28 V/m from 385 MHz to 5.78 GHz; 61000-4-4, EFT Level 3, 2 kV; 61000-4-5, surge Level 3, 1 kV line-to-line; 61000-4-6, conducted Level 3, 10 V; and 61000-4-8, magnetic field Level 4, 30 A/m. The BS EN/EN 61000-4-11 entries are greater than 95% dip for 0.5 periods, 30% dip for 25 periods, and greater than 95% interruption for 250 periods. These component test entries do not replace final-equipment EMC verification. Dimensions, terminals and installation Overall dimensions, L × W × H 109 × 52 × 33.5 mm Catalogue case / general tolerance IRM60 / ±1 mm unless otherwise marked. Connection method Screw terminals marked AC/N, AC/L, −Vo and +Vo. Vibration 10–500 Hz, 5 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. The top-view drawing on PDF page 28 labels the input terminals AC/N then AC/L from left to right. The output bank is −Vo, −Vo, +Vo, +Vo from left to right. Input terminal pitch is 7.5 mm and output pitch is 5 mm. Four 3.5 mm diameter mounting holes form the dimensioned 33 × 98 mm pattern. Overall height is 33.5 mm; the separate 6.7 mm side-view dimension is a drawing reference, not an additional overall height. Use the model-specific installation drawing and the manufacturer installation instructions referenced in the PDF. The catalogue does not specify a separate mating-connector, bracket or wiring-kit order code for this version; it also does not give terminal torque or wire-gauge values. Select installation hardware for the actual mounting and electrical conditions. Reference mass and reliability Catalogue packing reference per unit 216 g, from the explicit unit value in the PACKING entry on PDF page 26. This is not a measured net weight or shipping-package weight. MTBF, catalogue minimum estimates 5087.8 thousand hours, Telcordia SR-332 (Bellcore); 563.4 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer datasheet warranty 3 years.

  • MPM-65-48

    MEAN WELL MPM-65 series: PCB-mount medical AC/DC power module - MPM-65-48

    MEAN WELL MPM-65-48 is a PCB-mount medical AC/DC power module delivering 48 V DC at 1.36 A (65.3 W) by convection, with a conditional 1.49 A / 71.5 W peak rating for up to 10 seconds. It accepts 80–264 V AC or 113–370 V DC and provides Class II insulation with 2 × MOPP; BF application suitability depends on the completed system. Product Datasheet Download MEAN WELL MPM-65 Datasheet (PDF) The MPM-65 section is on PDF pages 25, 26, 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and mounting Complete model MPM-65-48 Product type Isolated AC/DC medical power module, single 48 V DC output Mounting configuration No suffix: PCB mounting version. Model code MPM identifies the series; 65 identifies the family; 48 identifies nominal output voltage. Use the actual continuous and peak ratings below. Output and peak load Nominal DC output 48 V Continuous convection rating 1.36 A; 65.3 W Peak rating 1.49 A; 71.5 W, for up to 10 seconds under the duty and average-power limits. Ripple and noise, maximum 240 mV peak-to-peak Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±0.5% Minimum load No minimum load required. Peak operation is limited to a maximum 33% duty cycle within every 30-second interval, and average output power must not exceed the continuous rated power. The peak duration, duty cycle, average power and thermal/input derating conditions all apply together. Ripple and noise are measured with a 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Unless separately stated, catalogue parameters use 230 V AC input, rated load and 25°C ambient. Input, efficiency and timing Input range 80–264 V AC or 113–370 V DC; output derating applies at low input. AC frequency 47–63 Hz Typical efficiency 92% at the catalogue reference conditions. Typical AC current 1.5 A at 115 V AC; 1 A at 230 V AC. Typical cold-start inrush 30 A at 115 V AC; 65 A at 230 V AC. Set-up / rise time 1000 ms / 30 ms at 230 V AC or 115 V AC, full load. Typical hold-up time 50 ms at 230 V AC; 12 ms at 115 V AC, full load. No-load input power Less than 0.1 W. The 60 Hz input-voltage curve on PDF page 27 permits 80% load at 80 V AC, rising to 100% at 100 V AC and remaining at 100% through 264 V AC. Apply this together with the ambient-temperature curve. The block diagram identifies a 70 kHz switching frequency. Protection Short circuit / overload Overload threshold: 115–135% of rated output power. Hiccup protection recovers automatically after the fault is removed. Overvoltage 50.4–64.8 V; output shuts down. Re-power the unit to recover. Overtemperature Output shuts down; re-power the unit to recover. Temperature, cooling and altitude Working ambient range -30 to +80°C, subject to the applicable load derating curve. Storage temperature -40 to +85°C. Working humidity 20–90% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Maximum operating altitude / overvoltage category 4000 m / OVC II. For this 48 V version, the horizontal-mounting curve allows 100% load from -30°C to 55°C, then requires derating: 80% at 60°C, 50% at 70°C and 30% at 80°C. Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this convection-cooled module. A generic 5°C/1000 m note for fan-equipped models does not identify a fan in this version. The upper ambient limit is not a full-load rating. Medical isolation and integration Insulation class Class II, double insulation; no functional-ground terminal. Primary-to-secondary protection 2 × MOPP (means of patient protection). Input-to-output withstand voltage 4 kV AC. Input-to-output insulation resistance 100 MΩ at 500 V DC, 25°C and 70% RH. Maximum touch current Less than 100 µA at 264 V AC, measured from primary input to DC output. Suitable for BF (body-floating, patient-contact) applications only with appropriate system consideration. The module is a component, so the completed medical equipment and its applied-part isolation must be assessed as a system. The specification lists IEC 60601-1:2005+A1; TUV BS EN/EN 60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; and EAC TP TC 004 approvals. Design reference to BS EN/EN 60335-1 is by request and is not a blanket approval for every delivered unit. Catalogue application examples include portable medical devices, mobile clinical workstations, medical computer monitors and medical examination instruments. EMC Conducted and radiated emissions BS EN/EN 55011 (CISPR 11), Class B; the family feature states Class B without additional components. Harmonic current BS EN/EN 61000-3-2, Class A. Voltage flicker BS EN/EN 61000-3-3 is listed; no separate class or level is stated. Immunity standards BS EN/EN 55035 and BS EN/EN 60601-1-2. Immunity test entries: BS EN/EN 61000-4-2, ESD Level 4, 15 kV air and 8 kV contact; 61000-4-3, RF Level 3, 10 V/m from 80 MHz to 2.7 GHz, plus Table 9 fields of 9–28 V/m from 385 MHz to 5.78 GHz; 61000-4-4, EFT Level 3, 2 kV; 61000-4-5, surge Level 3, 1 kV line-to-line; 61000-4-6, conducted Level 3, 10 V; and 61000-4-8, magnetic field Level 4, 30 A/m. The BS EN/EN 61000-4-11 entries are greater than 95% dip for 0.5 periods, 30% dip for 25 periods, and greater than 95% interruption for 250 periods. These component test entries do not replace final-equipment EMC verification. Dimensions, terminals and installation Overall dimensions, L × W × H 87 × 52 × 29.5 mm Catalogue case / general tolerance IRM60 / ±1 mm unless otherwise marked. Connection method PCB pins marked AC/N, AC/L, −Vo and +Vo; bottom-view footprint. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Use the bottom-view PCB footprint on PDF page 28: AC/N and AC/L are the two input pins on the right of that drawing; −Vo and +Vo are the two output pins on the left. AC pins are 1 mm diameter and DC pins are 2 mm diameter, with 3.5 ±1 mm projection. The pin-column spacing is 76 mm, input-pin spacing 6.75 mm and output-pin spacing 5.5 mm. The drawing also gives 5.7, 5 and 40.75 mm coordinate references; use the complete footprint rather than a mirrored top view. PCB soldering limits: wave soldering 265°C for 5 seconds maximum; manual soldering 390°C for 3 seconds maximum. Use the model-specific installation drawing and the manufacturer installation instructions referenced in the PDF. The catalogue does not specify a separate mating-connector, bracket or wiring-kit order code for this version; it also does not give terminal torque or wire-gauge values. Select installation hardware for the actual mounting and electrical conditions. Reference mass and reliability Catalogue packing reference per unit 191 g, from the explicit unit value in the PACKING entry on PDF page 26. This is not a measured net weight or shipping-package weight. MTBF, catalogue minimum estimates 5087.8 thousand hours, Telcordia SR-332 (Bellcore); 563.4 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer datasheet warranty 3 years.

  • MPM-65-24

    MEAN WELL MPM-65 series: PCB-mount medical AC/DC power module - MPM-65-24

    MEAN WELL MPM-65-24 is a PCB-mount medical AC/DC power module delivering 24 V DC at 2.71 A (65 W) by convection, with a conditional 2.98 A / 71.5 W peak rating for up to 10 seconds. It accepts 80–264 V AC or 113–370 V DC and provides Class II insulation with 2 × MOPP; BF application suitability depends on the completed system. Product Datasheet Download MEAN WELL MPM-65 Datasheet (PDF) The MPM-65 section is on PDF pages 25, 26, 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and mounting Complete model MPM-65-24 Product type Isolated AC/DC medical power module, single 24 V DC output Mounting configuration No suffix: PCB mounting version. Model code MPM identifies the series; 65 identifies the family; 24 identifies nominal output voltage. Use the actual continuous and peak ratings below. Output and peak load Nominal DC output 24 V Continuous convection rating 2.71 A; 65 W Peak rating 2.98 A; 71.5 W, for up to 10 seconds under the duty and average-power limits. Ripple and noise, maximum 200 mV peak-to-peak Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±0.5% Minimum load No minimum load required. Peak operation is limited to a maximum 33% duty cycle within every 30-second interval, and average output power must not exceed the continuous rated power. The peak duration, duty cycle, average power and thermal/input derating conditions all apply together. Ripple and noise are measured with a 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Unless separately stated, catalogue parameters use 230 V AC input, rated load and 25°C ambient. Input, efficiency and timing Input range 80–264 V AC or 113–370 V DC; output derating applies at low input. AC frequency 47–63 Hz Typical efficiency 93% at the catalogue reference conditions. Typical AC current 1.5 A at 115 V AC; 1 A at 230 V AC. Typical cold-start inrush 30 A at 115 V AC; 65 A at 230 V AC. Set-up / rise time 1000 ms / 30 ms at 230 V AC or 115 V AC, full load. Typical hold-up time 50 ms at 230 V AC; 12 ms at 115 V AC, full load. No-load input power Less than 0.1 W. The 60 Hz input-voltage curve on PDF page 27 permits 80% load at 80 V AC, rising to 100% at 100 V AC and remaining at 100% through 264 V AC. Apply this together with the ambient-temperature curve. The block diagram identifies a 70 kHz switching frequency. Protection Short circuit / overload Overload threshold: 115–135% of rated output power. Hiccup protection recovers automatically after the fault is removed. Overvoltage 25.2–32.4 V; output shuts down. Re-power the unit to recover. Overtemperature Output shuts down; re-power the unit to recover. Temperature, cooling and altitude Working ambient range -30 to +80°C, subject to the applicable load derating curve. Storage temperature -40 to +85°C. Working humidity 20–90% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Maximum operating altitude / overvoltage category 4000 m / OVC II. For this 24 V version, the horizontal-mounting curve allows 100% load from -30°C to 55°C, then requires derating: 80% at 60°C, 50% at 70°C and 30% at 80°C. Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this convection-cooled module. A generic 5°C/1000 m note for fan-equipped models does not identify a fan in this version. The upper ambient limit is not a full-load rating. Medical isolation and integration Insulation class Class II, double insulation; no functional-ground terminal. Primary-to-secondary protection 2 × MOPP (means of patient protection). Input-to-output withstand voltage 4 kV AC. Input-to-output insulation resistance 100 MΩ at 500 V DC, 25°C and 70% RH. Maximum touch current Less than 100 µA at 264 V AC, measured from primary input to DC output. Suitable for BF (body-floating, patient-contact) applications only with appropriate system consideration. The module is a component, so the completed medical equipment and its applied-part isolation must be assessed as a system. The specification lists IEC 60601-1:2005+A1; TUV BS EN/EN 60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; and EAC TP TC 004 approvals. Design reference to BS EN/EN 60335-1 is by request and is not a blanket approval for every delivered unit. Catalogue application examples include portable medical devices, mobile clinical workstations, medical computer monitors and medical examination instruments. EMC Conducted and radiated emissions BS EN/EN 55011 (CISPR 11), Class B; the family feature states Class B without additional components. Harmonic current BS EN/EN 61000-3-2, Class A. Voltage flicker BS EN/EN 61000-3-3 is listed; no separate class or level is stated. Immunity standards BS EN/EN 55035 and BS EN/EN 60601-1-2. Immunity test entries: BS EN/EN 61000-4-2, ESD Level 4, 15 kV air and 8 kV contact; 61000-4-3, RF Level 3, 10 V/m from 80 MHz to 2.7 GHz, plus Table 9 fields of 9–28 V/m from 385 MHz to 5.78 GHz; 61000-4-4, EFT Level 3, 2 kV; 61000-4-5, surge Level 3, 1 kV line-to-line; 61000-4-6, conducted Level 3, 10 V; and 61000-4-8, magnetic field Level 4, 30 A/m. The BS EN/EN 61000-4-11 entries are greater than 95% dip for 0.5 periods, 30% dip for 25 periods, and greater than 95% interruption for 250 periods. These component test entries do not replace final-equipment EMC verification. Dimensions, terminals and installation Overall dimensions, L × W × H 87 × 52 × 29.5 mm Catalogue case / general tolerance IRM60 / ±1 mm unless otherwise marked. Connection method PCB pins marked AC/N, AC/L, −Vo and +Vo; bottom-view footprint. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Use the bottom-view PCB footprint on PDF page 28: AC/N and AC/L are the two input pins on the right of that drawing; −Vo and +Vo are the two output pins on the left. AC pins are 1 mm diameter and DC pins are 2 mm diameter, with 3.5 ±1 mm projection. The pin-column spacing is 76 mm, input-pin spacing 6.75 mm and output-pin spacing 5.5 mm. The drawing also gives 5.7, 5 and 40.75 mm coordinate references; use the complete footprint rather than a mirrored top view. PCB soldering limits: wave soldering 265°C for 5 seconds maximum; manual soldering 390°C for 3 seconds maximum. Use the model-specific installation drawing and the manufacturer installation instructions referenced in the PDF. The catalogue does not specify a separate mating-connector, bracket or wiring-kit order code for this version; it also does not give terminal torque or wire-gauge values. Select installation hardware for the actual mounting and electrical conditions. Reference mass and reliability Catalogue packing reference per unit 191 g, from the explicit unit value in the PACKING entry on PDF page 26. This is not a measured net weight or shipping-package weight. MTBF, catalogue minimum estimates 5087.8 thousand hours, Telcordia SR-332 (Bellcore); 563.4 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer datasheet warranty 3 years.

  • MPM-65-15

    MEAN WELL MPM-65 series: PCB-mount medical AC/DC power module - MPM-65-15

    MEAN WELL MPM-65-15 is a PCB-mount medical AC/DC power module delivering 15 V DC at 4.33 A (65 W) by convection, with a conditional 4.77 A / 71.6 W peak rating for up to 10 seconds. It accepts 80–264 V AC or 113–370 V DC and provides Class II insulation with 2 × MOPP; BF application suitability depends on the completed system. Product Datasheet Download MEAN WELL MPM-65 Datasheet (PDF) The MPM-65 section is on PDF pages 25, 26, 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and mounting Complete model MPM-65-15 Product type Isolated AC/DC medical power module, single 15 V DC output Mounting configuration No suffix: PCB mounting version. Model code MPM identifies the series; 65 identifies the family; 15 identifies nominal output voltage. Use the actual continuous and peak ratings below. Output and peak load Nominal DC output 15 V Continuous convection rating 4.33 A; 65 W Peak rating 4.77 A; 71.6 W, for up to 10 seconds under the duty and average-power limits. Ripple and noise, maximum 120 mV peak-to-peak Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±0.5% Minimum load No minimum load required. Peak operation is limited to a maximum 33% duty cycle within every 30-second interval, and average output power must not exceed the continuous rated power. The peak duration, duty cycle, average power and thermal/input derating conditions all apply together. Ripple and noise are measured with a 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Unless separately stated, catalogue parameters use 230 V AC input, rated load and 25°C ambient. Input, efficiency and timing Input range 80–264 V AC or 113–370 V DC; output derating applies at low input. AC frequency 47–63 Hz Typical efficiency 92.5% at the catalogue reference conditions. Typical AC current 1.5 A at 115 V AC; 1 A at 230 V AC. Typical cold-start inrush 30 A at 115 V AC; 65 A at 230 V AC. Set-up / rise time 1000 ms / 30 ms at 230 V AC or 115 V AC, full load. Typical hold-up time 50 ms at 230 V AC; 12 ms at 115 V AC, full load. No-load input power Less than 0.1 W. The 60 Hz input-voltage curve on PDF page 27 permits 80% load at 80 V AC, rising to 100% at 100 V AC and remaining at 100% through 264 V AC. Apply this together with the ambient-temperature curve. The block diagram identifies a 70 kHz switching frequency. Protection Short circuit / overload Overload threshold: 115–135% of rated output power. Hiccup protection recovers automatically after the fault is removed. Overvoltage 15.8–20.3 V; output shuts down. Re-power the unit to recover. Overtemperature Output shuts down; re-power the unit to recover. Temperature, cooling and altitude Working ambient range -30 to +80°C, subject to the applicable load derating curve. Storage temperature -40 to +85°C. Working humidity 20–90% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Maximum operating altitude / overvoltage category 4000 m / OVC II. For this 15 V version, the horizontal-mounting curve allows 100% load from -30°C to 50°C, then requires derating: 80% at 60°C, 50% at 70°C and 30% at 80°C. Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this convection-cooled module. A generic 5°C/1000 m note for fan-equipped models does not identify a fan in this version. The upper ambient limit is not a full-load rating. Medical isolation and integration Insulation class Class II, double insulation; no functional-ground terminal. Primary-to-secondary protection 2 × MOPP (means of patient protection). Input-to-output withstand voltage 4 kV AC. Input-to-output insulation resistance 100 MΩ at 500 V DC, 25°C and 70% RH. Maximum touch current Less than 100 µA at 264 V AC, measured from primary input to DC output. Suitable for BF (body-floating, patient-contact) applications only with appropriate system consideration. The module is a component, so the completed medical equipment and its applied-part isolation must be assessed as a system. The specification lists IEC 60601-1:2005+A1; TUV BS EN/EN 60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; and EAC TP TC 004 approvals. Design reference to BS EN/EN 60335-1 is by request and is not a blanket approval for every delivered unit. Catalogue application examples include portable medical devices, mobile clinical workstations, medical computer monitors and medical examination instruments. EMC Conducted and radiated emissions BS EN/EN 55011 (CISPR 11), Class B; the family feature states Class B without additional components. Harmonic current BS EN/EN 61000-3-2, Class A. Voltage flicker BS EN/EN 61000-3-3 is listed; no separate class or level is stated. Immunity standards BS EN/EN 55035 and BS EN/EN 60601-1-2. Immunity test entries: BS EN/EN 61000-4-2, ESD Level 4, 15 kV air and 8 kV contact; 61000-4-3, RF Level 3, 10 V/m from 80 MHz to 2.7 GHz, plus Table 9 fields of 9–28 V/m from 385 MHz to 5.78 GHz; 61000-4-4, EFT Level 3, 2 kV; 61000-4-5, surge Level 3, 1 kV line-to-line; 61000-4-6, conducted Level 3, 10 V; and 61000-4-8, magnetic field Level 4, 30 A/m. The BS EN/EN 61000-4-11 entries are greater than 95% dip for 0.5 periods, 30% dip for 25 periods, and greater than 95% interruption for 250 periods. These component test entries do not replace final-equipment EMC verification. Dimensions, terminals and installation Overall dimensions, L × W × H 87 × 52 × 29.5 mm Catalogue case / general tolerance IRM60 / ±1 mm unless otherwise marked. Connection method PCB pins marked AC/N, AC/L, −Vo and +Vo; bottom-view footprint. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Use the bottom-view PCB footprint on PDF page 28: AC/N and AC/L are the two input pins on the right of that drawing; −Vo and +Vo are the two output pins on the left. AC pins are 1 mm diameter and DC pins are 2 mm diameter, with 3.5 ±1 mm projection. The pin-column spacing is 76 mm, input-pin spacing 6.75 mm and output-pin spacing 5.5 mm. The drawing also gives 5.7, 5 and 40.75 mm coordinate references; use the complete footprint rather than a mirrored top view. PCB soldering limits: wave soldering 265°C for 5 seconds maximum; manual soldering 390°C for 3 seconds maximum. Use the model-specific installation drawing and the manufacturer installation instructions referenced in the PDF. The catalogue does not specify a separate mating-connector, bracket or wiring-kit order code for this version; it also does not give terminal torque or wire-gauge values. Select installation hardware for the actual mounting and electrical conditions. Reference mass and reliability Catalogue packing reference per unit 191 g, from the explicit unit value in the PACKING entry on PDF page 26. This is not a measured net weight or shipping-package weight. MTBF, catalogue minimum estimates 5087.8 thousand hours, Telcordia SR-332 (Bellcore); 563.4 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer datasheet warranty 3 years.

  • MPM-65-12

    MEAN WELL MPM-65 series: PCB-mount medical AC/DC power module - MPM-65-12

    MEAN WELL MPM-65-12 is a PCB-mount medical AC/DC power module delivering 12 V DC at 5.42 A (65 W) by convection, with a conditional 5.96 A / 71.5 W peak rating for up to 10 seconds. It accepts 80–264 V AC or 113–370 V DC and provides Class II insulation with 2 × MOPP; BF application suitability depends on the completed system. Product Datasheet Download MEAN WELL MPM-65 Datasheet (PDF) The MPM-65 section is on PDF pages 25, 26, 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and mounting Complete model MPM-65-12 Product type Isolated AC/DC medical power module, single 12 V DC output Mounting configuration No suffix: PCB mounting version. Model code MPM identifies the series; 65 identifies the family; 12 identifies nominal output voltage. Use the actual continuous and peak ratings below. Output and peak load Nominal DC output 12 V Continuous convection rating 5.42 A; 65 W Peak rating 5.96 A; 71.5 W, for up to 10 seconds under the duty and average-power limits. Ripple and noise, maximum 120 mV peak-to-peak Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±1.0% Minimum load No minimum load required. Peak operation is limited to a maximum 33% duty cycle within every 30-second interval, and average output power must not exceed the continuous rated power. The peak duration, duty cycle, average power and thermal/input derating conditions all apply together. Ripple and noise are measured with a 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Unless separately stated, catalogue parameters use 230 V AC input, rated load and 25°C ambient. Input, efficiency and timing Input range 80–264 V AC or 113–370 V DC; output derating applies at low input. AC frequency 47–63 Hz Typical efficiency 92.5% at the catalogue reference conditions. Typical AC current 1.5 A at 115 V AC; 1 A at 230 V AC. Typical cold-start inrush 30 A at 115 V AC; 65 A at 230 V AC. Set-up / rise time 1000 ms / 30 ms at 230 V AC or 115 V AC, full load. Typical hold-up time 50 ms at 230 V AC; 12 ms at 115 V AC, full load. No-load input power Less than 0.1 W. The 60 Hz input-voltage curve on PDF page 27 permits 80% load at 80 V AC, rising to 100% at 100 V AC and remaining at 100% through 264 V AC. Apply this together with the ambient-temperature curve. The block diagram identifies a 70 kHz switching frequency. Protection Short circuit / overload Overload threshold: 115–135% of rated output power. Hiccup protection recovers automatically after the fault is removed. Overvoltage 12.6–16.2 V; output shuts down. Re-power the unit to recover. Overtemperature Output shuts down; re-power the unit to recover. Temperature, cooling and altitude Working ambient range -30 to +80°C, subject to the applicable load derating curve. Storage temperature -40 to +85°C. Working humidity 20–90% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Maximum operating altitude / overvoltage category 4000 m / OVC II. For this 12 V version, the horizontal-mounting curve allows 100% load from -30°C to 50°C, then requires derating: 80% at 60°C, 50% at 70°C and 30% at 80°C. Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this convection-cooled module. A generic 5°C/1000 m note for fan-equipped models does not identify a fan in this version. The upper ambient limit is not a full-load rating. Medical isolation and integration Insulation class Class II, double insulation; no functional-ground terminal. Primary-to-secondary protection 2 × MOPP (means of patient protection). Input-to-output withstand voltage 4 kV AC. Input-to-output insulation resistance 100 MΩ at 500 V DC, 25°C and 70% RH. Maximum touch current Less than 100 µA at 264 V AC, measured from primary input to DC output. Suitable for BF (body-floating, patient-contact) applications only with appropriate system consideration. The module is a component, so the completed medical equipment and its applied-part isolation must be assessed as a system. The specification lists IEC 60601-1:2005+A1; TUV BS EN/EN 60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; and EAC TP TC 004 approvals. Design reference to BS EN/EN 60335-1 is by request and is not a blanket approval for every delivered unit. Catalogue application examples include portable medical devices, mobile clinical workstations, medical computer monitors and medical examination instruments. EMC Conducted and radiated emissions BS EN/EN 55011 (CISPR 11), Class B; the family feature states Class B without additional components. Harmonic current BS EN/EN 61000-3-2, Class A. Voltage flicker BS EN/EN 61000-3-3 is listed; no separate class or level is stated. Immunity standards BS EN/EN 55035 and BS EN/EN 60601-1-2. Immunity test entries: BS EN/EN 61000-4-2, ESD Level 4, 15 kV air and 8 kV contact; 61000-4-3, RF Level 3, 10 V/m from 80 MHz to 2.7 GHz, plus Table 9 fields of 9–28 V/m from 385 MHz to 5.78 GHz; 61000-4-4, EFT Level 3, 2 kV; 61000-4-5, surge Level 3, 1 kV line-to-line; 61000-4-6, conducted Level 3, 10 V; and 61000-4-8, magnetic field Level 4, 30 A/m. The BS EN/EN 61000-4-11 entries are greater than 95% dip for 0.5 periods, 30% dip for 25 periods, and greater than 95% interruption for 250 periods. These component test entries do not replace final-equipment EMC verification. Dimensions, terminals and installation Overall dimensions, L × W × H 87 × 52 × 29.5 mm Catalogue case / general tolerance IRM60 / ±1 mm unless otherwise marked. Connection method PCB pins marked AC/N, AC/L, −Vo and +Vo; bottom-view footprint. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Use the bottom-view PCB footprint on PDF page 28: AC/N and AC/L are the two input pins on the right of that drawing; −Vo and +Vo are the two output pins on the left. AC pins are 1 mm diameter and DC pins are 2 mm diameter, with 3.5 ±1 mm projection. The pin-column spacing is 76 mm, input-pin spacing 6.75 mm and output-pin spacing 5.5 mm. The drawing also gives 5.7, 5 and 40.75 mm coordinate references; use the complete footprint rather than a mirrored top view. PCB soldering limits: wave soldering 265°C for 5 seconds maximum; manual soldering 390°C for 3 seconds maximum. Use the model-specific installation drawing and the manufacturer installation instructions referenced in the PDF. The catalogue does not specify a separate mating-connector, bracket or wiring-kit order code for this version; it also does not give terminal torque or wire-gauge values. Select installation hardware for the actual mounting and electrical conditions. Reference mass and reliability Catalogue packing reference per unit 191 g, from the explicit unit value in the PACKING entry on PDF page 26. This is not a measured net weight or shipping-package weight. MTBF, catalogue minimum estimates 5087.8 thousand hours, Telcordia SR-332 (Bellcore); 563.4 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer datasheet warranty 3 years.

  • MPM-65-5

    MEAN WELL MPM-65 series: PCB-mount medical AC/DC power module - MPM-65-5

    MEAN WELL MPM-65-5 is a PCB-mount medical AC/DC power module delivering 5 V DC at 10 A (50 W) by convection, with a conditional 11 A / 55 W peak rating for up to 10 seconds. It accepts 80–264 V AC or 113–370 V DC and provides Class II insulation with 2 × MOPP; BF application suitability depends on the completed system. Product Datasheet Download MEAN WELL MPM-65 Datasheet (PDF) The MPM-65 section is on PDF pages 25, 26, 27, 28. Refer to the complete mechanical drawings and notes when planning installation. Model and mounting Complete model MPM-65-5 Product type Isolated AC/DC medical power module, single 5 V DC output Mounting configuration No suffix: PCB mounting version. Model code MPM identifies the series; 65 identifies the family; 5 identifies nominal output voltage. Use the actual continuous and peak ratings below. Output and peak load Nominal DC output 5 V Continuous convection rating 10 A; 50 W Peak rating 11 A; 55 W, for up to 10 seconds under the duty and average-power limits. Ripple and noise, maximum 80 mV peak-to-peak Voltage tolerance ±2.0%, including set-up tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±1.0% Minimum load No minimum load required. Peak operation is limited to a maximum 33% duty cycle within every 30-second interval, and average output power must not exceed the continuous rated power. The peak duration, duty cycle, average power and thermal/input derating conditions all apply together. Ripple and noise are measured with a 20 MHz bandwidth using a 12-inch twisted pair terminated with 0.1 µF and 47 µF capacitors in parallel. Unless separately stated, catalogue parameters use 230 V AC input, rated load and 25°C ambient. Input, efficiency and timing Input range 80–264 V AC or 113–370 V DC; output derating applies at low input. AC frequency 47–63 Hz Typical efficiency 86.5% at the catalogue reference conditions. Typical AC current 1.5 A at 115 V AC; 1 A at 230 V AC. Typical cold-start inrush 30 A at 115 V AC; 65 A at 230 V AC. Set-up / rise time 1000 ms / 30 ms at 230 V AC or 115 V AC, full load. Typical hold-up time 50 ms at 230 V AC; 12 ms at 115 V AC, full load. No-load input power Less than 0.1 W. The 60 Hz input-voltage curve on PDF page 27 permits 80% load at 80 V AC, rising to 100% at 100 V AC and remaining at 100% through 264 V AC. Apply this together with the ambient-temperature curve. The block diagram identifies a 70 kHz switching frequency. Protection Short circuit / overload Overload threshold: 115–135% of rated output power. Hiccup protection recovers automatically after the fault is removed. Overvoltage 5.3–7.2 V; output shuts down. Re-power the unit to recover. Overtemperature Output shuts down; re-power the unit to recover. Temperature, cooling and altitude Working ambient range -30 to +80°C, subject to the applicable load derating curve. Storage temperature -40 to +85°C. Working humidity 20–90% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Maximum operating altitude / overvoltage category 4000 m / OVC II. For this 5 V version, the horizontal-mounting curve allows 100% load from -30°C to 50°C, then requires derating: 80% at 60°C, 50% at 70°C and 30% at 80°C. Above 2000 m, reduce the allowable ambient temperature by 3.5°C per additional 1000 m for this convection-cooled module. A generic 5°C/1000 m note for fan-equipped models does not identify a fan in this version. The upper ambient limit is not a full-load rating. Medical isolation and integration Insulation class Class II, double insulation; no functional-ground terminal. Primary-to-secondary protection 2 × MOPP (means of patient protection). Input-to-output withstand voltage 4 kV AC. Input-to-output insulation resistance 100 MΩ at 500 V DC, 25°C and 70% RH. Maximum touch current Less than 100 µA at 264 V AC, measured from primary input to DC output. Suitable for BF (body-floating, patient-contact) applications only with appropriate system consideration. The module is a component, so the completed medical equipment and its applied-part isolation must be assessed as a system. The specification lists IEC 60601-1:2005+A1; TUV BS EN/EN 60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; and EAC TP TC 004 approvals. Design reference to BS EN/EN 60335-1 is by request and is not a blanket approval for every delivered unit. Catalogue application examples include portable medical devices, mobile clinical workstations, medical computer monitors and medical examination instruments. EMC Conducted and radiated emissions BS EN/EN 55011 (CISPR 11), Class B; the family feature states Class B without additional components. Harmonic current BS EN/EN 61000-3-2, Class A. Voltage flicker BS EN/EN 61000-3-3 is listed; no separate class or level is stated. Immunity standards BS EN/EN 55035 and BS EN/EN 60601-1-2. Immunity test entries: BS EN/EN 61000-4-2, ESD Level 4, 15 kV air and 8 kV contact; 61000-4-3, RF Level 3, 10 V/m from 80 MHz to 2.7 GHz, plus Table 9 fields of 9–28 V/m from 385 MHz to 5.78 GHz; 61000-4-4, EFT Level 3, 2 kV; 61000-4-5, surge Level 3, 1 kV line-to-line; 61000-4-6, conducted Level 3, 10 V; and 61000-4-8, magnetic field Level 4, 30 A/m. The BS EN/EN 61000-4-11 entries are greater than 95% dip for 0.5 periods, 30% dip for 25 periods, and greater than 95% interruption for 250 periods. These component test entries do not replace final-equipment EMC verification. Dimensions, terminals and installation Overall dimensions, L × W × H 87 × 52 × 29.5 mm Catalogue case / general tolerance IRM60 / ±1 mm unless otherwise marked. Connection method PCB pins marked AC/N, AC/L, −Vo and +Vo; bottom-view footprint. Vibration 10–500 Hz, 2 G; 10 minutes per cycle, 60 minutes along each X, Y and Z axis. Use the bottom-view PCB footprint on PDF page 28: AC/N and AC/L are the two input pins on the right of that drawing; −Vo and +Vo are the two output pins on the left. AC pins are 1 mm diameter and DC pins are 2 mm diameter, with 3.5 ±1 mm projection. The pin-column spacing is 76 mm, input-pin spacing 6.75 mm and output-pin spacing 5.5 mm. The drawing also gives 5.7, 5 and 40.75 mm coordinate references; use the complete footprint rather than a mirrored top view. PCB soldering limits: wave soldering 265°C for 5 seconds maximum; manual soldering 390°C for 3 seconds maximum. Use the model-specific installation drawing and the manufacturer installation instructions referenced in the PDF. The catalogue does not specify a separate mating-connector, bracket or wiring-kit order code for this version; it also does not give terminal torque or wire-gauge values. Select installation hardware for the actual mounting and electrical conditions. Reference mass and reliability Catalogue packing reference per unit 191 g, from the explicit unit value in the PACKING entry on PDF page 26. This is not a measured net weight or shipping-package weight. MTBF, catalogue minimum estimates 5087.8 thousand hours, Telcordia SR-332 (Bellcore); 563.4 thousand hours, MIL-HDBK-217F at 25°C. Manufacturer datasheet warranty 3 years.

  • MPM-45-48ST

    MEAN WELL MPM-45 series: Screw Terminal Medical AC/DC Power Supply - MPM-45-48ST

    MEAN WELL MPM-45-48ST is a screw terminal medical AC/DC power supply with 48 V output, 0.94 A rated current and 45.1 W catalogue-rated output power. It uses Class II construction without FG and provides 2 MOPP primary-secondary isolation. BF applications require appropriate system consideration; apply the model-specific peak, thermal and input-voltage limits. Product Datasheet Download MEAN WELL MPM-45 Datasheet (PDF) The MPM-45 section is on PDF pages 21, 22, 23, 24. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Selection Complete model MPM-45-48ST Series MPM-45 medical AC/DC power supply. Output code 48 V nominal DC output. Mounting suffix ST: screw terminal style. This version uses the specified mounting style and has the model-specific vibration rating stated below. Typical applications include portable medical devices, mobile clinical workstations, medical computer monitors and medical examination instruments. DC Output and Peak Operation Nominal DC voltage 48 V. Rated current 0.94 A. Rated cooling condition Natural convection; no minimum load required. Catalogue-rated output power 45.1 W. Peak current and power 1.05 A and 50.4 W for up to 10 seconds; subject to the duty and average-power limits below. Ripple and noise, maximum 240 mVp-p. Voltage tolerance ±2.0%; includes setup tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±0.5%. Peak operation is limited to a maximum 33% duty cycle within every 30 seconds. Average output power must not exceed the rated power. The peak rating is not a continuous-output allowance; observe the specified current and power limits together. Ripple and noise are measured at 20 MHz bandwidth with a 12-inch twisted-pair wire terminated by 0.1 µF and 47 µF capacitors in parallel. Use the catalogue-rated power, current and voltage as separate selection limits. Input and Timing Input voltage 80–264 V AC or 113–370 V DC. AC frequency 47–63 Hz. Efficiency, typical 92% at the default specified test conditions. AC current, typical 1.2 A at 115 V AC; 0.6 A at 230 V AC. Cold-start inrush, typical 30 A at 115 V AC; 60 A at 230 V AC. Setup / rise time 1000 ms / 30 ms at both 230 V AC and 115 V AC, full load. Hold-up time, typical 50 ms at 230 V AC; 12 ms at 115 V AC, full load. No-load consumption Less than 0.1 W. Protection and Medical Isolation Short circuit Short-circuit protection is listed. Overload 115–135% of rated output power; hiccup mode, automatic recovery after the fault is removed. Overvoltage 50.4–64.8 V; output shutdown, re-power to recover. Overtemperature Output shutdown, re-power to recover. Touch current Less than 100 µA at 264 V AC, measured from primary to DC output. Primary-secondary isolation 2 × MOPP. Construction Class II, without FG. Withstand voltage Input to output: 4 kV AC. Isolation resistance Input to output: 100 MΩ at 500 V DC, 25°C and 70% RH. Suitable for BF applications only with appropriate system consideration. These component ratings do not certify an assembled medical device or permit ignoring the final equipment insulation and leakage-current requirements. Cooling and Operating Limits Operating ambient −30 to +80°C; subject to the derating curve. Temperature derating Horizontal mounting, this output-voltage version: 100% load from −30 to +60°C, then along the plotted segments to 75% at +70°C and 40% at +80°C. Input-voltage derating The 60 Hz AC-input curve gives 80% load at 80 V AC, rising to 100% at 100 V AC and remaining at 100% to 264 V AC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C. Temperature coefficient ±0.03%/°C over 0–60°C. Operating altitude Up to 4000 m / overvoltage category II. Altitude derating For fanless operation above 2000 m (6500 ft), reduce permissible ambient temperature by 3.5°C per additional 1000 m. Vibration 5 G, 10–500 Hz, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Apply the temperature, input-voltage and altitude limits together. Maximum ambient temperature does not imply full rated output at that temperature. Peak operation must also stay within the average-power and duty-cycle limits. Dimensions, Connections and Installation Dimensions (L × W × H) 109 × 52 × 33.5 mm. Case reference IRM60. Drawing tolerance ±1 mm. Screw terminals Top view: input AC/N and AC/L at one end; output −Vo, −Vo, +Vo, +Vo at the opposite end. The repeated output terminals share the single output; they do not add current capacity. Mounting holes Four Ø3.5 mm holes; the drawing marks 98 × 33 mm between the mounting-hole positions. Terminal drawing dimensions Input-terminal pitch 7.5 mm; output-terminal pitches 5 mm. Follow the full mechanical drawing for clearance. Use the mechanical drawing for this mounting version and the manufacturer installation instructions. PCB and screw-terminal styles have different dimensions, connection layouts and vibration ratings; they are not interchangeable mounting patterns. The reviewed pages do not specify a separate accessory ordering code, mating connector, DIN-rail adaptor or included mounting kit for this model. Mounting hardware and connection details must be selected from the actual installation requirements; no unlisted tightening torque or screw depth is inferred. Safety Approvals and EMC Medical safety standards IEC 60601-1:2005+A1; TUV BS EN/EN 60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; EAC TP TC 004 approved. Additional design option Design reference to BS EN/EN60335-1 is by request; not a standard approval claim for this supplied model. Emissions BS EN/EN55011 (CISPR11): Class B conducted and radiated; BS EN/EN61000-3-2: Class A harmonic current; BS EN/EN61000-3-3: voltage flicker. Immunity BS EN/EN55035 and BS EN/EN60601-1-2. ESD, BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF field, -4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9, 9–28 V/m at 385 MHz–5.78 GHz. EFT, -4-4: Level 3, 2 kV. Surge, -4-5: Level 3, 1 kV line-to-line. Conducted immunity, -4-6: Level 3, 10 V. Magnetic field, -4-8: Level 4, 30 A/m. Voltage dips and interruptions, BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. The power supply is a component to be installed in final equipment. Re-confirm final-equipment EMC compliance under the manufacturer component-EMI guidance; component results alone are not approval of the assembled equipment. Weight, Reliability and Measurement Notes Catalogue unit-weight reference 206 g, converted from the explicit 0.206 kg PACKING reference per unit. This is not a measured net weight or a shipment weight. MTBF 4590.4 K hours minimum, Telcordia SR-332 (Bellcore); 563.4 K hours minimum, MIL-HDBK-217F at 25°C. Default test conditions 230 V AC input, rated load and 25°C ambient unless otherwise specified. Manufacturer warranty statement The catalogue lists three years; manufacturer terms apply. Datasheet version MPM-45-SPEC, 2024-10-30; combined catalogue pages 21–24. MTBF is a statistical reliability estimate, not a guaranteed service life. The unit-weight reference is taken directly from the specification, not obtained by dividing the carton weight.

  • MPM-45-24ST

    MEAN WELL MPM-45 series: Screw Terminal Medical AC/DC Power Supply - MPM-45-24ST

    MEAN WELL MPM-45-24ST is a screw terminal medical AC/DC power supply with 24 V output, 1.88 A rated current and 45.1 W catalogue-rated output power. It uses Class II construction without FG and provides 2 MOPP primary-secondary isolation. BF applications require appropriate system consideration; apply the model-specific peak, thermal and input-voltage limits. Product Datasheet Download MEAN WELL MPM-45 Datasheet (PDF) The MPM-45 section is on PDF pages 21, 22, 23, 24. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Selection Complete model MPM-45-24ST Series MPM-45 medical AC/DC power supply. Output code 24 V nominal DC output. Mounting suffix ST: screw terminal style. This version uses the specified mounting style and has the model-specific vibration rating stated below. Typical applications include portable medical devices, mobile clinical workstations, medical computer monitors and medical examination instruments. DC Output and Peak Operation Nominal DC voltage 24 V. Rated current 1.88 A. Rated cooling condition Natural convection; no minimum load required. Catalogue-rated output power 45.1 W. Peak current and power 2.1 A and 50.4 W for up to 10 seconds; subject to the duty and average-power limits below. Ripple and noise, maximum 200 mVp-p. Voltage tolerance ±2.0%; includes setup tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±0.5%. Peak operation is limited to a maximum 33% duty cycle within every 30 seconds. Average output power must not exceed the rated power. The peak rating is not a continuous-output allowance; observe the specified current and power limits together. Ripple and noise are measured at 20 MHz bandwidth with a 12-inch twisted-pair wire terminated by 0.1 µF and 47 µF capacitors in parallel. Use the catalogue-rated power, current and voltage as separate selection limits. Input and Timing Input voltage 80–264 V AC or 113–370 V DC. AC frequency 47–63 Hz. Efficiency, typical 92.5% at the default specified test conditions. AC current, typical 1.2 A at 115 V AC; 0.6 A at 230 V AC. Cold-start inrush, typical 30 A at 115 V AC; 60 A at 230 V AC. Setup / rise time 1000 ms / 30 ms at both 230 V AC and 115 V AC, full load. Hold-up time, typical 50 ms at 230 V AC; 12 ms at 115 V AC, full load. No-load consumption Less than 0.1 W. Protection and Medical Isolation Short circuit Short-circuit protection is listed. Overload 115–135% of rated output power; hiccup mode, automatic recovery after the fault is removed. Overvoltage 25.2–32.4 V; output shutdown, re-power to recover. Overtemperature Output shutdown, re-power to recover. Touch current Less than 100 µA at 264 V AC, measured from primary to DC output. Primary-secondary isolation 2 × MOPP. Construction Class II, without FG. Withstand voltage Input to output: 4 kV AC. Isolation resistance Input to output: 100 MΩ at 500 V DC, 25°C and 70% RH. Suitable for BF applications only with appropriate system consideration. These component ratings do not certify an assembled medical device or permit ignoring the final equipment insulation and leakage-current requirements. Cooling and Operating Limits Operating ambient −30 to +80°C; subject to the derating curve. Temperature derating Horizontal mounting, this output-voltage version: 100% load from −30 to +60°C, then along the plotted segments to 75% at +70°C and 40% at +80°C. Input-voltage derating The 60 Hz AC-input curve gives 80% load at 80 V AC, rising to 100% at 100 V AC and remaining at 100% to 264 V AC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C. Temperature coefficient ±0.03%/°C over 0–60°C. Operating altitude Up to 4000 m / overvoltage category II. Altitude derating For fanless operation above 2000 m (6500 ft), reduce permissible ambient temperature by 3.5°C per additional 1000 m. Vibration 5 G, 10–500 Hz, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Apply the temperature, input-voltage and altitude limits together. Maximum ambient temperature does not imply full rated output at that temperature. Peak operation must also stay within the average-power and duty-cycle limits. Dimensions, Connections and Installation Dimensions (L × W × H) 109 × 52 × 33.5 mm. Case reference IRM60. Drawing tolerance ±1 mm. Screw terminals Top view: input AC/N and AC/L at one end; output −Vo, −Vo, +Vo, +Vo at the opposite end. The repeated output terminals share the single output; they do not add current capacity. Mounting holes Four Ø3.5 mm holes; the drawing marks 98 × 33 mm between the mounting-hole positions. Terminal drawing dimensions Input-terminal pitch 7.5 mm; output-terminal pitches 5 mm. Follow the full mechanical drawing for clearance. Use the mechanical drawing for this mounting version and the manufacturer installation instructions. PCB and screw-terminal styles have different dimensions, connection layouts and vibration ratings; they are not interchangeable mounting patterns. The reviewed pages do not specify a separate accessory ordering code, mating connector, DIN-rail adaptor or included mounting kit for this model. Mounting hardware and connection details must be selected from the actual installation requirements; no unlisted tightening torque or screw depth is inferred. Safety Approvals and EMC Medical safety standards IEC 60601-1:2005+A1; TUV BS EN/EN 60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; EAC TP TC 004 approved. Additional design option Design reference to BS EN/EN60335-1 is by request; not a standard approval claim for this supplied model. Emissions BS EN/EN55011 (CISPR11): Class B conducted and radiated; BS EN/EN61000-3-2: Class A harmonic current; BS EN/EN61000-3-3: voltage flicker. Immunity BS EN/EN55035 and BS EN/EN60601-1-2. ESD, BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF field, -4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9, 9–28 V/m at 385 MHz–5.78 GHz. EFT, -4-4: Level 3, 2 kV. Surge, -4-5: Level 3, 1 kV line-to-line. Conducted immunity, -4-6: Level 3, 10 V. Magnetic field, -4-8: Level 4, 30 A/m. Voltage dips and interruptions, BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. The power supply is a component to be installed in final equipment. Re-confirm final-equipment EMC compliance under the manufacturer component-EMI guidance; component results alone are not approval of the assembled equipment. Weight, Reliability and Measurement Notes Catalogue unit-weight reference 206 g, converted from the explicit 0.206 kg PACKING reference per unit. This is not a measured net weight or a shipment weight. MTBF 4590.4 K hours minimum, Telcordia SR-332 (Bellcore); 563.4 K hours minimum, MIL-HDBK-217F at 25°C. Default test conditions 230 V AC input, rated load and 25°C ambient unless otherwise specified. Manufacturer warranty statement The catalogue lists three years; manufacturer terms apply. Datasheet version MPM-45-SPEC, 2024-10-30; combined catalogue pages 21–24. MTBF is a statistical reliability estimate, not a guaranteed service life. The unit-weight reference is taken directly from the specification, not obtained by dividing the carton weight.

  • MPM-45-15ST

    MEAN WELL MPM-45 series: Screw Terminal Medical AC/DC Power Supply - MPM-45-15ST

    MEAN WELL MPM-45-15ST is a screw terminal medical AC/DC power supply with 15 V output, 3 A rated current and 45 W catalogue-rated output power. It uses Class II construction without FG and provides 2 MOPP primary-secondary isolation. BF applications require appropriate system consideration; apply the model-specific peak, thermal and input-voltage limits. Product Datasheet Download MEAN WELL MPM-45 Datasheet (PDF) The MPM-45 section is on PDF pages 21, 22, 23, 24. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Selection Complete model MPM-45-15ST Series MPM-45 medical AC/DC power supply. Output code 15 V nominal DC output. Mounting suffix ST: screw terminal style. This version uses the specified mounting style and has the model-specific vibration rating stated below. Typical applications include portable medical devices, mobile clinical workstations, medical computer monitors and medical examination instruments. DC Output and Peak Operation Nominal DC voltage 15 V. Rated current 3 A. Rated cooling condition Natural convection; no minimum load required. Catalogue-rated output power 45 W. Peak current and power 3.3 A and 49.5 W for up to 10 seconds; subject to the duty and average-power limits below. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±2.0%; includes setup tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±0.5%. Peak operation is limited to a maximum 33% duty cycle within every 30 seconds. Average output power must not exceed the rated power. The peak rating is not a continuous-output allowance; observe the specified current and power limits together. Ripple and noise are measured at 20 MHz bandwidth with a 12-inch twisted-pair wire terminated by 0.1 µF and 47 µF capacitors in parallel. Use the catalogue-rated power, current and voltage as separate selection limits. Input and Timing Input voltage 80–264 V AC or 113–370 V DC. AC frequency 47–63 Hz. Efficiency, typical 92.5% at the default specified test conditions. AC current, typical 1.2 A at 115 V AC; 0.6 A at 230 V AC. Cold-start inrush, typical 30 A at 115 V AC; 60 A at 230 V AC. Setup / rise time 1000 ms / 30 ms at both 230 V AC and 115 V AC, full load. Hold-up time, typical 50 ms at 230 V AC; 12 ms at 115 V AC, full load. No-load consumption Less than 0.1 W. Protection and Medical Isolation Short circuit Short-circuit protection is listed. Overload 115–135% of rated output power; hiccup mode, automatic recovery after the fault is removed. Overvoltage 15.8–20.3 V; output shutdown, re-power to recover. Overtemperature Output shutdown, re-power to recover. Touch current Less than 100 µA at 264 V AC, measured from primary to DC output. Primary-secondary isolation 2 × MOPP. Construction Class II, without FG. Withstand voltage Input to output: 4 kV AC. Isolation resistance Input to output: 100 MΩ at 500 V DC, 25°C and 70% RH. Suitable for BF applications only with appropriate system consideration. These component ratings do not certify an assembled medical device or permit ignoring the final equipment insulation and leakage-current requirements. Cooling and Operating Limits Operating ambient −30 to +80°C; subject to the derating curve. Temperature derating Horizontal mounting, this output-voltage version: 100% load from −30 to +60°C, then along the plotted segments to 75% at +70°C and 40% at +80°C. Input-voltage derating The 60 Hz AC-input curve gives 80% load at 80 V AC, rising to 100% at 100 V AC and remaining at 100% to 264 V AC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C. Temperature coefficient ±0.03%/°C over 0–60°C. Operating altitude Up to 4000 m / overvoltage category II. Altitude derating For fanless operation above 2000 m (6500 ft), reduce permissible ambient temperature by 3.5°C per additional 1000 m. Vibration 5 G, 10–500 Hz, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Apply the temperature, input-voltage and altitude limits together. Maximum ambient temperature does not imply full rated output at that temperature. Peak operation must also stay within the average-power and duty-cycle limits. Dimensions, Connections and Installation Dimensions (L × W × H) 109 × 52 × 33.5 mm. Case reference IRM60. Drawing tolerance ±1 mm. Screw terminals Top view: input AC/N and AC/L at one end; output −Vo, −Vo, +Vo, +Vo at the opposite end. The repeated output terminals share the single output; they do not add current capacity. Mounting holes Four Ø3.5 mm holes; the drawing marks 98 × 33 mm between the mounting-hole positions. Terminal drawing dimensions Input-terminal pitch 7.5 mm; output-terminal pitches 5 mm. Follow the full mechanical drawing for clearance. Use the mechanical drawing for this mounting version and the manufacturer installation instructions. PCB and screw-terminal styles have different dimensions, connection layouts and vibration ratings; they are not interchangeable mounting patterns. The reviewed pages do not specify a separate accessory ordering code, mating connector, DIN-rail adaptor or included mounting kit for this model. Mounting hardware and connection details must be selected from the actual installation requirements; no unlisted tightening torque or screw depth is inferred. Safety Approvals and EMC Medical safety standards IEC 60601-1:2005+A1; TUV BS EN/EN 60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; EAC TP TC 004 approved. Additional design option Design reference to BS EN/EN60335-1 is by request; not a standard approval claim for this supplied model. Emissions BS EN/EN55011 (CISPR11): Class B conducted and radiated; BS EN/EN61000-3-2: Class A harmonic current; BS EN/EN61000-3-3: voltage flicker. Immunity BS EN/EN55035 and BS EN/EN60601-1-2. ESD, BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF field, -4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9, 9–28 V/m at 385 MHz–5.78 GHz. EFT, -4-4: Level 3, 2 kV. Surge, -4-5: Level 3, 1 kV line-to-line. Conducted immunity, -4-6: Level 3, 10 V. Magnetic field, -4-8: Level 4, 30 A/m. Voltage dips and interruptions, BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. The power supply is a component to be installed in final equipment. Re-confirm final-equipment EMC compliance under the manufacturer component-EMI guidance; component results alone are not approval of the assembled equipment. Weight, Reliability and Measurement Notes Catalogue unit-weight reference 206 g, converted from the explicit 0.206 kg PACKING reference per unit. This is not a measured net weight or a shipment weight. MTBF 4590.4 K hours minimum, Telcordia SR-332 (Bellcore); 563.4 K hours minimum, MIL-HDBK-217F at 25°C. Default test conditions 230 V AC input, rated load and 25°C ambient unless otherwise specified. Manufacturer warranty statement The catalogue lists three years; manufacturer terms apply. Datasheet version MPM-45-SPEC, 2024-10-30; combined catalogue pages 21–24. MTBF is a statistical reliability estimate, not a guaranteed service life. The unit-weight reference is taken directly from the specification, not obtained by dividing the carton weight.

  • MPM-45-12ST

    MEAN WELL MPM-45 series: Screw Terminal Medical AC/DC Power Supply - MPM-45-12ST

    MEAN WELL MPM-45-12ST is a screw terminal medical AC/DC power supply with 12 V output, 3.75 A rated current and 45 W catalogue-rated output power. It uses Class II construction without FG and provides 2 MOPP primary-secondary isolation. BF applications require appropriate system consideration; apply the model-specific peak, thermal and input-voltage limits. Product Datasheet Download MEAN WELL MPM-45 Datasheet (PDF) The MPM-45 section is on PDF pages 21, 22, 23, 24. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Selection Complete model MPM-45-12ST Series MPM-45 medical AC/DC power supply. Output code 12 V nominal DC output. Mounting suffix ST: screw terminal style. This version uses the specified mounting style and has the model-specific vibration rating stated below. Typical applications include portable medical devices, mobile clinical workstations, medical computer monitors and medical examination instruments. DC Output and Peak Operation Nominal DC voltage 12 V. Rated current 3.75 A. Rated cooling condition Natural convection; no minimum load required. Catalogue-rated output power 45 W. Peak current and power 4.13 A and 49.5 W for up to 10 seconds; subject to the duty and average-power limits below. Ripple and noise, maximum 120 mVp-p. Voltage tolerance ±2.0%; includes setup tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±1.0%. Peak operation is limited to a maximum 33% duty cycle within every 30 seconds. Average output power must not exceed the rated power. The peak rating is not a continuous-output allowance; observe the specified current and power limits together. Ripple and noise are measured at 20 MHz bandwidth with a 12-inch twisted-pair wire terminated by 0.1 µF and 47 µF capacitors in parallel. Use the catalogue-rated power, current and voltage as separate selection limits. Input and Timing Input voltage 80–264 V AC or 113–370 V DC. AC frequency 47–63 Hz. Efficiency, typical 91.5% at the default specified test conditions. AC current, typical 1.2 A at 115 V AC; 0.6 A at 230 V AC. Cold-start inrush, typical 30 A at 115 V AC; 60 A at 230 V AC. Setup / rise time 1000 ms / 30 ms at both 230 V AC and 115 V AC, full load. Hold-up time, typical 50 ms at 230 V AC; 12 ms at 115 V AC, full load. No-load consumption Less than 0.1 W. Protection and Medical Isolation Short circuit Short-circuit protection is listed. Overload 115–135% of rated output power; hiccup mode, automatic recovery after the fault is removed. Overvoltage 12.6–16.2 V; output shutdown, re-power to recover. Overtemperature Output shutdown, re-power to recover. Touch current Less than 100 µA at 264 V AC, measured from primary to DC output. Primary-secondary isolation 2 × MOPP. Construction Class II, without FG. Withstand voltage Input to output: 4 kV AC. Isolation resistance Input to output: 100 MΩ at 500 V DC, 25°C and 70% RH. Suitable for BF applications only with appropriate system consideration. These component ratings do not certify an assembled medical device or permit ignoring the final equipment insulation and leakage-current requirements. Cooling and Operating Limits Operating ambient −30 to +80°C; subject to the derating curve. Temperature derating Horizontal mounting, this output-voltage version: 100% load from −30 to +60°C, then along the plotted segments to 75% at +70°C and 40% at +80°C. Input-voltage derating The 60 Hz AC-input curve gives 80% load at 80 V AC, rising to 100% at 100 V AC and remaining at 100% to 264 V AC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C. Temperature coefficient ±0.03%/°C over 0–60°C. Operating altitude Up to 4000 m / overvoltage category II. Altitude derating For fanless operation above 2000 m (6500 ft), reduce permissible ambient temperature by 3.5°C per additional 1000 m. Vibration 5 G, 10–500 Hz, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Apply the temperature, input-voltage and altitude limits together. Maximum ambient temperature does not imply full rated output at that temperature. Peak operation must also stay within the average-power and duty-cycle limits. Dimensions, Connections and Installation Dimensions (L × W × H) 109 × 52 × 33.5 mm. Case reference IRM60. Drawing tolerance ±1 mm. Screw terminals Top view: input AC/N and AC/L at one end; output −Vo, −Vo, +Vo, +Vo at the opposite end. The repeated output terminals share the single output; they do not add current capacity. Mounting holes Four Ø3.5 mm holes; the drawing marks 98 × 33 mm between the mounting-hole positions. Terminal drawing dimensions Input-terminal pitch 7.5 mm; output-terminal pitches 5 mm. Follow the full mechanical drawing for clearance. Use the mechanical drawing for this mounting version and the manufacturer installation instructions. PCB and screw-terminal styles have different dimensions, connection layouts and vibration ratings; they are not interchangeable mounting patterns. The reviewed pages do not specify a separate accessory ordering code, mating connector, DIN-rail adaptor or included mounting kit for this model. Mounting hardware and connection details must be selected from the actual installation requirements; no unlisted tightening torque or screw depth is inferred. Safety Approvals and EMC Medical safety standards IEC 60601-1:2005+A1; TUV BS EN/EN 60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; EAC TP TC 004 approved. Additional design option Design reference to BS EN/EN60335-1 is by request; not a standard approval claim for this supplied model. Emissions BS EN/EN55011 (CISPR11): Class B conducted and radiated; BS EN/EN61000-3-2: Class A harmonic current; BS EN/EN61000-3-3: voltage flicker. Immunity BS EN/EN55035 and BS EN/EN60601-1-2. ESD, BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF field, -4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9, 9–28 V/m at 385 MHz–5.78 GHz. EFT, -4-4: Level 3, 2 kV. Surge, -4-5: Level 3, 1 kV line-to-line. Conducted immunity, -4-6: Level 3, 10 V. Magnetic field, -4-8: Level 4, 30 A/m. Voltage dips and interruptions, BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. The power supply is a component to be installed in final equipment. Re-confirm final-equipment EMC compliance under the manufacturer component-EMI guidance; component results alone are not approval of the assembled equipment. Weight, Reliability and Measurement Notes Catalogue unit-weight reference 206 g, converted from the explicit 0.206 kg PACKING reference per unit. This is not a measured net weight or a shipment weight. MTBF 4590.4 K hours minimum, Telcordia SR-332 (Bellcore); 563.4 K hours minimum, MIL-HDBK-217F at 25°C. Default test conditions 230 V AC input, rated load and 25°C ambient unless otherwise specified. Manufacturer warranty statement The catalogue lists three years; manufacturer terms apply. Datasheet version MPM-45-SPEC, 2024-10-30; combined catalogue pages 21–24. MTBF is a statistical reliability estimate, not a guaranteed service life. The unit-weight reference is taken directly from the specification, not obtained by dividing the carton weight.

  • MPM-45-5ST

    MEAN WELL MPM-45 series: Screw Terminal Medical AC/DC Power Supply - MPM-45-5ST

    MEAN WELL MPM-45-5ST is a screw terminal medical AC/DC power supply with 5 V output, 8 A rated current and 40 W catalogue-rated output power. It uses Class II construction without FG and provides 2 MOPP primary-secondary isolation. BF applications require appropriate system consideration; apply the model-specific peak, thermal and input-voltage limits. Product Datasheet Download MEAN WELL MPM-45 Datasheet (PDF) The MPM-45 section is on PDF pages 21, 22, 23, 24. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Selection Complete model MPM-45-5ST Series MPM-45 medical AC/DC power supply. Output code 5 V nominal DC output. Mounting suffix ST: screw terminal style. This version uses the specified mounting style and has the model-specific vibration rating stated below. Typical applications include portable medical devices, mobile clinical workstations, medical computer monitors and medical examination instruments. DC Output and Peak Operation Nominal DC voltage 5 V. Rated current 8 A. Rated cooling condition Natural convection; no minimum load required. Catalogue-rated output power 40 W. Peak current and power 8.8 A and 44 W for up to 10 seconds; subject to the duty and average-power limits below. Ripple and noise, maximum 80 mVp-p. Voltage tolerance ±2.0%; includes setup tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±1.0%. Peak operation is limited to a maximum 33% duty cycle within every 30 seconds. Average output power must not exceed the rated power. The peak rating is not a continuous-output allowance; observe the specified current and power limits together. Ripple and noise are measured at 20 MHz bandwidth with a 12-inch twisted-pair wire terminated by 0.1 µF and 47 µF capacitors in parallel. Use the catalogue-rated power, current and voltage as separate selection limits. Input and Timing Input voltage 80–264 V AC or 113–370 V DC. AC frequency 47–63 Hz. Efficiency, typical 88% at the default specified test conditions. AC current, typical 1.2 A at 115 V AC; 0.6 A at 230 V AC. Cold-start inrush, typical 30 A at 115 V AC; 60 A at 230 V AC. Setup / rise time 1000 ms / 30 ms at both 230 V AC and 115 V AC, full load. Hold-up time, typical 50 ms at 230 V AC; 12 ms at 115 V AC, full load. No-load consumption Less than 0.1 W. Protection and Medical Isolation Short circuit Short-circuit protection is listed. Overload 115–135% of rated output power; hiccup mode, automatic recovery after the fault is removed. Overvoltage 5.3–7.2 V; output shutdown, re-power to recover. Overtemperature Output shutdown, re-power to recover. Touch current Less than 100 µA at 264 V AC, measured from primary to DC output. Primary-secondary isolation 2 × MOPP. Construction Class II, without FG. Withstand voltage Input to output: 4 kV AC. Isolation resistance Input to output: 100 MΩ at 500 V DC, 25°C and 70% RH. Suitable for BF applications only with appropriate system consideration. These component ratings do not certify an assembled medical device or permit ignoring the final equipment insulation and leakage-current requirements. Cooling and Operating Limits Operating ambient −30 to +80°C; subject to the derating curve. Temperature derating Horizontal mounting, 5 V version: 100% load from −30 to +55°C, then along the plotted segments to 75% at +70°C and 40% at +80°C. Input-voltage derating The 60 Hz AC-input curve gives 80% load at 80 V AC, rising to 100% at 100 V AC and remaining at 100% to 264 V AC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C. Temperature coefficient ±0.03%/°C over 0–60°C. Operating altitude Up to 4000 m / overvoltage category II. Altitude derating For fanless operation above 2000 m (6500 ft), reduce permissible ambient temperature by 3.5°C per additional 1000 m. Vibration 5 G, 10–500 Hz, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Apply the temperature, input-voltage and altitude limits together. Maximum ambient temperature does not imply full rated output at that temperature. Peak operation must also stay within the average-power and duty-cycle limits. Dimensions, Connections and Installation Dimensions (L × W × H) 109 × 52 × 33.5 mm. Case reference IRM60. Drawing tolerance ±1 mm. Screw terminals Top view: input AC/N and AC/L at one end; output −Vo, −Vo, +Vo, +Vo at the opposite end. The repeated output terminals share the single output; they do not add current capacity. Mounting holes Four Ø3.5 mm holes; the drawing marks 98 × 33 mm between the mounting-hole positions. Terminal drawing dimensions Input-terminal pitch 7.5 mm; output-terminal pitches 5 mm. Follow the full mechanical drawing for clearance. Use the mechanical drawing for this mounting version and the manufacturer installation instructions. PCB and screw-terminal styles have different dimensions, connection layouts and vibration ratings; they are not interchangeable mounting patterns. The reviewed pages do not specify a separate accessory ordering code, mating connector, DIN-rail adaptor or included mounting kit for this model. Mounting hardware and connection details must be selected from the actual installation requirements; no unlisted tightening torque or screw depth is inferred. Safety Approvals and EMC Medical safety standards IEC 60601-1:2005+A1; TUV BS EN/EN 60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; EAC TP TC 004 approved. Additional design option Design reference to BS EN/EN60335-1 is by request; not a standard approval claim for this supplied model. Emissions BS EN/EN55011 (CISPR11): Class B conducted and radiated; BS EN/EN61000-3-2: Class A harmonic current; BS EN/EN61000-3-3: voltage flicker. Immunity BS EN/EN55035 and BS EN/EN60601-1-2. ESD, BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF field, -4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9, 9–28 V/m at 385 MHz–5.78 GHz. EFT, -4-4: Level 3, 2 kV. Surge, -4-5: Level 3, 1 kV line-to-line. Conducted immunity, -4-6: Level 3, 10 V. Magnetic field, -4-8: Level 4, 30 A/m. Voltage dips and interruptions, BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. The power supply is a component to be installed in final equipment. Re-confirm final-equipment EMC compliance under the manufacturer component-EMI guidance; component results alone are not approval of the assembled equipment. Weight, Reliability and Measurement Notes Catalogue unit-weight reference 206 g, converted from the explicit 0.206 kg PACKING reference per unit. This is not a measured net weight or a shipment weight. MTBF 4590.4 K hours minimum, Telcordia SR-332 (Bellcore); 563.4 K hours minimum, MIL-HDBK-217F at 25°C. Default test conditions 230 V AC input, rated load and 25°C ambient unless otherwise specified. Manufacturer warranty statement The catalogue lists three years; manufacturer terms apply. Datasheet version MPM-45-SPEC, 2024-10-30; combined catalogue pages 21–24. MTBF is a statistical reliability estimate, not a guaranteed service life. The unit-weight reference is taken directly from the specification, not obtained by dividing the carton weight.

  • MPM-45-48

    MEAN WELL MPM-45 series: PCB Mount Medical AC/DC Power Supply - MPM-45-48

    MEAN WELL MPM-45-48 is a pcb mount medical AC/DC power supply with 48 V output, 0.94 A rated current and 45.1 W catalogue-rated output power. It uses Class II construction without FG and provides 2 MOPP primary-secondary isolation. BF applications require appropriate system consideration; apply the model-specific peak, thermal and input-voltage limits. Product Datasheet Download MEAN WELL MPM-45 Datasheet (PDF) The MPM-45 section is on PDF pages 21, 22, 23, 24. Refer to the complete mechanical drawings and notes when planning installation. Model Code and Selection Complete model MPM-45-48 Series MPM-45 medical AC/DC power supply. Output code 48 V nominal DC output. Mounting suffix Blank suffix: PCB mounting style. This version uses the specified mounting style and has the model-specific vibration rating stated below. Typical applications include portable medical devices, mobile clinical workstations, medical computer monitors and medical examination instruments. DC Output and Peak Operation Nominal DC voltage 48 V. Rated current 0.94 A. Rated cooling condition Natural convection; no minimum load required. Catalogue-rated output power 45.1 W. Peak current and power 1.05 A and 50.4 W for up to 10 seconds; subject to the duty and average-power limits below. Ripple and noise, maximum 240 mVp-p. Voltage tolerance ±2.0%; includes setup tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±0.5%. Peak operation is limited to a maximum 33% duty cycle within every 30 seconds. Average output power must not exceed the rated power. The peak rating is not a continuous-output allowance; observe the specified current and power limits together. Ripple and noise are measured at 20 MHz bandwidth with a 12-inch twisted-pair wire terminated by 0.1 µF and 47 µF capacitors in parallel. Use the catalogue-rated power, current and voltage as separate selection limits. Input and Timing Input voltage 80–264 V AC or 113–370 V DC. AC frequency 47–63 Hz. Efficiency, typical 92% at the default specified test conditions. AC current, typical 1.2 A at 115 V AC; 0.6 A at 230 V AC. Cold-start inrush, typical 30 A at 115 V AC; 60 A at 230 V AC. Setup / rise time 1000 ms / 30 ms at both 230 V AC and 115 V AC, full load. Hold-up time, typical 50 ms at 230 V AC; 12 ms at 115 V AC, full load. No-load consumption Less than 0.1 W. Protection and Medical Isolation Short circuit Short-circuit protection is listed. Overload 115–135% of rated output power; hiccup mode, automatic recovery after the fault is removed. Overvoltage 50.4–64.8 V; output shutdown, re-power to recover. Overtemperature Output shutdown, re-power to recover. Touch current Less than 100 µA at 264 V AC, measured from primary to DC output. Primary-secondary isolation 2 × MOPP. Construction Class II, without FG. Withstand voltage Input to output: 4 kV AC. Isolation resistance Input to output: 100 MΩ at 500 V DC, 25°C and 70% RH. Suitable for BF applications only with appropriate system consideration. These component ratings do not certify an assembled medical device or permit ignoring the final equipment insulation and leakage-current requirements. Cooling and Operating Limits Operating ambient −30 to +80°C; subject to the derating curve. Temperature derating Horizontal mounting, this output-voltage version: 100% load from −30 to +60°C, then along the plotted segments to 75% at +70°C and 40% at +80°C. Input-voltage derating The 60 Hz AC-input curve gives 80% load at 80 V AC, rising to 100% at 100 V AC and remaining at 100% to 264 V AC. Working humidity 20–90% RH, non-condensing. Storage −40 to +85°C. Temperature coefficient ±0.03%/°C over 0–60°C. Operating altitude Up to 4000 m / overvoltage category II. Altitude derating For fanless operation above 2000 m (6500 ft), reduce permissible ambient temperature by 3.5°C per additional 1000 m. Vibration 2 G, 10–500 Hz, 10 minutes per cycle; 60 minutes along each X, Y and Z axis. Apply the temperature, input-voltage and altitude limits together. Maximum ambient temperature does not imply full rated output at that temperature. Peak operation must also stay within the average-power and duty-cycle limits. Dimensions, Connections and Installation Dimensions (L × W × H) 87 × 52 × 29.5 mm. Case reference IRM60. Drawing tolerance ±1 mm. PCB power pins Bottom view: AC/N above AC/L at the input side; −Vo above +Vo at the output side. The figure orientation matters. Pin and layout dimensions AC/L and AC/N pins are Ø1 mm; +Vo and −Vo pins are Ø2 mm. Protrusion is 3.5 ±1 mm; the bottom view marks 76 mm between pin columns, 6.75 mm between input pins and 5.5 mm between output pins. Soldering limits Wave soldering: 265°C for 5 seconds maximum. Manual soldering: 390°C for 3 seconds maximum. Use the mechanical drawing for this mounting version and the manufacturer installation instructions. PCB and screw-terminal styles have different dimensions, connection layouts and vibration ratings; they are not interchangeable mounting patterns. The reviewed pages do not specify a separate accessory ordering code, mating connector, DIN-rail adaptor or included mounting kit for this model. Mounting hardware and connection details must be selected from the actual installation requirements; no unlisted tightening torque or screw depth is inferred. Safety Approvals and EMC Medical safety standards IEC 60601-1:2005+A1; TUV BS EN/EN 60601-1:2006+A1+A12+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; EAC TP TC 004 approved. Additional design option Design reference to BS EN/EN60335-1 is by request; not a standard approval claim for this supplied model. Emissions BS EN/EN55011 (CISPR11): Class B conducted and radiated; BS EN/EN61000-3-2: Class A harmonic current; BS EN/EN61000-3-3: voltage flicker. Immunity BS EN/EN55035 and BS EN/EN60601-1-2. ESD, BS EN/EN61000-4-2: Level 4, 15 kV air and 8 kV contact. RF field, -4-3: Level 3, 10 V/m at 80 MHz–2.7 GHz; Table 9, 9–28 V/m at 385 MHz–5.78 GHz. EFT, -4-4: Level 3, 2 kV. Surge, -4-5: Level 3, 1 kV line-to-line. Conducted immunity, -4-6: Level 3, 10 V. Magnetic field, -4-8: Level 4, 30 A/m. Voltage dips and interruptions, BS EN/EN61000-4-11: >95% dip for 0.5 periods; 30% dip for 25 periods; >95% interruption for 250 periods. The power supply is a component to be installed in final equipment. Re-confirm final-equipment EMC compliance under the manufacturer component-EMI guidance; component results alone are not approval of the assembled equipment. Weight, Reliability and Measurement Notes Catalogue unit-weight reference 185 g, converted from the explicit 0.185 kg PACKING reference per unit. This is not a measured net weight or a shipment weight. MTBF 4590.4 K hours minimum, Telcordia SR-332 (Bellcore); 563.4 K hours minimum, MIL-HDBK-217F at 25°C. Default test conditions 230 V AC input, rated load and 25°C ambient unless otherwise specified. Manufacturer warranty statement The catalogue lists three years; manufacturer terms apply. Datasheet version MPM-45-SPEC, 2024-10-30; combined catalogue pages 21–24. MTBF is a statistical reliability estimate, not a guaranteed service life. The unit-weight reference is taken directly from the specification, not obtained by dividing the carton weight.


You have seen 24 out of 60 products