MSP:Single Output Medical Grade Switching Power Supply

44 products

MEAN WELL MSP Series Premium Medical Power Supply

Complete Portfolio: 100W to 1600W | MOOP/MOPP Safety | Ultra-Low Leakage Current | 5-Year Warranty

  • Medical Overview
  • Low-Mid Power (100W~300W)
  • High Power (450W~1600W)
  • Smart Control Features
  • Safety & Dimensions

Engineered for Critical Medical Applications

The MEAN WELL MSP Series represents the highest standard in medical-grade enclosed power supplies. Ranging from 100W to 1600W, this family is rigorously tested and certified to international medical safety standards, ensuring maximum patient and operator protection in clinical environments.

Core Medical Advantages

  • Strict Safety Isolation: Achieves basic medical safety levels (MOOP), with the flagship MSP-1600 achieving 2xMOPP (Means of Patient Protection) primary-to-secondary isolation.
  • Ultra-Low Leakage Current: Engineered for safety with earth leakage current typically below 300μA (or <500μA on highest power models) and touch current below 100μA.
  • High Reliability Design: Built with 105°C long-life electrolytic capacitors, high efficiency topologies (up to 92%), and backed by a comprehensive 5-year warranty.
  • Surge Immunity: Capable of withstanding a 300VAC input surge for 5 seconds without damage.

MSP-100, MSP-200, & MSP-300 Specifications

The lower wattage segments are highly compact (1U low profile, 38mm~41mm height) and designed for quieter operation. The 100W and 200W models rely completely on free air convection cooling.

Model Series Max Power Available DC Voltages Max Efficiency Cooling Method
MSP-100 100W 3.3V, 5V, 7.5V, 12V, 15V, 24V, 36V, 48V Up to 90% Free Air Convection
MSP-200 200W 3.3V, 5V, 7.5V, 12V, 15V, 24V, 36V, 48V Up to 89% Free Air Convection
MSP-300 300W 3.3V, 5V, 7.5V, 12V, 15V, 24V, 36V, 48V Up to 89% Built-in Fan (Speed Controlled)
Energy Saving: All models in this tier feature exceptionally low no-load power consumption (< 0.5W), making them compliant with eco-design requirements.

MSP-450, MSP-600, MSP-1000 & MSP-1600 Specifications

For demanding medical imaging, lab automation, and high-power diagnostic equipment, the mid-to-high wattage MSP series delivers robust power with active thermal management and active PFC.

Model Series Max Power Available DC Voltages Max Efficiency Active PFC
MSP-450 450W 3.3V, 5V, 7.5V, 12V, 15V, 24V, 36V, 48V Up to 89.5% PF > 0.95
MSP-600 600W 3.3V, 5V, 7.5V, 12V, 15V, 24V, 36V, 48V Up to 89% PF > 0.93
MSP-1000 1000W 12V, 15V, 24V, 48V Up to 94% PF > 0.95
MSP-1600 1600W 12V, 24V, 36V, 48V Up to 92% PF > 0.97

Advanced Controls & System Integration

Starting from the MSP-200 series and up, MEAN WELL has integrated extensive auxiliary functions to serve modern, digitized medical equipment.

Auxiliary & Diagnostic Signals

  • Remote ON/OFF: Standard on all models, allowing the main power to be toggled electronically via a remote signal.
  • 5V Standby Output: Models from 200W~1000W include an independent 5V@0.3A (or 5V@0.3A~0.5A depending on model) standby circuit to keep logic controllers awake. (Note: MSP-1600 features 12V@0.8A Aux).
  • DC OK Signal: Provides a TTL or relay contact signal to notify the system motherboard that the power output is stable.
  • Remote Sense: Compensates for voltage drops across the output wiring (compensates up to 0.5V).

Flagship Capabilities (MSP-1000 / MSP-1600)

  • Current Sharing (Paralleling): The MSP-600 (up to 2400W) and MSP-1000 (up to 4000W) support active current sharing to scale power seamlessly.
  • Programmable Voltage (PV): The MSP-1600 allows output voltage to be trimmed dynamically from 15% to 115% via an external signal.
  • Digital Communication: The MSP-1600 is equipped with built-in CANBus (PMBus optional) for deep system diagnostics, control, and remote monitoring.

Medical Certifications & Physical Dimensions

Medical Standards Compliance

  • Global Safety: Approved to IEC 60601-1, ANSI/AAMI ES60601-1, TUV EN60601-1.
  • Isolation Level: General series operates at MOOP (Means of Operator Protection). The flagship MSP-1600 operates at the strictest 2xMOPP (Primary to Secondary).
  • EMC Immunity: Meets rigorous medical EMC standards (EN55011 Class B).

Dimensions (L * W * H)

Model Length Width Height (Profile)
MSP-100 159 mm 97 mm 38 mm (1U)
MSP-200 199 mm 98 mm 38 mm (1U)
MSP-300 199 mm 105 mm 41 mm
MSP-450 218 mm 105 mm 41 mm
MSP-600 218 mm 105 mm 63.5 mm
MSP-1000 218 mm 105 mm 63.5 mm
MSP-1600 310 mm 85 mm 41 mm
  • MSP-1000-48

    MEAN WELL MSP-1000 series: Medical AC/DC Power Supply - MSP-1000-48

    MEAN WELL MSP-1000-48 is a single-output enclosed medical AC/DC power supply rated at 48 V, 21 A and 1008 W. Active current sharing is available under the specified parallel-operation limits. Select the load using the output rating and both ambient-temperature and input-voltage derating curves. Product Datasheet Download MEAN WELL MSP-1000 Datasheet (PDF) The MSP-1000 section is on PDF pages 17, 18, 19, 20, 21, 22. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model MSP-1000-48 Model code MSP identifies the series; 1000 is the power-class designation; 48 identifies the nominal DC output voltage. Use the actual rating below for this model. Rated DC output 48 V / 21 A / 1008 W Current range 0–21 A Built-in voltage adjustment 46–56 V, using SVR1; respect the rated current and power limits. Ripple and noise 250 mVp-p maximum; 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±1.0%, including setup tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±0.5% Efficiency 94% typical under the stated measurement conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. Input and Startup Input range 90–264 VAC, 127–370 VDC; universal AC input with active PFC. The low-line curve limits usable output. Frequency / surge tolerance 47–63 Hz; withstands 300 VAC surge input for 5 seconds. Power factor PF >0.95 at 230 VAC and >0.98 at 115 VAC, typical at full load. Input current 8.5 A at 115 VAC / 5 A at 230 VAC, typical. Inrush current 20 A at 115 VAC / 40 A at 230 VAC, typical; active inrush-current limiting is shown in the block diagram. Setup / rise time 1000 ms / 50 ms at 230 VAC; 2000 ms / 50 ms at 115 VAC, at full load. Hold-up time 16 ms at 230 VAC and 16 ms at 115 VAC, typical at full load. Setup time is measured at the first cold start; repeated power cycling can increase it. Below 40 VAC, performance may degrade and the final-equipment manufacturer must reconfirm basic safety and essential performance; this note does not extend the rated input range. Protection Short circuit / overload Short-circuit protection is listed. Overload threshold: 105–135% of rated output power; constant-current limiting with automatic recovery after the fault is removed. Over-voltage protection 58–65 V; output shuts down and requires re-powering to recover. Over-temperature protection Output shuts down and automatically recovers after temperature decreases. Remote Control, Standby and DC-OK Remote ON/OFF CN100 pin 3 (RC+) to pin 4 (RC-): short = ON; open = OFF. Remote-off no-load consumption <0.75 W with RC+ and RC- open. Standby auxiliary output 5 V / 0.3 A; 4.75–5.25 V, ±5% tolerance, 50 mVp-p maximum ripple. AUX pin 2 is referenced to AUXG pin 1 and is not switched off by remote ON/OFF. DC-OK signal TTL output, referenced to CN100 GND pin 6 or 8: 3.3–5.6 V when the supply is ON; 0–1 V when OFF. Remote sense Up to 0.5 V load-wiring drop compensation. Connect +S pin 9 to load positive and -S pin 10 to load negative; twist the sense pair to minimize pickup. CN100 Control Connector Pin 1 — AUXG Auxiliary-output ground. Pin 2 — AUX Auxiliary voltage output, referenced to pin 1; 0.3 A maximum. Pins 3 / 4 — RC+ / RC- Remote-control input and return: short = ON; open = OFF. Pin 5 — CS Current-share signal; interconnect CS pins when using the supported parallel arrangement. Pins 6 / 8 — GND Connected to output -V; DC-OK signal return. Pin 7 — DC-OK TTL status signal, HIGH when the supply turns on; referenced to pin 8. Pins 9 / 10 — +S / -S Positive and negative remote sense; connect as shown in the model-specific wiring diagram. Parallel Operation Use short, large-diameter output wiring. Maximum total parallel current = rated current per unit × number of units × 0.9. Up to four units are shown; follow the complete manufacturer interconnection diagram, including CS, GND and sense wiring. The output-voltage difference between parallel units must be less than 0.2 V. Below 5% of the total rated current, current sharing may not be fully balanced. The catalogue describes the family as up to 4000 W (3+1), but the model-specific current formula and derating limits still apply. Cooling, Derating and Environment Temperature and load The specification lists -40 to +70°C subject to the derating curve. Horizontal mounting, 24/48 V branch: 100% load through +60°C, declining to 60% at +70°C. Input-voltage derating At 60 Hz, the input curve rises from 80% load at 90 VAC to 100% at 200 VAC, remaining at 100% through 264 VAC. Cooling / fan control Built-in cooling fan with ON/OFF control by internal NTC RT50 or 30% load minimum, as stated in the specification. The catalogue does not give a numeric ambient switching temperature for this sensor. Working humidity 20–90% RH, non-condensing. Storage -40 to +85°C and 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Altitude derating For this fan-cooled supply, reduce the permissible ambient temperature by 5°C per additional 1000 m above 2000 m (6500 ft), as specified in the catalogue note. Temperature and low-input-voltage limits apply together; the upper working-temperature figure does not mean full rated power is available at every input voltage. Dimensions, Terminals and Installation Overall dimensions 218 × 105 × 63.5 mm (L × W × H); case 977. Mechanical drawing tolerance ±0.5 mm. Mounting-hole labels Bottom: 4-M4 L=6; sides: 8-M4 L=4 (both sides). Use the complete drawing for thread engagement and hole positions; these labels are not accessory ordering codes. Hole-position references The drawing marks 152.4 mm spacing, a 32.8 mm end reference, and the 20.75/63.5 mm transverse references; side-view references include 38.3 and 12.5 mm. Follow the full drawing for each datum. AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG protective earth. DC output terminals 1–3 = +V; 4–6 = -V. Confirm polarity against this model’s terminal diagram. Terminal drawing dimensions The AC side marks 10 and 8.2 mm; the DC side marks 11 and 9.2 mm. These are drawing dimensions at their indicated locations, not a claim that every value is terminal pitch. Terminal projections AC-input side: 12 mm maximum; DC-output side: 18 mm maximum. Airflow and adjustment The mechanical drawing arrow points outward at the fan/input end. Keep the indicated airflow path unobstructed. The drawing identifies the LED and SVR1 output-voltage adjustment. Connector Mating Parts CN100 board connector HRS DF11-10DP-2DS or equivalent. Mating housing HRS DF11-10DS or equivalent, as listed for CN100. Mating terminal HRS DF11-**SC or equivalent is the printed terminal family; ** is not a confirmed orderable suffix. The catalogue identifies these mating parts but does not state that a cable, housing, terminals or mounting screws are included. Confirm the exact terminal suffix and wiring requirements before ordering; do not infer a complete accessory kit. Medical Safety, Leakage and Insulation Medical isolation Primary–secondary: 2 × MOPP; primary–earth: 1 × MOPP; secondary–earth: 1 × MOPP. Safety standards IEC 60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; EAC TP TC 004 approved. Design references include BS EN/EN60335-1 and BS EN/EN62368-1 (by request). Leakage current Earth leakage <360 µA at 264 VAC; touch leakage <100 µA at 264 VAC. Withstand voltage Input–output: 4.5 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance 100 MΩ for input–output, input–FG and output–FG, tested at 500 VDC / 25°C / 70% RH. The catalogue states suitability for BF applications with appropriate system consideration. The supply is a component; this does not certify the finished medical equipment or its patient connections. EMC and Integration Conditions Conducted / radiated emissions BS EN/EN55011 (CISPR11), Class B for each. Harmonic current / flicker BS EN/EN61000-3-2 Class A; BS EN/EN61000-3-3. Immunity standards BS EN/EN55035 and BS EN/EN60601-1-2. ESD BS EN/EN61000-4-2, Level 4: 15 kV air and 8 kV contact. Radiated RF / EFT-burst / conducted RF BS EN/EN61000-4-3, -4 and -6 respectively: Level 3. Surge BS EN/EN61000-4-5, Level 4: 2 kV line-to-line / 4 kV line-to-earth. Magnetic field BS EN/EN61000-4-8, Level 4. Dips / interruptions BS EN/EN61000-4-11: 100% dip for 1 period; 30% dip for 25 periods; 100% interruption for 250 periods. EMC testing uses the supply mounted on a 360 × 700 mm metal plate, 1 mm thick. This is a component-level test arrangement, not a statement that a plate is included. Reconfirm EMC compliance in the final equipment using the manufacturer’s component-power-supply guidance. Weight, Reliability and Catalogue Reference Catalogue unit weight 1530 g; catalogue packing reference per unit (1.53 kg in PACKING), not a measured net weight or shipment weight. MTBF 850.5 K hours minimum, Telcordia SR-332 (Bellcore); 105.8 K hours minimum, MIL-HDBK-217F at 25°C. These figures are reliability references, not a guaranteed service-life duration. Switching-frequency diagram PWM oscillator: 65 kHz. PFC oscillator: 90 kHz. Manufacturer warranty statement The manufacturer catalogue lists a five-year warranty, subject to the applicable manufacturer terms. Applicable datasheet MSP-1000-SPEC, 2025-01-23; PDF pages 17, 18, 19, 20, 21, 22.

    $528.34

  • MSP-1000-24

    MEAN WELL MSP-1000 series: Medical AC/DC Power Supply - MSP-1000-24

    MEAN WELL MSP-1000-24 is a single-output enclosed medical AC/DC power supply rated at 24 V, 42 A and 1008 W. Active current sharing is available under the specified parallel-operation limits. Select the load using the output rating and both ambient-temperature and input-voltage derating curves. Product Datasheet Download MEAN WELL MSP-1000 Datasheet (PDF) The MSP-1000 section is on PDF pages 17, 18, 19, 20, 21, 22. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model MSP-1000-24 Model code MSP identifies the series; 1000 is the power-class designation; 24 identifies the nominal DC output voltage. Use the actual rating below for this model. Rated DC output 24 V / 42 A / 1008 W Current range 0–42 A Built-in voltage adjustment 22–28 V, using SVR1; respect the rated current and power limits. Ripple and noise 200 mVp-p maximum; 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±1.0%, including setup tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±0.5% Efficiency 93% typical under the stated measurement conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. Input and Startup Input range 90–264 VAC, 127–370 VDC; universal AC input with active PFC. The low-line curve limits usable output. Frequency / surge tolerance 47–63 Hz; withstands 300 VAC surge input for 5 seconds. Power factor PF >0.95 at 230 VAC and >0.98 at 115 VAC, typical at full load. Input current 8.5 A at 115 VAC / 5 A at 230 VAC, typical. Inrush current 20 A at 115 VAC / 40 A at 230 VAC, typical; active inrush-current limiting is shown in the block diagram. Setup / rise time 1000 ms / 50 ms at 230 VAC; 2000 ms / 50 ms at 115 VAC, at full load. Hold-up time 16 ms at 230 VAC and 16 ms at 115 VAC, typical at full load. Setup time is measured at the first cold start; repeated power cycling can increase it. Below 40 VAC, performance may degrade and the final-equipment manufacturer must reconfirm basic safety and essential performance; this note does not extend the rated input range. Protection Short circuit / overload Short-circuit protection is listed. Overload threshold: 105–135% of rated output power; constant-current limiting with automatic recovery after the fault is removed. Over-voltage protection 29–33 V; output shuts down and requires re-powering to recover. Over-temperature protection Output shuts down and automatically recovers after temperature decreases. Remote Control, Standby and DC-OK Remote ON/OFF CN100 pin 3 (RC+) to pin 4 (RC-): short = ON; open = OFF. Remote-off no-load consumption <0.75 W with RC+ and RC- open. Standby auxiliary output 5 V / 0.3 A; 4.75–5.25 V, ±5% tolerance, 50 mVp-p maximum ripple. AUX pin 2 is referenced to AUXG pin 1 and is not switched off by remote ON/OFF. DC-OK signal TTL output, referenced to CN100 GND pin 6 or 8: 3.3–5.6 V when the supply is ON; 0–1 V when OFF. Remote sense Up to 0.5 V load-wiring drop compensation. Connect +S pin 9 to load positive and -S pin 10 to load negative; twist the sense pair to minimize pickup. CN100 Control Connector Pin 1 — AUXG Auxiliary-output ground. Pin 2 — AUX Auxiliary voltage output, referenced to pin 1; 0.3 A maximum. Pins 3 / 4 — RC+ / RC- Remote-control input and return: short = ON; open = OFF. Pin 5 — CS Current-share signal; interconnect CS pins when using the supported parallel arrangement. Pins 6 / 8 — GND Connected to output -V; DC-OK signal return. Pin 7 — DC-OK TTL status signal, HIGH when the supply turns on; referenced to pin 8. Pins 9 / 10 — +S / -S Positive and negative remote sense; connect as shown in the model-specific wiring diagram. Parallel Operation Use short, large-diameter output wiring. Maximum total parallel current = rated current per unit × number of units × 0.9. Up to four units are shown; follow the complete manufacturer interconnection diagram, including CS, GND and sense wiring. The output-voltage difference between parallel units must be less than 0.2 V. Below 5% of the total rated current, current sharing may not be fully balanced. The catalogue describes the family as up to 4000 W (3+1), but the model-specific current formula and derating limits still apply. Cooling, Derating and Environment Temperature and load The specification lists -40 to +70°C subject to the derating curve. Horizontal mounting, 24/48 V branch: 100% load through +60°C, declining to 60% at +70°C. Input-voltage derating At 60 Hz, the input curve rises from 80% load at 90 VAC to 100% at 200 VAC, remaining at 100% through 264 VAC. Cooling / fan control Built-in cooling fan with ON/OFF control by internal NTC RT50 or 30% load minimum, as stated in the specification. The catalogue does not give a numeric ambient switching temperature for this sensor. Working humidity 20–90% RH, non-condensing. Storage -40 to +85°C and 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Altitude derating For this fan-cooled supply, reduce the permissible ambient temperature by 5°C per additional 1000 m above 2000 m (6500 ft), as specified in the catalogue note. Temperature and low-input-voltage limits apply together; the upper working-temperature figure does not mean full rated power is available at every input voltage. Dimensions, Terminals and Installation Overall dimensions 218 × 105 × 63.5 mm (L × W × H); case 977. Mechanical drawing tolerance ±0.5 mm. Mounting-hole labels Bottom: 4-M4 L=6; sides: 8-M4 L=4 (both sides). Use the complete drawing for thread engagement and hole positions; these labels are not accessory ordering codes. Hole-position references The drawing marks 152.4 mm spacing, a 32.8 mm end reference, and the 20.75/63.5 mm transverse references; side-view references include 38.3 and 12.5 mm. Follow the full drawing for each datum. AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG protective earth. DC output terminals 1–3 = +V; 4–6 = -V. Confirm polarity against this model’s terminal diagram. Terminal drawing dimensions The AC side marks 10 and 8.2 mm; the DC side marks 11 and 9.2 mm. These are drawing dimensions at their indicated locations, not a claim that every value is terminal pitch. Terminal projections AC-input side: 12 mm maximum; DC-output side: 18 mm maximum. Airflow and adjustment The mechanical drawing arrow points outward at the fan/input end. Keep the indicated airflow path unobstructed. The drawing identifies the LED and SVR1 output-voltage adjustment. Connector Mating Parts CN100 board connector HRS DF11-10DP-2DS or equivalent. Mating housing HRS DF11-10DS or equivalent, as listed for CN100. Mating terminal HRS DF11-**SC or equivalent is the printed terminal family; ** is not a confirmed orderable suffix. The catalogue identifies these mating parts but does not state that a cable, housing, terminals or mounting screws are included. Confirm the exact terminal suffix and wiring requirements before ordering; do not infer a complete accessory kit. Medical Safety, Leakage and Insulation Medical isolation Primary–secondary: 2 × MOPP; primary–earth: 1 × MOPP; secondary–earth: 1 × MOPP. Safety standards IEC 60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; EAC TP TC 004 approved. Design references include BS EN/EN60335-1 and BS EN/EN62368-1 (by request). Leakage current Earth leakage <360 µA at 264 VAC; touch leakage <100 µA at 264 VAC. Withstand voltage Input–output: 4.5 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance 100 MΩ for input–output, input–FG and output–FG, tested at 500 VDC / 25°C / 70% RH. The catalogue states suitability for BF applications with appropriate system consideration. The supply is a component; this does not certify the finished medical equipment or its patient connections. EMC and Integration Conditions Conducted / radiated emissions BS EN/EN55011 (CISPR11), Class B for each. Harmonic current / flicker BS EN/EN61000-3-2 Class A; BS EN/EN61000-3-3. Immunity standards BS EN/EN55035 and BS EN/EN60601-1-2. ESD BS EN/EN61000-4-2, Level 4: 15 kV air and 8 kV contact. Radiated RF / EFT-burst / conducted RF BS EN/EN61000-4-3, -4 and -6 respectively: Level 3. Surge BS EN/EN61000-4-5, Level 4: 2 kV line-to-line / 4 kV line-to-earth. Magnetic field BS EN/EN61000-4-8, Level 4. Dips / interruptions BS EN/EN61000-4-11: 100% dip for 1 period; 30% dip for 25 periods; 100% interruption for 250 periods. EMC testing uses the supply mounted on a 360 × 700 mm metal plate, 1 mm thick. This is a component-level test arrangement, not a statement that a plate is included. Reconfirm EMC compliance in the final equipment using the manufacturer’s component-power-supply guidance. Weight, Reliability and Catalogue Reference Catalogue unit weight 1530 g; catalogue packing reference per unit (1.53 kg in PACKING), not a measured net weight or shipment weight. MTBF 850.5 K hours minimum, Telcordia SR-332 (Bellcore); 105.8 K hours minimum, MIL-HDBK-217F at 25°C. These figures are reliability references, not a guaranteed service-life duration. Switching-frequency diagram PWM oscillator: 65 kHz. PFC oscillator: 90 kHz. Manufacturer warranty statement The manufacturer catalogue lists a five-year warranty, subject to the applicable manufacturer terms. Applicable datasheet MSP-1000-SPEC, 2025-01-23; PDF pages 17, 18, 19, 20, 21, 22.

    $528.34

  • MSP-1000-15

    MEAN WELL MSP-1000 series: Medical AC/DC Power Supply - MSP-1000-15

    MEAN WELL MSP-1000-15 is a single-output enclosed medical AC/DC power supply rated at 15 V, 64 A and 960 W. It supports a maximum 1000 W for 3 seconds; 960 W remains the continuous rating. Active current sharing is available under the specified parallel-operation limits. Select the load using the output rating and both ambient-temperature and input-voltage derating curves. Product Datasheet Download MEAN WELL MSP-1000 Datasheet (PDF) The MSP-1000 section is on PDF pages 17, 18, 19, 20, 21, 22. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model MSP-1000-15 Model code MSP identifies the series; 1000 is the power-class designation; 15 identifies the nominal DC output voltage. Use the actual rating below for this model. Rated DC output 15 V / 64 A / 960 W Current range 0–64 A Built-in voltage adjustment 14–17 V, using SVR1; respect the rated current and power limits. Ripple and noise 150 mVp-p maximum; 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±1.5%, including setup tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±1.5% Efficiency 92% typical under the stated measurement conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. Maximum output power is 1000 W for 3 seconds; do not treat this short-duration figure as the continuous output rating. Input and Startup Input range 90–264 VAC, 127–370 VDC; universal AC input with active PFC. The low-line curve limits usable output. Frequency / surge tolerance 47–63 Hz; withstands 300 VAC surge input for 5 seconds. Power factor PF >0.95 at 230 VAC and >0.98 at 115 VAC, typical at full load. Input current 8.5 A at 115 VAC / 5 A at 230 VAC, typical. Inrush current 20 A at 115 VAC / 40 A at 230 VAC, typical; active inrush-current limiting is shown in the block diagram. Setup / rise time 1000 ms / 50 ms at 230 VAC; 2000 ms / 50 ms at 115 VAC, at full load. Hold-up time 16 ms at 230 VAC and 16 ms at 115 VAC, typical at full load. Setup time is measured at the first cold start; repeated power cycling can increase it. Below 40 VAC, performance may degrade and the final-equipment manufacturer must reconfirm basic safety and essential performance; this note does not extend the rated input range. Protection Short circuit / overload Short-circuit protection is listed. Overload threshold: 105–135% of rated output power; constant-current limiting with automatic recovery after the fault is removed. Over-voltage protection 18.2–20.6 V; output shuts down and requires re-powering to recover. Over-temperature protection Output shuts down and automatically recovers after temperature decreases. Remote Control, Standby and DC-OK Remote ON/OFF CN100 pin 3 (RC+) to pin 4 (RC-): short = ON; open = OFF. Remote-off no-load consumption <0.75 W with RC+ and RC- open. Standby auxiliary output 5 V / 0.3 A; 4.75–5.25 V, ±5% tolerance, 50 mVp-p maximum ripple. AUX pin 2 is referenced to AUXG pin 1 and is not switched off by remote ON/OFF. DC-OK signal TTL output, referenced to CN100 GND pin 6 or 8: 3.3–5.6 V when the supply is ON; 0–1 V when OFF. Remote sense Up to 0.5 V load-wiring drop compensation. Connect +S pin 9 to load positive and -S pin 10 to load negative; twist the sense pair to minimize pickup. CN100 Control Connector Pin 1 — AUXG Auxiliary-output ground. Pin 2 — AUX Auxiliary voltage output, referenced to pin 1; 0.3 A maximum. Pins 3 / 4 — RC+ / RC- Remote-control input and return: short = ON; open = OFF. Pin 5 — CS Current-share signal; interconnect CS pins when using the supported parallel arrangement. Pins 6 / 8 — GND Connected to output -V; DC-OK signal return. Pin 7 — DC-OK TTL status signal, HIGH when the supply turns on; referenced to pin 8. Pins 9 / 10 — +S / -S Positive and negative remote sense; connect as shown in the model-specific wiring diagram. Parallel Operation Use short, large-diameter output wiring. Maximum total parallel current = rated current per unit × number of units × 0.9. Up to four units are shown; follow the complete manufacturer interconnection diagram, including CS, GND and sense wiring. The output-voltage difference between parallel units must be less than 0.2 V. Below 5% of the total rated current, current sharing may not be fully balanced. The catalogue describes the family as up to 4000 W (3+1), but the model-specific current formula and derating limits still apply. Cooling, Derating and Environment Temperature and load The specification lists -40 to +70°C subject to the derating curve. Horizontal mounting, 12/15 V branch: 100% load through +50°C, declining to 60% at +60°C; the plotted branch ends at +60°C. Input-voltage derating At 60 Hz, the input curve rises from 80% load at 90 VAC to 100% at 200 VAC, remaining at 100% through 264 VAC. Cooling / fan control Built-in cooling fan with ON/OFF control by internal NTC RT50 or 30% load minimum, as stated in the specification. The catalogue does not give a numeric ambient switching temperature for this sensor. Working humidity 20–90% RH, non-condensing. Storage -40 to +85°C and 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Altitude derating For this fan-cooled supply, reduce the permissible ambient temperature by 5°C per additional 1000 m above 2000 m (6500 ft), as specified in the catalogue note. Temperature and low-input-voltage limits apply together; the upper working-temperature figure does not mean full rated power is available at every input voltage. Dimensions, Terminals and Installation Overall dimensions 218 × 105 × 63.5 mm (L × W × H); case 977. Mechanical drawing tolerance ±0.5 mm. Mounting-hole labels Bottom: 4-M4 L=6; sides: 8-M4 L=4 (both sides). Use the complete drawing for thread engagement and hole positions; these labels are not accessory ordering codes. Hole-position references The drawing marks 152.4 mm spacing, a 32.8 mm end reference, and the 20.75/63.5 mm transverse references; side-view references include 38.3 and 12.5 mm. Follow the full drawing for each datum. AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG protective earth. DC output terminals 1–3 = +V; 4–6 = -V. Confirm polarity against this model’s terminal diagram. Terminal drawing dimensions The AC side marks 10 and 8.2 mm; the DC side marks 11 and 9.2 mm. These are drawing dimensions at their indicated locations, not a claim that every value is terminal pitch. Terminal projections AC-input side: 12 mm maximum; DC-output side: 18 mm maximum. Airflow and adjustment The mechanical drawing arrow points outward at the fan/input end. Keep the indicated airflow path unobstructed. The drawing identifies the LED and SVR1 output-voltage adjustment. Connector Mating Parts CN100 board connector HRS DF11-10DP-2DS or equivalent. Mating housing HRS DF11-10DS or equivalent, as listed for CN100. Mating terminal HRS DF11-**SC or equivalent is the printed terminal family; ** is not a confirmed orderable suffix. The catalogue identifies these mating parts but does not state that a cable, housing, terminals or mounting screws are included. Confirm the exact terminal suffix and wiring requirements before ordering; do not infer a complete accessory kit. Medical Safety, Leakage and Insulation Medical isolation Primary–secondary: 2 × MOPP; primary–earth: 1 × MOPP; secondary–earth: 1 × MOPP. Safety standards IEC 60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; EAC TP TC 004 approved. Design references include BS EN/EN60335-1 and BS EN/EN62368-1 (by request). Leakage current Earth leakage <360 µA at 264 VAC; touch leakage <100 µA at 264 VAC. Withstand voltage Input–output: 4.5 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance 100 MΩ for input–output, input–FG and output–FG, tested at 500 VDC / 25°C / 70% RH. The catalogue states suitability for BF applications with appropriate system consideration. The supply is a component; this does not certify the finished medical equipment or its patient connections. EMC and Integration Conditions Conducted / radiated emissions BS EN/EN55011 (CISPR11), Class B for each. Harmonic current / flicker BS EN/EN61000-3-2 Class A; BS EN/EN61000-3-3. Immunity standards BS EN/EN55035 and BS EN/EN60601-1-2. ESD BS EN/EN61000-4-2, Level 4: 15 kV air and 8 kV contact. Radiated RF / EFT-burst / conducted RF BS EN/EN61000-4-3, -4 and -6 respectively: Level 3. Surge BS EN/EN61000-4-5, Level 4: 2 kV line-to-line / 4 kV line-to-earth. Magnetic field BS EN/EN61000-4-8, Level 4. Dips / interruptions BS EN/EN61000-4-11: 100% dip for 1 period; 30% dip for 25 periods; 100% interruption for 250 periods. EMC testing uses the supply mounted on a 360 × 700 mm metal plate, 1 mm thick. This is a component-level test arrangement, not a statement that a plate is included. Reconfirm EMC compliance in the final equipment using the manufacturer’s component-power-supply guidance. Weight, Reliability and Catalogue Reference Catalogue unit weight 1530 g; catalogue packing reference per unit (1.53 kg in PACKING), not a measured net weight or shipment weight. MTBF 850.5 K hours minimum, Telcordia SR-332 (Bellcore); 105.8 K hours minimum, MIL-HDBK-217F at 25°C. These figures are reliability references, not a guaranteed service-life duration. Switching-frequency diagram PWM oscillator: 65 kHz. PFC oscillator: 90 kHz. Manufacturer warranty statement The manufacturer catalogue lists a five-year warranty, subject to the applicable manufacturer terms. Applicable datasheet MSP-1000-SPEC, 2025-01-23; PDF pages 17, 18, 19, 20, 21, 22.

    $528.34

  • MSP-1000-12

    MEAN WELL MSP-1000 series: Medical AC/DC Power Supply - MSP-1000-12

    MEAN WELL MSP-1000-12 is a single-output enclosed medical AC/DC power supply rated at 12 V, 80 A and 960 W. It supports a maximum 1000 W for 3 seconds; 960 W remains the continuous rating. Active current sharing is available under the specified parallel-operation limits. Select the load using the output rating and both ambient-temperature and input-voltage derating curves. Product Datasheet Download MEAN WELL MSP-1000 Datasheet (PDF) The MSP-1000 section is on PDF pages 17, 18, 19, 20, 21, 22. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model MSP-1000-12 Model code MSP identifies the series; 1000 is the power-class designation; 12 identifies the nominal DC output voltage. Use the actual rating below for this model. Rated DC output 12 V / 80 A / 960 W Current range 0–80 A Built-in voltage adjustment 11–14 V, using SVR1; respect the rated current and power limits. Ripple and noise 150 mVp-p maximum; 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±2.0%, including setup tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±2.0% Efficiency 91.5% typical under the stated measurement conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. Maximum output power is 1000 W for 3 seconds; do not treat this short-duration figure as the continuous output rating. Input and Startup Input range 90–264 VAC, 127–370 VDC; universal AC input with active PFC. The low-line curve limits usable output. Frequency / surge tolerance 47–63 Hz; withstands 300 VAC surge input for 5 seconds. Power factor PF >0.95 at 230 VAC and >0.98 at 115 VAC, typical at full load. Input current 8.5 A at 115 VAC / 5 A at 230 VAC, typical. Inrush current 20 A at 115 VAC / 40 A at 230 VAC, typical; active inrush-current limiting is shown in the block diagram. Setup / rise time 1000 ms / 50 ms at 230 VAC; 2000 ms / 50 ms at 115 VAC, at full load. Hold-up time 16 ms at 230 VAC and 16 ms at 115 VAC, typical at full load. Setup time is measured at the first cold start; repeated power cycling can increase it. Below 40 VAC, performance may degrade and the final-equipment manufacturer must reconfirm basic safety and essential performance; this note does not extend the rated input range. Protection Short circuit / overload Short-circuit protection is listed. Overload threshold: 105–135% of rated output power; constant-current limiting with automatic recovery after the fault is removed. Over-voltage protection 14.5–16.5 V; output shuts down and requires re-powering to recover. Over-temperature protection Output shuts down and automatically recovers after temperature decreases. Remote Control, Standby and DC-OK Remote ON/OFF CN100 pin 3 (RC+) to pin 4 (RC-): short = ON; open = OFF. Remote-off no-load consumption <0.75 W with RC+ and RC- open. Standby auxiliary output 5 V / 0.3 A; 4.75–5.25 V, ±5% tolerance, 50 mVp-p maximum ripple. AUX pin 2 is referenced to AUXG pin 1 and is not switched off by remote ON/OFF. DC-OK signal TTL output, referenced to CN100 GND pin 6 or 8: 3.3–5.6 V when the supply is ON; 0–1 V when OFF. Remote sense Up to 0.5 V load-wiring drop compensation. Connect +S pin 9 to load positive and -S pin 10 to load negative; twist the sense pair to minimize pickup. CN100 Control Connector Pin 1 — AUXG Auxiliary-output ground. Pin 2 — AUX Auxiliary voltage output, referenced to pin 1; 0.3 A maximum. Pins 3 / 4 — RC+ / RC- Remote-control input and return: short = ON; open = OFF. Pin 5 — CS Current-share signal; interconnect CS pins when using the supported parallel arrangement. Pins 6 / 8 — GND Connected to output -V; DC-OK signal return. Pin 7 — DC-OK TTL status signal, HIGH when the supply turns on; referenced to pin 8. Pins 9 / 10 — +S / -S Positive and negative remote sense; connect as shown in the model-specific wiring diagram. Parallel Operation Use short, large-diameter output wiring. Maximum total parallel current = rated current per unit × number of units × 0.9. Up to four units are shown; follow the complete manufacturer interconnection diagram, including CS, GND and sense wiring. The output-voltage difference between parallel units must be less than 0.2 V. Below 5% of the total rated current, current sharing may not be fully balanced. The catalogue describes the family as up to 4000 W (3+1), but the model-specific current formula and derating limits still apply. Cooling, Derating and Environment Temperature and load The specification lists -40 to +70°C subject to the derating curve. Horizontal mounting, 12/15 V branch: 100% load through +50°C, declining to 60% at +60°C; the plotted branch ends at +60°C. Input-voltage derating At 60 Hz, the input curve rises from 80% load at 90 VAC to 100% at 200 VAC, remaining at 100% through 264 VAC. Cooling / fan control Built-in cooling fan with ON/OFF control by internal NTC RT50 or 30% load minimum, as stated in the specification. The catalogue does not give a numeric ambient switching temperature for this sensor. Working humidity 20–90% RH, non-condensing. Storage -40 to +85°C and 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Altitude derating For this fan-cooled supply, reduce the permissible ambient temperature by 5°C per additional 1000 m above 2000 m (6500 ft), as specified in the catalogue note. Temperature and low-input-voltage limits apply together; the upper working-temperature figure does not mean full rated power is available at every input voltage. Dimensions, Terminals and Installation Overall dimensions 218 × 105 × 63.5 mm (L × W × H); case 977. Mechanical drawing tolerance ±0.5 mm. Mounting-hole labels Bottom: 4-M4 L=6; sides: 8-M4 L=4 (both sides). Use the complete drawing for thread engagement and hole positions; these labels are not accessory ordering codes. Hole-position references The drawing marks 152.4 mm spacing, a 32.8 mm end reference, and the 20.75/63.5 mm transverse references; side-view references include 38.3 and 12.5 mm. Follow the full drawing for each datum. AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG protective earth. DC output terminals 1–3 = +V; 4–6 = -V. Confirm polarity against this model’s terminal diagram. Terminal drawing dimensions The AC side marks 10 and 8.2 mm; the DC side marks 11 and 9.2 mm. These are drawing dimensions at their indicated locations, not a claim that every value is terminal pitch. Terminal projections AC-input side: 12 mm maximum; DC-output side: 18 mm maximum. Airflow and adjustment The mechanical drawing arrow points outward at the fan/input end. Keep the indicated airflow path unobstructed. The drawing identifies the LED and SVR1 output-voltage adjustment. Connector Mating Parts CN100 board connector HRS DF11-10DP-2DS or equivalent. Mating housing HRS DF11-10DS or equivalent, as listed for CN100. Mating terminal HRS DF11-**SC or equivalent is the printed terminal family; ** is not a confirmed orderable suffix. The catalogue identifies these mating parts but does not state that a cable, housing, terminals or mounting screws are included. Confirm the exact terminal suffix and wiring requirements before ordering; do not infer a complete accessory kit. Medical Safety, Leakage and Insulation Medical isolation Primary–secondary: 2 × MOPP; primary–earth: 1 × MOPP; secondary–earth: 1 × MOPP. Safety standards IEC 60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; EAC TP TC 004 approved. Design references include BS EN/EN60335-1 and BS EN/EN62368-1 (by request). Leakage current Earth leakage <360 µA at 264 VAC; touch leakage <100 µA at 264 VAC. Withstand voltage Input–output: 4.5 kVAC; input–FG: 2 kVAC; output–FG: 1.5 kVAC. Insulation resistance 100 MΩ for input–output, input–FG and output–FG, tested at 500 VDC / 25°C / 70% RH. The catalogue states suitability for BF applications with appropriate system consideration. The supply is a component; this does not certify the finished medical equipment or its patient connections. EMC and Integration Conditions Conducted / radiated emissions BS EN/EN55011 (CISPR11), Class B for each. Harmonic current / flicker BS EN/EN61000-3-2 Class A; BS EN/EN61000-3-3. Immunity standards BS EN/EN55035 and BS EN/EN60601-1-2. ESD BS EN/EN61000-4-2, Level 4: 15 kV air and 8 kV contact. Radiated RF / EFT-burst / conducted RF BS EN/EN61000-4-3, -4 and -6 respectively: Level 3. Surge BS EN/EN61000-4-5, Level 4: 2 kV line-to-line / 4 kV line-to-earth. Magnetic field BS EN/EN61000-4-8, Level 4. Dips / interruptions BS EN/EN61000-4-11: 100% dip for 1 period; 30% dip for 25 periods; 100% interruption for 250 periods. EMC testing uses the supply mounted on a 360 × 700 mm metal plate, 1 mm thick. This is a component-level test arrangement, not a statement that a plate is included. Reconfirm EMC compliance in the final equipment using the manufacturer’s component-power-supply guidance. Weight, Reliability and Catalogue Reference Catalogue unit weight 1530 g; catalogue packing reference per unit (1.53 kg in PACKING), not a measured net weight or shipment weight. MTBF 850.5 K hours minimum, Telcordia SR-332 (Bellcore); 105.8 K hours minimum, MIL-HDBK-217F at 25°C. These figures are reliability references, not a guaranteed service-life duration. Switching-frequency diagram PWM oscillator: 65 kHz. PFC oscillator: 90 kHz. Manufacturer warranty statement The manufacturer catalogue lists a five-year warranty, subject to the applicable manufacturer terms. Applicable datasheet MSP-1000-SPEC, 2025-01-23; PDF pages 17, 18, 19, 20, 21, 22.

    $543.13

  • MSP-600-48

    MEAN WELL MSP-600 series: Medical AC/DC Power Supply - MSP-600-48

    MEAN WELL MSP-600-48 is a single-output enclosed medical AC/DC power supply rated at 48 V, 13 A and 624 W. Active current sharing is available under the specified parallel-operation limits. Select the load using the output rating and both ambient-temperature and input-voltage derating curves. Product Datasheet Download MEAN WELL MSP-600 Datasheet (PDF) The MSP-600 section is on PDF pages 13, 14, 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model MSP-600-48 Model code MSP identifies the series; 600 is the power-class designation; 48 identifies the nominal DC output voltage. Use the actual rating below for this model. Rated DC output 48 V / 13 A / 624 W Current range 0–13 A Built-in voltage adjustment 40.8–55.2 V, using SVR1; respect the rated current and power limits. Ripple and noise 240 mVp-p maximum; 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±1.0%, including setup tolerance, line regulation and load regulation. Line / load regulation ±0.2% / ±0.5% Efficiency 89% typical under the stated measurement conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. Input and Startup Input range 85–264 VAC, 120–370 VDC; universal AC input with active PFC. The low-line curve limits usable output. Frequency / surge tolerance 47–63 Hz; withstands 300 VAC surge input for 5 seconds. Power factor PF >0.93 at 230 VAC and >0.99 at 115 VAC, typical at full load. Input current 8.5 A at 115 VAC / 5 A at 230 VAC, typical. Inrush current 35 A at 115 VAC / 80 A at 230 VAC, typical; active inrush-current limiting is shown in the block diagram. Setup / rise time 1000 ms / 50 ms at 230 VAC; 2500 ms / 50 ms at 115 VAC, at full load. Hold-up time 16 ms at 230 VAC and 16 ms at 115 VAC, typical at full load. Setup time is measured at the first cold start; repeated power cycling can increase it. Below 40 VAC, performance may degrade and the final-equipment manufacturer must reconfirm basic safety and essential performance; this note does not extend the rated input range. Protection Short circuit / overload Short-circuit protection is listed. Overload threshold: 105–135% of rated output power; constant-current limiting with automatic recovery after the fault is removed. Over-voltage protection 57.6–67.2 V; output shuts down and requires re-powering to recover. Over-temperature protection Output shuts down and automatically recovers after temperature decreases. Remote Control, Standby and DC-OK Remote ON/OFF CN100 pin 3 (RC+) to pin 4 (RC-): short or 0–0.8 V = OFF; open or 4–10 V = ON. Remote-off no-load consumption <0.8 W with RC+ and RC- shorted or at 0–0.8 V. Standby auxiliary output 5 V / 0.3 A; 4.75–5.25 V, ±5% tolerance, 50 mVp-p maximum ripple. AUX pin 2 is referenced to AUXG pin 1 and is not switched off by remote ON/OFF. DC-OK signal TTL output, referenced to CN100 GND pin 6 or 8: 3.3–5.6 V when the supply is ON; 0–1 V when OFF. Remote sense Up to 0.5 V load-wiring drop compensation. Connect +S pin 9 to load positive and -S pin 10 to load negative; twist the sense pair to minimize pickup. CN100 Control Connector Pin 1 — AUXG Auxiliary-output ground. This signal return is isolated from the +V/-V output terminals. Pin 2 — AUX Auxiliary voltage output, referenced to pin 1; 0.3 A maximum. Pins 3 / 4 — RC+ / RC- Remote-control input and return: short = OFF; open = ON. Pin 5 — CS Current-share signal; interconnect CS pins when using the supported parallel arrangement. Pins 6 / 8 — GND Connected to output -V; DC-OK signal return. Pin 7 — DC-OK TTL status signal, HIGH when the supply turns on; referenced to pin 8. Pins 9 / 10 — +S / -S Positive and negative remote sense; connect as shown in the model-specific wiring diagram. Parallel Operation Use short, large-diameter output wiring. Maximum total parallel current = rated current per unit × number of units × 0.9. Up to four units are shown; follow the complete manufacturer interconnection diagram, including CS, GND and sense wiring. For this MSP-600 voltage version, the output-voltage difference between parallel units must be less than 2%. The diagram interconnects +S, -S, CS and GND. For more than four units, consult the manufacturer. Below 2% of rated load, only one master unit may operate; other slave units may enter standby with their output LED and relay off. This minimum-load condition is part of the parallel-operation instructions. Cooling, Derating and Environment Temperature and load The specification lists -40 to +70°C subject to the derating curve. Horizontal mounting: the plotted load remains at 100% from -40°C through +50°C, then declines to 50% at +70°C. Input-voltage derating At 60 Hz, the input curve rises from 80% load at 85 VAC to 100% at 100 VAC, remaining at 100% through 264 VAC. Cooling / fan control Built-in cooling fan with ON/OFF control; fan ON at 35±15% load or when internal sensor RTH2 reaches at least 50°C. The sensor temperature is not an ambient-temperature rating. Working humidity 20–90% RH, non-condensing. Storage -40 to +85°C and 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Altitude derating For this fan-cooled supply, reduce the permissible ambient temperature by 5°C per additional 1000 m above 2000 m (6500 ft), as specified in the catalogue note. Temperature and low-input-voltage limits apply together; the upper working-temperature figure does not mean full rated power is available at every input voltage. Dimensions, Terminals and Installation Overall dimensions 218 × 105 × 63.5 mm (L × W × H); case 977A. Mechanical drawing tolerance ±1 mm. Mounting-hole labels Bottom: 4-M4 L=6; sides: 8-M4 L=4 (both sides). Use the complete drawing for thread engagement and hole positions; these labels are not accessory ordering codes. Hole-position references The drawing marks 152.4 mm spacing, a 32.8 mm end reference, and the 20.75/63.5 mm transverse references; side-view references include 38.3 and 12.5 mm. Follow the full drawing for each datum. AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG protective earth. DC output terminals 1–3 = -V; 4–6 = +V. Confirm polarity against this model’s terminal diagram. Terminal drawing dimensions The AC side marks 10 and 8.2 mm; the DC side marks 11 and 9.2 mm. These are drawing dimensions at their indicated locations, not a claim that every value is terminal pitch. Terminal projections AC-input side: 12 mm maximum; DC-output side: 18 mm maximum. Airflow and adjustment The mechanical drawing arrow points from the fan/input end toward the DC-output end. Keep the indicated airflow path unobstructed. The drawing identifies the LED and SVR1 output-voltage adjustment. Connector Mating Parts CN100 board connector HRS DF11-10DP-2DS or equivalent. Mating housing HRS DF11-10DS or equivalent, as listed for CN100. Mating terminal HRS DF11-**SC or equivalent is the printed terminal family; ** is not a confirmed orderable suffix. The catalogue identifies these mating parts but does not state that a cable, housing, terminals or mounting screws are included. Confirm the exact terminal suffix and wiring requirements before ordering; do not infer a complete accessory kit. Medical Safety, Leakage and Insulation Medical isolation Primary–secondary: 2 × MOOP; primary–earth: 1 × MOOP; secondary–earth: 1 × MOOP. Safety standards IEC 60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; EAC TP TC 004 approved. Design references include BS EN/EN60335-1 and BS EN/EN62368-1 (by request). Leakage current Earth leakage <300 µA at 264 VAC; touch leakage <100 µA at 264 VAC. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ for input–output, input–FG and output–FG, tested at 500 VDC / 25°C / 70% RH. The catalogue specifies MOOP-level isolation for this family; do not substitute a MOPP or BF claim. Finished-equipment safety must be evaluated for the actual installation. EMC and Integration Conditions Emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN60601-1-2; EAC TP TC020. EMC testing uses the supply mounted on a 360 × 360 mm metal plate, 1 mm thick. This is a component-level test arrangement, not a statement that a plate is included. Reconfirm EMC compliance in the final equipment using the manufacturer’s component-power-supply guidance. Weight, Reliability and Catalogue Reference Catalogue unit weight 1570 g; catalogue packing reference per unit (1.57 kg in PACKING), not a measured net weight or shipment weight. MTBF 138.7 K hours minimum, MIL-HDBK-217F at 25°C. These figures are reliability references, not a guaranteed service-life duration. Switching-frequency diagram PWM oscillator: 70 kHz. Manufacturer warranty statement The manufacturer catalogue lists a five-year warranty, subject to the applicable manufacturer terms. Applicable datasheet MSP-600-SPEC, 2024-10-30; PDF pages 13, 14, 15, 16.

    $435.19

  • MSP-600-36

    MEAN WELL MSP-600 series: Medical AC/DC Power Supply - MSP-600-36

    MEAN WELL MSP-600-36 is a single-output enclosed medical AC/DC power supply rated at 36 V, 17.5 A and 630 W. Active current sharing is available under the specified parallel-operation limits. Select the load using the output rating and both ambient-temperature and input-voltage derating curves. Product Datasheet Download MEAN WELL MSP-600 Datasheet (PDF) The MSP-600 section is on PDF pages 13, 14, 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model MSP-600-36 Model code MSP identifies the series; 600 is the power-class designation; 36 identifies the nominal DC output voltage. Use the actual rating below for this model. Rated DC output 36 V / 17.5 A / 630 W Current range 0–17.5 A Built-in voltage adjustment 28.8–39.6 V, using SVR1; respect the rated current and power limits. Ripple and noise 200 mVp-p maximum; 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±1.0%, including setup tolerance, line regulation and load regulation. Line / load regulation ±0.2% / ±0.5% Efficiency 89% typical under the stated measurement conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. Input and Startup Input range 85–264 VAC, 120–370 VDC; universal AC input with active PFC. The low-line curve limits usable output. Frequency / surge tolerance 47–63 Hz; withstands 300 VAC surge input for 5 seconds. Power factor PF >0.93 at 230 VAC and >0.99 at 115 VAC, typical at full load. Input current 8.5 A at 115 VAC / 5 A at 230 VAC, typical. Inrush current 35 A at 115 VAC / 80 A at 230 VAC, typical; active inrush-current limiting is shown in the block diagram. Setup / rise time 1000 ms / 50 ms at 230 VAC; 2500 ms / 50 ms at 115 VAC, at full load. Hold-up time 16 ms at 230 VAC and 16 ms at 115 VAC, typical at full load. Setup time is measured at the first cold start; repeated power cycling can increase it. Below 40 VAC, performance may degrade and the final-equipment manufacturer must reconfirm basic safety and essential performance; this note does not extend the rated input range. Protection Short circuit / overload Short-circuit protection is listed. Overload threshold: 105–135% of rated output power; constant-current limiting with automatic recovery after the fault is removed. Over-voltage protection 41.4–48.6 V; output shuts down and requires re-powering to recover. Over-temperature protection Output shuts down and automatically recovers after temperature decreases. Remote Control, Standby and DC-OK Remote ON/OFF CN100 pin 3 (RC+) to pin 4 (RC-): short or 0–0.8 V = OFF; open or 4–10 V = ON. Remote-off no-load consumption <0.8 W with RC+ and RC- shorted or at 0–0.8 V. Standby auxiliary output 5 V / 0.3 A; 4.75–5.25 V, ±5% tolerance, 50 mVp-p maximum ripple. AUX pin 2 is referenced to AUXG pin 1 and is not switched off by remote ON/OFF. DC-OK signal TTL output, referenced to CN100 GND pin 6 or 8: 3.3–5.6 V when the supply is ON; 0–1 V when OFF. Remote sense Up to 0.5 V load-wiring drop compensation. Connect +S pin 9 to load positive and -S pin 10 to load negative; twist the sense pair to minimize pickup. CN100 Control Connector Pin 1 — AUXG Auxiliary-output ground. This signal return is isolated from the +V/-V output terminals. Pin 2 — AUX Auxiliary voltage output, referenced to pin 1; 0.3 A maximum. Pins 3 / 4 — RC+ / RC- Remote-control input and return: short = OFF; open = ON. Pin 5 — CS Current-share signal; interconnect CS pins when using the supported parallel arrangement. Pins 6 / 8 — GND Connected to output -V; DC-OK signal return. Pin 7 — DC-OK TTL status signal, HIGH when the supply turns on; referenced to pin 8. Pins 9 / 10 — +S / -S Positive and negative remote sense; connect as shown in the model-specific wiring diagram. Parallel Operation Use short, large-diameter output wiring. Maximum total parallel current = rated current per unit × number of units × 0.9. Up to four units are shown; follow the complete manufacturer interconnection diagram, including CS, GND and sense wiring. For this MSP-600 voltage version, the output-voltage difference between parallel units must be less than 2%. The diagram interconnects +S, -S, CS and GND. For more than four units, consult the manufacturer. Below 2% of rated load, only one master unit may operate; other slave units may enter standby with their output LED and relay off. This minimum-load condition is part of the parallel-operation instructions. Cooling, Derating and Environment Temperature and load The specification lists -40 to +70°C subject to the derating curve. Horizontal mounting: the plotted load remains at 100% from -40°C through +50°C, then declines to 50% at +70°C. Input-voltage derating At 60 Hz, the input curve rises from 80% load at 85 VAC to 100% at 100 VAC, remaining at 100% through 264 VAC. Cooling / fan control Built-in cooling fan with ON/OFF control; fan ON at 35±15% load or when internal sensor RTH2 reaches at least 50°C. The sensor temperature is not an ambient-temperature rating. Working humidity 20–90% RH, non-condensing. Storage -40 to +85°C and 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Altitude derating For this fan-cooled supply, reduce the permissible ambient temperature by 5°C per additional 1000 m above 2000 m (6500 ft), as specified in the catalogue note. Temperature and low-input-voltage limits apply together; the upper working-temperature figure does not mean full rated power is available at every input voltage. Dimensions, Terminals and Installation Overall dimensions 218 × 105 × 63.5 mm (L × W × H); case 977A. Mechanical drawing tolerance ±1 mm. Mounting-hole labels Bottom: 4-M4 L=6; sides: 8-M4 L=4 (both sides). Use the complete drawing for thread engagement and hole positions; these labels are not accessory ordering codes. Hole-position references The drawing marks 152.4 mm spacing, a 32.8 mm end reference, and the 20.75/63.5 mm transverse references; side-view references include 38.3 and 12.5 mm. Follow the full drawing for each datum. AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG protective earth. DC output terminals 1–3 = -V; 4–6 = +V. Confirm polarity against this model’s terminal diagram. Terminal drawing dimensions The AC side marks 10 and 8.2 mm; the DC side marks 11 and 9.2 mm. These are drawing dimensions at their indicated locations, not a claim that every value is terminal pitch. Terminal projections AC-input side: 12 mm maximum; DC-output side: 18 mm maximum. Airflow and adjustment The mechanical drawing arrow points from the fan/input end toward the DC-output end. Keep the indicated airflow path unobstructed. The drawing identifies the LED and SVR1 output-voltage adjustment. Connector Mating Parts CN100 board connector HRS DF11-10DP-2DS or equivalent. Mating housing HRS DF11-10DS or equivalent, as listed for CN100. Mating terminal HRS DF11-**SC or equivalent is the printed terminal family; ** is not a confirmed orderable suffix. The catalogue identifies these mating parts but does not state that a cable, housing, terminals or mounting screws are included. Confirm the exact terminal suffix and wiring requirements before ordering; do not infer a complete accessory kit. Medical Safety, Leakage and Insulation Medical isolation Primary–secondary: 2 × MOOP; primary–earth: 1 × MOOP; secondary–earth: 1 × MOOP. Safety standards IEC 60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; EAC TP TC 004 approved. Design references include BS EN/EN60335-1 and BS EN/EN62368-1 (by request). Leakage current Earth leakage <300 µA at 264 VAC; touch leakage <100 µA at 264 VAC. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ for input–output, input–FG and output–FG, tested at 500 VDC / 25°C / 70% RH. The catalogue specifies MOOP-level isolation for this family; do not substitute a MOPP or BF claim. Finished-equipment safety must be evaluated for the actual installation. EMC and Integration Conditions Emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN60601-1-2; EAC TP TC020. EMC testing uses the supply mounted on a 360 × 360 mm metal plate, 1 mm thick. This is a component-level test arrangement, not a statement that a plate is included. Reconfirm EMC compliance in the final equipment using the manufacturer’s component-power-supply guidance. Weight, Reliability and Catalogue Reference Catalogue unit weight 1570 g; catalogue packing reference per unit (1.57 kg in PACKING), not a measured net weight or shipment weight. MTBF 138.7 K hours minimum, MIL-HDBK-217F at 25°C. These figures are reliability references, not a guaranteed service-life duration. Switching-frequency diagram PWM oscillator: 70 kHz. Manufacturer warranty statement The manufacturer catalogue lists a five-year warranty, subject to the applicable manufacturer terms. Applicable datasheet MSP-600-SPEC, 2024-10-30; PDF pages 13, 14, 15, 16.

    $435.19

  • MSP-600-24

    MEAN WELL MSP-600 series: Medical AC/DC Power Supply - MSP-600-24

    MEAN WELL MSP-600-24 is a single-output enclosed medical AC/DC power supply rated at 24 V, 27 A and 648 W. Active current sharing is available under the specified parallel-operation limits. Select the load using the output rating and both ambient-temperature and input-voltage derating curves. Product Datasheet Download MEAN WELL MSP-600 Datasheet (PDF) The MSP-600 section is on PDF pages 13, 14, 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model MSP-600-24 Model code MSP identifies the series; 600 is the power-class designation; 24 identifies the nominal DC output voltage. Use the actual rating below for this model. Rated DC output 24 V / 27 A / 648 W Current range 0–27 A Built-in voltage adjustment 21.6–28.8 V, using SVR1; respect the rated current and power limits. Ripple and noise 150 mVp-p maximum; 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±1.0%, including setup tolerance, line regulation and load regulation. Line / load regulation ±0.2% / ±0.5% Efficiency 88% typical under the stated measurement conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. Input and Startup Input range 85–264 VAC, 120–370 VDC; universal AC input with active PFC. The low-line curve limits usable output. Frequency / surge tolerance 47–63 Hz; withstands 300 VAC surge input for 5 seconds. Power factor PF >0.93 at 230 VAC and >0.99 at 115 VAC, typical at full load. Input current 8.5 A at 115 VAC / 5 A at 230 VAC, typical. Inrush current 35 A at 115 VAC / 80 A at 230 VAC, typical; active inrush-current limiting is shown in the block diagram. Setup / rise time 1000 ms / 50 ms at 230 VAC; 2500 ms / 50 ms at 115 VAC, at full load. Hold-up time 16 ms at 230 VAC and 16 ms at 115 VAC, typical at full load. Setup time is measured at the first cold start; repeated power cycling can increase it. Below 40 VAC, performance may degrade and the final-equipment manufacturer must reconfirm basic safety and essential performance; this note does not extend the rated input range. Protection Short circuit / overload Short-circuit protection is listed. Overload threshold: 105–135% of rated output power; constant-current limiting with automatic recovery after the fault is removed. Over-voltage protection 30–34.8 V; output shuts down and requires re-powering to recover. Over-temperature protection Output shuts down and automatically recovers after temperature decreases. Remote Control, Standby and DC-OK Remote ON/OFF CN100 pin 3 (RC+) to pin 4 (RC-): short or 0–0.8 V = OFF; open or 4–10 V = ON. Remote-off no-load consumption <0.8 W with RC+ and RC- shorted or at 0–0.8 V. Standby auxiliary output 5 V / 0.3 A; 4.75–5.25 V, ±5% tolerance, 50 mVp-p maximum ripple. AUX pin 2 is referenced to AUXG pin 1 and is not switched off by remote ON/OFF. DC-OK signal TTL output, referenced to CN100 GND pin 6 or 8: 3.3–5.6 V when the supply is ON; 0–1 V when OFF. Remote sense Up to 0.5 V load-wiring drop compensation. Connect +S pin 9 to load positive and -S pin 10 to load negative; twist the sense pair to minimize pickup. CN100 Control Connector Pin 1 — AUXG Auxiliary-output ground. This signal return is isolated from the +V/-V output terminals. Pin 2 — AUX Auxiliary voltage output, referenced to pin 1; 0.3 A maximum. Pins 3 / 4 — RC+ / RC- Remote-control input and return: short = OFF; open = ON. Pin 5 — CS Current-share signal; interconnect CS pins when using the supported parallel arrangement. Pins 6 / 8 — GND Connected to output -V; DC-OK signal return. Pin 7 — DC-OK TTL status signal, HIGH when the supply turns on; referenced to pin 8. Pins 9 / 10 — +S / -S Positive and negative remote sense; connect as shown in the model-specific wiring diagram. Parallel Operation Use short, large-diameter output wiring. Maximum total parallel current = rated current per unit × number of units × 0.9. Up to four units are shown; follow the complete manufacturer interconnection diagram, including CS, GND and sense wiring. For this MSP-600 voltage version, the output-voltage difference between parallel units must be less than 2%. The diagram interconnects +S, -S, CS and GND. For more than four units, consult the manufacturer. Below 2% of rated load, only one master unit may operate; other slave units may enter standby with their output LED and relay off. This minimum-load condition is part of the parallel-operation instructions. Cooling, Derating and Environment Temperature and load The specification lists -40 to +70°C subject to the derating curve. Horizontal mounting: the plotted load remains at 100% from -40°C through +50°C, then declines to 50% at +70°C. Input-voltage derating At 60 Hz, the input curve rises from 80% load at 85 VAC to 100% at 100 VAC, remaining at 100% through 264 VAC. Cooling / fan control Built-in cooling fan with ON/OFF control; fan ON at 35±15% load or when internal sensor RTH2 reaches at least 50°C. The sensor temperature is not an ambient-temperature rating. Working humidity 20–90% RH, non-condensing. Storage -40 to +85°C and 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Altitude derating For this fan-cooled supply, reduce the permissible ambient temperature by 5°C per additional 1000 m above 2000 m (6500 ft), as specified in the catalogue note. Temperature and low-input-voltage limits apply together; the upper working-temperature figure does not mean full rated power is available at every input voltage. Dimensions, Terminals and Installation Overall dimensions 218 × 105 × 63.5 mm (L × W × H); case 977A. Mechanical drawing tolerance ±1 mm. Mounting-hole labels Bottom: 4-M4 L=6; sides: 8-M4 L=4 (both sides). Use the complete drawing for thread engagement and hole positions; these labels are not accessory ordering codes. Hole-position references The drawing marks 152.4 mm spacing, a 32.8 mm end reference, and the 20.75/63.5 mm transverse references; side-view references include 38.3 and 12.5 mm. Follow the full drawing for each datum. AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG protective earth. DC output terminals 1–3 = -V; 4–6 = +V. Confirm polarity against this model’s terminal diagram. Terminal drawing dimensions The AC side marks 10 and 8.2 mm; the DC side marks 11 and 9.2 mm. These are drawing dimensions at their indicated locations, not a claim that every value is terminal pitch. Terminal projections AC-input side: 12 mm maximum; DC-output side: 18 mm maximum. Airflow and adjustment The mechanical drawing arrow points from the fan/input end toward the DC-output end. Keep the indicated airflow path unobstructed. The drawing identifies the LED and SVR1 output-voltage adjustment. Connector Mating Parts CN100 board connector HRS DF11-10DP-2DS or equivalent. Mating housing HRS DF11-10DS or equivalent, as listed for CN100. Mating terminal HRS DF11-**SC or equivalent is the printed terminal family; ** is not a confirmed orderable suffix. The catalogue identifies these mating parts but does not state that a cable, housing, terminals or mounting screws are included. Confirm the exact terminal suffix and wiring requirements before ordering; do not infer a complete accessory kit. Medical Safety, Leakage and Insulation Medical isolation Primary–secondary: 2 × MOOP; primary–earth: 1 × MOOP; secondary–earth: 1 × MOOP. Safety standards IEC 60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; EAC TP TC 004 approved. Design references include BS EN/EN60335-1 and BS EN/EN62368-1 (by request). Leakage current Earth leakage <300 µA at 264 VAC; touch leakage <100 µA at 264 VAC. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ for input–output, input–FG and output–FG, tested at 500 VDC / 25°C / 70% RH. The catalogue specifies MOOP-level isolation for this family; do not substitute a MOPP or BF claim. Finished-equipment safety must be evaluated for the actual installation. EMC and Integration Conditions Emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN60601-1-2; EAC TP TC020. EMC testing uses the supply mounted on a 360 × 360 mm metal plate, 1 mm thick. This is a component-level test arrangement, not a statement that a plate is included. Reconfirm EMC compliance in the final equipment using the manufacturer’s component-power-supply guidance. Weight, Reliability and Catalogue Reference Catalogue unit weight 1570 g; catalogue packing reference per unit (1.57 kg in PACKING), not a measured net weight or shipment weight. MTBF 138.7 K hours minimum, MIL-HDBK-217F at 25°C. These figures are reliability references, not a guaranteed service-life duration. Switching-frequency diagram PWM oscillator: 70 kHz. Manufacturer warranty statement The manufacturer catalogue lists a five-year warranty, subject to the applicable manufacturer terms. Applicable datasheet MSP-600-SPEC, 2024-10-30; PDF pages 13, 14, 15, 16.

    $435.19

  • MSP-600-15

    MEAN WELL MSP-600 series: Medical AC/DC Power Supply - MSP-600-15

    MEAN WELL MSP-600-15 is a single-output enclosed medical AC/DC power supply rated at 15 V, 43 A and 645 W. Select the load using the output rating and both ambient-temperature and input-voltage derating curves. Product Datasheet Download MEAN WELL MSP-600 Datasheet (PDF) The MSP-600 section is on PDF pages 13, 14, 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model MSP-600-15 Model code MSP identifies the series; 600 is the power-class designation; 15 identifies the nominal DC output voltage. Use the actual rating below for this model. Rated DC output 15 V / 43 A / 645 W Current range 0–43 A Built-in voltage adjustment 13.5–18 V, using SVR1; respect the rated current and power limits. Ripple and noise 150 mVp-p maximum; 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±1.0%, including setup tolerance, line regulation and load regulation. Line / load regulation ±0.3% / ±0.5% Efficiency 88% typical under the stated measurement conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. Input and Startup Input range 85–264 VAC, 120–370 VDC; universal AC input with active PFC. The low-line curve limits usable output. Frequency / surge tolerance 47–63 Hz; withstands 300 VAC surge input for 5 seconds. Power factor PF >0.93 at 230 VAC and >0.99 at 115 VAC, typical at full load. Input current 8.5 A at 115 VAC / 5 A at 230 VAC, typical. Inrush current 35 A at 115 VAC / 80 A at 230 VAC, typical; active inrush-current limiting is shown in the block diagram. Setup / rise time 1000 ms / 50 ms at 230 VAC; 2500 ms / 50 ms at 115 VAC, at full load. Hold-up time 16 ms at 230 VAC and 16 ms at 115 VAC, typical at full load. Setup time is measured at the first cold start; repeated power cycling can increase it. Below 40 VAC, performance may degrade and the final-equipment manufacturer must reconfirm basic safety and essential performance; this note does not extend the rated input range. Protection Short circuit / overload Short-circuit protection is listed. Overload threshold: 105–135% of rated output power; constant-current limiting with automatic recovery after the fault is removed. Over-voltage protection 18.8–21.8 V; output shuts down and requires re-powering to recover. Over-temperature protection Output shuts down and automatically recovers after temperature decreases. Remote Control, Standby and DC-OK Remote ON/OFF CN100 pin 3 (RC+) to pin 4 (RC-): short or 0–0.8 V = OFF; open or 4–10 V = ON. Remote-off no-load consumption <0.8 W with RC+ and RC- shorted or at 0–0.8 V. Standby auxiliary output 5 V / 0.3 A; 4.75–5.25 V, ±5% tolerance, 50 mVp-p maximum ripple. AUX pin 2 is referenced to AUXG pin 1 and is not switched off by remote ON/OFF. DC-OK signal TTL output, referenced to CN100 GND pin 6 or 8: 3.3–5.6 V when the supply is ON; 0–1 V when OFF. Remote sense Up to 0.5 V load-wiring drop compensation. Connect +S pin 9 to load positive and -S pin 10 to load negative; twist the sense pair to minimize pickup. CN100 Control Connector Pin 1 — AUXG Auxiliary-output ground. This signal return is isolated from the +V/-V output terminals. Pin 2 — AUX Auxiliary voltage output, referenced to pin 1; 0.3 A maximum. Pins 3 / 4 — RC+ / RC- Remote-control input and return: short = OFF; open = ON. Pin 5 — CS CS is identified in the common connector table; active current sharing is specified only for MSP-600-24, -36 and -48, not this voltage version. Pins 6 / 8 — GND Connected to output -V; DC-OK signal return. Pin 7 — DC-OK TTL status signal, HIGH when the supply turns on; referenced to pin 8. Pins 9 / 10 — +S / -S Positive and negative remote sense; connect as shown in the model-specific wiring diagram. Parallel-operation Boundary The active current-sharing arrangement in this catalogue is limited to the 24 V, 36 V and 48 V MSP-600 versions. Do not apply that function to this model merely because the common connector drawing labels pin 5 as CS. Cooling, Derating and Environment Temperature and load The specification lists -40 to +70°C subject to the derating curve. Horizontal mounting: the plotted load remains at 100% from -40°C through +50°C, then declines to 50% at +70°C. Input-voltage derating At 60 Hz, the input curve rises from 80% load at 85 VAC to 100% at 100 VAC, remaining at 100% through 264 VAC. Cooling / fan control Built-in cooling fan with ON/OFF control; fan ON at 35±15% load or when internal sensor RTH2 reaches at least 50°C. The sensor temperature is not an ambient-temperature rating. Working humidity 20–90% RH, non-condensing. Storage -40 to +85°C and 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Altitude derating For this fan-cooled supply, reduce the permissible ambient temperature by 5°C per additional 1000 m above 2000 m (6500 ft), as specified in the catalogue note. Temperature and low-input-voltage limits apply together; the upper working-temperature figure does not mean full rated power is available at every input voltage. Dimensions, Terminals and Installation Overall dimensions 218 × 105 × 63.5 mm (L × W × H); case 977A. Mechanical drawing tolerance ±1 mm. Mounting-hole labels Bottom: 4-M4 L=6; sides: 8-M4 L=4 (both sides). Use the complete drawing for thread engagement and hole positions; these labels are not accessory ordering codes. Hole-position references The drawing marks 152.4 mm spacing, a 32.8 mm end reference, and the 20.75/63.5 mm transverse references; side-view references include 38.3 and 12.5 mm. Follow the full drawing for each datum. AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG protective earth. DC output terminals 1–3 = -V; 4–6 = +V. Confirm polarity against this model’s terminal diagram. Terminal drawing dimensions The AC side marks 10 and 8.2 mm; the DC side marks 11 and 9.2 mm. These are drawing dimensions at their indicated locations, not a claim that every value is terminal pitch. Terminal projections AC-input side: 12 mm maximum; DC-output side: 18 mm maximum. Airflow and adjustment The mechanical drawing arrow points from the fan/input end toward the DC-output end. Keep the indicated airflow path unobstructed. The drawing identifies the LED and SVR1 output-voltage adjustment. Connector Mating Parts CN100 board connector HRS DF11-10DP-2DS or equivalent. Mating housing HRS DF11-10DS or equivalent, as listed for CN100. Mating terminal HRS DF11-**SC or equivalent is the printed terminal family; ** is not a confirmed orderable suffix. The catalogue identifies these mating parts but does not state that a cable, housing, terminals or mounting screws are included. Confirm the exact terminal suffix and wiring requirements before ordering; do not infer a complete accessory kit. Medical Safety, Leakage and Insulation Medical isolation Primary–secondary: 2 × MOOP; primary–earth: 1 × MOOP; secondary–earth: 1 × MOOP. Safety standards IEC 60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; EAC TP TC 004 approved. Design references include BS EN/EN60335-1 and BS EN/EN62368-1 (by request). Leakage current Earth leakage <300 µA at 264 VAC; touch leakage <100 µA at 264 VAC. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ for input–output, input–FG and output–FG, tested at 500 VDC / 25°C / 70% RH. The catalogue specifies MOOP-level isolation for this family; do not substitute a MOPP or BF claim. Finished-equipment safety must be evaluated for the actual installation. EMC and Integration Conditions Emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN60601-1-2; EAC TP TC020. EMC testing uses the supply mounted on a 360 × 360 mm metal plate, 1 mm thick. This is a component-level test arrangement, not a statement that a plate is included. Reconfirm EMC compliance in the final equipment using the manufacturer’s component-power-supply guidance. Weight, Reliability and Catalogue Reference Catalogue unit weight 1570 g; catalogue packing reference per unit (1.57 kg in PACKING), not a measured net weight or shipment weight. MTBF 138.7 K hours minimum, MIL-HDBK-217F at 25°C. These figures are reliability references, not a guaranteed service-life duration. Switching-frequency diagram PWM oscillator: 70 kHz. Manufacturer warranty statement The manufacturer catalogue lists a five-year warranty, subject to the applicable manufacturer terms. Applicable datasheet MSP-600-SPEC, 2024-10-30; PDF pages 13, 14, 15, 16.

    $435.19

  • MSP-600-12

    MEAN WELL MSP-600 series: Medical AC/DC Power Supply - MSP-600-12

    MEAN WELL MSP-600-12 is a single-output enclosed medical AC/DC power supply rated at 12 V, 53 A and 636 W. Select the load using the output rating and both ambient-temperature and input-voltage derating curves. Product Datasheet Download MEAN WELL MSP-600 Datasheet (PDF) The MSP-600 section is on PDF pages 13, 14, 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model MSP-600-12 Model code MSP identifies the series; 600 is the power-class designation; 12 identifies the nominal DC output voltage. Use the actual rating below for this model. Rated DC output 12 V / 53 A / 636 W Current range 0–53 A Built-in voltage adjustment 10.2–13.8 V, using SVR1; respect the rated current and power limits. Ripple and noise 150 mVp-p maximum; 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±1.0%, including setup tolerance, line regulation and load regulation. Line / load regulation ±0.3% / ±0.5% Efficiency 88% typical under the stated measurement conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. Input and Startup Input range 85–264 VAC, 120–370 VDC; universal AC input with active PFC. The low-line curve limits usable output. Frequency / surge tolerance 47–63 Hz; withstands 300 VAC surge input for 5 seconds. Power factor PF >0.93 at 230 VAC and >0.99 at 115 VAC, typical at full load. Input current 8.5 A at 115 VAC / 5 A at 230 VAC, typical. Inrush current 35 A at 115 VAC / 80 A at 230 VAC, typical; active inrush-current limiting is shown in the block diagram. Setup / rise time 1000 ms / 50 ms at 230 VAC; 2500 ms / 50 ms at 115 VAC, at full load. Hold-up time 16 ms at 230 VAC and 16 ms at 115 VAC, typical at full load. Setup time is measured at the first cold start; repeated power cycling can increase it. Below 40 VAC, performance may degrade and the final-equipment manufacturer must reconfirm basic safety and essential performance; this note does not extend the rated input range. Protection Short circuit / overload Short-circuit protection is listed. Overload threshold: 105–135% of rated output power; constant-current limiting with automatic recovery after the fault is removed. Over-voltage protection 14.4–16.8 V; output shuts down and requires re-powering to recover. Over-temperature protection Output shuts down and automatically recovers after temperature decreases. Remote Control, Standby and DC-OK Remote ON/OFF CN100 pin 3 (RC+) to pin 4 (RC-): short or 0–0.8 V = OFF; open or 4–10 V = ON. Remote-off no-load consumption <0.8 W with RC+ and RC- shorted or at 0–0.8 V. Standby auxiliary output 5 V / 0.3 A; 4.75–5.25 V, ±5% tolerance, 50 mVp-p maximum ripple. AUX pin 2 is referenced to AUXG pin 1 and is not switched off by remote ON/OFF. DC-OK signal TTL output, referenced to CN100 GND pin 6 or 8: 3.3–5.6 V when the supply is ON; 0–1 V when OFF. Remote sense Up to 0.5 V load-wiring drop compensation. Connect +S pin 9 to load positive and -S pin 10 to load negative; twist the sense pair to minimize pickup. CN100 Control Connector Pin 1 — AUXG Auxiliary-output ground. This signal return is isolated from the +V/-V output terminals. Pin 2 — AUX Auxiliary voltage output, referenced to pin 1; 0.3 A maximum. Pins 3 / 4 — RC+ / RC- Remote-control input and return: short = OFF; open = ON. Pin 5 — CS CS is identified in the common connector table; active current sharing is specified only for MSP-600-24, -36 and -48, not this voltage version. Pins 6 / 8 — GND Connected to output -V; DC-OK signal return. Pin 7 — DC-OK TTL status signal, HIGH when the supply turns on; referenced to pin 8. Pins 9 / 10 — +S / -S Positive and negative remote sense; connect as shown in the model-specific wiring diagram. Parallel-operation Boundary The active current-sharing arrangement in this catalogue is limited to the 24 V, 36 V and 48 V MSP-600 versions. Do not apply that function to this model merely because the common connector drawing labels pin 5 as CS. Cooling, Derating and Environment Temperature and load The specification lists -40 to +70°C subject to the derating curve. Horizontal mounting: the plotted load remains at 100% from -40°C through +50°C, then declines to 50% at +70°C. Input-voltage derating At 60 Hz, the input curve rises from 80% load at 85 VAC to 100% at 100 VAC, remaining at 100% through 264 VAC. Cooling / fan control Built-in cooling fan with ON/OFF control; fan ON at 35±15% load or when internal sensor RTH2 reaches at least 50°C. The sensor temperature is not an ambient-temperature rating. Working humidity 20–90% RH, non-condensing. Storage -40 to +85°C and 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Altitude derating For this fan-cooled supply, reduce the permissible ambient temperature by 5°C per additional 1000 m above 2000 m (6500 ft), as specified in the catalogue note. Temperature and low-input-voltage limits apply together; the upper working-temperature figure does not mean full rated power is available at every input voltage. Dimensions, Terminals and Installation Overall dimensions 218 × 105 × 63.5 mm (L × W × H); case 977A. Mechanical drawing tolerance ±1 mm. Mounting-hole labels Bottom: 4-M4 L=6; sides: 8-M4 L=4 (both sides). Use the complete drawing for thread engagement and hole positions; these labels are not accessory ordering codes. Hole-position references The drawing marks 152.4 mm spacing, a 32.8 mm end reference, and the 20.75/63.5 mm transverse references; side-view references include 38.3 and 12.5 mm. Follow the full drawing for each datum. AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG protective earth. DC output terminals 1–3 = -V; 4–6 = +V. Confirm polarity against this model’s terminal diagram. Terminal drawing dimensions The AC side marks 10 and 8.2 mm; the DC side marks 11 and 9.2 mm. These are drawing dimensions at their indicated locations, not a claim that every value is terminal pitch. Terminal projections AC-input side: 12 mm maximum; DC-output side: 18 mm maximum. Airflow and adjustment The mechanical drawing arrow points from the fan/input end toward the DC-output end. Keep the indicated airflow path unobstructed. The drawing identifies the LED and SVR1 output-voltage adjustment. Connector Mating Parts CN100 board connector HRS DF11-10DP-2DS or equivalent. Mating housing HRS DF11-10DS or equivalent, as listed for CN100. Mating terminal HRS DF11-**SC or equivalent is the printed terminal family; ** is not a confirmed orderable suffix. The catalogue identifies these mating parts but does not state that a cable, housing, terminals or mounting screws are included. Confirm the exact terminal suffix and wiring requirements before ordering; do not infer a complete accessory kit. Medical Safety, Leakage and Insulation Medical isolation Primary–secondary: 2 × MOOP; primary–earth: 1 × MOOP; secondary–earth: 1 × MOOP. Safety standards IEC 60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; EAC TP TC 004 approved. Design references include BS EN/EN60335-1 and BS EN/EN62368-1 (by request). Leakage current Earth leakage <300 µA at 264 VAC; touch leakage <100 µA at 264 VAC. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ for input–output, input–FG and output–FG, tested at 500 VDC / 25°C / 70% RH. The catalogue specifies MOOP-level isolation for this family; do not substitute a MOPP or BF claim. Finished-equipment safety must be evaluated for the actual installation. EMC and Integration Conditions Emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN60601-1-2; EAC TP TC020. EMC testing uses the supply mounted on a 360 × 360 mm metal plate, 1 mm thick. This is a component-level test arrangement, not a statement that a plate is included. Reconfirm EMC compliance in the final equipment using the manufacturer’s component-power-supply guidance. Weight, Reliability and Catalogue Reference Catalogue unit weight 1570 g; catalogue packing reference per unit (1.57 kg in PACKING), not a measured net weight or shipment weight. MTBF 138.7 K hours minimum, MIL-HDBK-217F at 25°C. These figures are reliability references, not a guaranteed service-life duration. Switching-frequency diagram PWM oscillator: 70 kHz. Manufacturer warranty statement The manufacturer catalogue lists a five-year warranty, subject to the applicable manufacturer terms. Applicable datasheet MSP-600-SPEC, 2024-10-30; PDF pages 13, 14, 15, 16.

    $435.19

  • MSP-600-7.5

    MEAN WELL MSP-600 series: Medical AC/DC Power Supply - MSP-600-7.5

    MEAN WELL MSP-600-7.5 is a single-output enclosed medical AC/DC power supply rated at 7.5 V, 80 A and 600 W. Select the load using the output rating and both ambient-temperature and input-voltage derating curves. Product Datasheet Download MEAN WELL MSP-600 Datasheet (PDF) The MSP-600 section is on PDF pages 13, 14, 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model MSP-600-7.5 Model code MSP identifies the series; 600 is the power-class designation; 7.5 identifies the nominal DC output voltage. Use the actual rating below for this model. Rated DC output 7.5 V / 80 A / 600 W Current range 0–80 A Built-in voltage adjustment 6.8–9 V, using SVR1; respect the rated current and power limits. Ripple and noise 150 mVp-p maximum; 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±2.0%, including setup tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±1.0% Efficiency 86% typical under the stated measurement conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. Input and Startup Input range 85–264 VAC, 120–370 VDC; universal AC input with active PFC. The low-line curve limits usable output. Frequency / surge tolerance 47–63 Hz; withstands 300 VAC surge input for 5 seconds. Power factor PF >0.93 at 230 VAC and >0.99 at 115 VAC, typical at full load. Input current 8.5 A at 115 VAC / 5 A at 230 VAC, typical. Inrush current 35 A at 115 VAC / 80 A at 230 VAC, typical; active inrush-current limiting is shown in the block diagram. Setup / rise time 1000 ms / 50 ms at 230 VAC; 2500 ms / 50 ms at 115 VAC, at full load. Hold-up time 16 ms at 230 VAC and 16 ms at 115 VAC, typical at full load. Setup time is measured at the first cold start; repeated power cycling can increase it. Below 40 VAC, performance may degrade and the final-equipment manufacturer must reconfirm basic safety and essential performance; this note does not extend the rated input range. Protection Short circuit / overload Short-circuit protection is listed. Overload threshold: 105–135% of rated output power; constant-current limiting with automatic recovery after the fault is removed. Over-voltage protection 9.4–10.9 V; output shuts down and requires re-powering to recover. Over-temperature protection Output shuts down and automatically recovers after temperature decreases. Remote Control, Standby and DC-OK Remote ON/OFF CN100 pin 3 (RC+) to pin 4 (RC-): short or 0–0.8 V = OFF; open or 4–10 V = ON. Remote-off no-load consumption <0.8 W with RC+ and RC- shorted or at 0–0.8 V. Standby auxiliary output 5 V / 0.3 A; 4.75–5.25 V, ±5% tolerance, 50 mVp-p maximum ripple. AUX pin 2 is referenced to AUXG pin 1 and is not switched off by remote ON/OFF. DC-OK signal TTL output, referenced to CN100 GND pin 6 or 8: 3.3–5.6 V when the supply is ON; 0–1 V when OFF. Remote sense Up to 0.5 V load-wiring drop compensation. Connect +S pin 9 to load positive and -S pin 10 to load negative; twist the sense pair to minimize pickup. CN100 Control Connector Pin 1 — AUXG Auxiliary-output ground. This signal return is isolated from the +V/-V output terminals. Pin 2 — AUX Auxiliary voltage output, referenced to pin 1; 0.3 A maximum. Pins 3 / 4 — RC+ / RC- Remote-control input and return: short = OFF; open = ON. Pin 5 — CS CS is identified in the common connector table; active current sharing is specified only for MSP-600-24, -36 and -48, not this voltage version. Pins 6 / 8 — GND Connected to output -V; DC-OK signal return. Pin 7 — DC-OK TTL status signal, HIGH when the supply turns on; referenced to pin 8. Pins 9 / 10 — +S / -S Positive and negative remote sense; connect as shown in the model-specific wiring diagram. Parallel-operation Boundary The active current-sharing arrangement in this catalogue is limited to the 24 V, 36 V and 48 V MSP-600 versions. Do not apply that function to this model merely because the common connector drawing labels pin 5 as CS. Cooling, Derating and Environment Temperature and load The specification lists -40 to +70°C subject to the derating curve. Horizontal mounting: the plotted load remains at 100% from -40°C through +50°C, then declines to 50% at +70°C. Input-voltage derating At 60 Hz, the input curve rises from 80% load at 85 VAC to 100% at 100 VAC, remaining at 100% through 264 VAC. Cooling / fan control Built-in cooling fan with ON/OFF control; fan ON at 35±15% load or when internal sensor RTH2 reaches at least 50°C. The sensor temperature is not an ambient-temperature rating. Working humidity 20–90% RH, non-condensing. Storage -40 to +85°C and 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Altitude derating For this fan-cooled supply, reduce the permissible ambient temperature by 5°C per additional 1000 m above 2000 m (6500 ft), as specified in the catalogue note. Temperature and low-input-voltage limits apply together; the upper working-temperature figure does not mean full rated power is available at every input voltage. Dimensions, Terminals and Installation Overall dimensions 218 × 105 × 63.5 mm (L × W × H); case 977A. Mechanical drawing tolerance ±1 mm. Mounting-hole labels Bottom: 4-M4 L=6; sides: 8-M4 L=4 (both sides). Use the complete drawing for thread engagement and hole positions; these labels are not accessory ordering codes. Hole-position references The drawing marks 152.4 mm spacing, a 32.8 mm end reference, and the 20.75/63.5 mm transverse references; side-view references include 38.3 and 12.5 mm. Follow the full drawing for each datum. AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG protective earth. DC output terminals 1–3 = -V; 4–6 = +V. Confirm polarity against this model’s terminal diagram. Terminal drawing dimensions The AC side marks 10 and 8.2 mm; the DC side marks 11 and 9.2 mm. These are drawing dimensions at their indicated locations, not a claim that every value is terminal pitch. Terminal projections AC-input side: 12 mm maximum; DC-output side: 18 mm maximum. Airflow and adjustment The mechanical drawing arrow points from the fan/input end toward the DC-output end. Keep the indicated airflow path unobstructed. The drawing identifies the LED and SVR1 output-voltage adjustment. Connector Mating Parts CN100 board connector HRS DF11-10DP-2DS or equivalent. Mating housing HRS DF11-10DS or equivalent, as listed for CN100. Mating terminal HRS DF11-**SC or equivalent is the printed terminal family; ** is not a confirmed orderable suffix. The catalogue identifies these mating parts but does not state that a cable, housing, terminals or mounting screws are included. Confirm the exact terminal suffix and wiring requirements before ordering; do not infer a complete accessory kit. Medical Safety, Leakage and Insulation Medical isolation Primary–secondary: 2 × MOOP; primary–earth: 1 × MOOP; secondary–earth: 1 × MOOP. Safety standards IEC 60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; EAC TP TC 004 approved. Design references include BS EN/EN60335-1 and BS EN/EN62368-1 (by request). Leakage current Earth leakage <300 µA at 264 VAC; touch leakage <100 µA at 264 VAC. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ for input–output, input–FG and output–FG, tested at 500 VDC / 25°C / 70% RH. The catalogue specifies MOOP-level isolation for this family; do not substitute a MOPP or BF claim. Finished-equipment safety must be evaluated for the actual installation. EMC and Integration Conditions Emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN60601-1-2; EAC TP TC020. EMC testing uses the supply mounted on a 360 × 360 mm metal plate, 1 mm thick. This is a component-level test arrangement, not a statement that a plate is included. Reconfirm EMC compliance in the final equipment using the manufacturer’s component-power-supply guidance. Weight, Reliability and Catalogue Reference Catalogue unit weight 1570 g; catalogue packing reference per unit (1.57 kg in PACKING), not a measured net weight or shipment weight. MTBF 138.7 K hours minimum, MIL-HDBK-217F at 25°C. These figures are reliability references, not a guaranteed service-life duration. Switching-frequency diagram PWM oscillator: 70 kHz. Manufacturer warranty statement The manufacturer catalogue lists a five-year warranty, subject to the applicable manufacturer terms. Applicable datasheet MSP-600-SPEC, 2024-10-30; PDF pages 13, 14, 15, 16.

    $435.19

  • MSP-600-5

    MEAN WELL MSP-600 series: Medical AC/DC Power Supply - MSP-600-5

    MEAN WELL MSP-600-5 is a single-output enclosed medical AC/DC power supply rated at 5 V, 120 A and 600 W. Select the load using the output rating and both ambient-temperature and input-voltage derating curves. Product Datasheet Download MEAN WELL MSP-600 Datasheet (PDF) The MSP-600 section is on PDF pages 13, 14, 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model MSP-600-5 Model code MSP identifies the series; 600 is the power-class designation; 5 identifies the nominal DC output voltage. Use the actual rating below for this model. Rated DC output 5 V / 120 A / 600 W Current range 0–120 A Built-in voltage adjustment 4.3–5.8 V, using SVR1; respect the rated current and power limits. Ripple and noise 150 mVp-p maximum; 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±2.0%, including setup tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±1.0% Efficiency 82% typical under the stated measurement conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. Input and Startup Input range 85–264 VAC, 120–370 VDC; universal AC input with active PFC. The low-line curve limits usable output. Frequency / surge tolerance 47–63 Hz; withstands 300 VAC surge input for 5 seconds. Power factor PF >0.93 at 230 VAC and >0.99 at 115 VAC, typical at full load. Input current 8.5 A at 115 VAC / 5 A at 230 VAC, typical. Inrush current 35 A at 115 VAC / 80 A at 230 VAC, typical; active inrush-current limiting is shown in the block diagram. Setup / rise time 1000 ms / 50 ms at 230 VAC; 2500 ms / 50 ms at 115 VAC, at full load. Hold-up time 16 ms at 230 VAC and 16 ms at 115 VAC, typical at full load. Setup time is measured at the first cold start; repeated power cycling can increase it. Below 40 VAC, performance may degrade and the final-equipment manufacturer must reconfirm basic safety and essential performance; this note does not extend the rated input range. Protection Short circuit / overload Short-circuit protection is listed. Overload threshold: 105–135% of rated output power; constant-current limiting with automatic recovery after the fault is removed. Over-voltage protection 6–7 V; output shuts down and requires re-powering to recover. Over-temperature protection Output shuts down and automatically recovers after temperature decreases. Remote Control, Standby and DC-OK Remote ON/OFF CN100 pin 3 (RC+) to pin 4 (RC-): short or 0–0.8 V = OFF; open or 4–10 V = ON. Remote-off no-load consumption <0.8 W with RC+ and RC- shorted or at 0–0.8 V. Standby auxiliary output 5 V / 0.3 A; 4.75–5.25 V, ±5% tolerance, 50 mVp-p maximum ripple. AUX pin 2 is referenced to AUXG pin 1 and is not switched off by remote ON/OFF. DC-OK signal TTL output, referenced to CN100 GND pin 6 or 8: 3.3–5.6 V when the supply is ON; 0–1 V when OFF. Remote sense Up to 0.5 V load-wiring drop compensation. Connect +S pin 9 to load positive and -S pin 10 to load negative; twist the sense pair to minimize pickup. CN100 Control Connector Pin 1 — AUXG Auxiliary-output ground. This signal return is isolated from the +V/-V output terminals. Pin 2 — AUX Auxiliary voltage output, referenced to pin 1; 0.3 A maximum. Pins 3 / 4 — RC+ / RC- Remote-control input and return: short = OFF; open = ON. Pin 5 — CS CS is identified in the common connector table; active current sharing is specified only for MSP-600-24, -36 and -48, not this voltage version. Pins 6 / 8 — GND Connected to output -V; DC-OK signal return. Pin 7 — DC-OK TTL status signal, HIGH when the supply turns on; referenced to pin 8. Pins 9 / 10 — +S / -S Positive and negative remote sense; connect as shown in the model-specific wiring diagram. Parallel-operation Boundary The active current-sharing arrangement in this catalogue is limited to the 24 V, 36 V and 48 V MSP-600 versions. Do not apply that function to this model merely because the common connector drawing labels pin 5 as CS. Cooling, Derating and Environment Temperature and load The specification lists -40 to +70°C subject to the derating curve. Horizontal mounting: the plotted load remains at 100% from -40°C through +50°C, then declines to 50% at +70°C. Input-voltage derating At 60 Hz, the input curve rises from 80% load at 85 VAC to 100% at 100 VAC, remaining at 100% through 264 VAC. Cooling / fan control Built-in cooling fan with ON/OFF control; fan ON at 35±15% load or when internal sensor RTH2 reaches at least 50°C. The sensor temperature is not an ambient-temperature rating. Working humidity 20–90% RH, non-condensing. Storage -40 to +85°C and 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Altitude derating For this fan-cooled supply, reduce the permissible ambient temperature by 5°C per additional 1000 m above 2000 m (6500 ft), as specified in the catalogue note. Temperature and low-input-voltage limits apply together; the upper working-temperature figure does not mean full rated power is available at every input voltage. Dimensions, Terminals and Installation Overall dimensions 218 × 105 × 63.5 mm (L × W × H); case 977A. Mechanical drawing tolerance ±1 mm. Mounting-hole labels Bottom: 4-M4 L=6; sides: 8-M4 L=4 (both sides). Use the complete drawing for thread engagement and hole positions; these labels are not accessory ordering codes. Hole-position references The drawing marks 152.4 mm spacing, a 32.8 mm end reference, and the 20.75/63.5 mm transverse references; side-view references include 38.3 and 12.5 mm. Follow the full drawing for each datum. AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG protective earth. DC output terminals 1–3 = -V; 4–6 = +V. Confirm polarity against this model’s terminal diagram. Terminal drawing dimensions The AC side marks 10 and 8.2 mm; the DC side marks 11 and 9.2 mm. These are drawing dimensions at their indicated locations, not a claim that every value is terminal pitch. Terminal projections AC-input side: 12 mm maximum; DC-output side: 18 mm maximum. Airflow and adjustment The mechanical drawing arrow points from the fan/input end toward the DC-output end. Keep the indicated airflow path unobstructed. The drawing identifies the LED and SVR1 output-voltage adjustment. Connector Mating Parts CN100 board connector HRS DF11-10DP-2DS or equivalent. Mating housing HRS DF11-10DS or equivalent, as listed for CN100. Mating terminal HRS DF11-**SC or equivalent is the printed terminal family; ** is not a confirmed orderable suffix. The catalogue identifies these mating parts but does not state that a cable, housing, terminals or mounting screws are included. Confirm the exact terminal suffix and wiring requirements before ordering; do not infer a complete accessory kit. Medical Safety, Leakage and Insulation Medical isolation Primary–secondary: 2 × MOOP; primary–earth: 1 × MOOP; secondary–earth: 1 × MOOP. Safety standards IEC 60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; EAC TP TC 004 approved. Design references include BS EN/EN60335-1 and BS EN/EN62368-1 (by request). Leakage current Earth leakage <300 µA at 264 VAC; touch leakage <100 µA at 264 VAC. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ for input–output, input–FG and output–FG, tested at 500 VDC / 25°C / 70% RH. The catalogue specifies MOOP-level isolation for this family; do not substitute a MOPP or BF claim. Finished-equipment safety must be evaluated for the actual installation. EMC and Integration Conditions Emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN60601-1-2; EAC TP TC020. EMC testing uses the supply mounted on a 360 × 360 mm metal plate, 1 mm thick. This is a component-level test arrangement, not a statement that a plate is included. Reconfirm EMC compliance in the final equipment using the manufacturer’s component-power-supply guidance. Weight, Reliability and Catalogue Reference Catalogue unit weight 1570 g; catalogue packing reference per unit (1.57 kg in PACKING), not a measured net weight or shipment weight. MTBF 138.7 K hours minimum, MIL-HDBK-217F at 25°C. These figures are reliability references, not a guaranteed service-life duration. Switching-frequency diagram PWM oscillator: 70 kHz. Manufacturer warranty statement The manufacturer catalogue lists a five-year warranty, subject to the applicable manufacturer terms. Applicable datasheet MSP-600-SPEC, 2024-10-30; PDF pages 13, 14, 15, 16.

    $435.19

  • MSP-600-3.3

    MEAN WELL MSP-600 series: Medical AC/DC Power Supply - MSP-600-3.3

    MEAN WELL MSP-600-3.3 is a single-output enclosed medical AC/DC power supply rated at 3.3 V, 120 A and 396 W. Select the load using the output rating and both ambient-temperature and input-voltage derating curves. Product Datasheet Download MEAN WELL MSP-600 Datasheet (PDF) The MSP-600 section is on PDF pages 13, 14, 15, 16. Refer to the complete mechanical drawings and notes when planning installation. Model and Output Complete model MSP-600-3.3 Model code MSP identifies the series; 600 is the power-class designation; 3.3 identifies the nominal DC output voltage. Use the actual rating below for this model. Rated DC output 3.3 V / 120 A / 396 W Current range 0–120 A Built-in voltage adjustment 2.8–3.8 V, using SVR1; respect the rated current and power limits. Ripple and noise 120 mVp-p maximum; 20 MHz bandwidth; 12-inch twisted pair terminated with parallel 0.1 µF and 47 µF capacitors. Voltage tolerance ±2.0%, including setup tolerance, line regulation and load regulation. Line / load regulation ±0.5% / ±1.0% Efficiency 78.5% typical under the stated measurement conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. Input and Startup Input range 85–264 VAC, 120–370 VDC; universal AC input with active PFC. The low-line curve limits usable output. Frequency / surge tolerance 47–63 Hz; withstands 300 VAC surge input for 5 seconds. Power factor PF >0.93 at 230 VAC and >0.99 at 115 VAC, typical at full load. Input current 8.5 A at 115 VAC / 5 A at 230 VAC, typical. Inrush current 35 A at 115 VAC / 80 A at 230 VAC, typical; active inrush-current limiting is shown in the block diagram. Setup / rise time 1000 ms / 50 ms at 230 VAC; 2500 ms / 50 ms at 115 VAC, at full load. Hold-up time 16 ms at 230 VAC and 16 ms at 115 VAC, typical at full load. Setup time is measured at the first cold start; repeated power cycling can increase it. Below 40 VAC, performance may degrade and the final-equipment manufacturer must reconfirm basic safety and essential performance; this note does not extend the rated input range. Protection Short circuit / overload Short-circuit protection is listed. Overload threshold: 105–135% of rated output power; constant-current limiting with automatic recovery after the fault is removed. Over-voltage protection 3.96–4.62 V; output shuts down and requires re-powering to recover. Over-temperature protection Output shuts down and automatically recovers after temperature decreases. Remote Control, Standby and DC-OK Remote ON/OFF CN100 pin 3 (RC+) to pin 4 (RC-): short or 0–0.8 V = OFF; open or 4–10 V = ON. Remote-off no-load consumption <0.8 W with RC+ and RC- shorted or at 0–0.8 V. Standby auxiliary output 5 V / 0.3 A; 4.75–5.25 V, ±5% tolerance, 50 mVp-p maximum ripple. AUX pin 2 is referenced to AUXG pin 1 and is not switched off by remote ON/OFF. DC-OK signal TTL output, referenced to CN100 GND pin 6 or 8: 3.3–5.6 V when the supply is ON; 0–1 V when OFF. Remote sense Up to 0.5 V load-wiring drop compensation. Connect +S pin 9 to load positive and -S pin 10 to load negative; twist the sense pair to minimize pickup. CN100 Control Connector Pin 1 — AUXG Auxiliary-output ground. This signal return is isolated from the +V/-V output terminals. Pin 2 — AUX Auxiliary voltage output, referenced to pin 1; 0.3 A maximum. Pins 3 / 4 — RC+ / RC- Remote-control input and return: short = OFF; open = ON. Pin 5 — CS CS is identified in the common connector table; active current sharing is specified only for MSP-600-24, -36 and -48, not this voltage version. Pins 6 / 8 — GND Connected to output -V; DC-OK signal return. Pin 7 — DC-OK TTL status signal, HIGH when the supply turns on; referenced to pin 8. Pins 9 / 10 — +S / -S Positive and negative remote sense; connect as shown in the model-specific wiring diagram. Parallel-operation Boundary The active current-sharing arrangement in this catalogue is limited to the 24 V, 36 V and 48 V MSP-600 versions. Do not apply that function to this model merely because the common connector drawing labels pin 5 as CS. Cooling, Derating and Environment Temperature and load The specification lists -40 to +70°C subject to the derating curve. Horizontal mounting: the plotted load remains at 100% from -40°C through +50°C, then declines to 50% at +70°C. Input-voltage derating At 60 Hz, the input curve rises from 80% load at 85 VAC to 100% at 100 VAC, remaining at 100% through 264 VAC. Cooling / fan control Built-in cooling fan with ON/OFF control; fan ON at 35±15% load or when internal sensor RTH2 reaches at least 50°C. The sensor temperature is not an ambient-temperature rating. Working humidity 20–90% RH, non-condensing. Storage -40 to +85°C and 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5 G; 10 minutes per cycle and 60 minutes along each X, Y and Z axis. Altitude derating For this fan-cooled supply, reduce the permissible ambient temperature by 5°C per additional 1000 m above 2000 m (6500 ft), as specified in the catalogue note. Temperature and low-input-voltage limits apply together; the upper working-temperature figure does not mean full rated power is available at every input voltage. Dimensions, Terminals and Installation Overall dimensions 218 × 105 × 63.5 mm (L × W × H); case 977A. Mechanical drawing tolerance ±1 mm. Mounting-hole labels Bottom: 4-M4 L=6; sides: 8-M4 L=4 (both sides). Use the complete drawing for thread engagement and hole positions; these labels are not accessory ordering codes. Hole-position references The drawing marks 152.4 mm spacing, a 32.8 mm end reference, and the 20.75/63.5 mm transverse references; side-view references include 38.3 and 12.5 mm. Follow the full drawing for each datum. AC input terminals 1 = AC/L; 2 = AC/N; 3 = FG protective earth. DC output terminals 1–3 = -V; 4–6 = +V. Confirm polarity against this model’s terminal diagram. Terminal drawing dimensions The AC side marks 10 and 8.2 mm; the DC side marks 11 and 9.2 mm. These are drawing dimensions at their indicated locations, not a claim that every value is terminal pitch. Terminal projections AC-input side: 12 mm maximum; DC-output side: 18 mm maximum. Airflow and adjustment The mechanical drawing arrow points from the fan/input end toward the DC-output end. Keep the indicated airflow path unobstructed. The drawing identifies the LED and SVR1 output-voltage adjustment. Connector Mating Parts CN100 board connector HRS DF11-10DP-2DS or equivalent. Mating housing HRS DF11-10DS or equivalent, as listed for CN100. Mating terminal HRS DF11-**SC or equivalent is the printed terminal family; ** is not a confirmed orderable suffix. The catalogue identifies these mating parts but does not state that a cable, housing, terminals or mounting screws are included. Confirm the exact terminal suffix and wiring requirements before ordering; do not infer a complete accessory kit. Medical Safety, Leakage and Insulation Medical isolation Primary–secondary: 2 × MOOP; primary–earth: 1 × MOOP; secondary–earth: 1 × MOOP. Safety standards IEC 60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No. 60601-1:2014+A2; EAC TP TC 004 approved. Design references include BS EN/EN60335-1 and BS EN/EN62368-1 (by request). Leakage current Earth leakage <300 µA at 264 VAC; touch leakage <100 µA at 264 VAC. Withstand voltage Input–output: 4 kVAC; input–FG: 2 kVAC; output–FG: 0.5 kVAC. Insulation resistance 100 MΩ for input–output, input–FG and output–FG, tested at 500 VDC / 25°C / 70% RH. The catalogue specifies MOOP-level isolation for this family; do not substitute a MOPP or BF claim. Finished-equipment safety must be evaluated for the actual installation. EMC and Integration Conditions Emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. Immunity BS EN/EN61000-4-2, -3, -4, -5, -6, -8 and -11; BS EN/EN60601-1-2; EAC TP TC020. EMC testing uses the supply mounted on a 360 × 360 mm metal plate, 1 mm thick. This is a component-level test arrangement, not a statement that a plate is included. Reconfirm EMC compliance in the final equipment using the manufacturer’s component-power-supply guidance. Weight, Reliability and Catalogue Reference Catalogue unit weight 1570 g; catalogue packing reference per unit (1.57 kg in PACKING), not a measured net weight or shipment weight. MTBF 138.7 K hours minimum, MIL-HDBK-217F at 25°C. These figures are reliability references, not a guaranteed service-life duration. Switching-frequency diagram PWM oscillator: 70 kHz. Manufacturer warranty statement The manufacturer catalogue lists a five-year warranty, subject to the applicable manufacturer terms. Applicable datasheet MSP-600-SPEC, 2024-10-30; PDF pages 13, 14, 15, 16.

    $435.19

  • MSP-450-48

    MEAN WELL MSP-450 series: Enclosed Medical AC/DC Power Supply - MSP-450-48

    MEAN WELL MSP-450-48 is a single-output enclosed medical-type AC/DC power supply rated 48 VDC, 9.5 A and 456 W. It combines active PFC, MOOP-level isolation, controlled fan cooling, remote sense, remote ON/OFF, a DC-OK signal and a separate 5 V standby output. Apply the model-specific input, leakage and derating limits below. Product Datasheet Download MEAN WELL MSP-450 Datasheet (PDF) The MSP-450 section is on PDF pages 10, 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Exact Model and Output Ratings Complete model MSP-450-48: MSP-450 single-output enclosed medical-type AC/DC power supply; -48 identifies the nominal 48 VDC output. Catalogue revision 2025-12-05. Rated output 48 VDC; 9.5 A; 456 W. Current range: 0–9.5 A. These are the exact model ratings, subject to the derating limits below. Output voltage adjustment 40.8–55.2 V using SVR. Observe the rated current and rated power limits when adjusting output voltage. Ripple and noise 240 mVp-p maximum; measured with 20 MHz bandwidth, a 12-inch twisted pair and 0.1 µF + 47 µF parallel capacitors. Voltage accuracy Voltage tolerance ±1.0%; line regulation ±0.2%; load regulation ±0.5%. Tolerance includes setup, line and load regulation. Typical efficiency 89.5%, at the catalogue default test conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. The family name is not a substitute for this exact model’s output rating. Input and Timing Normal input range 85–264 VAC or 120–370 VDC; AC frequency 47–63 Hz. Apply low-input derating. Active PFC Typical PF >0.95 at 230 VAC and >0.99 at 115 VAC, both at full load. Typical AC current 5 A at 115 VAC; 2.4 A at 230 VAC. Inrush / surge withstand Typical inrush 35 A at 115 VAC and 70 A at 230 VAC. Active inrush-current limiting is shown in the block diagram. Withstands 300 VAC surge input for 5 seconds; 300 VAC is not the continuous input rating. Setup / rise time 1000 ms / 100 ms at 230 VAC; 2500 ms / 100 ms at 115 VAC, at full load. Hold-up time 16 ms typical at 230 VAC and 16 ms typical at 115 VAC, at full load. No-load consumption The feature list states no-load input power below 0.6 W. Note 6 specifies below 0.5 W with the main output remotely OFF: RC+ to RC− at 0–0.8 V or shorted. Setup time is measured at the first cold start. Repeated ON/OFF switching may increase setup time. Below 40 VAC, the catalogue warns of possible performance degradation and requires the final-equipment manufacturer to reconfirm basic safety and essential performance. This is an abnormal low-input condition, not an extension of the normal 85–264 VAC operating range. Medical Isolation, Leakage and Approval Scope Medical isolation level Primary-to-secondary: 2 × MOOP; primary-to-earth: 1 × MOOP. Secondary-to-earth: 1 × MOOP. MOOP stands for means of operator protection. Leakage at 264 VAC Earth leakage <300 µA; touch leakage <100 µA. Listed safety approvals IEC60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Design references by request BS EN/EN60335-1 and BS EN/EN62368-1 are listed as design references, by request. Withstand voltage Input-to-output: 4 kVAC; input-to-FG: 2 kVAC; output-to-FG: 0.5 kVAC. Insulation resistance 100 MΩ minimum for input/output, input/FG and output/FG, tested at 500 VDC, 25°C and 70% RH. The stated insulation classification is MOOP. These pages do not establish a MOPP patient-protection rating or certify the completed medical equipment. Match the required insulation, leakage, grounding and final-system safety evaluation to the intended application. Protection and Cooling Short circuit / overload Short-circuit protection is listed. Overload threshold: 105–135% of rated output power, using constant-current limiting; automatic recovery after the fault is removed. Overvoltage 57.6–67.2 V threshold for this model; shuts down the output, with re-powering required to recover. Overtemperature Shuts down the output; automatic recovery after temperature falls. Controlled cooling fan Built-in fan ON/OFF control: fan turns on at a typical load threshold of 20 ±10%, or when internal thermistor RTH2 reaches at least 50°C. RTH2 is not the ambient-temperature rating. Ambient derating Horizontal mounting: 100% load from −40°C to +50°C, decreasing linearly to 50% at +70°C. The operating range is −40°C to +70°C, subject to this curve. Input-voltage derating At 60 Hz, the curve rises from 80% load at 85 VAC to 100% at 100 VAC, then remains at 100% through 264 VAC. Altitude derating For this fan-cooled model, reduce the allowed ambient temperature by 5°C per additional 1000 m above 2000 m. Apply input-voltage, temperature and output-rating limits together. Keep the indicated fan inlet/outlet and surrounding airflow path unobstructed; verify cooling in the final enclosure. No numerical mounting-clearance distance is specified in these catalogue pages. Standby, Remote Control and DC OK Standby output 5 V, 0.3 A maximum; tolerance ±5% (4.75–5.25 V), ripple 50 mVp-p maximum. AUX is not switched by the main-output remote ON/OFF control. Standby reference AUX pin 3 returns to AUXG pin 4. AUXG is isolated from the main +V/−V terminals; do not substitute the DC-OK ground. Remote ON/OFF Between RC+ pin 1 and RC− pin 2: 4–10 V or open contact = power ON; 0–0.8 V or short contact = power OFF. DC-OK signal DC-OK pin 5 is referenced to GND pin 6, which connects to main −V. TTL high when the PSU is ON: 3.3–5.6 V; OFF: 0–1 V. Remote sense Connect +S pin 7 to the positive load terminal and −S pin 8 to the negative load terminal. Twist +S and −S together; maximum line-drop compensation is 0.5 V. Use the complete function and connection drawings on PDF page 12. DC-OK is a TTL status output, not a dry relay contact; no additional contact-current or sourcing-current rating is specified here. The documented functions for this family are standby, remote ON/OFF, DC OK and remote sense. No active current-sharing or parallel-unit count is specified for these models. Power Terminals and CN100 Pin Assignment AC input terminals 1 / 2 / 3 AC/L / AC/N / FG (frame ground), respectively. Separate DC output terminals 1–3 / 4–6 DC terminals 1–3: −V; DC terminals 4–6: +V. Use the separate AC and DC numbering shown in the drawing. CN100 pin 1 — RC+ Remote ON/OFF control input relative to RC− pin 2; an open contact enables the main output and a short disables it. CN100 pin 2 — RC- Remote-control ground. CN100 pin 3 — AUX 4.75–5.25 V auxiliary output, maximum 0.3 A, referenced to AUXG pin 4; remains available independently of remote ON/OFF control. CN100 pin 4 — AUXG Auxiliary return, isolated from the main +V and −V output terminals. CN100 pin 5 — DC-OK TTL status output referenced to GND pin 6; high when the PSU turns on. CN100 pin 6 — GND DC-OK signal return; connected to the main −V output. CN100 pin 7 — +S Positive remote-sense lead to the positive load terminal; use a twisted pair with −S. CN100 pin 8 — -S Negative remote-sense lead to the negative load terminal; use a twisted pair with +S. Pin numbers refer to the actual connector orientation shown on PDF page 11. Verify polarity and the separate return functions before wiring. Mating Connector and Installation Parts Board connector CN100: HRS DF11-8DP-2DS or equivalent, as printed in the catalogue. Mating housing HRS DF11-8DS or equivalent, as printed. Contact reference HRS DF11-**SC or equivalent. The asterisks are a contact-family placeholder, not a complete orderable contact suffix. Confirm the complete mating-housing/contact variant, wire size and crimp tooling with the connector supplier before ordering. The catalogue does not specify an included harness quantity, a complete contact suffix or an accessory-kit order code; no inclusion is implied by the drawing. Dimensions, Mounting and Weight Body dimensions Case 995A; 218 × 105 × 41 mm (L × W × H), general drawing tolerance ±1 mm. Threaded mounting points The base drawing marks 4-M4 L=5, with 152.4 × 63.5 mm hole spacing. The side drawing marks 8-M4 L=4 across both sides. Follow the shown hole coordinates and the stated L limits. Terminal and service clearance The AC input-terminal projection is 12 mm maximum; the DC output-terminal projection is 18 mm maximum. Leave access to the terminals, CN100 and SVR, and keep the fan airflow path clear. Local indication / adjustment LED and output-voltage adjustment SVR are identified on the mechanical drawing. Catalogue unit weight 1190 g (1.19 kg), catalogue packing reference per unit from the PACKING row; not a measured net or shipping weight. Packing reference 12 pieces / 15.3 kg / 0.81 CUFT. This bulk packing reference is not the quantity supplied with an individual product. Use the complete dimension drawing on PDF page 11 for hole placement, connector orientation and installation envelope. The threaded-hole L markings must be respected; the diagram does not establish included screw quantities or tightening torques. Environment, EMC and Reliability Humidity / storage Operating humidity 20–90% RH, non-condensing. Storage −40°C to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5G, 10 minutes per cycle, 60 minutes along each X, Y and Z axis. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN60601-1-2; EAC TP TC020. EMC test arrangement The catalogue EMC tests mount the supply on a 360 × 360 mm metal plate, 1 mm thick. The completed equipment must be reconfirmed against the applicable EMC requirements. MTBF reference 159.3 K hours minimum, MIL-HDBK-217F at 25°C. These are reliability estimates, not a guaranteed operating life. Switching reference PWM oscillator frequency: 70 kHz, as shown in the block diagram. Manufacturer warranty statement The manufacturer catalogue lists a five-year warranty; applicable manufacturer terms govern.

    $385.41

  • MSP-450-36

    MEAN WELL MSP-450 series: Enclosed Medical AC/DC Power Supply - MSP-450-36

    MEAN WELL MSP-450-36 is a single-output enclosed medical-type AC/DC power supply rated 36 VDC, 12.5 A and 450 W. It combines active PFC, MOOP-level isolation, controlled fan cooling, remote sense, remote ON/OFF, a DC-OK signal and a separate 5 V standby output. Apply the model-specific input, leakage and derating limits below. Product Datasheet Download MEAN WELL MSP-450 Datasheet (PDF) The MSP-450 section is on PDF pages 10, 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Exact Model and Output Ratings Complete model MSP-450-36: MSP-450 single-output enclosed medical-type AC/DC power supply; -36 identifies the nominal 36 VDC output. Catalogue revision 2025-12-05. Rated output 36 VDC; 12.5 A; 450 W. Current range: 0–12.5 A. These are the exact model ratings, subject to the derating limits below. Output voltage adjustment 28.8–39.6 V using SVR. Observe the rated current and rated power limits when adjusting output voltage. Ripple and noise 240 mVp-p maximum; measured with 20 MHz bandwidth, a 12-inch twisted pair and 0.1 µF + 47 µF parallel capacitors. Voltage accuracy Voltage tolerance ±1.0%; line regulation ±0.2%; load regulation ±0.5%. Tolerance includes setup, line and load regulation. Typical efficiency 89%, at the catalogue default test conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. The family name is not a substitute for this exact model’s output rating. Input and Timing Normal input range 85–264 VAC or 120–370 VDC; AC frequency 47–63 Hz. Apply low-input derating. Active PFC Typical PF >0.95 at 230 VAC and >0.99 at 115 VAC, both at full load. Typical AC current 5 A at 115 VAC; 2.4 A at 230 VAC. Inrush / surge withstand Typical inrush 35 A at 115 VAC and 70 A at 230 VAC. Active inrush-current limiting is shown in the block diagram. Withstands 300 VAC surge input for 5 seconds; 300 VAC is not the continuous input rating. Setup / rise time 1000 ms / 100 ms at 230 VAC; 2500 ms / 100 ms at 115 VAC, at full load. Hold-up time 16 ms typical at 230 VAC and 16 ms typical at 115 VAC, at full load. No-load consumption The feature list states no-load input power below 0.6 W. Note 6 specifies below 0.5 W with the main output remotely OFF: RC+ to RC− at 0–0.8 V or shorted. Setup time is measured at the first cold start. Repeated ON/OFF switching may increase setup time. Below 40 VAC, the catalogue warns of possible performance degradation and requires the final-equipment manufacturer to reconfirm basic safety and essential performance. This is an abnormal low-input condition, not an extension of the normal 85–264 VAC operating range. Medical Isolation, Leakage and Approval Scope Medical isolation level Primary-to-secondary: 2 × MOOP; primary-to-earth: 1 × MOOP. Secondary-to-earth: 1 × MOOP. MOOP stands for means of operator protection. Leakage at 264 VAC Earth leakage <300 µA; touch leakage <100 µA. Listed safety approvals IEC60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Design references by request BS EN/EN60335-1 and BS EN/EN62368-1 are listed as design references, by request. Withstand voltage Input-to-output: 4 kVAC; input-to-FG: 2 kVAC; output-to-FG: 0.5 kVAC. Insulation resistance 100 MΩ minimum for input/output, input/FG and output/FG, tested at 500 VDC, 25°C and 70% RH. The stated insulation classification is MOOP. These pages do not establish a MOPP patient-protection rating or certify the completed medical equipment. Match the required insulation, leakage, grounding and final-system safety evaluation to the intended application. Protection and Cooling Short circuit / overload Short-circuit protection is listed. Overload threshold: 105–135% of rated output power, using constant-current limiting; automatic recovery after the fault is removed. Overvoltage 41.4–48.6 V threshold for this model; shuts down the output, with re-powering required to recover. Overtemperature Shuts down the output; automatic recovery after temperature falls. Controlled cooling fan Built-in fan ON/OFF control: fan turns on at a typical load threshold of 20 ±10%, or when internal thermistor RTH2 reaches at least 50°C. RTH2 is not the ambient-temperature rating. Ambient derating Horizontal mounting: 100% load from −40°C to +50°C, decreasing linearly to 50% at +70°C. The operating range is −40°C to +70°C, subject to this curve. Input-voltage derating At 60 Hz, the curve rises from 80% load at 85 VAC to 100% at 100 VAC, then remains at 100% through 264 VAC. Altitude derating For this fan-cooled model, reduce the allowed ambient temperature by 5°C per additional 1000 m above 2000 m. Apply input-voltage, temperature and output-rating limits together. Keep the indicated fan inlet/outlet and surrounding airflow path unobstructed; verify cooling in the final enclosure. No numerical mounting-clearance distance is specified in these catalogue pages. Standby, Remote Control and DC OK Standby output 5 V, 0.3 A maximum; tolerance ±5% (4.75–5.25 V), ripple 50 mVp-p maximum. AUX is not switched by the main-output remote ON/OFF control. Standby reference AUX pin 3 returns to AUXG pin 4. AUXG is isolated from the main +V/−V terminals; do not substitute the DC-OK ground. Remote ON/OFF Between RC+ pin 1 and RC− pin 2: 4–10 V or open contact = power ON; 0–0.8 V or short contact = power OFF. DC-OK signal DC-OK pin 5 is referenced to GND pin 6, which connects to main −V. TTL high when the PSU is ON: 3.3–5.6 V; OFF: 0–1 V. Remote sense Connect +S pin 7 to the positive load terminal and −S pin 8 to the negative load terminal. Twist +S and −S together; maximum line-drop compensation is 0.5 V. Use the complete function and connection drawings on PDF page 12. DC-OK is a TTL status output, not a dry relay contact; no additional contact-current or sourcing-current rating is specified here. The documented functions for this family are standby, remote ON/OFF, DC OK and remote sense. No active current-sharing or parallel-unit count is specified for these models. Power Terminals and CN100 Pin Assignment AC input terminals 1 / 2 / 3 AC/L / AC/N / FG (frame ground), respectively. Separate DC output terminals 1–3 / 4–6 DC terminals 1–3: −V; DC terminals 4–6: +V. Use the separate AC and DC numbering shown in the drawing. CN100 pin 1 — RC+ Remote ON/OFF control input relative to RC− pin 2; an open contact enables the main output and a short disables it. CN100 pin 2 — RC- Remote-control ground. CN100 pin 3 — AUX 4.75–5.25 V auxiliary output, maximum 0.3 A, referenced to AUXG pin 4; remains available independently of remote ON/OFF control. CN100 pin 4 — AUXG Auxiliary return, isolated from the main +V and −V output terminals. CN100 pin 5 — DC-OK TTL status output referenced to GND pin 6; high when the PSU turns on. CN100 pin 6 — GND DC-OK signal return; connected to the main −V output. CN100 pin 7 — +S Positive remote-sense lead to the positive load terminal; use a twisted pair with −S. CN100 pin 8 — -S Negative remote-sense lead to the negative load terminal; use a twisted pair with +S. Pin numbers refer to the actual connector orientation shown on PDF page 11. Verify polarity and the separate return functions before wiring. Mating Connector and Installation Parts Board connector CN100: HRS DF11-8DP-2DS or equivalent, as printed in the catalogue. Mating housing HRS DF11-8DS or equivalent, as printed. Contact reference HRS DF11-**SC or equivalent. The asterisks are a contact-family placeholder, not a complete orderable contact suffix. Confirm the complete mating-housing/contact variant, wire size and crimp tooling with the connector supplier before ordering. The catalogue does not specify an included harness quantity, a complete contact suffix or an accessory-kit order code; no inclusion is implied by the drawing. Dimensions, Mounting and Weight Body dimensions Case 995A; 218 × 105 × 41 mm (L × W × H), general drawing tolerance ±1 mm. Threaded mounting points The base drawing marks 4-M4 L=5, with 152.4 × 63.5 mm hole spacing. The side drawing marks 8-M4 L=4 across both sides. Follow the shown hole coordinates and the stated L limits. Terminal and service clearance The AC input-terminal projection is 12 mm maximum; the DC output-terminal projection is 18 mm maximum. Leave access to the terminals, CN100 and SVR, and keep the fan airflow path clear. Local indication / adjustment LED and output-voltage adjustment SVR are identified on the mechanical drawing. Catalogue unit weight 1190 g (1.19 kg), catalogue packing reference per unit from the PACKING row; not a measured net or shipping weight. Packing reference 12 pieces / 15.3 kg / 0.81 CUFT. This bulk packing reference is not the quantity supplied with an individual product. Use the complete dimension drawing on PDF page 11 for hole placement, connector orientation and installation envelope. The threaded-hole L markings must be respected; the diagram does not establish included screw quantities or tightening torques. Environment, EMC and Reliability Humidity / storage Operating humidity 20–90% RH, non-condensing. Storage −40°C to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5G, 10 minutes per cycle, 60 minutes along each X, Y and Z axis. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN60601-1-2; EAC TP TC020. EMC test arrangement The catalogue EMC tests mount the supply on a 360 × 360 mm metal plate, 1 mm thick. The completed equipment must be reconfirmed against the applicable EMC requirements. MTBF reference 159.3 K hours minimum, MIL-HDBK-217F at 25°C. These are reliability estimates, not a guaranteed operating life. Switching reference PWM oscillator frequency: 70 kHz, as shown in the block diagram. Manufacturer warranty statement The manufacturer catalogue lists a five-year warranty; applicable manufacturer terms govern.

    $393.30

  • MSP-450-24

    MEAN WELL MSP-450 series: Enclosed Medical AC/DC Power Supply - MSP-450-24

    MEAN WELL MSP-450-24 is a single-output enclosed medical-type AC/DC power supply rated 24 VDC, 18.8 A and 451.2 W. It combines active PFC, MOOP-level isolation, controlled fan cooling, remote sense, remote ON/OFF, a DC-OK signal and a separate 5 V standby output. Apply the model-specific input, leakage and derating limits below. Product Datasheet Download MEAN WELL MSP-450 Datasheet (PDF) The MSP-450 section is on PDF pages 10, 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Exact Model and Output Ratings Complete model MSP-450-24: MSP-450 single-output enclosed medical-type AC/DC power supply; -24 identifies the nominal 24 VDC output. Catalogue revision 2025-12-05. Rated output 24 VDC; 18.8 A; 451.2 W. Current range: 0–18.8 A. These are the exact model ratings, subject to the derating limits below. Output voltage adjustment 21.6–28.8 V using SVR. Observe the rated current and rated power limits when adjusting output voltage. Ripple and noise 150 mVp-p maximum; measured with 20 MHz bandwidth, a 12-inch twisted pair and 0.1 µF + 47 µF parallel capacitors. Voltage accuracy Voltage tolerance ±1.0%; line regulation ±0.2%; load regulation ±0.5%. Tolerance includes setup, line and load regulation. Typical efficiency 88%, at the catalogue default test conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. The family name is not a substitute for this exact model’s output rating. Input and Timing Normal input range 85–264 VAC or 120–370 VDC; AC frequency 47–63 Hz. Apply low-input derating. Active PFC Typical PF >0.95 at 230 VAC and >0.99 at 115 VAC, both at full load. Typical AC current 5 A at 115 VAC; 2.4 A at 230 VAC. Inrush / surge withstand Typical inrush 35 A at 115 VAC and 70 A at 230 VAC. Active inrush-current limiting is shown in the block diagram. Withstands 300 VAC surge input for 5 seconds; 300 VAC is not the continuous input rating. Setup / rise time 1000 ms / 100 ms at 230 VAC; 2500 ms / 100 ms at 115 VAC, at full load. Hold-up time 16 ms typical at 230 VAC and 16 ms typical at 115 VAC, at full load. No-load consumption The feature list states no-load input power below 0.6 W. Note 6 specifies below 0.5 W with the main output remotely OFF: RC+ to RC− at 0–0.8 V or shorted. Setup time is measured at the first cold start. Repeated ON/OFF switching may increase setup time. Below 40 VAC, the catalogue warns of possible performance degradation and requires the final-equipment manufacturer to reconfirm basic safety and essential performance. This is an abnormal low-input condition, not an extension of the normal 85–264 VAC operating range. Medical Isolation, Leakage and Approval Scope Medical isolation level Primary-to-secondary: 2 × MOOP; primary-to-earth: 1 × MOOP. Secondary-to-earth: 1 × MOOP. MOOP stands for means of operator protection. Leakage at 264 VAC Earth leakage <300 µA; touch leakage <100 µA. Listed safety approvals IEC60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Design references by request BS EN/EN60335-1 and BS EN/EN62368-1 are listed as design references, by request. Withstand voltage Input-to-output: 4 kVAC; input-to-FG: 2 kVAC; output-to-FG: 0.5 kVAC. Insulation resistance 100 MΩ minimum for input/output, input/FG and output/FG, tested at 500 VDC, 25°C and 70% RH. The stated insulation classification is MOOP. These pages do not establish a MOPP patient-protection rating or certify the completed medical equipment. Match the required insulation, leakage, grounding and final-system safety evaluation to the intended application. Protection and Cooling Short circuit / overload Short-circuit protection is listed. Overload threshold: 105–135% of rated output power, using constant-current limiting; automatic recovery after the fault is removed. Overvoltage 30–34.8 V threshold for this model; shuts down the output, with re-powering required to recover. Overtemperature Shuts down the output; automatic recovery after temperature falls. Controlled cooling fan Built-in fan ON/OFF control: fan turns on at a typical load threshold of 20 ±10%, or when internal thermistor RTH2 reaches at least 50°C. RTH2 is not the ambient-temperature rating. Ambient derating Horizontal mounting: 100% load from −40°C to +50°C, decreasing linearly to 50% at +70°C. The operating range is −40°C to +70°C, subject to this curve. Input-voltage derating At 60 Hz, the curve rises from 80% load at 85 VAC to 100% at 100 VAC, then remains at 100% through 264 VAC. Altitude derating For this fan-cooled model, reduce the allowed ambient temperature by 5°C per additional 1000 m above 2000 m. Apply input-voltage, temperature and output-rating limits together. Keep the indicated fan inlet/outlet and surrounding airflow path unobstructed; verify cooling in the final enclosure. No numerical mounting-clearance distance is specified in these catalogue pages. Standby, Remote Control and DC OK Standby output 5 V, 0.3 A maximum; tolerance ±5% (4.75–5.25 V), ripple 50 mVp-p maximum. AUX is not switched by the main-output remote ON/OFF control. Standby reference AUX pin 3 returns to AUXG pin 4. AUXG is isolated from the main +V/−V terminals; do not substitute the DC-OK ground. Remote ON/OFF Between RC+ pin 1 and RC− pin 2: 4–10 V or open contact = power ON; 0–0.8 V or short contact = power OFF. DC-OK signal DC-OK pin 5 is referenced to GND pin 6, which connects to main −V. TTL high when the PSU is ON: 3.3–5.6 V; OFF: 0–1 V. Remote sense Connect +S pin 7 to the positive load terminal and −S pin 8 to the negative load terminal. Twist +S and −S together; maximum line-drop compensation is 0.5 V. Use the complete function and connection drawings on PDF page 12. DC-OK is a TTL status output, not a dry relay contact; no additional contact-current or sourcing-current rating is specified here. The documented functions for this family are standby, remote ON/OFF, DC OK and remote sense. No active current-sharing or parallel-unit count is specified for these models. Power Terminals and CN100 Pin Assignment AC input terminals 1 / 2 / 3 AC/L / AC/N / FG (frame ground), respectively. Separate DC output terminals 1–3 / 4–6 DC terminals 1–3: −V; DC terminals 4–6: +V. Use the separate AC and DC numbering shown in the drawing. CN100 pin 1 — RC+ Remote ON/OFF control input relative to RC− pin 2; an open contact enables the main output and a short disables it. CN100 pin 2 — RC- Remote-control ground. CN100 pin 3 — AUX 4.75–5.25 V auxiliary output, maximum 0.3 A, referenced to AUXG pin 4; remains available independently of remote ON/OFF control. CN100 pin 4 — AUXG Auxiliary return, isolated from the main +V and −V output terminals. CN100 pin 5 — DC-OK TTL status output referenced to GND pin 6; high when the PSU turns on. CN100 pin 6 — GND DC-OK signal return; connected to the main −V output. CN100 pin 7 — +S Positive remote-sense lead to the positive load terminal; use a twisted pair with −S. CN100 pin 8 — -S Negative remote-sense lead to the negative load terminal; use a twisted pair with +S. Pin numbers refer to the actual connector orientation shown on PDF page 11. Verify polarity and the separate return functions before wiring. Mating Connector and Installation Parts Board connector CN100: HRS DF11-8DP-2DS or equivalent, as printed in the catalogue. Mating housing HRS DF11-8DS or equivalent, as printed. Contact reference HRS DF11-**SC or equivalent. The asterisks are a contact-family placeholder, not a complete orderable contact suffix. Confirm the complete mating-housing/contact variant, wire size and crimp tooling with the connector supplier before ordering. The catalogue does not specify an included harness quantity, a complete contact suffix or an accessory-kit order code; no inclusion is implied by the drawing. Dimensions, Mounting and Weight Body dimensions Case 995A; 218 × 105 × 41 mm (L × W × H), general drawing tolerance ±1 mm. Threaded mounting points The base drawing marks 4-M4 L=5, with 152.4 × 63.5 mm hole spacing. The side drawing marks 8-M4 L=4 across both sides. Follow the shown hole coordinates and the stated L limits. Terminal and service clearance The AC input-terminal projection is 12 mm maximum; the DC output-terminal projection is 18 mm maximum. Leave access to the terminals, CN100 and SVR, and keep the fan airflow path clear. Local indication / adjustment LED and output-voltage adjustment SVR are identified on the mechanical drawing. Catalogue unit weight 1190 g (1.19 kg), catalogue packing reference per unit from the PACKING row; not a measured net or shipping weight. Packing reference 12 pieces / 15.3 kg / 0.81 CUFT. This bulk packing reference is not the quantity supplied with an individual product. Use the complete dimension drawing on PDF page 11 for hole placement, connector orientation and installation envelope. The threaded-hole L markings must be respected; the diagram does not establish included screw quantities or tightening torques. Environment, EMC and Reliability Humidity / storage Operating humidity 20–90% RH, non-condensing. Storage −40°C to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5G, 10 minutes per cycle, 60 minutes along each X, Y and Z axis. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN60601-1-2; EAC TP TC020. EMC test arrangement The catalogue EMC tests mount the supply on a 360 × 360 mm metal plate, 1 mm thick. The completed equipment must be reconfirmed against the applicable EMC requirements. MTBF reference 159.3 K hours minimum, MIL-HDBK-217F at 25°C. These are reliability estimates, not a guaranteed operating life. Switching reference PWM oscillator frequency: 70 kHz, as shown in the block diagram. Manufacturer warranty statement The manufacturer catalogue lists a five-year warranty; applicable manufacturer terms govern.

    $385.41

  • MSP-450-15

    MEAN WELL MSP-450 series: Enclosed Medical AC/DC Power Supply - MSP-450-15

    MEAN WELL MSP-450-15 is a single-output enclosed medical-type AC/DC power supply rated 15 VDC, 30 A and 450 W. It combines active PFC, MOOP-level isolation, controlled fan cooling, remote sense, remote ON/OFF, a DC-OK signal and a separate 5 V standby output. Apply the model-specific input, leakage and derating limits below. Product Datasheet Download MEAN WELL MSP-450 Datasheet (PDF) The MSP-450 section is on PDF pages 10, 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Exact Model and Output Ratings Complete model MSP-450-15: MSP-450 single-output enclosed medical-type AC/DC power supply; -15 identifies the nominal 15 VDC output. Catalogue revision 2025-12-05. Rated output 15 VDC; 30 A; 450 W. Current range: 0–30 A. These are the exact model ratings, subject to the derating limits below. Output voltage adjustment 13.5–18 V using SVR. Observe the rated current and rated power limits when adjusting output voltage. Ripple and noise 150 mVp-p maximum; measured with 20 MHz bandwidth, a 12-inch twisted pair and 0.1 µF + 47 µF parallel capacitors. Voltage accuracy Voltage tolerance ±1.0%; line regulation ±0.3%; load regulation ±0.5%. Tolerance includes setup, line and load regulation. Typical efficiency 89%, at the catalogue default test conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. The family name is not a substitute for this exact model’s output rating. Input and Timing Normal input range 85–264 VAC or 120–370 VDC; AC frequency 47–63 Hz. Apply low-input derating. Active PFC Typical PF >0.95 at 230 VAC and >0.99 at 115 VAC, both at full load. Typical AC current 5 A at 115 VAC; 2.4 A at 230 VAC. Inrush / surge withstand Typical inrush 35 A at 115 VAC and 70 A at 230 VAC. Active inrush-current limiting is shown in the block diagram. Withstands 300 VAC surge input for 5 seconds; 300 VAC is not the continuous input rating. Setup / rise time 1000 ms / 100 ms at 230 VAC; 2500 ms / 100 ms at 115 VAC, at full load. Hold-up time 16 ms typical at 230 VAC and 16 ms typical at 115 VAC, at full load. No-load consumption The feature list states no-load input power below 0.6 W. Note 6 specifies below 0.5 W with the main output remotely OFF: RC+ to RC− at 0–0.8 V or shorted. Setup time is measured at the first cold start. Repeated ON/OFF switching may increase setup time. Below 40 VAC, the catalogue warns of possible performance degradation and requires the final-equipment manufacturer to reconfirm basic safety and essential performance. This is an abnormal low-input condition, not an extension of the normal 85–264 VAC operating range. Medical Isolation, Leakage and Approval Scope Medical isolation level Primary-to-secondary: 2 × MOOP; primary-to-earth: 1 × MOOP. Secondary-to-earth: 1 × MOOP. MOOP stands for means of operator protection. Leakage at 264 VAC Earth leakage <300 µA; touch leakage <100 µA. Listed safety approvals IEC60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Design references by request BS EN/EN60335-1 and BS EN/EN62368-1 are listed as design references, by request. Withstand voltage Input-to-output: 4 kVAC; input-to-FG: 2 kVAC; output-to-FG: 0.5 kVAC. Insulation resistance 100 MΩ minimum for input/output, input/FG and output/FG, tested at 500 VDC, 25°C and 70% RH. The stated insulation classification is MOOP. These pages do not establish a MOPP patient-protection rating or certify the completed medical equipment. Match the required insulation, leakage, grounding and final-system safety evaluation to the intended application. Protection and Cooling Short circuit / overload Short-circuit protection is listed. Overload threshold: 105–135% of rated output power, using constant-current limiting; automatic recovery after the fault is removed. Overvoltage 18.8–21.8 V threshold for this model; shuts down the output, with re-powering required to recover. Overtemperature Shuts down the output; automatic recovery after temperature falls. Controlled cooling fan Built-in fan ON/OFF control: fan turns on at a typical load threshold of 20 ±10%, or when internal thermistor RTH2 reaches at least 50°C. RTH2 is not the ambient-temperature rating. Ambient derating Horizontal mounting: 100% load from −40°C to +50°C, decreasing linearly to 50% at +70°C. The operating range is −40°C to +70°C, subject to this curve. Input-voltage derating At 60 Hz, the curve rises from 80% load at 85 VAC to 100% at 100 VAC, then remains at 100% through 264 VAC. Altitude derating For this fan-cooled model, reduce the allowed ambient temperature by 5°C per additional 1000 m above 2000 m. Apply input-voltage, temperature and output-rating limits together. Keep the indicated fan inlet/outlet and surrounding airflow path unobstructed; verify cooling in the final enclosure. No numerical mounting-clearance distance is specified in these catalogue pages. Standby, Remote Control and DC OK Standby output 5 V, 0.3 A maximum; tolerance ±5% (4.75–5.25 V), ripple 50 mVp-p maximum. AUX is not switched by the main-output remote ON/OFF control. Standby reference AUX pin 3 returns to AUXG pin 4. AUXG is isolated from the main +V/−V terminals; do not substitute the DC-OK ground. Remote ON/OFF Between RC+ pin 1 and RC− pin 2: 4–10 V or open contact = power ON; 0–0.8 V or short contact = power OFF. DC-OK signal DC-OK pin 5 is referenced to GND pin 6, which connects to main −V. TTL high when the PSU is ON: 3.3–5.6 V; OFF: 0–1 V. Remote sense Connect +S pin 7 to the positive load terminal and −S pin 8 to the negative load terminal. Twist +S and −S together; maximum line-drop compensation is 0.5 V. Use the complete function and connection drawings on PDF page 12. DC-OK is a TTL status output, not a dry relay contact; no additional contact-current or sourcing-current rating is specified here. The documented functions for this family are standby, remote ON/OFF, DC OK and remote sense. No active current-sharing or parallel-unit count is specified for these models. Power Terminals and CN100 Pin Assignment AC input terminals 1 / 2 / 3 AC/L / AC/N / FG (frame ground), respectively. Separate DC output terminals 1–3 / 4–6 DC terminals 1–3: −V; DC terminals 4–6: +V. Use the separate AC and DC numbering shown in the drawing. CN100 pin 1 — RC+ Remote ON/OFF control input relative to RC− pin 2; an open contact enables the main output and a short disables it. CN100 pin 2 — RC- Remote-control ground. CN100 pin 3 — AUX 4.75–5.25 V auxiliary output, maximum 0.3 A, referenced to AUXG pin 4; remains available independently of remote ON/OFF control. CN100 pin 4 — AUXG Auxiliary return, isolated from the main +V and −V output terminals. CN100 pin 5 — DC-OK TTL status output referenced to GND pin 6; high when the PSU turns on. CN100 pin 6 — GND DC-OK signal return; connected to the main −V output. CN100 pin 7 — +S Positive remote-sense lead to the positive load terminal; use a twisted pair with −S. CN100 pin 8 — -S Negative remote-sense lead to the negative load terminal; use a twisted pair with +S. Pin numbers refer to the actual connector orientation shown on PDF page 11. Verify polarity and the separate return functions before wiring. Mating Connector and Installation Parts Board connector CN100: HRS DF11-8DP-2DS or equivalent, as printed in the catalogue. Mating housing HRS DF11-8DS or equivalent, as printed. Contact reference HRS DF11-**SC or equivalent. The asterisks are a contact-family placeholder, not a complete orderable contact suffix. Confirm the complete mating-housing/contact variant, wire size and crimp tooling with the connector supplier before ordering. The catalogue does not specify an included harness quantity, a complete contact suffix or an accessory-kit order code; no inclusion is implied by the drawing. Dimensions, Mounting and Weight Body dimensions Case 995A; 218 × 105 × 41 mm (L × W × H), general drawing tolerance ±1 mm. Threaded mounting points The base drawing marks 4-M4 L=5, with 152.4 × 63.5 mm hole spacing. The side drawing marks 8-M4 L=4 across both sides. Follow the shown hole coordinates and the stated L limits. Terminal and service clearance The AC input-terminal projection is 12 mm maximum; the DC output-terminal projection is 18 mm maximum. Leave access to the terminals, CN100 and SVR, and keep the fan airflow path clear. Local indication / adjustment LED and output-voltage adjustment SVR are identified on the mechanical drawing. Catalogue unit weight 1190 g (1.19 kg), catalogue packing reference per unit from the PACKING row; not a measured net or shipping weight. Packing reference 12 pieces / 15.3 kg / 0.81 CUFT. This bulk packing reference is not the quantity supplied with an individual product. Use the complete dimension drawing on PDF page 11 for hole placement, connector orientation and installation envelope. The threaded-hole L markings must be respected; the diagram does not establish included screw quantities or tightening torques. Environment, EMC and Reliability Humidity / storage Operating humidity 20–90% RH, non-condensing. Storage −40°C to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5G, 10 minutes per cycle, 60 minutes along each X, Y and Z axis. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN60601-1-2; EAC TP TC020. EMC test arrangement The catalogue EMC tests mount the supply on a 360 × 360 mm metal plate, 1 mm thick. The completed equipment must be reconfirmed against the applicable EMC requirements. MTBF reference 159.3 K hours minimum, MIL-HDBK-217F at 25°C. These are reliability estimates, not a guaranteed operating life. Switching reference PWM oscillator frequency: 70 kHz, as shown in the block diagram. Manufacturer warranty statement The manufacturer catalogue lists a five-year warranty; applicable manufacturer terms govern.

    $385.41

  • MSP-450-12

    MEAN WELL MSP-450 series: Enclosed Medical AC/DC Power Supply - MSP-450-12

    MEAN WELL MSP-450-12 is a single-output enclosed medical-type AC/DC power supply rated 12 VDC, 37.5 A and 450 W. It combines active PFC, MOOP-level isolation, controlled fan cooling, remote sense, remote ON/OFF, a DC-OK signal and a separate 5 V standby output. Apply the model-specific input, leakage and derating limits below. Product Datasheet Download MEAN WELL MSP-450 Datasheet (PDF) The MSP-450 section is on PDF pages 10, 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Exact Model and Output Ratings Complete model MSP-450-12: MSP-450 single-output enclosed medical-type AC/DC power supply; -12 identifies the nominal 12 VDC output. Catalogue revision 2025-12-05. Rated output 12 VDC; 37.5 A; 450 W. Current range: 0–37.5 A. These are the exact model ratings, subject to the derating limits below. Output voltage adjustment 10.2–13.8 V using SVR. Observe the rated current and rated power limits when adjusting output voltage. Ripple and noise 120 mVp-p maximum; measured with 20 MHz bandwidth, a 12-inch twisted pair and 0.1 µF + 47 µF parallel capacitors. Voltage accuracy Voltage tolerance ±1.0%; line regulation ±0.3%; load regulation ±0.5%. Tolerance includes setup, line and load regulation. Typical efficiency 88%, at the catalogue default test conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. The family name is not a substitute for this exact model’s output rating. Input and Timing Normal input range 85–264 VAC or 120–370 VDC; AC frequency 47–63 Hz. Apply low-input derating. Active PFC Typical PF >0.95 at 230 VAC and >0.99 at 115 VAC, both at full load. Typical AC current 5 A at 115 VAC; 2.4 A at 230 VAC. Inrush / surge withstand Typical inrush 35 A at 115 VAC and 70 A at 230 VAC. Active inrush-current limiting is shown in the block diagram. Withstands 300 VAC surge input for 5 seconds; 300 VAC is not the continuous input rating. Setup / rise time 1000 ms / 100 ms at 230 VAC; 2500 ms / 100 ms at 115 VAC, at full load. Hold-up time 16 ms typical at 230 VAC and 16 ms typical at 115 VAC, at full load. No-load consumption The feature list states no-load input power below 0.6 W. Note 6 specifies below 0.5 W with the main output remotely OFF: RC+ to RC− at 0–0.8 V or shorted. Setup time is measured at the first cold start. Repeated ON/OFF switching may increase setup time. Below 40 VAC, the catalogue warns of possible performance degradation and requires the final-equipment manufacturer to reconfirm basic safety and essential performance. This is an abnormal low-input condition, not an extension of the normal 85–264 VAC operating range. Medical Isolation, Leakage and Approval Scope Medical isolation level Primary-to-secondary: 2 × MOOP; primary-to-earth: 1 × MOOP. Secondary-to-earth: 1 × MOOP. MOOP stands for means of operator protection. Leakage at 264 VAC Earth leakage <300 µA; touch leakage <100 µA. Listed safety approvals IEC60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Design references by request BS EN/EN60335-1 and BS EN/EN62368-1 are listed as design references, by request. Withstand voltage Input-to-output: 4 kVAC; input-to-FG: 2 kVAC; output-to-FG: 0.5 kVAC. Insulation resistance 100 MΩ minimum for input/output, input/FG and output/FG, tested at 500 VDC, 25°C and 70% RH. The stated insulation classification is MOOP. These pages do not establish a MOPP patient-protection rating or certify the completed medical equipment. Match the required insulation, leakage, grounding and final-system safety evaluation to the intended application. Protection and Cooling Short circuit / overload Short-circuit protection is listed. Overload threshold: 105–135% of rated output power, using constant-current limiting; automatic recovery after the fault is removed. Overvoltage 14.4–16.8 V threshold for this model; shuts down the output, with re-powering required to recover. Overtemperature Shuts down the output; automatic recovery after temperature falls. Controlled cooling fan Built-in fan ON/OFF control: fan turns on at a typical load threshold of 20 ±10%, or when internal thermistor RTH2 reaches at least 50°C. RTH2 is not the ambient-temperature rating. Ambient derating Horizontal mounting: 100% load from −40°C to +50°C, decreasing linearly to 50% at +70°C. The operating range is −40°C to +70°C, subject to this curve. Input-voltage derating At 60 Hz, the curve rises from 80% load at 85 VAC to 100% at 100 VAC, then remains at 100% through 264 VAC. Altitude derating For this fan-cooled model, reduce the allowed ambient temperature by 5°C per additional 1000 m above 2000 m. Apply input-voltage, temperature and output-rating limits together. Keep the indicated fan inlet/outlet and surrounding airflow path unobstructed; verify cooling in the final enclosure. No numerical mounting-clearance distance is specified in these catalogue pages. Standby, Remote Control and DC OK Standby output 5 V, 0.3 A maximum; tolerance ±5% (4.75–5.25 V), ripple 50 mVp-p maximum. AUX is not switched by the main-output remote ON/OFF control. Standby reference AUX pin 3 returns to AUXG pin 4. AUXG is isolated from the main +V/−V terminals; do not substitute the DC-OK ground. Remote ON/OFF Between RC+ pin 1 and RC− pin 2: 4–10 V or open contact = power ON; 0–0.8 V or short contact = power OFF. DC-OK signal DC-OK pin 5 is referenced to GND pin 6, which connects to main −V. TTL high when the PSU is ON: 3.3–5.6 V; OFF: 0–1 V. Remote sense Connect +S pin 7 to the positive load terminal and −S pin 8 to the negative load terminal. Twist +S and −S together; maximum line-drop compensation is 0.5 V. Use the complete function and connection drawings on PDF page 12. DC-OK is a TTL status output, not a dry relay contact; no additional contact-current or sourcing-current rating is specified here. The documented functions for this family are standby, remote ON/OFF, DC OK and remote sense. No active current-sharing or parallel-unit count is specified for these models. Power Terminals and CN100 Pin Assignment AC input terminals 1 / 2 / 3 AC/L / AC/N / FG (frame ground), respectively. Separate DC output terminals 1–3 / 4–6 DC terminals 1–3: −V; DC terminals 4–6: +V. Use the separate AC and DC numbering shown in the drawing. CN100 pin 1 — RC+ Remote ON/OFF control input relative to RC− pin 2; an open contact enables the main output and a short disables it. CN100 pin 2 — RC- Remote-control ground. CN100 pin 3 — AUX 4.75–5.25 V auxiliary output, maximum 0.3 A, referenced to AUXG pin 4; remains available independently of remote ON/OFF control. CN100 pin 4 — AUXG Auxiliary return, isolated from the main +V and −V output terminals. CN100 pin 5 — DC-OK TTL status output referenced to GND pin 6; high when the PSU turns on. CN100 pin 6 — GND DC-OK signal return; connected to the main −V output. CN100 pin 7 — +S Positive remote-sense lead to the positive load terminal; use a twisted pair with −S. CN100 pin 8 — -S Negative remote-sense lead to the negative load terminal; use a twisted pair with +S. Pin numbers refer to the actual connector orientation shown on PDF page 11. Verify polarity and the separate return functions before wiring. Mating Connector and Installation Parts Board connector CN100: HRS DF11-8DP-2DS or equivalent, as printed in the catalogue. Mating housing HRS DF11-8DS or equivalent, as printed. Contact reference HRS DF11-**SC or equivalent. The asterisks are a contact-family placeholder, not a complete orderable contact suffix. Confirm the complete mating-housing/contact variant, wire size and crimp tooling with the connector supplier before ordering. The catalogue does not specify an included harness quantity, a complete contact suffix or an accessory-kit order code; no inclusion is implied by the drawing. Dimensions, Mounting and Weight Body dimensions Case 995A; 218 × 105 × 41 mm (L × W × H), general drawing tolerance ±1 mm. Threaded mounting points The base drawing marks 4-M4 L=5, with 152.4 × 63.5 mm hole spacing. The side drawing marks 8-M4 L=4 across both sides. Follow the shown hole coordinates and the stated L limits. Terminal and service clearance The AC input-terminal projection is 12 mm maximum; the DC output-terminal projection is 18 mm maximum. Leave access to the terminals, CN100 and SVR, and keep the fan airflow path clear. Local indication / adjustment LED and output-voltage adjustment SVR are identified on the mechanical drawing. Catalogue unit weight 1190 g (1.19 kg), catalogue packing reference per unit from the PACKING row; not a measured net or shipping weight. Packing reference 12 pieces / 15.3 kg / 0.81 CUFT. This bulk packing reference is not the quantity supplied with an individual product. Use the complete dimension drawing on PDF page 11 for hole placement, connector orientation and installation envelope. The threaded-hole L markings must be respected; the diagram does not establish included screw quantities or tightening torques. Environment, EMC and Reliability Humidity / storage Operating humidity 20–90% RH, non-condensing. Storage −40°C to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5G, 10 minutes per cycle, 60 minutes along each X, Y and Z axis. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN60601-1-2; EAC TP TC020. EMC test arrangement The catalogue EMC tests mount the supply on a 360 × 360 mm metal plate, 1 mm thick. The completed equipment must be reconfirmed against the applicable EMC requirements. MTBF reference 159.3 K hours minimum, MIL-HDBK-217F at 25°C. These are reliability estimates, not a guaranteed operating life. Switching reference PWM oscillator frequency: 70 kHz, as shown in the block diagram. Manufacturer warranty statement The manufacturer catalogue lists a five-year warranty; applicable manufacturer terms govern.

    $393.30

  • MSP-450-7.5

    MEAN WELL MSP-450 series: Enclosed Medical AC/DC Power Supply - MSP-450-7.5

    MEAN WELL MSP-450-7.5 is a single-output enclosed medical-type AC/DC power supply rated 7.5 VDC, 60 A and 450 W. It combines active PFC, MOOP-level isolation, controlled fan cooling, remote sense, remote ON/OFF, a DC-OK signal and a separate 5 V standby output. Apply the model-specific input, leakage and derating limits below. Product Datasheet Download MEAN WELL MSP-450 Datasheet (PDF) The MSP-450 section is on PDF pages 10, 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Exact Model and Output Ratings Complete model MSP-450-7.5: MSP-450 single-output enclosed medical-type AC/DC power supply; -7.5 identifies the nominal 7.5 VDC output. Catalogue revision 2025-12-05. Rated output 7.5 VDC; 60 A; 450 W. Current range: 0–60 A. These are the exact model ratings, subject to the derating limits below. Output voltage adjustment 6.8–9 V using SVR. Observe the rated current and rated power limits when adjusting output voltage. Ripple and noise 100 mVp-p maximum; measured with 20 MHz bandwidth, a 12-inch twisted pair and 0.1 µF + 47 µF parallel capacitors. Voltage accuracy Voltage tolerance ±2.0%; line regulation ±0.5%; load regulation ±1.0%. Tolerance includes setup, line and load regulation. Typical efficiency 86.5%, at the catalogue default test conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. The family name is not a substitute for this exact model’s output rating. Input and Timing Normal input range 85–264 VAC or 120–370 VDC; AC frequency 47–63 Hz. Apply low-input derating. Active PFC Typical PF >0.95 at 230 VAC and >0.99 at 115 VAC, both at full load. Typical AC current 5 A at 115 VAC; 2.4 A at 230 VAC. Inrush / surge withstand Typical inrush 35 A at 115 VAC and 70 A at 230 VAC. Active inrush-current limiting is shown in the block diagram. Withstands 300 VAC surge input for 5 seconds; 300 VAC is not the continuous input rating. Setup / rise time 1000 ms / 100 ms at 230 VAC; 2500 ms / 100 ms at 115 VAC, at full load. Hold-up time 16 ms typical at 230 VAC and 16 ms typical at 115 VAC, at full load. No-load consumption The feature list states no-load input power below 0.6 W. Note 6 specifies below 0.5 W with the main output remotely OFF: RC+ to RC− at 0–0.8 V or shorted. Setup time is measured at the first cold start. Repeated ON/OFF switching may increase setup time. Below 40 VAC, the catalogue warns of possible performance degradation and requires the final-equipment manufacturer to reconfirm basic safety and essential performance. This is an abnormal low-input condition, not an extension of the normal 85–264 VAC operating range. Medical Isolation, Leakage and Approval Scope Medical isolation level Primary-to-secondary: 2 × MOOP; primary-to-earth: 1 × MOOP. Secondary-to-earth: 1 × MOOP. MOOP stands for means of operator protection. Leakage at 264 VAC Earth leakage <300 µA; touch leakage <100 µA. Listed safety approvals IEC60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Design references by request BS EN/EN60335-1 and BS EN/EN62368-1 are listed as design references, by request. Withstand voltage Input-to-output: 4 kVAC; input-to-FG: 2 kVAC; output-to-FG: 0.5 kVAC. Insulation resistance 100 MΩ minimum for input/output, input/FG and output/FG, tested at 500 VDC, 25°C and 70% RH. The stated insulation classification is MOOP. These pages do not establish a MOPP patient-protection rating or certify the completed medical equipment. Match the required insulation, leakage, grounding and final-system safety evaluation to the intended application. Protection and Cooling Short circuit / overload Short-circuit protection is listed. Overload threshold: 105–135% of rated output power, using constant-current limiting; automatic recovery after the fault is removed. Overvoltage 9.4–10.9 V threshold for this model; shuts down the output, with re-powering required to recover. Overtemperature Shuts down the output; automatic recovery after temperature falls. Controlled cooling fan Built-in fan ON/OFF control: fan turns on at a typical load threshold of 20 ±10%, or when internal thermistor RTH2 reaches at least 50°C. RTH2 is not the ambient-temperature rating. Ambient derating Horizontal mounting: 100% load from −40°C to +50°C, decreasing linearly to 50% at +70°C. The operating range is −40°C to +70°C, subject to this curve. Input-voltage derating At 60 Hz, the curve rises from 80% load at 85 VAC to 100% at 100 VAC, then remains at 100% through 264 VAC. Altitude derating For this fan-cooled model, reduce the allowed ambient temperature by 5°C per additional 1000 m above 2000 m. Apply input-voltage, temperature and output-rating limits together. Keep the indicated fan inlet/outlet and surrounding airflow path unobstructed; verify cooling in the final enclosure. No numerical mounting-clearance distance is specified in these catalogue pages. Standby, Remote Control and DC OK Standby output 5 V, 0.3 A maximum; tolerance ±5% (4.75–5.25 V), ripple 50 mVp-p maximum. AUX is not switched by the main-output remote ON/OFF control. Standby reference AUX pin 3 returns to AUXG pin 4. AUXG is isolated from the main +V/−V terminals; do not substitute the DC-OK ground. Remote ON/OFF Between RC+ pin 1 and RC− pin 2: 4–10 V or open contact = power ON; 0–0.8 V or short contact = power OFF. DC-OK signal DC-OK pin 5 is referenced to GND pin 6, which connects to main −V. TTL high when the PSU is ON: 3.3–5.6 V; OFF: 0–1 V. Remote sense Connect +S pin 7 to the positive load terminal and −S pin 8 to the negative load terminal. Twist +S and −S together; maximum line-drop compensation is 0.5 V. Use the complete function and connection drawings on PDF page 12. DC-OK is a TTL status output, not a dry relay contact; no additional contact-current or sourcing-current rating is specified here. The documented functions for this family are standby, remote ON/OFF, DC OK and remote sense. No active current-sharing or parallel-unit count is specified for these models. Power Terminals and CN100 Pin Assignment AC input terminals 1 / 2 / 3 AC/L / AC/N / FG (frame ground), respectively. Separate DC output terminals 1–3 / 4–6 DC terminals 1–3: −V; DC terminals 4–6: +V. Use the separate AC and DC numbering shown in the drawing. CN100 pin 1 — RC+ Remote ON/OFF control input relative to RC− pin 2; an open contact enables the main output and a short disables it. CN100 pin 2 — RC- Remote-control ground. CN100 pin 3 — AUX 4.75–5.25 V auxiliary output, maximum 0.3 A, referenced to AUXG pin 4; remains available independently of remote ON/OFF control. CN100 pin 4 — AUXG Auxiliary return, isolated from the main +V and −V output terminals. CN100 pin 5 — DC-OK TTL status output referenced to GND pin 6; high when the PSU turns on. CN100 pin 6 — GND DC-OK signal return; connected to the main −V output. CN100 pin 7 — +S Positive remote-sense lead to the positive load terminal; use a twisted pair with −S. CN100 pin 8 — -S Negative remote-sense lead to the negative load terminal; use a twisted pair with +S. Pin numbers refer to the actual connector orientation shown on PDF page 11. Verify polarity and the separate return functions before wiring. Mating Connector and Installation Parts Board connector CN100: HRS DF11-8DP-2DS or equivalent, as printed in the catalogue. Mating housing HRS DF11-8DS or equivalent, as printed. Contact reference HRS DF11-**SC or equivalent. The asterisks are a contact-family placeholder, not a complete orderable contact suffix. Confirm the complete mating-housing/contact variant, wire size and crimp tooling with the connector supplier before ordering. The catalogue does not specify an included harness quantity, a complete contact suffix or an accessory-kit order code; no inclusion is implied by the drawing. Dimensions, Mounting and Weight Body dimensions Case 995A; 218 × 105 × 41 mm (L × W × H), general drawing tolerance ±1 mm. Threaded mounting points The base drawing marks 4-M4 L=5, with 152.4 × 63.5 mm hole spacing. The side drawing marks 8-M4 L=4 across both sides. Follow the shown hole coordinates and the stated L limits. Terminal and service clearance The AC input-terminal projection is 12 mm maximum; the DC output-terminal projection is 18 mm maximum. Leave access to the terminals, CN100 and SVR, and keep the fan airflow path clear. Local indication / adjustment LED and output-voltage adjustment SVR are identified on the mechanical drawing. Catalogue unit weight 1190 g (1.19 kg), catalogue packing reference per unit from the PACKING row; not a measured net or shipping weight. Packing reference 12 pieces / 15.3 kg / 0.81 CUFT. This bulk packing reference is not the quantity supplied with an individual product. Use the complete dimension drawing on PDF page 11 for hole placement, connector orientation and installation envelope. The threaded-hole L markings must be respected; the diagram does not establish included screw quantities or tightening torques. Environment, EMC and Reliability Humidity / storage Operating humidity 20–90% RH, non-condensing. Storage −40°C to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5G, 10 minutes per cycle, 60 minutes along each X, Y and Z axis. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN60601-1-2; EAC TP TC020. EMC test arrangement The catalogue EMC tests mount the supply on a 360 × 360 mm metal plate, 1 mm thick. The completed equipment must be reconfirmed against the applicable EMC requirements. MTBF reference 159.3 K hours minimum, MIL-HDBK-217F at 25°C. These are reliability estimates, not a guaranteed operating life. Switching reference PWM oscillator frequency: 70 kHz, as shown in the block diagram. Manufacturer warranty statement The manufacturer catalogue lists a five-year warranty; applicable manufacturer terms govern.

    $393.30

  • MSP-450-5

    MEAN WELL MSP-450 series: Enclosed Medical AC/DC Power Supply - MSP-450-5

    MEAN WELL MSP-450-5 is a single-output enclosed medical-type AC/DC power supply rated 5 VDC, 90 A and 450 W. It combines active PFC, MOOP-level isolation, controlled fan cooling, remote sense, remote ON/OFF, a DC-OK signal and a separate 5 V standby output. Apply the model-specific input, leakage and derating limits below. Product Datasheet Download MEAN WELL MSP-450 Datasheet (PDF) The MSP-450 section is on PDF pages 10, 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Exact Model and Output Ratings Complete model MSP-450-5: MSP-450 single-output enclosed medical-type AC/DC power supply; -5 identifies the nominal 5 VDC output. Catalogue revision 2025-12-05. Rated output 5 VDC; 90 A; 450 W. Current range: 0–90 A. These are the exact model ratings, subject to the derating limits below. Output voltage adjustment 4.3–5.8 V using SVR. Observe the rated current and rated power limits when adjusting output voltage. Ripple and noise 80 mVp-p maximum; measured with 20 MHz bandwidth, a 12-inch twisted pair and 0.1 µF + 47 µF parallel capacitors. Voltage accuracy Voltage tolerance ±2.0%; line regulation ±0.5%; load regulation ±1.0%. Tolerance includes setup, line and load regulation. Typical efficiency 83%, at the catalogue default test conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. The family name is not a substitute for this exact model’s output rating. Input and Timing Normal input range 85–264 VAC or 120–370 VDC; AC frequency 47–63 Hz. Apply low-input derating. Active PFC Typical PF >0.95 at 230 VAC and >0.99 at 115 VAC, both at full load. Typical AC current 5 A at 115 VAC; 2.4 A at 230 VAC. Inrush / surge withstand Typical inrush 35 A at 115 VAC and 70 A at 230 VAC. Active inrush-current limiting is shown in the block diagram. Withstands 300 VAC surge input for 5 seconds; 300 VAC is not the continuous input rating. Setup / rise time 1000 ms / 100 ms at 230 VAC; 2500 ms / 100 ms at 115 VAC, at full load. Hold-up time 16 ms typical at 230 VAC and 16 ms typical at 115 VAC, at full load. No-load consumption The feature list states no-load input power below 0.6 W. Note 6 specifies below 0.5 W with the main output remotely OFF: RC+ to RC− at 0–0.8 V or shorted. Setup time is measured at the first cold start. Repeated ON/OFF switching may increase setup time. Below 40 VAC, the catalogue warns of possible performance degradation and requires the final-equipment manufacturer to reconfirm basic safety and essential performance. This is an abnormal low-input condition, not an extension of the normal 85–264 VAC operating range. Medical Isolation, Leakage and Approval Scope Medical isolation level Primary-to-secondary: 2 × MOOP; primary-to-earth: 1 × MOOP. Secondary-to-earth: 1 × MOOP. MOOP stands for means of operator protection. Leakage at 264 VAC Earth leakage <300 µA; touch leakage <100 µA. Listed safety approvals IEC60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Design references by request BS EN/EN60335-1 and BS EN/EN62368-1 are listed as design references, by request. Withstand voltage Input-to-output: 4 kVAC; input-to-FG: 2 kVAC; output-to-FG: 0.5 kVAC. Insulation resistance 100 MΩ minimum for input/output, input/FG and output/FG, tested at 500 VDC, 25°C and 70% RH. The stated insulation classification is MOOP. These pages do not establish a MOPP patient-protection rating or certify the completed medical equipment. Match the required insulation, leakage, grounding and final-system safety evaluation to the intended application. Protection and Cooling Short circuit / overload Short-circuit protection is listed. Overload threshold: 105–135% of rated output power, using constant-current limiting; automatic recovery after the fault is removed. Overvoltage 6–7 V threshold for this model; shuts down the output, with re-powering required to recover. Overtemperature Shuts down the output; automatic recovery after temperature falls. Controlled cooling fan Built-in fan ON/OFF control: fan turns on at a typical load threshold of 20 ±10%, or when internal thermistor RTH2 reaches at least 50°C. RTH2 is not the ambient-temperature rating. Ambient derating Horizontal mounting: 100% load from −40°C to +50°C, decreasing linearly to 50% at +70°C. The operating range is −40°C to +70°C, subject to this curve. Input-voltage derating At 60 Hz, the curve rises from 80% load at 85 VAC to 100% at 100 VAC, then remains at 100% through 264 VAC. Altitude derating For this fan-cooled model, reduce the allowed ambient temperature by 5°C per additional 1000 m above 2000 m. Apply input-voltage, temperature and output-rating limits together. Keep the indicated fan inlet/outlet and surrounding airflow path unobstructed; verify cooling in the final enclosure. No numerical mounting-clearance distance is specified in these catalogue pages. Standby, Remote Control and DC OK Standby output 5 V, 0.3 A maximum; tolerance ±5% (4.75–5.25 V), ripple 50 mVp-p maximum. AUX is not switched by the main-output remote ON/OFF control. Standby reference AUX pin 3 returns to AUXG pin 4. AUXG is isolated from the main +V/−V terminals; do not substitute the DC-OK ground. Remote ON/OFF Between RC+ pin 1 and RC− pin 2: 4–10 V or open contact = power ON; 0–0.8 V or short contact = power OFF. DC-OK signal DC-OK pin 5 is referenced to GND pin 6, which connects to main −V. TTL high when the PSU is ON: 3.3–5.6 V; OFF: 0–1 V. Remote sense Connect +S pin 7 to the positive load terminal and −S pin 8 to the negative load terminal. Twist +S and −S together; maximum line-drop compensation is 0.5 V. Use the complete function and connection drawings on PDF page 12. DC-OK is a TTL status output, not a dry relay contact; no additional contact-current or sourcing-current rating is specified here. The documented functions for this family are standby, remote ON/OFF, DC OK and remote sense. No active current-sharing or parallel-unit count is specified for these models. Power Terminals and CN100 Pin Assignment AC input terminals 1 / 2 / 3 AC/L / AC/N / FG (frame ground), respectively. Separate DC output terminals 1–3 / 4–6 DC terminals 1–3: −V; DC terminals 4–6: +V. Use the separate AC and DC numbering shown in the drawing. CN100 pin 1 — RC+ Remote ON/OFF control input relative to RC− pin 2; an open contact enables the main output and a short disables it. CN100 pin 2 — RC- Remote-control ground. CN100 pin 3 — AUX 4.75–5.25 V auxiliary output, maximum 0.3 A, referenced to AUXG pin 4; remains available independently of remote ON/OFF control. CN100 pin 4 — AUXG Auxiliary return, isolated from the main +V and −V output terminals. CN100 pin 5 — DC-OK TTL status output referenced to GND pin 6; high when the PSU turns on. CN100 pin 6 — GND DC-OK signal return; connected to the main −V output. CN100 pin 7 — +S Positive remote-sense lead to the positive load terminal; use a twisted pair with −S. CN100 pin 8 — -S Negative remote-sense lead to the negative load terminal; use a twisted pair with +S. Pin numbers refer to the actual connector orientation shown on PDF page 11. Verify polarity and the separate return functions before wiring. Mating Connector and Installation Parts Board connector CN100: HRS DF11-8DP-2DS or equivalent, as printed in the catalogue. Mating housing HRS DF11-8DS or equivalent, as printed. Contact reference HRS DF11-**SC or equivalent. The asterisks are a contact-family placeholder, not a complete orderable contact suffix. Confirm the complete mating-housing/contact variant, wire size and crimp tooling with the connector supplier before ordering. The catalogue does not specify an included harness quantity, a complete contact suffix or an accessory-kit order code; no inclusion is implied by the drawing. Dimensions, Mounting and Weight Body dimensions Case 995A; 218 × 105 × 41 mm (L × W × H), general drawing tolerance ±1 mm. Threaded mounting points The base drawing marks 4-M4 L=5, with 152.4 × 63.5 mm hole spacing. The side drawing marks 8-M4 L=4 across both sides. Follow the shown hole coordinates and the stated L limits. Terminal and service clearance The AC input-terminal projection is 12 mm maximum; the DC output-terminal projection is 18 mm maximum. Leave access to the terminals, CN100 and SVR, and keep the fan airflow path clear. Local indication / adjustment LED and output-voltage adjustment SVR are identified on the mechanical drawing. Catalogue unit weight 1190 g (1.19 kg), catalogue packing reference per unit from the PACKING row; not a measured net or shipping weight. Packing reference 12 pieces / 15.3 kg / 0.81 CUFT. This bulk packing reference is not the quantity supplied with an individual product. Use the complete dimension drawing on PDF page 11 for hole placement, connector orientation and installation envelope. The threaded-hole L markings must be respected; the diagram does not establish included screw quantities or tightening torques. Environment, EMC and Reliability Humidity / storage Operating humidity 20–90% RH, non-condensing. Storage −40°C to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5G, 10 minutes per cycle, 60 minutes along each X, Y and Z axis. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN60601-1-2; EAC TP TC020. EMC test arrangement The catalogue EMC tests mount the supply on a 360 × 360 mm metal plate, 1 mm thick. The completed equipment must be reconfirmed against the applicable EMC requirements. MTBF reference 159.3 K hours minimum, MIL-HDBK-217F at 25°C. These are reliability estimates, not a guaranteed operating life. Switching reference PWM oscillator frequency: 70 kHz, as shown in the block diagram. Manufacturer warranty statement The manufacturer catalogue lists a five-year warranty; applicable manufacturer terms govern.

    $385.41

  • MSP-450-3.3

    MEAN WELL MSP-450 series: Enclosed Medical AC/DC Power Supply - MSP-450-3.3

    MEAN WELL MSP-450-3.3 is a single-output enclosed medical-type AC/DC power supply rated 3.3 VDC, 90 A and 297 W. It combines active PFC, MOOP-level isolation, controlled fan cooling, remote sense, remote ON/OFF, a DC-OK signal and a separate 5 V standby output. Apply the model-specific input, leakage and derating limits below. Product Datasheet Download MEAN WELL MSP-450 Datasheet (PDF) The MSP-450 section is on PDF pages 10, 11, 12. Refer to the complete mechanical drawings and notes when planning installation. Exact Model and Output Ratings Complete model MSP-450-3.3: MSP-450 single-output enclosed medical-type AC/DC power supply; -3.3 identifies the nominal 3.3 VDC output. Catalogue revision 2025-12-05. Rated output 3.3 VDC; 90 A; 297 W. Current range: 0–90 A. These are the exact model ratings, subject to the derating limits below. Output voltage adjustment 2.8–3.8 V using SVR. Observe the rated current and rated power limits when adjusting output voltage. Ripple and noise 80 mVp-p maximum; measured with 20 MHz bandwidth, a 12-inch twisted pair and 0.1 µF + 47 µF parallel capacitors. Voltage accuracy Voltage tolerance ±2.0%; line regulation ±0.5%; load regulation ±1.0%. Tolerance includes setup, line and load regulation. Typical efficiency 80%, at the catalogue default test conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. The family name is not a substitute for this exact model’s output rating. Input and Timing Normal input range 85–264 VAC or 120–370 VDC; AC frequency 47–63 Hz. Apply low-input derating. Active PFC Typical PF >0.95 at 230 VAC and >0.99 at 115 VAC, both at full load. Typical AC current 5 A at 115 VAC; 2.4 A at 230 VAC. Inrush / surge withstand Typical inrush 35 A at 115 VAC and 70 A at 230 VAC. Active inrush-current limiting is shown in the block diagram. Withstands 300 VAC surge input for 5 seconds; 300 VAC is not the continuous input rating. Setup / rise time 1000 ms / 100 ms at 230 VAC; 2500 ms / 100 ms at 115 VAC, at full load. Hold-up time 16 ms typical at 230 VAC and 16 ms typical at 115 VAC, at full load. No-load consumption The feature list states no-load input power below 0.6 W. Note 6 specifies below 0.5 W with the main output remotely OFF: RC+ to RC− at 0–0.8 V or shorted. Setup time is measured at the first cold start. Repeated ON/OFF switching may increase setup time. Below 40 VAC, the catalogue warns of possible performance degradation and requires the final-equipment manufacturer to reconfirm basic safety and essential performance. This is an abnormal low-input condition, not an extension of the normal 85–264 VAC operating range. Medical Isolation, Leakage and Approval Scope Medical isolation level Primary-to-secondary: 2 × MOOP; primary-to-earth: 1 × MOOP. Secondary-to-earth: 1 × MOOP. MOOP stands for means of operator protection. Leakage at 264 VAC Earth leakage <300 µA; touch leakage <100 µA. Listed safety approvals IEC60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Design references by request BS EN/EN60335-1 and BS EN/EN62368-1 are listed as design references, by request. Withstand voltage Input-to-output: 4 kVAC; input-to-FG: 2 kVAC; output-to-FG: 0.5 kVAC. Insulation resistance 100 MΩ minimum for input/output, input/FG and output/FG, tested at 500 VDC, 25°C and 70% RH. The stated insulation classification is MOOP. These pages do not establish a MOPP patient-protection rating or certify the completed medical equipment. Match the required insulation, leakage, grounding and final-system safety evaluation to the intended application. Protection and Cooling Short circuit / overload Short-circuit protection is listed. Overload threshold: 105–135% of rated output power, using constant-current limiting; automatic recovery after the fault is removed. Overvoltage 3.96–4.62 V threshold for this model; shuts down the output, with re-powering required to recover. Overtemperature Shuts down the output; automatic recovery after temperature falls. Controlled cooling fan Built-in fan ON/OFF control: fan turns on at a typical load threshold of 20 ±10%, or when internal thermistor RTH2 reaches at least 50°C. RTH2 is not the ambient-temperature rating. Ambient derating Horizontal mounting: 100% load from −40°C to +50°C, decreasing linearly to 50% at +70°C. The operating range is −40°C to +70°C, subject to this curve. Input-voltage derating At 60 Hz, the curve rises from 80% load at 85 VAC to 100% at 100 VAC, then remains at 100% through 264 VAC. Altitude derating For this fan-cooled model, reduce the allowed ambient temperature by 5°C per additional 1000 m above 2000 m. Apply input-voltage, temperature and output-rating limits together. Keep the indicated fan inlet/outlet and surrounding airflow path unobstructed; verify cooling in the final enclosure. No numerical mounting-clearance distance is specified in these catalogue pages. Standby, Remote Control and DC OK Standby output 5 V, 0.3 A maximum; tolerance ±5% (4.75–5.25 V), ripple 50 mVp-p maximum. AUX is not switched by the main-output remote ON/OFF control. Standby reference AUX pin 3 returns to AUXG pin 4. AUXG is isolated from the main +V/−V terminals; do not substitute the DC-OK ground. Remote ON/OFF Between RC+ pin 1 and RC− pin 2: 4–10 V or open contact = power ON; 0–0.8 V or short contact = power OFF. DC-OK signal DC-OK pin 5 is referenced to GND pin 6, which connects to main −V. TTL high when the PSU is ON: 3.3–5.6 V; OFF: 0–1 V. Remote sense Connect +S pin 7 to the positive load terminal and −S pin 8 to the negative load terminal. Twist +S and −S together; maximum line-drop compensation is 0.5 V. Use the complete function and connection drawings on PDF page 12. DC-OK is a TTL status output, not a dry relay contact; no additional contact-current or sourcing-current rating is specified here. The documented functions for this family are standby, remote ON/OFF, DC OK and remote sense. No active current-sharing or parallel-unit count is specified for these models. Power Terminals and CN100 Pin Assignment AC input terminals 1 / 2 / 3 AC/L / AC/N / FG (frame ground), respectively. Separate DC output terminals 1–3 / 4–6 DC terminals 1–3: −V; DC terminals 4–6: +V. Use the separate AC and DC numbering shown in the drawing. CN100 pin 1 — RC+ Remote ON/OFF control input relative to RC− pin 2; an open contact enables the main output and a short disables it. CN100 pin 2 — RC- Remote-control ground. CN100 pin 3 — AUX 4.75–5.25 V auxiliary output, maximum 0.3 A, referenced to AUXG pin 4; remains available independently of remote ON/OFF control. CN100 pin 4 — AUXG Auxiliary return, isolated from the main +V and −V output terminals. CN100 pin 5 — DC-OK TTL status output referenced to GND pin 6; high when the PSU turns on. CN100 pin 6 — GND DC-OK signal return; connected to the main −V output. CN100 pin 7 — +S Positive remote-sense lead to the positive load terminal; use a twisted pair with −S. CN100 pin 8 — -S Negative remote-sense lead to the negative load terminal; use a twisted pair with +S. Pin numbers refer to the actual connector orientation shown on PDF page 11. Verify polarity and the separate return functions before wiring. Mating Connector and Installation Parts Board connector CN100: HRS DF11-8DP-2DS or equivalent, as printed in the catalogue. Mating housing HRS DF11-8DS or equivalent, as printed. Contact reference HRS DF11-**SC or equivalent. The asterisks are a contact-family placeholder, not a complete orderable contact suffix. Confirm the complete mating-housing/contact variant, wire size and crimp tooling with the connector supplier before ordering. The catalogue does not specify an included harness quantity, a complete contact suffix or an accessory-kit order code; no inclusion is implied by the drawing. Dimensions, Mounting and Weight Body dimensions Case 995A; 218 × 105 × 41 mm (L × W × H), general drawing tolerance ±1 mm. Threaded mounting points The base drawing marks 4-M4 L=5, with 152.4 × 63.5 mm hole spacing. The side drawing marks 8-M4 L=4 across both sides. Follow the shown hole coordinates and the stated L limits. Terminal and service clearance The AC input-terminal projection is 12 mm maximum; the DC output-terminal projection is 18 mm maximum. Leave access to the terminals, CN100 and SVR, and keep the fan airflow path clear. Local indication / adjustment LED and output-voltage adjustment SVR are identified on the mechanical drawing. Catalogue unit weight 1190 g (1.19 kg), catalogue packing reference per unit from the PACKING row; not a measured net or shipping weight. Packing reference 12 pieces / 15.3 kg / 0.81 CUFT. This bulk packing reference is not the quantity supplied with an individual product. Use the complete dimension drawing on PDF page 11 for hole placement, connector orientation and installation envelope. The threaded-hole L markings must be respected; the diagram does not establish included screw quantities or tightening torques. Environment, EMC and Reliability Humidity / storage Operating humidity 20–90% RH, non-condensing. Storage −40°C to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5G, 10 minutes per cycle, 60 minutes along each X, Y and Z axis. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN60601-1-2; EAC TP TC020. EMC test arrangement The catalogue EMC tests mount the supply on a 360 × 360 mm metal plate, 1 mm thick. The completed equipment must be reconfirmed against the applicable EMC requirements. MTBF reference 159.3 K hours minimum, MIL-HDBK-217F at 25°C. These are reliability estimates, not a guaranteed operating life. Switching reference PWM oscillator frequency: 70 kHz, as shown in the block diagram. Manufacturer warranty statement The manufacturer catalogue lists a five-year warranty; applicable manufacturer terms govern.

    $385.41

  • MSP-300-48

    MEAN WELL MSP-300 series: Enclosed Medical AC/DC Power Supply - MSP-300-48

    MEAN WELL MSP-300-48 is a single-output enclosed medical-type AC/DC power supply rated 48 VDC, 7 A and 336 W. It combines active PFC, MOOP-level isolation, controlled fan cooling, remote sense, remote ON/OFF, a DC-OK signal and a separate 5 V standby output. Apply the model-specific input, leakage and derating limits below. Product Datasheet Download MEAN WELL MSP-300 Datasheet (PDF) The MSP-300 section is on PDF pages 6, 7, 8, 9. Refer to the complete mechanical drawings and notes when planning installation. Exact Model and Output Ratings Complete model MSP-300-48: MSP-300 single-output enclosed medical-type AC/DC power supply; -48 identifies the nominal 48 VDC output. Catalogue revision 2026-02-09. Rated output 48 VDC; 7 A; 336 W. Current range: 0–7 A. These are the exact model ratings, subject to the derating limits below. Output voltage adjustment 40.8–55.2 V using SVR. Observe the rated current and rated power limits when adjusting output voltage. Ripple and noise 250 mVp-p maximum; measured with 20 MHz bandwidth, a 12-inch twisted pair and 0.1 µF + 47 µF parallel capacitors. Voltage accuracy Voltage tolerance ±1.0%; line regulation ±0.2%; load regulation ±0.5%. Tolerance includes setup, line and load regulation. Typical efficiency 89%, at the catalogue default test conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. The family name is not a substitute for this exact model’s output rating. Input and Timing Normal input range 85–264 VAC or 120–370 VDC; AC frequency 47–63 Hz. Apply low-input derating. Active PFC Typical PF >0.95 at 230 VAC and >0.99 at 115 VAC, both at full load. Typical AC current 4.5 A at 115 VAC; 2.25 A at 230 VAC. Inrush / surge withstand Typical inrush 35 A at 115 VAC and 70 A at 230 VAC. Active inrush-current limiting is shown in the block diagram. Withstands 300 VAC surge input for 5 seconds; 300 VAC is not the continuous input rating. Setup / rise time 1000 ms / 50 ms at 230 VAC; 2500 ms / 50 ms at 115 VAC, at full load. Hold-up time 16 ms typical at 230 VAC and 16 ms typical at 115 VAC, at full load. No-load consumption No-load input power below 0.5 W with the main output remotely OFF: RC+ to RC− at 0–0.8 V or shorted. Medical Isolation, Leakage and Approval Scope Medical isolation level Primary-to-secondary: 2 × MOOP; primary-to-earth: 1 × MOOP. MOOP stands for means of operator protection. Leakage at 264 VAC Earth leakage <450 µA; touch leakage <100 µA. Listed safety approvals IEC60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Design references by request BS EN/EN60335-1 and BS EN/EN62368-1 are listed as design references, by request. Withstand voltage Input-to-output: 4 kVAC; input-to-FG: 2 kVAC; output-to-FG: 0.5 kVAC. Insulation resistance 100 MΩ minimum for input/output, input/FG and output/FG, tested at 500 VDC, 25°C and 70% RH. The stated insulation classification is MOOP. These pages do not establish a MOPP patient-protection rating or certify the completed medical equipment. Match the required insulation, leakage, grounding and final-system safety evaluation to the intended application. Protection and Cooling Short circuit / overload Short-circuit protection is listed. Overload threshold: 105–135% of rated output power, using constant-current limiting; automatic recovery after the fault is removed. Overvoltage 57.6–67.2 V threshold for this model; shuts down the output, with re-powering required to recover. Overtemperature Shuts down the output; automatic recovery after temperature falls. Controlled cooling fan Built-in fan ON/OFF control: fan turns on at a typical load threshold of 35 ±15%, or when internal thermistor RTH2 reaches at least 50°C. RTH2 is not the ambient-temperature rating. Ambient derating Horizontal mounting: 100% load from −40°C to +50°C, decreasing linearly to 50% at +70°C. The operating range is −40°C to +70°C, subject to this curve. Input-voltage derating At 60 Hz, the curve rises from 80% load at 85 VAC to 100% at 100 VAC, then remains at 100% through 264 VAC. Altitude derating For this fan-cooled model, reduce the allowed ambient temperature by 5°C per additional 1000 m above 2000 m. Apply input-voltage, temperature and output-rating limits together. Keep the indicated fan inlet/outlet and surrounding airflow path unobstructed; verify cooling in the final enclosure. No numerical mounting-clearance distance is specified in these catalogue pages. Standby, Remote Control and DC OK Standby output 5 V, 0.3 A maximum; tolerance ±5% (4.75–5.25 V), ripple 50 mVp-p maximum. AUX is not switched by the main-output remote ON/OFF control. Standby reference AUX pin 1 returns to AUXG pin 2. AUXG is isolated from the main +V/−V terminals; do not substitute the DC-OK ground. Remote ON/OFF Between RC+ pin 6 and RC− pin 4: 4–10 V or open contact = power ON; 0–0.8 V or short contact = power OFF. DC-OK signal DC-OK pin 3 is referenced to GND pin 5, which connects to main −V. TTL high when the PSU is ON: 3.3–5.6 V; OFF: 0–1 V. Remote sense Connect +S pin 7 to the positive load terminal and −S pin 8 to the negative load terminal. Twist +S and −S together; maximum line-drop compensation is 0.5 V. Use the complete function and connection drawings on PDF pages 8–9. DC-OK is a TTL status output, not a dry relay contact; no additional contact-current or sourcing-current rating is specified here. The documented functions for this family are standby, remote ON/OFF, DC OK and remote sense. No active current-sharing or parallel-unit count is specified for these models. Power Terminals and CN100 Pin Assignment Power terminals 1 / 2 / 3 AC/L / AC/N / FG (frame ground), respectively. Power terminals 4–5 / 6–7 4 and 5: DC −V; 6 and 7: DC +V. CN100 pin 1 — AUX 4.75–5.25 V auxiliary output, maximum 0.3 A, referenced to AUXG pin 2; remains available independently of remote ON/OFF control. CN100 pin 2 — AUXG Auxiliary return, isolated from the main +V and −V output terminals. CN100 pin 3 — DC-OK TTL status output referenced to GND pin 5; high when the PSU turns on. CN100 pin 4 — RC- Remote-control ground. CN100 pin 5 — GND DC-OK signal return; connected to the main −V output. CN100 pin 6 — RC+ Remote ON/OFF control input relative to RC− pin 4; an open contact enables the main output and a short disables it. CN100 pin 7 — +S Positive remote-sense lead to the positive load terminal; use a twisted pair with −S. CN100 pin 8 — -S Negative remote-sense lead to the negative load terminal; use a twisted pair with +S. Pin numbers refer to the actual connector orientation shown on PDF page 7. Verify polarity and the separate return functions before wiring. Mating Connector and Installation Parts Board connector CN100: HRS DF11-8DP-2DS or equivalent, as printed in the catalogue. Mating housing HRS DF11-8DS or equivalent, as printed. Contact reference HRS DF11-**SC or equivalent. The asterisks are a contact-family placeholder, not a complete orderable contact suffix. Confirm the complete mating-housing/contact variant, wire size and crimp tooling with the connector supplier before ordering. The catalogue does not specify an included harness quantity, a complete contact suffix or an accessory-kit order code; no inclusion is implied by the drawing. Dimensions, Mounting and Weight Body dimensions Case 980A; 199 × 105 × 41 mm (L × W × H), general drawing tolerance ±1 mm. Threaded mounting points The base drawing marks 4-M4 L=5, with 120 × 75 mm hole spacing. Each side drawing marks 4-M4 L=6; the two side-view longitudinal spacings are 168.5 mm and 167.5 mm as drawn. Follow each view and datum separately. Terminal and service clearance The power-terminal projection is 17 mm maximum. The drawing shows a 125 mm overall mounting-ear width outside the 105 mm body. Leave access to the input/output terminals, CN100 and SVR, and keep the fan airflow path clear. Local indication / adjustment LED and output-voltage adjustment SVR are identified on the mechanical drawing. Catalogue unit weight 950 g (0.95 kg), catalogue packing reference per unit from the PACKING row; not a measured net or shipping weight. Packing reference 15 pieces / 15.3 kg / 0.83 CUFT. This bulk packing reference is not the quantity supplied with an individual product. Use the complete dimension drawing on PDF page 7 for hole placement, connector orientation and installation envelope. The threaded-hole L markings must be respected; the diagram does not establish included screw quantities or tightening torques. Environment, EMC and Reliability Humidity / storage Operating humidity 20–90% RH, non-condensing. Storage −40°C to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5G, 10 minutes per cycle, 60 minutes along each X, Y and Z axis. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55035; BS EN/EN60601-1-2; EAC TP TC020. EMC test arrangement The catalogue EMC tests mount the supply on a 360 × 360 mm metal plate, 1 mm thick. The completed equipment must be reconfirmed against the applicable EMC requirements. MTBF reference 1337.5 K hours minimum, Telcordia SR-332 (Bellcore); 175.8 K hours minimum, MIL-HDBK-217F at 25°C. These are reliability estimates, not a guaranteed operating life. Switching reference PWM oscillator frequency: 70 kHz, as shown in the block diagram. Manufacturer warranty statement The manufacturer catalogue lists a five-year warranty; applicable manufacturer terms govern.

    $276.99

  • MSP-300-36

    MEAN WELL MSP-300 series: Enclosed Medical AC/DC Power Supply - MSP-300-36

    MEAN WELL MSP-300-36 is a single-output enclosed medical-type AC/DC power supply rated 36 VDC, 9 A and 324 W. It combines active PFC, MOOP-level isolation, controlled fan cooling, remote sense, remote ON/OFF, a DC-OK signal and a separate 5 V standby output. Apply the model-specific input, leakage and derating limits below. Product Datasheet Download MEAN WELL MSP-300 Datasheet (PDF) The MSP-300 section is on PDF pages 6, 7, 8, 9. Refer to the complete mechanical drawings and notes when planning installation. Exact Model and Output Ratings Complete model MSP-300-36: MSP-300 single-output enclosed medical-type AC/DC power supply; -36 identifies the nominal 36 VDC output. Catalogue revision 2026-02-09. Rated output 36 VDC; 9 A; 324 W. Current range: 0–9 A. These are the exact model ratings, subject to the derating limits below. Output voltage adjustment 28.8–39.6 V using SVR. Observe the rated current and rated power limits when adjusting output voltage. Ripple and noise 250 mVp-p maximum; measured with 20 MHz bandwidth, a 12-inch twisted pair and 0.1 µF + 47 µF parallel capacitors. Voltage accuracy Voltage tolerance ±1.0%; line regulation ±0.2%; load regulation ±0.5%. Tolerance includes setup, line and load regulation. Typical efficiency 88%, at the catalogue default test conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. The family name is not a substitute for this exact model’s output rating. Input and Timing Normal input range 85–264 VAC or 120–370 VDC; AC frequency 47–63 Hz. Apply low-input derating. Active PFC Typical PF >0.95 at 230 VAC and >0.99 at 115 VAC, both at full load. Typical AC current 4.5 A at 115 VAC; 2.25 A at 230 VAC. Inrush / surge withstand Typical inrush 35 A at 115 VAC and 70 A at 230 VAC. Active inrush-current limiting is shown in the block diagram. Withstands 300 VAC surge input for 5 seconds; 300 VAC is not the continuous input rating. Setup / rise time 1000 ms / 50 ms at 230 VAC; 2500 ms / 50 ms at 115 VAC, at full load. Hold-up time 16 ms typical at 230 VAC and 16 ms typical at 115 VAC, at full load. No-load consumption No-load input power below 0.5 W with the main output remotely OFF: RC+ to RC− at 0–0.8 V or shorted. Medical Isolation, Leakage and Approval Scope Medical isolation level Primary-to-secondary: 2 × MOOP; primary-to-earth: 1 × MOOP. MOOP stands for means of operator protection. Leakage at 264 VAC Earth leakage <450 µA; touch leakage <100 µA. Listed safety approvals IEC60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Design references by request BS EN/EN60335-1 and BS EN/EN62368-1 are listed as design references, by request. Withstand voltage Input-to-output: 4 kVAC; input-to-FG: 2 kVAC; output-to-FG: 0.5 kVAC. Insulation resistance 100 MΩ minimum for input/output, input/FG and output/FG, tested at 500 VDC, 25°C and 70% RH. The stated insulation classification is MOOP. These pages do not establish a MOPP patient-protection rating or certify the completed medical equipment. Match the required insulation, leakage, grounding and final-system safety evaluation to the intended application. Protection and Cooling Short circuit / overload Short-circuit protection is listed. Overload threshold: 105–135% of rated output power, using constant-current limiting; automatic recovery after the fault is removed. Overvoltage 41.4–48.6 V threshold for this model; shuts down the output, with re-powering required to recover. Overtemperature Shuts down the output; automatic recovery after temperature falls. Controlled cooling fan Built-in fan ON/OFF control: fan turns on at a typical load threshold of 35 ±15%, or when internal thermistor RTH2 reaches at least 50°C. RTH2 is not the ambient-temperature rating. Ambient derating Horizontal mounting: 100% load from −40°C to +50°C, decreasing linearly to 50% at +70°C. The operating range is −40°C to +70°C, subject to this curve. Input-voltage derating At 60 Hz, the curve rises from 80% load at 85 VAC to 100% at 100 VAC, then remains at 100% through 264 VAC. Altitude derating For this fan-cooled model, reduce the allowed ambient temperature by 5°C per additional 1000 m above 2000 m. Apply input-voltage, temperature and output-rating limits together. Keep the indicated fan inlet/outlet and surrounding airflow path unobstructed; verify cooling in the final enclosure. No numerical mounting-clearance distance is specified in these catalogue pages. Standby, Remote Control and DC OK Standby output 5 V, 0.3 A maximum; tolerance ±5% (4.75–5.25 V), ripple 50 mVp-p maximum. AUX is not switched by the main-output remote ON/OFF control. Standby reference AUX pin 1 returns to AUXG pin 2. AUXG is isolated from the main +V/−V terminals; do not substitute the DC-OK ground. Remote ON/OFF Between RC+ pin 6 and RC− pin 4: 4–10 V or open contact = power ON; 0–0.8 V or short contact = power OFF. DC-OK signal DC-OK pin 3 is referenced to GND pin 5, which connects to main −V. TTL high when the PSU is ON: 3.3–5.6 V; OFF: 0–1 V. Remote sense Connect +S pin 7 to the positive load terminal and −S pin 8 to the negative load terminal. Twist +S and −S together; maximum line-drop compensation is 0.5 V. Use the complete function and connection drawings on PDF pages 8–9. DC-OK is a TTL status output, not a dry relay contact; no additional contact-current or sourcing-current rating is specified here. The documented functions for this family are standby, remote ON/OFF, DC OK and remote sense. No active current-sharing or parallel-unit count is specified for these models. Power Terminals and CN100 Pin Assignment Power terminals 1 / 2 / 3 AC/L / AC/N / FG (frame ground), respectively. Power terminals 4–5 / 6–7 4 and 5: DC −V; 6 and 7: DC +V. CN100 pin 1 — AUX 4.75–5.25 V auxiliary output, maximum 0.3 A, referenced to AUXG pin 2; remains available independently of remote ON/OFF control. CN100 pin 2 — AUXG Auxiliary return, isolated from the main +V and −V output terminals. CN100 pin 3 — DC-OK TTL status output referenced to GND pin 5; high when the PSU turns on. CN100 pin 4 — RC- Remote-control ground. CN100 pin 5 — GND DC-OK signal return; connected to the main −V output. CN100 pin 6 — RC+ Remote ON/OFF control input relative to RC− pin 4; an open contact enables the main output and a short disables it. CN100 pin 7 — +S Positive remote-sense lead to the positive load terminal; use a twisted pair with −S. CN100 pin 8 — -S Negative remote-sense lead to the negative load terminal; use a twisted pair with +S. Pin numbers refer to the actual connector orientation shown on PDF page 7. Verify polarity and the separate return functions before wiring. Mating Connector and Installation Parts Board connector CN100: HRS DF11-8DP-2DS or equivalent, as printed in the catalogue. Mating housing HRS DF11-8DS or equivalent, as printed. Contact reference HRS DF11-**SC or equivalent. The asterisks are a contact-family placeholder, not a complete orderable contact suffix. Confirm the complete mating-housing/contact variant, wire size and crimp tooling with the connector supplier before ordering. The catalogue does not specify an included harness quantity, a complete contact suffix or an accessory-kit order code; no inclusion is implied by the drawing. Dimensions, Mounting and Weight Body dimensions Case 980A; 199 × 105 × 41 mm (L × W × H), general drawing tolerance ±1 mm. Threaded mounting points The base drawing marks 4-M4 L=5, with 120 × 75 mm hole spacing. Each side drawing marks 4-M4 L=6; the two side-view longitudinal spacings are 168.5 mm and 167.5 mm as drawn. Follow each view and datum separately. Terminal and service clearance The power-terminal projection is 17 mm maximum. The drawing shows a 125 mm overall mounting-ear width outside the 105 mm body. Leave access to the input/output terminals, CN100 and SVR, and keep the fan airflow path clear. Local indication / adjustment LED and output-voltage adjustment SVR are identified on the mechanical drawing. Catalogue unit weight 950 g (0.95 kg), catalogue packing reference per unit from the PACKING row; not a measured net or shipping weight. Packing reference 15 pieces / 15.3 kg / 0.83 CUFT. This bulk packing reference is not the quantity supplied with an individual product. Use the complete dimension drawing on PDF page 7 for hole placement, connector orientation and installation envelope. The threaded-hole L markings must be respected; the diagram does not establish included screw quantities or tightening torques. Environment, EMC and Reliability Humidity / storage Operating humidity 20–90% RH, non-condensing. Storage −40°C to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5G, 10 minutes per cycle, 60 minutes along each X, Y and Z axis. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55035; BS EN/EN60601-1-2; EAC TP TC020. EMC test arrangement The catalogue EMC tests mount the supply on a 360 × 360 mm metal plate, 1 mm thick. The completed equipment must be reconfirmed against the applicable EMC requirements. MTBF reference 1337.5 K hours minimum, Telcordia SR-332 (Bellcore); 175.8 K hours minimum, MIL-HDBK-217F at 25°C. These are reliability estimates, not a guaranteed operating life. Switching reference PWM oscillator frequency: 70 kHz, as shown in the block diagram. Manufacturer warranty statement The manufacturer catalogue lists a five-year warranty; applicable manufacturer terms govern.

    $276.99

  • MSP-300-24

    MEAN WELL MSP-300 series: Enclosed Medical AC/DC Power Supply - MSP-300-24

    MEAN WELL MSP-300-24 is a single-output enclosed medical-type AC/DC power supply rated 24 VDC, 14 A and 336 W. It combines active PFC, MOOP-level isolation, controlled fan cooling, remote sense, remote ON/OFF, a DC-OK signal and a separate 5 V standby output. Apply the model-specific input, leakage and derating limits below. Product Datasheet Download MEAN WELL MSP-300 Datasheet (PDF) The MSP-300 section is on PDF pages 6, 7, 8, 9. Refer to the complete mechanical drawings and notes when planning installation. Exact Model and Output Ratings Complete model MSP-300-24: MSP-300 single-output enclosed medical-type AC/DC power supply; -24 identifies the nominal 24 VDC output. Catalogue revision 2026-02-09. Rated output 24 VDC; 14 A; 336 W. Current range: 0–14 A. These are the exact model ratings, subject to the derating limits below. Output voltage adjustment 21.6–28.8 V using SVR. Observe the rated current and rated power limits when adjusting output voltage. Ripple and noise 150 mVp-p maximum; measured with 20 MHz bandwidth, a 12-inch twisted pair and 0.1 µF + 47 µF parallel capacitors. Voltage accuracy Voltage tolerance ±1.0%; line regulation ±0.2%; load regulation ±0.5%. Tolerance includes setup, line and load regulation. Typical efficiency 87%, at the catalogue default test conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. The family name is not a substitute for this exact model’s output rating. Input and Timing Normal input range 85–264 VAC or 120–370 VDC; AC frequency 47–63 Hz. Apply low-input derating. Active PFC Typical PF >0.95 at 230 VAC and >0.99 at 115 VAC, both at full load. Typical AC current 4.5 A at 115 VAC; 2.25 A at 230 VAC. Inrush / surge withstand Typical inrush 35 A at 115 VAC and 70 A at 230 VAC. Active inrush-current limiting is shown in the block diagram. Withstands 300 VAC surge input for 5 seconds; 300 VAC is not the continuous input rating. Setup / rise time 1000 ms / 50 ms at 230 VAC; 2500 ms / 50 ms at 115 VAC, at full load. Hold-up time 16 ms typical at 230 VAC and 16 ms typical at 115 VAC, at full load. No-load consumption No-load input power below 0.5 W with the main output remotely OFF: RC+ to RC− at 0–0.8 V or shorted. Medical Isolation, Leakage and Approval Scope Medical isolation level Primary-to-secondary: 2 × MOOP; primary-to-earth: 1 × MOOP. MOOP stands for means of operator protection. Leakage at 264 VAC Earth leakage <450 µA; touch leakage <100 µA. Listed safety approvals IEC60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Design references by request BS EN/EN60335-1 and BS EN/EN62368-1 are listed as design references, by request. Withstand voltage Input-to-output: 4 kVAC; input-to-FG: 2 kVAC; output-to-FG: 0.5 kVAC. Insulation resistance 100 MΩ minimum for input/output, input/FG and output/FG, tested at 500 VDC, 25°C and 70% RH. The stated insulation classification is MOOP. These pages do not establish a MOPP patient-protection rating or certify the completed medical equipment. Match the required insulation, leakage, grounding and final-system safety evaluation to the intended application. Protection and Cooling Short circuit / overload Short-circuit protection is listed. Overload threshold: 105–135% of rated output power, using constant-current limiting; automatic recovery after the fault is removed. Overvoltage 30–34.8 V threshold for this model; shuts down the output, with re-powering required to recover. Overtemperature Shuts down the output; automatic recovery after temperature falls. Controlled cooling fan Built-in fan ON/OFF control: fan turns on at a typical load threshold of 35 ±15%, or when internal thermistor RTH2 reaches at least 50°C. RTH2 is not the ambient-temperature rating. Ambient derating Horizontal mounting: 100% load from −40°C to +50°C, decreasing linearly to 50% at +70°C. The operating range is −40°C to +70°C, subject to this curve. Input-voltage derating At 60 Hz, the curve rises from 80% load at 85 VAC to 100% at 100 VAC, then remains at 100% through 264 VAC. Altitude derating For this fan-cooled model, reduce the allowed ambient temperature by 5°C per additional 1000 m above 2000 m. Apply input-voltage, temperature and output-rating limits together. Keep the indicated fan inlet/outlet and surrounding airflow path unobstructed; verify cooling in the final enclosure. No numerical mounting-clearance distance is specified in these catalogue pages. Standby, Remote Control and DC OK Standby output 5 V, 0.3 A maximum; tolerance ±5% (4.75–5.25 V), ripple 50 mVp-p maximum. AUX is not switched by the main-output remote ON/OFF control. Standby reference AUX pin 1 returns to AUXG pin 2. AUXG is isolated from the main +V/−V terminals; do not substitute the DC-OK ground. Remote ON/OFF Between RC+ pin 6 and RC− pin 4: 4–10 V or open contact = power ON; 0–0.8 V or short contact = power OFF. DC-OK signal DC-OK pin 3 is referenced to GND pin 5, which connects to main −V. TTL high when the PSU is ON: 3.3–5.6 V; OFF: 0–1 V. Remote sense Connect +S pin 7 to the positive load terminal and −S pin 8 to the negative load terminal. Twist +S and −S together; maximum line-drop compensation is 0.5 V. Use the complete function and connection drawings on PDF pages 8–9. DC-OK is a TTL status output, not a dry relay contact; no additional contact-current or sourcing-current rating is specified here. The documented functions for this family are standby, remote ON/OFF, DC OK and remote sense. No active current-sharing or parallel-unit count is specified for these models. Power Terminals and CN100 Pin Assignment Power terminals 1 / 2 / 3 AC/L / AC/N / FG (frame ground), respectively. Power terminals 4–5 / 6–7 4 and 5: DC −V; 6 and 7: DC +V. CN100 pin 1 — AUX 4.75–5.25 V auxiliary output, maximum 0.3 A, referenced to AUXG pin 2; remains available independently of remote ON/OFF control. CN100 pin 2 — AUXG Auxiliary return, isolated from the main +V and −V output terminals. CN100 pin 3 — DC-OK TTL status output referenced to GND pin 5; high when the PSU turns on. CN100 pin 4 — RC- Remote-control ground. CN100 pin 5 — GND DC-OK signal return; connected to the main −V output. CN100 pin 6 — RC+ Remote ON/OFF control input relative to RC− pin 4; an open contact enables the main output and a short disables it. CN100 pin 7 — +S Positive remote-sense lead to the positive load terminal; use a twisted pair with −S. CN100 pin 8 — -S Negative remote-sense lead to the negative load terminal; use a twisted pair with +S. Pin numbers refer to the actual connector orientation shown on PDF page 7. Verify polarity and the separate return functions before wiring. Mating Connector and Installation Parts Board connector CN100: HRS DF11-8DP-2DS or equivalent, as printed in the catalogue. Mating housing HRS DF11-8DS or equivalent, as printed. Contact reference HRS DF11-**SC or equivalent. The asterisks are a contact-family placeholder, not a complete orderable contact suffix. Confirm the complete mating-housing/contact variant, wire size and crimp tooling with the connector supplier before ordering. The catalogue does not specify an included harness quantity, a complete contact suffix or an accessory-kit order code; no inclusion is implied by the drawing. Dimensions, Mounting and Weight Body dimensions Case 980A; 199 × 105 × 41 mm (L × W × H), general drawing tolerance ±1 mm. Threaded mounting points The base drawing marks 4-M4 L=5, with 120 × 75 mm hole spacing. Each side drawing marks 4-M4 L=6; the two side-view longitudinal spacings are 168.5 mm and 167.5 mm as drawn. Follow each view and datum separately. Terminal and service clearance The power-terminal projection is 17 mm maximum. The drawing shows a 125 mm overall mounting-ear width outside the 105 mm body. Leave access to the input/output terminals, CN100 and SVR, and keep the fan airflow path clear. Local indication / adjustment LED and output-voltage adjustment SVR are identified on the mechanical drawing. Catalogue unit weight 950 g (0.95 kg), catalogue packing reference per unit from the PACKING row; not a measured net or shipping weight. Packing reference 15 pieces / 15.3 kg / 0.83 CUFT. This bulk packing reference is not the quantity supplied with an individual product. Use the complete dimension drawing on PDF page 7 for hole placement, connector orientation and installation envelope. The threaded-hole L markings must be respected; the diagram does not establish included screw quantities or tightening torques. Environment, EMC and Reliability Humidity / storage Operating humidity 20–90% RH, non-condensing. Storage −40°C to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5G, 10 minutes per cycle, 60 minutes along each X, Y and Z axis. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55035; BS EN/EN60601-1-2; EAC TP TC020. EMC test arrangement The catalogue EMC tests mount the supply on a 360 × 360 mm metal plate, 1 mm thick. The completed equipment must be reconfirmed against the applicable EMC requirements. MTBF reference 1337.5 K hours minimum, Telcordia SR-332 (Bellcore); 175.8 K hours minimum, MIL-HDBK-217F at 25°C. These are reliability estimates, not a guaranteed operating life. Switching reference PWM oscillator frequency: 70 kHz, as shown in the block diagram. Manufacturer warranty statement The manufacturer catalogue lists a five-year warranty; applicable manufacturer terms govern.

    $276.99

  • MSP-300-15

    MEAN WELL MSP-300 series: Enclosed Medical AC/DC Power Supply - MSP-300-15

    MEAN WELL MSP-300-15 is a single-output enclosed medical-type AC/DC power supply rated 15 VDC, 22 A and 330 W. It combines active PFC, MOOP-level isolation, controlled fan cooling, remote sense, remote ON/OFF, a DC-OK signal and a separate 5 V standby output. Apply the model-specific input, leakage and derating limits below. Product Datasheet Download MEAN WELL MSP-300 Datasheet (PDF) The MSP-300 section is on PDF pages 6, 7, 8, 9. Refer to the complete mechanical drawings and notes when planning installation. Exact Model and Output Ratings Complete model MSP-300-15: MSP-300 single-output enclosed medical-type AC/DC power supply; -15 identifies the nominal 15 VDC output. Catalogue revision 2026-02-09. Rated output 15 VDC; 22 A; 330 W. Current range: 0–22 A. These are the exact model ratings, subject to the derating limits below. Output voltage adjustment 13.5–18 V using SVR. Observe the rated current and rated power limits when adjusting output voltage. Ripple and noise 150 mVp-p maximum; measured with 20 MHz bandwidth, a 12-inch twisted pair and 0.1 µF + 47 µF parallel capacitors. Voltage accuracy Voltage tolerance ±1.0%; line regulation ±0.3%; load regulation ±0.5%. Tolerance includes setup, line and load regulation. Typical efficiency 88%, at the catalogue default test conditions. Unless otherwise stated, specifications are measured at 230 VAC input, rated load and 25°C ambient. The family name is not a substitute for this exact model’s output rating. Input and Timing Normal input range 85–264 VAC or 120–370 VDC; AC frequency 47–63 Hz. Apply low-input derating. Active PFC Typical PF >0.95 at 230 VAC and >0.99 at 115 VAC, both at full load. Typical AC current 4.5 A at 115 VAC; 2.25 A at 230 VAC. Inrush / surge withstand Typical inrush 35 A at 115 VAC and 70 A at 230 VAC. Active inrush-current limiting is shown in the block diagram. Withstands 300 VAC surge input for 5 seconds; 300 VAC is not the continuous input rating. Setup / rise time 1000 ms / 50 ms at 230 VAC; 2500 ms / 50 ms at 115 VAC, at full load. Hold-up time 16 ms typical at 230 VAC and 16 ms typical at 115 VAC, at full load. No-load consumption No-load input power below 0.5 W with the main output remotely OFF: RC+ to RC− at 0–0.8 V or shorted. Medical Isolation, Leakage and Approval Scope Medical isolation level Primary-to-secondary: 2 × MOOP; primary-to-earth: 1 × MOOP. MOOP stands for means of operator protection. Leakage at 264 VAC Earth leakage <450 µA; touch leakage <100 µA. Listed safety approvals IEC60601-1:2005+A1+A2; ANSI/AAMI ES60601-1:2005+A2; CAN/CSA C22.2 No.60601-1:2014+A2; EAC TP TC004. Design references by request BS EN/EN60335-1 and BS EN/EN62368-1 are listed as design references, by request. Withstand voltage Input-to-output: 4 kVAC; input-to-FG: 2 kVAC; output-to-FG: 0.5 kVAC. Insulation resistance 100 MΩ minimum for input/output, input/FG and output/FG, tested at 500 VDC, 25°C and 70% RH. The stated insulation classification is MOOP. These pages do not establish a MOPP patient-protection rating or certify the completed medical equipment. Match the required insulation, leakage, grounding and final-system safety evaluation to the intended application. Protection and Cooling Short circuit / overload Short-circuit protection is listed. Overload threshold: 105–135% of rated output power, using constant-current limiting; automatic recovery after the fault is removed. Overvoltage 18.8–21.8 V threshold for this model; shuts down the output, with re-powering required to recover. Overtemperature Shuts down the output; automatic recovery after temperature falls. Controlled cooling fan Built-in fan ON/OFF control: fan turns on at a typical load threshold of 35 ±15%, or when internal thermistor RTH2 reaches at least 50°C. RTH2 is not the ambient-temperature rating. Ambient derating Horizontal mounting: 100% load from −40°C to +50°C, decreasing linearly to 50% at +70°C. The operating range is −40°C to +70°C, subject to this curve. Input-voltage derating At 60 Hz, the curve rises from 80% load at 85 VAC to 100% at 100 VAC, then remains at 100% through 264 VAC. Altitude derating For this fan-cooled model, reduce the allowed ambient temperature by 5°C per additional 1000 m above 2000 m. Apply input-voltage, temperature and output-rating limits together. Keep the indicated fan inlet/outlet and surrounding airflow path unobstructed; verify cooling in the final enclosure. No numerical mounting-clearance distance is specified in these catalogue pages. Standby, Remote Control and DC OK Standby output 5 V, 0.3 A maximum; tolerance ±5% (4.75–5.25 V), ripple 50 mVp-p maximum. AUX is not switched by the main-output remote ON/OFF control. Standby reference AUX pin 1 returns to AUXG pin 2. AUXG is isolated from the main +V/−V terminals; do not substitute the DC-OK ground. Remote ON/OFF Between RC+ pin 6 and RC− pin 4: 4–10 V or open contact = power ON; 0–0.8 V or short contact = power OFF. DC-OK signal DC-OK pin 3 is referenced to GND pin 5, which connects to main −V. TTL high when the PSU is ON: 3.3–5.6 V; OFF: 0–1 V. Remote sense Connect +S pin 7 to the positive load terminal and −S pin 8 to the negative load terminal. Twist +S and −S together; maximum line-drop compensation is 0.5 V. Use the complete function and connection drawings on PDF pages 8–9. DC-OK is a TTL status output, not a dry relay contact; no additional contact-current or sourcing-current rating is specified here. The documented functions for this family are standby, remote ON/OFF, DC OK and remote sense. No active current-sharing or parallel-unit count is specified for these models. Power Terminals and CN100 Pin Assignment Power terminals 1 / 2 / 3 AC/L / AC/N / FG (frame ground), respectively. Power terminals 4–5 / 6–7 4 and 5: DC −V; 6 and 7: DC +V. CN100 pin 1 — AUX 4.75–5.25 V auxiliary output, maximum 0.3 A, referenced to AUXG pin 2; remains available independently of remote ON/OFF control. CN100 pin 2 — AUXG Auxiliary return, isolated from the main +V and −V output terminals. CN100 pin 3 — DC-OK TTL status output referenced to GND pin 5; high when the PSU turns on. CN100 pin 4 — RC- Remote-control ground. CN100 pin 5 — GND DC-OK signal return; connected to the main −V output. CN100 pin 6 — RC+ Remote ON/OFF control input relative to RC− pin 4; an open contact enables the main output and a short disables it. CN100 pin 7 — +S Positive remote-sense lead to the positive load terminal; use a twisted pair with −S. CN100 pin 8 — -S Negative remote-sense lead to the negative load terminal; use a twisted pair with +S. Pin numbers refer to the actual connector orientation shown on PDF page 7. Verify polarity and the separate return functions before wiring. Mating Connector and Installation Parts Board connector CN100: HRS DF11-8DP-2DS or equivalent, as printed in the catalogue. Mating housing HRS DF11-8DS or equivalent, as printed. Contact reference HRS DF11-**SC or equivalent. The asterisks are a contact-family placeholder, not a complete orderable contact suffix. Confirm the complete mating-housing/contact variant, wire size and crimp tooling with the connector supplier before ordering. The catalogue does not specify an included harness quantity, a complete contact suffix or an accessory-kit order code; no inclusion is implied by the drawing. Dimensions, Mounting and Weight Body dimensions Case 980A; 199 × 105 × 41 mm (L × W × H), general drawing tolerance ±1 mm. Threaded mounting points The base drawing marks 4-M4 L=5, with 120 × 75 mm hole spacing. Each side drawing marks 4-M4 L=6; the two side-view longitudinal spacings are 168.5 mm and 167.5 mm as drawn. Follow each view and datum separately. Terminal and service clearance The power-terminal projection is 17 mm maximum. The drawing shows a 125 mm overall mounting-ear width outside the 105 mm body. Leave access to the input/output terminals, CN100 and SVR, and keep the fan airflow path clear. Local indication / adjustment LED and output-voltage adjustment SVR are identified on the mechanical drawing. Catalogue unit weight 950 g (0.95 kg), catalogue packing reference per unit from the PACKING row; not a measured net or shipping weight. Packing reference 15 pieces / 15.3 kg / 0.83 CUFT. This bulk packing reference is not the quantity supplied with an individual product. Use the complete dimension drawing on PDF page 7 for hole placement, connector orientation and installation envelope. The threaded-hole L markings must be respected; the diagram does not establish included screw quantities or tightening torques. Environment, EMC and Reliability Humidity / storage Operating humidity 20–90% RH, non-condensing. Storage −40°C to +85°C, 10–95% RH, non-condensing. Temperature coefficient ±0.03%/°C over 0–50°C. Vibration 10–500 Hz, 5G, 10 minutes per cycle, 60 minutes along each X, Y and Z axis. EMC emissions BS EN/EN55011 (CISPR11) Class B; BS EN/EN61000-3-2 and -3; EAC TP TC020. EMC immunity BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55035; BS EN/EN60601-1-2; EAC TP TC020. EMC test arrangement The catalogue EMC tests mount the supply on a 360 × 360 mm metal plate, 1 mm thick. The completed equipment must be reconfirmed against the applicable EMC requirements. MTBF reference 1337.5 K hours minimum, Telcordia SR-332 (Bellcore); 175.8 K hours minimum, MIL-HDBK-217F at 25°C. These are reliability estimates, not a guaranteed operating life. Switching reference PWM oscillator frequency: 70 kHz, as shown in the block diagram. Manufacturer warranty statement The manufacturer catalogue lists a five-year warranty; applicable manufacturer terms govern.

    $276.99


You have seen 24 out of 44 products

Footer image

© 2026 MEAN WELL, ,

  • US (USD $) US (USD $)
  • Ach Direct Debit
  • AliPay
  • Amazon
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • USDC
  • Visa